Computational investigation of flow characteristics and particle deposition patterns in a realistic human airway model under different breathing conditions

Airborne particle pollution causes a range of respiratory and cardiovascular disorders by entering the human respiratory system through the breathing process. The administration of pharmaceutical particles by inhalation is another effective way to treat pulmonary illnesses. Studying particle deposit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Respiratory physiology & neurobiology 2023-08, Vol.314, p.104085-104085, Article 104085
Hauptverfasser: Liu, Huanxi, Ma, Songhua, Hu, Tianliang, Ma, Dedong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 104085
container_issue
container_start_page 104085
container_title Respiratory physiology & neurobiology
container_volume 314
creator Liu, Huanxi
Ma, Songhua
Hu, Tianliang
Ma, Dedong
description Airborne particle pollution causes a range of respiratory and cardiovascular disorders by entering the human respiratory system through the breathing process. The administration of pharmaceutical particles by inhalation is another effective way to treat pulmonary illnesses. Studying particle deposition in the respiratory system during human breathing is crucial to maintaining human health. This necessity served as the impetus for this work, which aims to investigate how the airflow and particles' deposition are influenced by constant inhalation and circulatory breathing, particle diameter, and changes in airflow rate. The focus of this paper is to compare the particle deposition results of circulatory respiration with constant respiration. Based on computed tomography (CT) scan pictures, a precise human airway model from the mouth cavity to the fifth-generation bronchi was created. Flow fields and particle deposition inside the respiratory tract were examined at varied breathing rates (30, 60, and 90 L/min of constant and circulatory breathing) and varying haled particle sizes (5 and 10 µm). The results showed that the oropharyngeal area is often where the majority of particles are deposited. The particle distribution fraction is more significant in the bronchial area than the oropharyngeal region due to lower inhalation velocities and smaller particle sizes. For particles with a diameter of 5 µm, constant respiration and circulatory respiration have virtually identical particle distribution fractions in each region. For particles with a diameter of 10 µm, the particle distribution fraction for circulatory respiration is slightly higher than for constant respiration in the bronchial region as the flow rate increases. For both constant and circulatory respiration, particles are deposited more in the right lung and less in the left. These results contribute to further research on respiratory diseases caused by inhaled particles and guide inhalation therapy for better treatment outcomes. •A realistic model of the human respiratory tract from the oral cavity to the fifth-generation bronchi is reconstructed.•Flow fields and particle deposition are investigated at various breathing states and at different inhaled particle diameters.•The distribution fraction is greater in the bronchi than the oropharynx due to lower velocities and smaller particle sizes.•For both constant and circulatory respiration, particles are deposited more in the right lung and less in the
doi_str_mv 10.1016/j.resp.2023.104085
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2823042491</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1569904823000733</els_id><sourcerecordid>2823042491</sourcerecordid><originalsourceid>FETCH-LOGICAL-c307t-c104800c886cd0e6aaada3abead612d0ca5fef36b40a53d8f2b7a7b3821fc3213</originalsourceid><addsrcrecordid>eNp9kctuFDEQRS1ERF78AAvkJZse_OiHW2KDRgEiRWKTrK1qu5zxqNtu7O5E-RZ-Fs9MYMnK5apzr3R1CfnA2YYz3n7ebxLmeSOYkGVRM9W8IRdcdariDe_flrlp-6pntTonlznvGeMd7-Q7ci470bU9by7I722c5nWBxccAI_XhCfPiH49_Gh11Y3ymZgcJzILJl5vJFIKlM6Qyj0gtzjH7Iz_DUqCQiw0FmhDGo4Du1gnKxqdneKFTtDjSNVhM1HrnMGFY6FDoZefDIzUx2KNdviZnDsaM71_fK_Lw7eZ--6O6-_n9dvv1rjKSdUtlSnbFmFGqNZZhCwAWJAwItuXCMgONQyfboWbQSKucGDroBqkEd0YKLq_Ip5PvnOKvteTXk88GxxECxjVroYRktaj7AypOqEkx54ROz8lPkF40Z_pQit7rQyn6UIo-lVJEH1_912FC-0_yt4UCfDkBWFI-eUw6G4_BoPUJzaJt9P_z_wM846N_</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2823042491</pqid></control><display><type>article</type><title>Computational investigation of flow characteristics and particle deposition patterns in a realistic human airway model under different breathing conditions</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Liu, Huanxi ; Ma, Songhua ; Hu, Tianliang ; Ma, Dedong</creator><creatorcontrib>Liu, Huanxi ; Ma, Songhua ; Hu, Tianliang ; Ma, Dedong</creatorcontrib><description>Airborne particle pollution causes a range of respiratory and cardiovascular disorders by entering the human respiratory system through the breathing process. The administration of pharmaceutical particles by inhalation is another effective way to treat pulmonary illnesses. Studying particle deposition in the respiratory system during human breathing is crucial to maintaining human health. This necessity served as the impetus for this work, which aims to investigate how the airflow and particles' deposition are influenced by constant inhalation and circulatory breathing, particle diameter, and changes in airflow rate. The focus of this paper is to compare the particle deposition results of circulatory respiration with constant respiration. Based on computed tomography (CT) scan pictures, a precise human airway model from the mouth cavity to the fifth-generation bronchi was created. Flow fields and particle deposition inside the respiratory tract were examined at varied breathing rates (30, 60, and 90 L/min of constant and circulatory breathing) and varying haled particle sizes (5 and 10 µm). The results showed that the oropharyngeal area is often where the majority of particles are deposited. The particle distribution fraction is more significant in the bronchial area than the oropharyngeal region due to lower inhalation velocities and smaller particle sizes. For particles with a diameter of 5 µm, constant respiration and circulatory respiration have virtually identical particle distribution fractions in each region. For particles with a diameter of 10 µm, the particle distribution fraction for circulatory respiration is slightly higher than for constant respiration in the bronchial region as the flow rate increases. For both constant and circulatory respiration, particles are deposited more in the right lung and less in the left. These results contribute to further research on respiratory diseases caused by inhaled particles and guide inhalation therapy for better treatment outcomes. •A realistic model of the human respiratory tract from the oral cavity to the fifth-generation bronchi is reconstructed.•Flow fields and particle deposition are investigated at various breathing states and at different inhaled particle diameters.•The distribution fraction is greater in the bronchi than the oropharynx due to lower velocities and smaller particle sizes.•For both constant and circulatory respiration, particles are deposited more in the right lung and less in the left.</description><identifier>ISSN: 1569-9048</identifier><identifier>EISSN: 1878-1519</identifier><identifier>DOI: 10.1016/j.resp.2023.104085</identifier><identifier>PMID: 37276915</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Administration, Inhalation ; Circulatory breathing ; Computational fluid dynamics ; Computer Simulation ; Human respiratory tract ; Humans ; Lung - diagnostic imaging ; Models, Biological ; Particle deposition ; Particle Size ; Respiration ; Respiration Disorders ; Respiratory Aerosols and Droplets</subject><ispartof>Respiratory physiology &amp; neurobiology, 2023-08, Vol.314, p.104085-104085, Article 104085</ispartof><rights>2023 Elsevier B.V.</rights><rights>Copyright © 2023 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c307t-c104800c886cd0e6aaada3abead612d0ca5fef36b40a53d8f2b7a7b3821fc3213</cites><orcidid>0000-0003-4208-2799</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.resp.2023.104085$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37276915$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Liu, Huanxi</creatorcontrib><creatorcontrib>Ma, Songhua</creatorcontrib><creatorcontrib>Hu, Tianliang</creatorcontrib><creatorcontrib>Ma, Dedong</creatorcontrib><title>Computational investigation of flow characteristics and particle deposition patterns in a realistic human airway model under different breathing conditions</title><title>Respiratory physiology &amp; neurobiology</title><addtitle>Respir Physiol Neurobiol</addtitle><description>Airborne particle pollution causes a range of respiratory and cardiovascular disorders by entering the human respiratory system through the breathing process. The administration of pharmaceutical particles by inhalation is another effective way to treat pulmonary illnesses. Studying particle deposition in the respiratory system during human breathing is crucial to maintaining human health. This necessity served as the impetus for this work, which aims to investigate how the airflow and particles' deposition are influenced by constant inhalation