Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode

In this work, we describe the development of an electrochemical sensing platform that employs electrochemically reduced graphene oxide (ErGO) and gold (Au) deposited on a screen-printed carbon electrode (SPCE) to synthesize Au/ErGO/SPCE for the determination of the antibiotic drug doxycycline (DC)....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical sciences 2023-11, Vol.39 (11), p.1889-1899
Hauptverfasser: Tiwari, M. S., Thorat, R. G., Popatkar, B. B., Borge, V. V., Kadu, A. K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1899
container_issue 11
container_start_page 1889
container_title Analytical sciences
container_volume 39
creator Tiwari, M. S.
Thorat, R. G.
Popatkar, B. B.
Borge, V. V.
Kadu, A. K.
description In this work, we describe the development of an electrochemical sensing platform that employs electrochemically reduced graphene oxide (ErGO) and gold (Au) deposited on a screen-printed carbon electrode (SPCE) to synthesize Au/ErGO/SPCE for the determination of the antibiotic drug doxycycline (DC). A modified Hummer’s approach was adopted to initially prepare graphene oxide, which was then characterized by using powder XRD, FTIR, and UV spectroscopy before being utilized for modification on SPCE. Cyclic voltammetry was performed to form ErGO on SPCE to give ErGO/SPCE followed by electrodeposition of gold to get a final modified electrode Au/ErGO/SPCE. The effect of experimental conditions, like scan rate and pH on the electrochemical behavior of DC for Au/ErGO/SPCE, was evaluated. Square wave voltammetry (SWV) and cyclic voltammetry (CV) measurements were used to assess the electro-oxidation of DC on Au/ErGO/SPCE, and the electrochemical reaction conditions were also optimized. Furthermore, Au/ErGO/SPCE-based electrochemical sensors showed good recovery and high accuracy for DC determination in the complex food matrix and blood serum. The limit of detection (LOD), the limit of quantification (LOQ), and the linear calibration range of DC on Au/ErGO/SPCE under optimum experimental conditions were 0.124 µm, 0.415 µm, and 1–100 µm respectively, with high sensitivity of 0.194 μA μM −1  cm −2 . Finally, the proposed electrochemical sensing platform was effectively used to determine low DC concentrations in real samples such as chicken flesh and blood serum, indicating its wide range of applications in quality control. Graphical Abstract
doi_str_mv 10.1007/s44211-023-00395-5
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2843033931</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2843033931</sourcerecordid><originalsourceid>FETCH-LOGICAL-c391t-99a25a73cbf4500ea34603b10b8d87544c66a89599c9a12085b0a08c029f9d053</originalsourceid><addsrcrecordid>eNp9kMtKxTAQhoMoery8gAvp0k10cmlPsxTxBoIbdRvSZCrRNtEkBc_b2-NRl64Ghv__mPkIOWZwxgCW51lKzhgFLiiAUDWtt8iCCdlSzmWzTRagGNBGSNgj-zm_AjDecr5L9sRSqlrxZkHwOQ7FjCOW5G3lsGAafTDFx1DFvnLxc2VXdvABKx-qHtHlEu1bNWUfXqoxOt97dJU1qZsb2SbEQN-TD2Xe4oC2pOjwkOz0Zsh49DMPyNP11ePlLb1_uLm7vLinVihWqFKG12YpbNfLGgCNkA2IjkHXunZZS2mbxrTz5coqwzi0dQcGWgtc9cpBLQ7I6Yb7nuLHhLno0WeLw2ACxilr3koBQijB5ijfRG2KOSfs9Xz1aNJKM9BrvXqjV8969bdeveaf_PCnbkT3V_n1OQfEJpDXDl4w6dc4pTD__B_2C41ShoA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2843033931</pqid></control><display><type>article</type><title>Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode</title><source>Freely Accessible Japanese Titles</source><source>EZB-FREE-00999 freely available EZB journals</source><source>SpringerLink Journals - AutoHoldings</source><creator>Tiwari, M. S. ; Thorat, R. G. ; Popatkar, B. B. ; Borge, V. V. ; Kadu, A. K.</creator><creatorcontrib>Tiwari, M. S. ; Thorat, R. G. ; Popatkar, B. B. ; Borge, V. V. ; Kadu, A. K.</creatorcontrib><description>In this work, we describe the development of an electrochemical sensing platform that employs electrochemically reduced graphene oxide (ErGO) and gold (Au) deposited on a screen-printed carbon electrode (SPCE) to synthesize Au/ErGO/SPCE for the determination of the antibiotic drug doxycycline (DC). A modified Hummer’s approach was adopted to initially prepare graphene oxide, which was then characterized by using powder XRD, FTIR, and UV spectroscopy before being utilized for modification on SPCE. Cyclic voltammetry was performed to form ErGO on SPCE to give ErGO/SPCE followed by electrodeposition of gold to get a final modified electrode Au/ErGO/SPCE. The effect of experimental conditions, like scan rate and pH on the electrochemical behavior of DC for Au/ErGO/SPCE, was evaluated. Square wave voltammetry (SWV) and cyclic voltammetry (CV) measurements