Evaluation of the Preoperative Slide Test in the Prediction of Intra-Abdominal Adhesions: A Single-Center, Double-Blinded, Prospective Observational Study

Background To evaluate the efficacy of the preoperative ultrasonographic sliding sign in predicting intra-abdominal adhesions. Methods This was a single-center, double-blinded, prospective observational study undertaken from March and September 2021 on 110 patients with a history of previous abdomin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgical innovation 2023-10, Vol.30 (5), p.557-563
Hauptverfasser: Ozturk, Ugur K., Keles, Esra, Akış, Serkan, Alınca, Cihat M., Acar, Sami, Ozyurek, Sefik E., Api, Murat
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 563
container_issue 5
container_start_page 557
container_title Surgical innovation
container_volume 30
creator Ozturk, Ugur K.
Keles, Esra
Akış, Serkan
Alınca, Cihat M.
Acar, Sami
Ozyurek, Sefik E.
Api, Murat
description Background To evaluate the efficacy of the preoperative ultrasonographic sliding sign in predicting intra-abdominal adhesions. Methods This was a single-center, double-blinded, prospective observational study undertaken from March and September 2021 on 110 patients with a history of previous abdominal surgery. All patients who were scheduled for laparoscopy underwent slide test in 5 zones of abdomen: right lower quadrant, left lower quadrant, previous operation site, vesicouterine pouch, and rectovaginal pouch. Adhesions were assessed by the same gynecologic surgeon using ultrasonography before the surgery and by gynecological surgeons during surgery, and by a third gynecologic surgeon to compare the preoperative slide test findings and laparoscopic findings after the surgery. Results Seventy-three (66.4%) patients underwent laparoscopic surgery, and 37 (33.6%) patients underwent laparotomy. The mean age of patients was 46.9 ± 1.0 years. Sensitivity, specificity, and positive and negative predictive values of preoperative ultrasonography in predicting adhesions were 89.5%, 91.7%, 97.5%, and 71.0%, respectively. The accuracy of the slide test was calculated as 90.0%. It was found that as the total number of cesarean sections increased the estimates of vesicouterine adhesions and actual adhesions increased (P = .008). Also, the prediction of intra-abdominal adhesions and actual adhesions significantly increased as the total number of surgical operations increased (P = .002). Conclusions Intra-abdominal adhesions can be detected with the slide test, which is a non-invasive and well-tolerated procedure. Slide test can guide the physician before the elective operation in patients with previous abdominal surgery and may assist in counseling patients.
doi_str_mv 10.1177/15533506231186071
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2844085225</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_15533506231186071</sage_id><sourcerecordid>2844085225</sourcerecordid><originalsourceid>FETCH-LOGICAL-c292t-a2c39e6969fdcc6d9f3348d9ba9ab01cc602d83822271e840048652b2ccc58cc3</originalsourceid><addsrcrecordid>eNp9UctOwzAQtBCIR-EDuCAfOZDiR5w43Ep5SkggtZwjx94UozQudlKJX-FrMX1wQeJke3Zmdr2D0CklQ0rz_JIKwbkgGeOUyozkdAcd_mAJFzTd_b2T7AAdhfBOSCooEfvogOeCSsLoIfq6XaqmV511LXY17t4Av3hwC_ARWwKeNNYAnkLosG23ZWP1VvDYdl4lo8q4uW1Vg0fmDUKshSs8whPbzhpIxtB24C_wjeur-LxubGvAXEQnFxagV32eqwB-uZojuky63nweo71aNQFONucAvd7dTscPydPz_eN49JRoVrAuUUzzArIiK2qjdWaKmvNUmqJShaoIjRBhRnLJGMspyDRuQWaCVUxrLaTWfIDO174L7z76-NNyboOGplEtuD6UTKYpkYIxEal0TdVx9OChLhfezpX_LCkpfyIp_0QSNWcb-76ag_lVbDOIhOGaENQMynfX-7iC8I_jN2xIlNk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2844085225</pqid></control><display><type>article</type><title>Evaluation of the Preoperative Slide Test in the Prediction of Intra-Abdominal Adhesions: A Single-Center, Double-Blinded, Prospective Observational Study</title><source>SAGE Complete</source><source>Alma/SFX Local Collection</source><creator>Ozturk, Ugur K. ; Keles, Esra ; Akış, Serkan ; Alınca, Cihat M. ; Acar, Sami ; Ozyurek, Sefik E. ; Api, Murat</creator><creatorcontrib>Ozturk, Ugur K. ; Keles, Esra ; Akış, Serkan ; Alınca, Cihat M. ; Acar, Sami ; Ozyurek, Sefik E. ; Api, Murat</creatorcontrib><description>Background To evaluate the efficacy of the preoperative ultrasonographic sliding sign in predicting intra-abdominal adhesions. Methods This was a single-center, double-blinded, prospective observational study undertaken from March and September 2021 on 110 patients with a history of previous abdominal surgery. All patients who were scheduled for laparoscopy underwent slide test in 5 zones of abdomen: right lower quadrant, left lower quadrant, previous operation site, vesicouterine pouch, and rectovaginal pouch. Adhesions were assessed by the same gynecologic surgeon using ultrasonography before the surgery and by gynecological surgeons during surgery, and by a third gynecologic surgeon to compare the preoperative slide test findings and