Free Formaldehyde Determination Using HPLC

Release of formaldehyde from durable press treated fabrics is a problem for human health and safety because formaldehyde is suspected to be carcinogen. The accuracy of the standard test method for the free formaldehyde determination, Japan Law 112, depends on the formaldehyde content of the sample....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Materials science forum 2004-01, Vol.455-456, p.801-804
Hauptverfasser: Majcen, Nataša, Bezek, Dominika, Brodnjak Vončina, Darinka, Majcen Le Marechal, Alenka, Voncina, Bojana
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 804
container_issue
container_start_page 801
container_title Materials science forum
container_volume 455-456
creator Majcen, Nataša
Bezek, Dominika
Brodnjak Vončina, Darinka
Majcen Le Marechal, Alenka
Voncina, Bojana
description Release of formaldehyde from durable press treated fabrics is a problem for human health and safety because formaldehyde is suspected to be carcinogen. The accuracy of the standard test method for the free formaldehyde determination, Japan Law 112, depends on the formaldehyde content of the sample. The formaldehyde contents below 20 *mg/g cannot be shown to be caused by formaldehyde. The detection of low formaldehyde contents is important particularly in some fields, like children clothing, so the High Performance Liquid Chromatography was used. With different crosslinking reagents finished textile substrates were extracted with water to detect the free formaldehyde by an acetylacetone method. The results obtained by the standard test method, Japan Law 112, where UV/VIS spectrometer was used, were compared with the results obtained by HPLC method where separation was performed on RP C 18 column with water: MeOH as a mobile phase. It was shown that the detection limit and limit of quantification were improved using HPLC method. Concentration range obtained by HPLC method is from 0.3 *mg/g to 3000 *mg/g.
doi_str_mv 10.4028/www.scientific.net/MSF.455-456.801
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_28204214</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>28204214</sourcerecordid><originalsourceid>FETCH-LOGICAL-c410t-d64f1d4390050dc93af8dc2d10ab49bbf2e5153e9475545927eeb0da04b55b263</originalsourceid><addsrcrecordid>eNqV0EFLwzAUB_AgCs7pd-jJw6BdkiZpe9RpnTBR0J1D2ry6jDadScbYtzcywbOHxzu8P394P4RmBGcM03J-OBwy3xqwwXSmzSyE-ct7nTHOU8ZFVmJyhiZECJpWBafnaIJpPHFWiEt05f0W45yUREzQrHYAST26QfUaNkcNyQMEcIOxKpjRJmtv7GeyfFstrtFFp3oPN797itb148dima5en54Xd6u0ZQSHVAvWEc3yCmOOdVvlqit1SzXBqmFV03QUOOE5VKzgnPGKFgAN1gqzhvOGinyKbk-9Ozd-7cEHORjfQt8rC-PeS1pSzChhMXh_CrZu9N5BJ3fODModJcHyh0lGJvnHJCOTjEwyMsURMjLFkodTSXDK-gDtRm7HvbPxw__UfAOZ2nnu</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28204214</pqid></control><display><type>article</type><title>Free Formaldehyde Determination Using HPLC</title><source>Scientific.net Journals</source><creator>Majcen, Nataša ; Bezek, Dominika ; Brodnjak Vončina, Darinka ; Majcen Le Marechal, Alenka ; Voncina, Bojana</creator><creatorcontrib>Majcen, Nataša ; Bezek, Dominika ; Brodnjak Vončina, Darinka ; Majcen Le Marechal, Alenka ; Voncina, Bojana</creatorcontrib><description>Release of formaldehyde from durable press treated fabrics is a problem for human health and safety because formaldehyde is suspected to be carcinogen. The accuracy of the standard test method for the free formaldehyde determination, Japan Law 112, depends on the formaldehyde content of the sample. The formaldehyde contents below 20 *mg/g cannot be shown to be caused by formaldehyde. The detection of low formaldehyde contents is important particularly in some fields, like children clothing, so the High Performance Liquid Chromatography was used. With different crosslinking reagents finished textile substrates were extracted with water to detect the free formaldehyde by an acetylacetone method. The results obtained by the standard test method, Japan Law 112, where UV/VIS spectrometer was used, were compared with the results obtained by HPLC method where separation was performed on RP C 18 column with water: MeOH as a mobile phase. It was shown that the detection limit and limit of quantification were improved using HPLC method. Concentration range obtained by HPLC method is from 0.3 *mg/g to 3000 *mg/g.</description><identifier>ISSN: 0255-5476</identifier><identifier>ISSN: 1662-9752</identifier><identifier>EISSN: 1662-9752</identifier><identifier>DOI: 10.4028/www.scientific.net/MSF.455-456.801</identifier><language>eng</language><publisher>Trans Tech Publications Ltd</publisher><ispartof>Materials science forum, 2004-01, Vol.455-456, p.801-804</ispartof><rights>2004 Trans Tech Publications Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c410t-d64f1d4390050dc93af8dc2d10ab49bbf2e5153e9475545927eeb0da04b55b263</citedby><cites>FETCH-LOGICAL-c410t-d64f1d4390050dc93af8dc2d10ab49bbf2e5153e9475545927eeb0da04b55b263</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/491?width=600</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Majcen, Nataša</creatorcontrib><creatorcontrib>Bezek, Dominika</creatorcontrib><creatorcontrib>Brodnjak Vončina, Darinka</creatorcontrib><creatorcontrib>Majcen Le Marechal, Alenka</creatorcontrib><creatorcontrib>Voncina, Bojana</creatorcontrib><title>Free