and circulatory breathing, particle diameter, and changes in airflow rate. The focus of this paper is to compare the particle deposition results of circulatory respiration with constant respiration. Based on computed tomography (CT) scan pictures, a precise human airway model from the mouth cavity to the fifth-generation bronchi was created. Flow fields and particle deposition inside the respiratory tract were examined at varied breathing rates (30, 60, and 90 L/min of constant and circulatory breathing) and varying haled particle sizes (5 and 10 µm). The results showed that the oropharyngeal area is often where the majority of particles are deposited. The particle distribution fraction is more significant in the bronchial area than the oropharyngeal region due to lower inhalation velocities and smaller particle sizes. For particles with a diameter of 5 µm, constant respiration and circulatory respiration have virtually identical particle distribution fractions in each region. For particles with a diameter of 10 µm, the particle distribution fraction for circulatory respiration is slightly higher than for constant respiration in the bronchial region as the flow rate increases. For both constant and circulatory respiration, particles are deposited more in the right lung and less in the left. These results contribute to further research on respiratory diseases caused by inhaled particles and guide inhalation therapy for better treatment outcomes. •A realistic model of the human respiratory tract from the oral cavity to the fifth-generation bronchi is reconstructed.•Flow fields and particle deposition are investigated at various breathing states and at different inhaled particle diameters.•The distribution fraction is greater in the bronchi than the oropharynx due to lower velocities and smaller particle sizes.•For both constant and circulatory respiration, particles are deposited more in the right lung and less in the left.</description><subject>Administration, Inhalation</subject><subject>Circulatory breathing</subject><subject>Computational fluid dynamics</subject><subject>Computer Simulation</subject><subject>Human respiratory tract</subject><subject>Humans</subject><subject>Lung - diagnostic imaging</subject><subject>Models, Biological</subject><subject>Particle deposition</subject><subject>Particle Size</subject><subject>Respiration</subject><subject>Respiration Disorders</subject><subject>Respiratory Aerosols and Droplets</subject><issn>1569-9048</issn><issn>1878-1519</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kctuFDEQRS1ERF78AAvkJZse_OiHW2KDRgEiRWKTrK1qu5zxqNtu7O5E-RZ-Fs9MYMnK5apzr3R1CfnA2YYz3n7ebxLmeSOYkGVRM9W8IRdcdariDe_flrlp-6pntTonlznvGeMd7-Q7ci470bU9by7I722c5nWBxccAI_XhCfPiH49_Gh11Y3ymZgcJzILJl5vJFIKlM6Qyj0gtzjH7Iz_DUqCQiw0FmhDGo4Du1gnKxqdneKFTtDjSNVhM1HrnMGFY6FDoZefDIzUx2KNdviZnDsaM71_fK_Lw7eZ--6O6-_n9dvv1rjKSdUtlSnbFmFGqNZZhCwAWJAwItuXCMgONQyfboWbQSKucGDroBqkEd0YKLq_Ip5PvnOKvteTXk88GxxECxjVroYRktaj7AypOqEkx54ROz8lPkF40Z_pQit7rQyn6UIo-lVJEH1_912FC-0_yt4UCfDkBWFI-eUw6G4_BoPUJzaJt9P_z_wM846N_</recordid><startdate>202308</startdate><enddate>202308</enddate><creator>Liu, Huanxi</creator><creator>Ma, Songhua</creator><creator>Hu, Tianliang</creator><creator>Ma, Dedong</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4208-2799</orcidid></search><sort><creationdate>202308</creationdate><title>Computational investigation of flow characteristics and particle deposition patterns in a realistic human airway model under different breathing conditions</title><author>Liu, Huanxi ; Ma, Songhua ; Hu, Tianliang ; Ma, Dedong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c307t-c104800c886cd0e6aaada3abead612d0ca5fef36b40a53d8f2b7a7b3821fc3213</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Administration, Inhalation</topic><topic>Circulatory breathing</topic><topic>Computational fluid dynamics</topic><topic>Computer Simulation</topic><topic>Human respiratory tract</topic><topic>Humans</topic><topic>Lung - diagnostic imaging</topic><topic>Models, Biological</topic><topic>Particle deposition</topic><topic>Particle Size</topic><topic>Respiration</topic><topic>Respiration Disorders</topic><topic>Respiratory Aerosols and Droplets</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Liu, Huanxi</creatorcontrib><creatorcontrib>Ma, Songhua</creatorcontrib><creatorcontrib>Hu, Tianliang</creatorcontrib><creatorcontrib>Ma, Dedong</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Respiratory physiology &amp; neurobiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Liu, Huanxi</au><au>Ma, Songhua</au><au>Hu, Tianliang</au><au>Ma, Dedong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computational