were used to assess the electro-oxidation of DC on Au/ErGO/SPCE, and the electrochemical reaction conditions were also optimized. Furthermore, Au/ErGO/SPCE-based electrochemical sensors showed good recovery and high accuracy for DC determination in the complex food matrix and blood serum. The limit of detection (LOD), the limit of quantification (LOQ), and the linear calibration range of DC on Au/ErGO/SPCE under optimum experimental conditions were 0.124 µm, 0.415 µm, and 1–100 µm respectively, with high sensitivity of 0.194 μA μM −1  cm −2 . Finally, the proposed electrochemical sensing platform was effectively used to determine low DC concentrations in real samples such as chicken flesh and blood serum, indicating its wide range of applications in quality control. Graphical Abstract</description><identifier>ISSN: 0910-6340</identifier><identifier>EISSN: 1348-2246</identifier><identifier>DOI: 10.1007/s44211-023-00395-5</identifier><identifier>PMID: 37495926</identifier><language>eng</language><publisher>Singapore: Springer Nature Singapore</publisher><subject>Analytical Chemistry ; Chemistry ; Chemistry and Materials Science ; Original Paper</subject><ispartof>Analytical sciences, 2023-11, Vol.39 (11), p.1889-1899</ispartof><rights>The Author(s), under exclusive licence to The Japan Society for Analytical Chemistry 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.</rights><rights>2023. The Author(s), under exclusive licence to The Japan Society for Analytical Chemistry.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c391t-99a25a73cbf4500ea34603b10b8d87544c66a89599c9a12085b0a08c029f9d053</citedby><cites>FETCH-LOGICAL-c391t-99a25a73cbf4500ea34603b10b8d87544c66a89599c9a12085b0a08c029f9d053</cites><orcidid>0000-0001-9499-1551</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s44211-023-00395-5$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s44211-023-00395-5$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37495926$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tiwari, M. S.</creatorcontrib><creatorcontrib>Thorat, R. G.</creatorcontrib><creatorcontrib>Popatkar, B. B.</creatorcontrib><creatorcontrib>Borge, V. V.</creatorcontrib><creatorcontrib>Kadu, A. K.</creatorcontrib><title>Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode</title><title>Analytical sciences</title><addtitle>ANAL. SCI</addtitle><addtitle>Anal Sci</addtitle><description>In this work, we describe the development of an electrochemical sensing platform that employs electrochemically reduced graphene oxide (ErGO) and gold (Au) deposited on a screen-printed carbon electrode (SPCE) to synthesize Au/ErGO/SPCE for the determination of the antibiotic drug doxycycline (DC). A modified Hummer’s approach was adopted to initially prepare graphene oxide, which was then characterized by using powder XRD, FTIR, and UV spectroscopy before being utilized for modification on SPCE. Cyclic voltammetry was performed to form ErGO on SPCE to give ErGO/SPCE followed by electrodeposition of gold to get a final modified electrode Au/ErGO/SPCE. The effect of experimental conditions, like scan rate and pH on the electrochemical behavior of DC for Au/ErGO/SPCE, was evaluated. Square wave voltammetry (SWV) and cyclic voltammetry (CV) measurements were used to assess the electro-oxidation of DC on Au/ErGO/SPCE, and the electrochemical reaction conditions were also optimized. Furthermore, Au/ErGO/SPCE-based electrochemical sensors showed good recovery and high accuracy for DC determination in the complex food matrix and blood serum. The limit of detection (LOD), the limit of quantification (LOQ), and the linear calibration range of DC on Au/ErGO/SPCE under optimum experimental conditions were 0.124 µm, 0.415 µm, and 1–100 µm respectively, with high sensitivity of 0.194 μA μM −1  cm −2 . Finally, the proposed electrochemical sensing platform was effectively used to determine low DC concentrations in real samples such as chicken flesh and blood serum, indicating its wide range of applications in quality control. Graphical Abstract</description><subject>Analytical Chemistry</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Original Paper</subject><issn>0910-6340</issn><issn>1348-2246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kMtKxTAQhoMoery8gAvp0k10cmlPsxTxBoIbdRvSZCrRNtEkBc_b2-NRl64Ghv__mPkIOWZwxgCW51lKzhgFLiiAUDWtt8iCCdlSzmWzTRagGNBGSNgj-zm_AjDecr5L9sRSqlrxZkHwOQ7FjCOW5G3lsGAafTDFx1DFvnLxc2VXdvABKx-qHtHlEu1bNWUfXqoxOt97dJU1qZsb2SbEQN-TD2Xe4oC2pOjwkOz0Zsh49DMPyNP11ePlLb1_uLm7vLinVihWqFKG12YpbNfLGgCNkA2IjkHXunZZS2mbxrTz5coqwzi0dQcGWgtc9cpBLQ7I6Yb7nuLHhLno0WeLw2ACxilr3koBQijB5ijfRG2KOSfs9Xz1aNJKM9BrvXqjV8969bdeveaf_PCnbkT3V_n1OQfEJpDXDl4w6dc4pTD__B_2C41ShoA</recordid><startdate>20231101</startdate><enddate>20231101</enddate><creator>Tiwari, M. S.