A microfluidic experimental platform with internal pressure measurements
Large inconsistencies in previous microchannel pressure drop data have motivated the development of a microchannel experimental platform that enables the measurement of pressures inside the microchannel. The system utilizes bulk etched silicon components that integrate pressure-sensing membranes wit...
Gespeichert in:
Veröffentlicht in: | Sensors and actuators. A. Physical. 2005-02, Vol.118 (2), p.212-221 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 221 |
---|---|
container_issue | 2 |
container_start_page | 212 |
container_title | Sensors and actuators. A. Physical. |
container_volume | 118 |
creator | Kohl, M.J. Abdel-Khalik, S.I. Jeter, S.M. Sadowski, D.L. |
description | Large inconsistencies in previous microchannel pressure drop data have motivated the development of a microchannel experimental platform that enables the measurement of pressures inside the microchannel. The system utilizes bulk etched silicon components that integrate pressure-sensing membranes with the microchannel test section. The deflection of the membranes is detected by an off-chip, optical-lever based system that allows the sensors to be calibrated for pressure measurement. The sensor sensitivity can be adjusted after microfabrication is complete, allowing for sensor optimization after fabrication. The sensor can be used in many applications where the fabrication of electrical contacts, piezoresistors and capacitors is problematic. Calibration uncertainties as low as 2% have been obtained during actual use of the system. The presented system resolves many of the issues associated with measuring pressures inside microchannels for the range of hydraulic diameters tested, 25–100
μm. The system has been used to study pressure drop in microchannels and a sample of the results is presented. It has been found that standard models with appropriate assumptions can accurately predict the measured pressure data. |
doi_str_mv | 10.1016/j.sna.2004.07.014 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_28510173</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0924424704005436</els_id><sourcerecordid>28510173</sourcerecordid><originalsourceid>FETCH-LOGICAL-c328t-d5bdaaf41b5543fdb59ed3b337fd83541d2e7a99b3af9e09a0ce92d3314fa2e3</originalsourceid><addsrcrecordid>eNp9kElLBDEUhIMoOI7-AG998tZttp508DQMbjDgZe4hnbxght5M0i7_3jTj2VPBo6p49SF0S3BFMNncH6s46IpizCssKkz4GVqRRrCS4Y08RyssKS855eISXcV4xBgzJsQKvWyL3pswum721psCvicIvoch6a6YOp3cGPriy6f3wg8JwrCcA8Q4Byh60Isu7niNLpzuItz86Rodnh4Pu5dy__b8utvuS8Nok0pbt1Zrx0lb15w529YSLGvzM842rObEUhBaypZpJwFLjQ1Iahkj3GkKbI3uTrVTGD9miEn1PhroOj3AOEdFmzrzECwbycmYx8UYwKkp79LhRxGsFmTqqDIytSBTWKiMLGceThnIAz49BBWNh8GA9QFMUnb0_6R_AUXmdm0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28510173</pqid></control><display><type>article</type><title>A microfluidic experimental platform with internal pressure measurements</title><source>Access via ScienceDirect (Elsevier)</source><creator>Kohl, M.J. ; Abdel-Khalik, S.I. ; Jeter, S.M. ; Sadowski, D.L.</creator><creatorcontrib>Kohl, M.J. ; Abdel-Khalik, S.I. ; Jeter, S.M. ; Sadowski, D.L.</creatorcontrib><description>Large inconsistencies in previous microchannel pressure drop data have motivated the development of a microchannel experimental platform that enables the measurement of pressures inside the microchannel. The system utilizes bulk etched silicon components that integrate pressure-sensing membranes with the microchannel test section. The deflection of the membranes is detected by an off-chip, optical-lever based system that allows the sensors to be calibrated for pressure measurement. The sensor sensitivity can be adjusted after microfabrication is complete, allowing for sensor optimization after fabrication. The sensor can be used in many applications where the fabrication of electrical contacts, piezoresistors and capacitors is problematic. Calibration uncertainties as low as 2% have been obtained during actual use of the system. The presented system resolves many of the issues associated with measuring pressures inside microchannels for the range of hydraulic diameters tested, 25–100
μm. The system has been used to study pressure drop in microchannels and a sample of the results is presented. It has been found that standard models with appropriate assumptions can accurately predict the measured pressure data.</description><identifier>ISSN: 0924-4247</identifier><identifier>EISSN: 1873-3069</identifier><identifier>DOI: 10.1016/j.sna.2004.07.014</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Microchannel ; Microfluidics ; Optical-lever ; Pressure sensor</subject><ispartof>Sensors and actuators. A. Physical., 2005-02, Vol.118 (2), p.212-221</ispartof><rights>2004 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c328t-d5bdaaf41b5543fdb59ed3b337fd83541d2e7a99b3af9e09a0ce92d3314fa2e3</citedby><cites>FETCH-LOGICAL-c328t-d5bdaaf41b5543fdb59ed3b337fd83541d2e7a99b3af9e09a0ce92d3314fa2e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.sna.2004.07.014$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Kohl, M.J.</creatorcontrib><creatorcontrib>Abdel-Khalik, S.I.</creatorcontrib><creatorcontrib>Jeter, S.M.</creatorcontrib><creatorcontrib>Sadowski, D.L.</creatorcontrib><title>A microfluidic experimental platform with internal pressure measurements</title><title>Sensors and actuators. A. Physical.