laparoscopic findings after the surgery. Results Seventy-three (66.4%) patients underwent laparoscopic surgery, and 37 (33.6%) patients underwent laparotomy. The mean age of patients was 46.9 ± 1.0 years. Sensitivity, specificity, and positive and negative predictive values of preoperative ultrasonography in predicting adhesions were 89.5%, 91.7%, 97.5%, and 71.0%, respectively. The accuracy of the slide test was calculated as 90.0%. It was found that as the total number of cesarean sections increased the estimates of vesicouterine adhesions and actual adhesions increased (P = .008). Also, the prediction of intra-abdominal adhesions and actual adhesions significantly increased as the total number of surgical operations increased (P = .002). Conclusions Intra-abdominal adhesions can be detected with the slide test, which is a non-invasive and well-tolerated procedure. Slide test can guide the physician before the elective operation in patients with previous abdominal surgery and may assist in counseling patients.</description><identifier>ISSN: 1553-3506</identifier><identifier>EISSN: 1553-3514</identifier><identifier>DOI: 10.1177/15533506231186071</identifier><identifier>PMID: 37518021</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><ispartof>Surgical innovation, 2023-10, Vol.30 (5), p.557-563</ispartof><rights>The Author(s) 2023</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c292t-a2c39e6969fdcc6d9f3348d9ba9ab01cc602d83822271e840048652b2ccc58cc3</cites><orcidid>0000-0003-0620-1500 ; 0000-0001-8099-8883</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/15533506231186071$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/15533506231186071$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,776,780,21798,27901,27902,43597,43598</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37518021$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ozturk, Ugur K.</creatorcontrib><creatorcontrib>Keles, Esra</creatorcontrib><creatorcontrib>Akış, Serkan</creatorcontrib><creatorcontrib>Alınca, Cihat M.</creatorcontrib><creatorcontrib>Acar, Sami</creatorcontrib><creatorcontrib>Ozyurek, Sefik E.</creatorcontrib><creatorcontrib>Api, Murat</creatorcontrib><title>Evaluation of the Preoperative Slide Test in the Prediction of Intra-Abdominal Adhesions: A Single-Center, Double-Blinded, Prospective Observational Study</title><title>Surgical innovation</title><addtitle>Surg Innov</addtitle><description>Background To evaluate the efficacy of the preoperative ultrasonographic sliding sign in predicting intra-abdominal adhesions. Methods This was a single-center, double-blinded, prospective observational study undertaken from March and September 2021 on 110 patients with a history of previous abdominal surgery. All patients who were scheduled for laparoscopy underwent slide test in 5 zones of abdomen: right lower quadrant, left lower quadrant, previous operation site, vesicouterine pouch, and rectovaginal pouch. Adhesions were assessed by the same gynecologic surgeon using ultrasonography before the surgery and by gynecological surgeons during surgery, and by a third gynecologic surgeon to compare the preoperative slide test findings and laparoscopic findings after the surgery. Results Seventy-three (66.4%) patients underwent laparoscopic surgery, and 37 (33.6%) patients underwent laparotomy. The mean age of patients was 46.9 ± 1.0 years. Sensitivity, specificity, and positive and negative predictive values of preoperative ultrasonography in predicting adhesions were 89.5%, 91.7%, 97.5%, and 71.0%, respectively. The accuracy of the slide test was calculated as 90.0%. It was found that as the total number of cesarean sections increased the estimates of vesicouterine adhesions and actual adhesions increased (P = .008). Also, the prediction of intra-abdominal adhesions and actual adhesions significantly increased as the total number of surgical operations increased (P = .002). Conclusions Intra-abdominal adhesions can be detected with the slide test, which is a non-invasive and well-tolerated procedure. Slide test can guide the physician before the elective operation in patients with previous abdominal surgery and may assist in counseling patients.</description><issn>1553-3506</issn><issn>1553-3514</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9UctOwzAQtBCIR-EDuCAfOZDiR5w43Ep5SkggtZwjx94UozQudlKJX-FrMX1wQeJke3Zmdr2D0CklQ0rz_JIKwbkgGeOUyozkdAcd_mAJFzTd_b2T7AAdhfBOSCooEfvogOeCSsLoIfq6XaqmV511LXY17t4Av3hwC_ARWwKeNNYAnkLosG23ZWP1VvDYdl4lo8q4uW1Vg0fmDUKshSs8whPbzhpIxtB24C_wjeur-LxubGvAXEQnFxagV32eqwB-uZojuky63nweo71aNQFONucAvd7dTscPydPz_eN49JRoVrAuUUzzArIiK2qjdWaKmvNUmqJShaoIjRBhRnLJGMspyDRuQWaCVUxrLaTWfIDO174L7z76-NNyboOGplEtuD6UTKYpkYIxEal0TdVx9OChLhfezpX_LCkpfyIp_0QSNWcb-76ag_lVbDOIhOGaENQMynfX-7iC8I_jN2xIlNk</recordid><startdate>20231001</startdate><enddate>20231001</enddate><creator>Ozturk, Ugur K.</creator><creator>Keles, Esra</creator><creator>Akış, Serkan</creator><creator>Alınca, Cihat M.