</creator><creator>Thorat, R. G.</creator><creator>Popatkar, B. B.</creator><creator>Borge, V. V.</creator><creator>Kadu, A. K.</creator><general>Springer Nature Singapore</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-9499-1551</orcidid></search><sort><creationdate>20231101</creationdate><title>Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode</title><author>Tiwari, M. S. ; Thorat, R. G. ; Popatkar, B. B. ; Borge, V. V. ; Kadu, A. K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c391t-99a25a73cbf4500ea34603b10b8d87544c66a89599c9a12085b0a08c029f9d053</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Analytical Chemistry</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Original Paper</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tiwari, M. S.</creatorcontrib><creatorcontrib>Thorat, R. G.</creatorcontrib><creatorcontrib>Popatkar, B. B.</creatorcontrib><creatorcontrib>Borge, V. V.</creatorcontrib><creatorcontrib>Kadu, A. K.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tiwari, M. S.</au><au>Thorat, R. G.</au><au>Popatkar, B. B.</au><au>Borge, V. V.</au><au>Kadu, A. K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode</atitle><jtitle>Analytical sciences</jtitle><stitle>ANAL. SCI</stitle><addtitle>Anal Sci</addtitle><date>2023-11-01</date><risdate>2023</risdate><volume>39</volume><issue>11</issue><spage>1889</spage><epage>1899</epage><pages>1889-1899</pages><issn>0910-6340</issn><eissn>1348-2246</eissn><abstract>In this work, we describe the development of an electrochemical sensing platform that employs electrochemically reduced graphene oxide (ErGO) and gold (Au) deposited on a screen-printed carbon electrode (SPCE) to synthesize Au/ErGO/SPCE for the determination of the antibiotic drug doxycycline (DC). A modified Hummer’s approach was adopted to initially prepare graphene oxide, which was then characterized by using powder XRD, FTIR, and UV spectroscopy before being utilized for modification on SPCE. Cyclic voltammetry was performed to form ErGO on SPCE to give ErGO/SPCE followed by electrodeposition of gold to get a final modified electrode Au/ErGO/SPCE. The effect of experimental conditions, like scan rate and pH on the electrochemical behavior of DC for Au/ErGO/SPCE, was evaluated. Square wave voltammetry (SWV) and cyclic voltammetry (CV) measurements were used to assess the electro-oxidation of DC on Au/ErGO/SPCE, and the electrochemical reaction conditions were also optimized. Furthermore, Au/ErGO/SPCE-based electrochemical sensors showed good recovery and high accuracy for DC determination in the complex food matrix and blood serum. The limit of detection (LOD), the limit of quantification (LOQ), and the linear calibration range of DC on Au/ErGO/SPCE under optimum experimental conditions were 0.124 µm, 0.415 µm, and 1–100 µm respectively, with high sensitivity of 0.194 μA μM −1  cm −2 . Finally, the proposed electrochemical sensing platform was effectively used to determine low DC concentrations in real samples such as chicken flesh and blood serum, indicating its wide range of applications in quality control. Graphical Abstract</abstract><cop>Singapore</cop><pub>Springer Nature Singapore</pub><pmid>37495926</pmid><doi>10.1007/s44211-023-00395-5</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0001-9499-1551</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0910-6340
ispartof Analytical sciences, 2023-11, Vol.39 (11), p.1889-1899
issn 0910-6340
1348-2246
language eng
recordid cdi_proquest_miscellaneous_2843033931
source Freely Accessible Japanese Titles; EZB-FREE-00999 freely available EZB journals; SpringerLink Journals - AutoHoldings
subjects Analytical Chemistry
Chemistry
Chemistry and Materials Science
Original Paper
title Voltammetric determination of doxycycline in feedstock using modified carbon screen-printed electrode
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T22%3A25%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Voltammetric%20determination%20of%20doxycycline%20in%20feedstock%20using%20modified%20carbon%20screen-printed%20electrode&rft.jtitle=Analytical%20sciences&rft.au=Tiwari,%20M.%20S.&rft.date=2023-11-01&rft.volume=39&rft.issue=11&rft.spage=1889&rft.epage=1899&rft.pages=1889-1899&rft.issn=0910-6340&rft.eissn=1348-2246&rft_id=info:doi/10.1007/s44211-023-00395-5&rft_dat=%3Cproquest_cross%3E2843033931%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2843033931&rft_id=info:pmid/37495926&rfr_iscdi=true