</title><description>Large inconsistencies in previous microchannel pressure drop data have motivated the development of a microchannel experimental platform that enables the measurement of pressures inside the microchannel. The system utilizes bulk etched silicon components that integrate pressure-sensing membranes with the microchannel test section. The deflection of the membranes is detected by an off-chip, optical-lever based system that allows the sensors to be calibrated for pressure measurement. The sensor sensitivity can be adjusted after microfabrication is complete, allowing for sensor optimization after fabrication. The sensor can be used in many applications where the fabrication of electrical contacts, piezoresistors and capacitors is problematic. Calibration uncertainties as low as 2% have been obtained during actual use of the system. The presented system resolves many of the issues associated with measuring pressures inside microchannels for the range of hydraulic diameters tested, 25–100
μm. The system has been used to study pressure drop in microchannels and a sample of the results is presented. It has been found that standard models with appropriate assumptions can accurately predict the measured pressure data.</description><subject>Microchannel</subject><subject>Microfluidics</subject><subject>Optical-lever</subject><subject>Pressure sensor</subject><issn>0924-4247</issn><issn>1873-3069</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNp9kElLBDEUhIMoOI7-AG998tZttp508DQMbjDgZe4hnbxght5M0i7_3jTj2VPBo6p49SF0S3BFMNncH6s46IpizCssKkz4GVqRRrCS4Y08RyssKS855eISXcV4xBgzJsQKvWyL3pswum721psCvicIvoch6a6YOp3cGPriy6f3wg8JwrCcA8Q4Byh60Isu7niNLpzuItz86Rodnh4Pu5dy__b8utvuS8Nok0pbt1Zrx0lb15w529YSLGvzM842rObEUhBaypZpJwFLjQ1Iahkj3GkKbI3uTrVTGD9miEn1PhroOj3AOEdFmzrzECwbycmYx8UYwKkp79LhRxGsFmTqqDIytSBTWKiMLGceThnIAz49BBWNh8GA9QFMUnb0_6R_AUXmdm0</recordid><startdate>20050228</startdate><enddate>20050228</enddate><creator>Kohl, M.J.</creator><creator>Abdel-Khalik, S.I.</creator><creator>Jeter, S.M.</creator><creator>Sadowski, D.L.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20050228</creationdate><title>A microfluidic experimental platform with internal pressure measurements</title><author>Kohl, M.J. ; Abdel-Khalik, S.I. ; Jeter, S.M. ; Sadowski, D.L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c328t-d5bdaaf41b5543fdb59ed3b337fd83541d2e7a99b3af9e09a0ce92d3314fa2e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Microchannel</topic><topic>Microfluidics</topic><topic>Optical-lever</topic><topic>Pressure sensor</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kohl, M.J.</creatorcontrib><creatorcontrib>Abdel-Khalik, S.I.</creatorcontrib><creatorcontrib>Jeter, S.M.</creatorcontrib><creatorcontrib>Sadowski, D.L.</creatorcontrib><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. A. Physical.</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kohl, M.J.</au><au>Abdel-Khalik, S.I.</au><au>Jeter, S.M.</au><au>Sadowski, D.L.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A microfluidic experimental platform with internal pressure measurements</atitle><jtitle>Sensors and actuators. A. Physical.</jtitle><date>2005-02-28</date><risdate>2005</risdate><volume>118</volume><issue>2</issue><spage>212</spage><epage>221</epage><pages>212-221</pages><issn>0924-4247</issn><eissn>1873-3069</eissn><abstract>Large inconsistencies in previous microchannel pressure drop data have motivated the development of a microchannel experimental platform that enables the measurement of pressures inside the microchannel. The system utilizes bulk etched silicon components that integrate pressure-sensing membranes with the microchannel test section. The deflection of the membranes is detected by an off-chip, optical-lever based system that allows the sensors to be calibrated for pressure measurement. The sensor sensitivity can be adjusted after microfabrication is complete, allowing for sensor optimization after fabrication. The sensor can be used in many applications where the fabrication of electrical contacts, piezoresistors and capacitors is problematic. Calibration uncertainties as low as 2% have been obtained during actual use of the system. The presented system resolves many of the issues associated with measuring pressures inside microchannels for the range of hydraulic diameters tested, 25–100
μm. The system has been used to study pressure drop in microchannels and a sample of the results is presented. It has been found that standard models with appropriate assumptions can accurately predict the measured pressure data.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.sna.2004.07.014</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0924-4247 |
ispartof | Sensors and actuators. A. Physical., 2005-02, Vol.118 (2), p.212-221 |
issn | 0924-4247 1873-3069 |
language | eng |
recordid | cdi_proquest_miscellaneous_28510173 |
source | Access via ScienceDirect (Elsevier) |
subjects | Microchannel Microfluidics Optical-lever Pressure sensor |
title | A microfluidic experimental platform with internal pressure measurements |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T08%3A23%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20microfluidic%20experimental%20platform%20with%20internal%20pressure%20measurements&rft.jtitle=Sensors%20and%20actuators.%20A.%20Physical.&rft.au=Kohl,%20M.J.&rft.date=2005-02-28&rft.volume=118&rft.issue=2&rft.spage=212&rft.epage=221&rft.pages=212-221&rft.issn=0924-4247&rft.eissn=1873-3069&rft_id=info:doi/10.1016/j.sna.2004.07.014&rft_dat=%3Cproquest_cross%3E28510173%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=28510173&rft_id=info:pmid/&rft_els_id=S0924424704005436&rfr_iscdi=true |