Free Formaldehyde Determination Using HPLC
Release of formaldehyde from durable press treated fabrics is a problem for human health and safety because formaldehyde is suspected to be carcinogen. The accuracy of the standard test method for the free formaldehyde determination, Japan Law 112, depends on the formaldehyde content of the sample....
Gespeichert in:
Veröffentlicht in: | Materials science forum 2004-01, Vol.455-456, p.801-804 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 804 |
---|---|
container_issue | |
container_start_page | 801 |
container_title | Materials science forum |
container_volume | 455-456 |
creator | Majcen, Nataša Bezek, Dominika Brodnjak Vončina, Darinka Majcen Le Marechal, Alenka Voncina, Bojana |
description | Release of formaldehyde from durable press treated fabrics is a problem for human health and safety because formaldehyde is suspected to be carcinogen. The accuracy of the standard test method for the free formaldehyde determination, Japan Law 112, depends on the formaldehyde content of the sample. The formaldehyde contents below 20 *mg/g cannot be shown to be caused by formaldehyde. The detection of low formaldehyde contents is important particularly in some fields, like children clothing, so the High Performance Liquid Chromatography was used. With different crosslinking reagents finished textile substrates were extracted with water to detect the free formaldehyde by an acetylacetone method. The results obtained by the standard test method, Japan Law 112, where UV/VIS spectrometer was used, were compared with the results obtained by HPLC method where separation was performed on RP C 18 column with water: MeOH as a mobile phase. It was shown that the detection limit and limit of quantification were improved using HPLC method. Concentration range obtained by HPLC method is from 0.3 *mg/g to 3000 *mg/g. |
doi_str_mv | 10.4028/www.scientific.net/MSF.455-456.801 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_28204214</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>28204214</sourcerecordid><originalsourceid>FETCH-LOGICAL-c410t-d64f1d4390050dc93af8dc2d10ab49bbf2e5153e9475545927eeb0da04b55b263</originalsourceid><addsrcrecordid>eNqV0EFLwzAUB_AgCs7pd-jJw6BdkiZpe9RpnTBR0J1D2ry6jDadScbYtzcywbOHxzu8P394P4RmBGcM03J-OBwy3xqwwXSmzSyE-ct7nTHOU8ZFVmJyhiZECJpWBafnaIJpPHFWiEt05f0W45yUREzQrHYAST26QfUaNkcNyQMEcIOxKpjRJmtv7GeyfFstrtFFp3oPN797itb148dima5en54Xd6u0ZQSHVAvWEc3yCmOOdVvlqit1SzXBqmFV03QUOOE5VKzgnPGKFgAN1gqzhvOGinyKbk-9Ozd-7cEHORjfQt8rC-PeS1pSzChhMXh_CrZu9N5BJ3fODModJcHyh0lGJvnHJCOTjEwyMsURMjLFkodTSXDK-gDtRm7HvbPxw__UfAOZ2nnu</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28204214</pqid></control><display><type>article</type><title>Free Formaldehyde Determination Using HPLC</title><source>Scientific.net Journals</source><creator>Majcen, Nataša ; Bezek, Dominika ; Brodnjak Vončina, Darinka ; Majcen Le Marechal, Alenka ; Voncina, Bojana</creator><creatorcontrib>Majcen, Nataša ; Bezek, Dominika ; Brodnjak Vončina, Darinka ; Majcen Le Marechal, Alenka ; Voncina, Bojana</creatorcontrib><description>Release of formaldehyde from durable press treated fabrics is a problem for human health and safety because formaldehyde is suspected to be carcinogen. The accuracy of the standard test method for the free formaldehyde determination, Japan Law 112, depends on the formaldehyde content of the sample. The formaldehyde contents below 20 *mg/g cannot be shown to be caused by formaldehyde. The detection of low formaldehyde contents is important particularly in some fields, like children clothing, so the High Performance Liquid Chromatography was used. With different crosslinking reagents finished textile substrates were extracted with water to detect the free formaldehyde by an acetylacetone method. The results obtained by the standard test method, Japan Law 112, where UV/VIS spectrometer was used, were compared with the results obtained by HPLC method where separation was performed on RP C 18 column with water: MeOH as a mobile phase. It was shown that the detection limit and limit of quantification were improved using HPLC method. Concentration range obtained by HPLC method is from 0.3 *mg/g to 3000 *mg/g.