Formaldehyde Determination Using HPLC</title><title>Materials science forum</title><description>Release of formaldehyde from durable press treated fabrics is a problem for human health and safety because formaldehyde is suspected to be carcinogen. The accuracy of the standard test method for the free formaldehyde determination, Japan Law 112, depends on the formaldehyde content of the sample. The formaldehyde contents below 20 *mg/g cannot be shown to be caused by formaldehyde. The detection of low formaldehyde contents is important particularly in some fields, like children clothing, so the High Performance Liquid Chromatography was used. With different crosslinking reagents finished textile substrates were extracted with water to detect the free formaldehyde by an acetylacetone method. The results obtained by the standard test method, Japan Law 112, where UV/VIS spectrometer was used, were compared with the results obtained by HPLC method where separation was performed on RP C 18 column with water: MeOH as a mobile phase. It was shown that the detection limit and limit of quantification were improved using HPLC method. Concentration range obtained by HPLC method is from 0.3 *mg/g to 3000 *mg/g.</description><issn>0255-5476</issn><issn>1662-9752</issn><issn>1662-9752</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNqV0EFLwzAUB_AgCs7pd-jJw6BdkiZpe9RpnTBR0J1D2ry6jDadScbYtzcywbOHxzu8P394P4RmBGcM03J-OBwy3xqwwXSmzSyE-ct7nTHOU8ZFVmJyhiZECJpWBafnaIJpPHFWiEt05f0W45yUREzQrHYAST26QfUaNkcNyQMEcIOxKpjRJmtv7GeyfFstrtFFp3oPN797itb148dima5en54Xd6u0ZQSHVAvWEc3yCmOOdVvlqit1SzXBqmFV03QUOOE5VKzgnPGKFgAN1gqzhvOGinyKbk-9Ozd-7cEHORjfQt8rC-PeS1pSzChhMXh_CrZu9N5BJ3fODModJcHyh0lGJvnHJCOTjEwyMsURMjLFkodTSXDK-gDtRm7HvbPxw__UfAOZ2nnu</recordid><startdate>20040101</startdate><enddate>20040101</enddate><creator>Majcen, Nataša</creator><creator>Bezek, Dominika</creator><creator>Brodnjak Vončina, Darinka</creator><creator>Majcen Le Marechal, Alenka</creator><creator>Voncina, Bojana</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>20040101</creationdate><title>Free Formaldehyde Determination Using HPLC</title><author>Majcen, Nataša ; Bezek, Dominika ; Brodnjak Vončina, Darinka ; Majcen Le Marechal, Alenka ; Voncina, Bojana</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c410t-d64f1d4390050dc93af8dc2d10ab49bbf2e5153e9475545927eeb0da04b55b263</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Majcen, Nataša</creatorcontrib><creatorcontrib>Bezek, Dominika</creatorcontrib><creatorcontrib>Brodnjak Vončina, Darinka</creatorcontrib><creatorcontrib>Majcen Le Marechal, Alenka</creatorcontrib><creatorcontrib>Voncina, Bojana</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Materials science forum</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Majcen, Nataša</au><au>Bezek, Dominika</au><au>Brodnjak Vončina, Darinka</au><au>Majcen Le Marechal, Alenka</au><au>Voncina, Bojana</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Free Formaldehyde Determination Using HPLC</atitle><jtitle>Materials science forum</jtitle><date>2004-01-01</date><risdate>2004</risdate><volume>455-456</volume><spage>801</spage><epage>804</epage><pages>801-804</pages><issn>0255-5476</issn><issn>1662-9752</issn><eissn>1662-9752</eissn><abstract>Release of formaldehyde from durable press treated fabrics is a problem for human health and safety because formaldehyde is suspected to be carcinogen. The accuracy of the standard test method for the free formaldehyde determination, Japan Law 112, depends on the formaldehyde content of the sample. The formaldehyde contents below 20 *mg/g cannot be shown to be caused by formaldehyde. The detection of low formaldehyde contents is important particularly in some fields, like children clothing, so the High Performance Liquid Chromatography was used. With different crosslinking reagents finished textile substrates were extracted with water to detect the free formaldehyde by an acetylacetone method. The results obtained by the standard test method, Japan Law 112, where UV/VIS spectrometer was used, were compared with the results obtained by HPLC method where separation was performed on RP C 18 column with water: MeOH as a mobile phase. It was shown that the detection limit and limit of quantification were improved using HPLC method. Concentration range obtained by HPLC method is from 0.3 *mg/g to 3000 *mg/g.</abstract><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/MSF.455-456.801</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0255-5476
ispartof Materials science forum, 2004-01, Vol.455-456, p.801-804
issn 0255-5476
1662-9752
1662-9752
language eng
recordid cdi_proquest_miscellaneous_28204214
source Scientific.net Journals
title Free Formaldehyde Determination Using HPLC
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T12%3A29%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Free%20Formaldehyde%20Determination%20Using%20HPLC&rft.jtitle=Materials%20science%20forum&rft.au=Majcen,%20Nata%C5%A1a&rft.date=2004-01-01&rft.volume=455-456&rft.spage=801&rft.epage=804&rft.pages=801-804&rft.issn=0255-5476&rft.eissn=1662-9752&rft_id=info:doi/10.4028/www.scientific.net/MSF.455-456.801&rft_dat=%3Cproquest_cross%3E28204214%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=28204214&rft_id=info:pmid/&rfr_iscdi=true