Tactile misfit detection ability at the implant-abutment interface of internal connection dental implants: an in-vitro study

The aim of this in-vitro study was to investigate the tactile assessment ability at the implant impression-taking stage. Thirty clinicians (18 novices, 12 experts) were included for a tactile fit assessment by using a used/new probe (tip diameter 100 µm/20 µm). Six implant replicas and related impre...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta odontologica Scandinavica 2023-11, Vol.ahead-of-print (ahead-of-print), p.1-6
Hauptverfasser: Molinero-Mourelle, Pedro, Peter, Lukas, Gaviria, Ana Sol, Fonseca, Manrique, Schimmel, Martin, Katsoulis, Joannis
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this in-vitro study was to investigate the tactile assessment ability at the implant impression-taking stage. Thirty clinicians (18 novices, 12 experts) were included for a tactile fit assessment by using a used/new probe (tip diameter 100 µm/20 µm). Six implant replicas and related impression copings of two internal connection implant systems were used, each with a perfect fit (0 µm) and defined vertical micro gaps of 8, 24, 55, 110 and 220 µm at the interface. Statistical analysis was performed using descriptive methods and non-parametric tests with a focus on specificity (ability to detect perfect fit), sensitivity (ability to detect misfit), and predictive values. P-values
ISSN:0001-6357
1502-3850
DOI:10.1080/00016357.2023.2223715