</creator><creator>Acar, Sami</creator><creator>Ozyurek, Sefik E.</creator><creator>Api, Murat</creator><general>SAGE Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-0620-1500</orcidid><orcidid>https://orcid.org/0000-0001-8099-8883</orcidid></search><sort><creationdate>20231001</creationdate><title>Evaluation of the Preoperative Slide Test in the Prediction of Intra-Abdominal Adhesions: A Single-Center, Double-Blinded, Prospective Observational Study</title><author>Ozturk, Ugur K. ; Keles, Esra ; Akış, Serkan ; Alınca, Cihat M. ; Acar, Sami ; Ozyurek, Sefik E. ; Api, Murat</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c292t-a2c39e6969fdcc6d9f3348d9ba9ab01cc602d83822271e840048652b2ccc58cc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ozturk, Ugur K.</creatorcontrib><creatorcontrib>Keles, Esra</creatorcontrib><creatorcontrib>Akış, Serkan</creatorcontrib><creatorcontrib>Alınca, Cihat M.</creatorcontrib><creatorcontrib>Acar, Sami</creatorcontrib><creatorcontrib>Ozyurek, Sefik E.</creatorcontrib><creatorcontrib>Api, Murat</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Surgical innovation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ozturk, Ugur K.</au><au>Keles, Esra</au><au>Akış, Serkan</au><au>Alınca, Cihat M.</au><au>Acar, Sami</au><au>Ozyurek, Sefik E.</au><au>Api, Murat</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of the Preoperative Slide Test in the Prediction of Intra-Abdominal Adhesions: A Single-Center, Double-Blinded, Prospective Observational Study</atitle><jtitle>Surgical innovation</jtitle><addtitle>Surg Innov</addtitle><date>2023-10-01</date><risdate>2023</risdate><volume>30</volume><issue>5</issue><spage>557</spage><epage>563</epage><pages>557-563</pages><issn>1553-3506</issn><eissn>1553-3514</eissn><abstract>Background To evaluate the efficacy of the preoperative ultrasonographic sliding sign in predicting intra-abdominal adhesions. Methods This was a single-center, double-blinded, prospective observational study undertaken from March and September 2021 on 110 patients with a history of previous abdominal surgery. All patients who were scheduled for laparoscopy underwent slide test in 5 zones of abdomen: right lower quadrant, left lower quadrant, previous operation site, vesicouterine pouch, and rectovaginal pouch. Adhesions were assessed by the same gynecologic surgeon using ultrasonography before the surgery and by gynecological surgeons during surgery, and by a third gynecologic surgeon to compare the preoperative slide test findings and laparoscopic findings after the surgery. Results Seventy-three (66.4%) patients underwent laparoscopic surgery, and 37 (33.6%) patients underwent laparotomy. The mean age of patients was 46.9 ± 1.0 years. Sensitivity, specificity, and positive and negative predictive values of preoperative ultrasonography in predicting adhesions were 89.5%, 91.7%, 97.5%, and 71.0%, respectively. The accuracy of the slide test was calculated as 90.0%. It was found that as the total number of cesarean sections increased the estimates of vesicouterine adhesions and actual adhesions increased (P = .008). Also, the prediction of intra-abdominal adhesions and actual adhesions significantly increased as the total number of surgical operations increased (P = .002). Conclusions Intra-abdominal adhesions can be detected with the slide test, which is a non-invasive and well-tolerated procedure. Slide test can guide the physician before the elective operation in patients with previous abdominal surgery and may assist in counseling patients.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>37518021</pmid><doi>10.1177/15533506231186071</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0003-0620-1500</orcidid><orcidid>https://orcid.org/0000-0001-8099-8883</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1553-3506
ispartof Surgical innovation, 2023-10, Vol.30 (5), p.557-563
issn 1553-3506
1553-3514
language eng
recordid cdi_proquest_miscellaneous_2844085225
source SAGE Complete; Alma/SFX Local Collection
title Evaluation of the Preoperative Slide Test in the Prediction of Intra-Abdominal Adhesions: A Single-Center, Double-Blinded, Prospective Observational Study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-14T09%3A26%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20the%20Preoperative%20Slide%20Test%20in%20the%20Prediction%20of%20Intra-Abdominal%20Adhesions:%20A%20Single-Center,%20Double-Blinded,%20Prospective%20Observational%20Study&rft.jtitle=Surgical%20innovation&rft.au=Ozturk,%20Ugur%20K.&rft.date=2023-10-01&rft.volume=30&rft.issue=5&rft.spage=557&rft.epage=563&rft.pages=557-563&rft.issn=1553-3506&rft.eissn=1553-3514&rft_id=info:doi/10.1177/15533506231186071&rft_dat=%3Cproquest_cross%3E2844085225%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2844085225&rft_id=info:pmid/37518021&rft_sage_id=10.1177_15533506231186071&rfr_iscdi=true