investigation of flow characteristics and particle deposition patterns in a realistic human airway model under different breathing conditions</atitle><jtitle>Respiratory physiology &amp; neurobiology</jtitle><addtitle>Respir Physiol Neurobiol</addtitle><date>2023-08</date><risdate>2023</risdate><volume>314</volume><spage>104085</spage><epage>104085</epage><pages>104085-104085</pages><artnum>104085</artnum><issn>1569-9048</issn><eissn>1878-1519</eissn><abstract>Airborne particle pollution causes a range of respiratory and cardiovascular disorders by entering the human respiratory system through the breathing process. The administration of pharmaceutical particles by inhalation is another effective way to treat pulmonary illnesses. Studying particle deposition in the respiratory system during human breathing is crucial to maintaining human health. This necessity served as the impetus for this work, which aims to investigate how the airflow and particles' deposition are influenced by constant inhalation and circulatory breathing, particle diameter, and changes in airflow rate. The focus of this paper is to compare the particle deposition results of circulatory respiration with constant respiration. Based on computed tomography (CT) scan pictures, a precise human airway model from the mouth cavity to the fifth-generation bronchi was created. Flow fields and particle deposition inside the respiratory tract were examined at varied breathing rates (30, 60, and 90 L/min of constant and circulatory breathing) and varying haled particle sizes (5 and 10 µm). The results showed that the oropharyngeal area is often where the majority of particles are deposited. The particle distribution fraction is more significant in the bronchial area than the oropharyngeal region due to lower inhalation velocities and smaller particle sizes. For particles with a diameter of 5 µm, constant respiration and circulatory respiration have virtually identical particle distribution fractions in each region. For particles with a diameter of 10 µm, the particle distribution fraction for circulatory respiration is slightly higher than for constant respiration in the bronchial region as the flow rate increases. For both constant and circulatory respiration, particles are deposited more in the right lung and less in the left. These results contribute to further research on respiratory diseases caused by inhaled particles and guide inhalation therapy for better treatment outcomes. •A realistic model of the human respiratory tract from the oral cavity to the fifth-generation bronchi is reconstructed.•Flow fields and particle deposition are investigated at various breathing states and at different inhaled particle diameters.•The distribution fraction is greater in the bronchi than the oropharynx due to lower velocities and smaller particle sizes.•For both constant and circulatory respiration, particles are deposited more in the right lung and less in the left.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>37276915</pmid><doi>10.1016/j.resp.2023.104085</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0003-4208-2799</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1569-9048
ispartof Respiratory physiology & neurobiology, 2023-08, Vol.314, p.104085-104085, Article 104085
issn 1569-9048
1878-1519
language eng
recordid cdi_proquest_miscellaneous_2823042491
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects Administration, Inhalation
Circulatory breathing
Computational fluid dynamics
Computer Simulation
Human respiratory tract
Humans
Lung - diagnostic imaging
Models, Biological
Particle deposition
Particle Size
Respiration
Respiration Disorders
Respiratory Aerosols and Droplets
title Computational investigation of flow characteristics and particle deposition patterns in a realistic human airway model under different breathing conditions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T17%3A40%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computational%20investigation%20of%20flow%20characteristics%20and%20particle%20deposition%20patterns%20in%20a%20realistic%20human%20airway%20model%20under%20different%20breathing%20conditions&rft.jtitle=Respiratory%20physiology%20&%20neurobiology&rft.au=Liu,%20Huanxi&rft.date=2023-08&rft.volume=314&rft.spage=104085&rft.epage=104085&rft.pages=104085-104085&rft.artnum=104085&rft.issn=1569-9048&rft.eissn=1878-1519&rft_id=info:doi/10.1016/j.resp.2023.104085&rft_dat=%3Cproquest_cross%3E2823042491%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2823042491&rft_id=info:pmid/37276915&rft_els_id=S1569904823000733&rfr_iscdi=true