</description><identifier>ISSN: 0255-5476</identifier><identifier>ISSN: 1662-9752</identifier><identifier>EISSN: 1662-9752</identifier><identifier>DOI: 10.4028/www.scientific.net/MSF.455-456.801</identifier><language>eng</language><publisher>Trans Tech Publications Ltd</publisher><ispartof>Materials science forum, 2004-01, Vol.455-456, p.801-804</ispartof><rights>2004 Trans Tech Publications Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c410t-d64f1d4390050dc93af8dc2d10ab49bbf2e5153e9475545927eeb0da04b55b263</citedby><cites>FETCH-LOGICAL-c410t-d64f1d4390050dc93af8dc2d10ab49bbf2e5153e9475545927eeb0da04b55b263</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/491?width=600</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Majcen, Nataša</creatorcontrib><creatorcontrib>Bezek, Dominika</creatorcontrib><creatorcontrib>Brodnjak Vončina, Darinka</creatorcontrib><creatorcontrib>Majcen Le Marechal, Alenka</creatorcontrib><creatorcontrib>Voncina, Bojana</creatorcontrib><title>Free Formaldehyde Determination Using HPLC</title><title>Materials science forum</title><description>Release of formaldehyde from durable press treated fabrics is a problem for human health and safety because formaldehyde is suspected to be carcinogen. The accuracy of the standard test method for the free formaldehyde determination, Japan Law 112, depends on the formaldehyde content of the sample. The formaldehyde contents below 20 *mg/g cannot be shown to be caused by formaldehyde. The detection of low formaldehyde contents is important particularly in some fields, like children clothing, so the High Performance Liquid Chromatography was used. With different crosslinking reagents finished textile substrates were extracted with water to detect the free formaldehyde by an acetylacetone method. The results obtained by the standard test method, Japan Law 112, where UV/VIS spectrometer was used, were compared with the results obtained by HPLC method where separation was performed on RP C 18 column with water: MeOH as a mobile phase. It was shown that the detection limit and limit of quantification were improved using HPLC method. Concentration range obtained by HPLC method is from 0.3 *mg/g to 3000 *mg/g.</description><issn>0255-5476</issn><issn>1662-9752</issn><issn>1662-9752</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNqV0EFLwzAUB_AgCs7pd-jJw6BdkiZpe9RpnTBR0J1D2ry6jDadScbYtzcywbOHxzu8P394P4RmBGcM03J-OBwy3xqwwXSmzSyE-ct7nTHOU8ZFVmJyhiZECJpWBafnaIJpPHFWiEt05f0W45yUREzQrHYAST26QfUaNkcNyQMEcIOxKpjRJmtv7GeyfFstrtFFp3oPN797itb148dima5en54Xd6u0ZQSHVAvWEc3yCmOOdVvlqit1SzXBqmFV03QUOOE5VKzgnPGKFgAN1gqzhvOGinyKbk-9Ozd-7cEHORjfQt8rC-PeS1pSzChhMXh_CrZu9N5BJ3fODModJcHyh0lGJvnHJCOTjEwyMsURMjLFkodTSXDK-gDtRm7HvbPxw__UfAOZ2nnu</recordid><startdate>20040101</startdate><enddate>20040101</enddate><creator>Majcen, Nataša</creator><creator>Bezek, Dominika</creator><creator>Brodnjak Vončina, Darinka</creator><creator>Majcen Le Marechal, Alenka</creator><creator>Voncina, Bojana</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>20040101</creationdate><title>Free Formaldehyde Determination Using HPLC</title><author>Majcen, Nataša ; Bezek, Dominika ; Brodnjak Vončina, Darinka ; Majcen Le Marechal, Alenka ; Voncina, Bojana</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c410t-d64f1d4390050dc93af8dc2d10ab49bbf2e5153e9475545927eeb0da04b55b263</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Majcen, Nataša</creatorcontrib><creatorcontrib>Bezek, Dominika</creatorcontrib><creatorcontrib>Brodnjak Vončina, Darinka</creatorcontrib><creatorcontrib>Majcen Le Marechal, Alenka</creatorcontrib><creatorcontrib>Voncina, Bojana</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Materials science forum</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Majcen, Nataša</au><au>Bezek, Dominika</au><au>Brodnjak Vončina, Darinka</au><au>Majcen Le Marechal, Alenka</au><au>Voncina, Bojana</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Free Formaldehyde Determination Using HPLC</atitle><jtitle>Materials science forum</jtitle><date>2004-01-01</date><risdate>2004</risdate><volume>455-456</volume><spage>801</spage><epage>804</epage><pages>801-804</pages><issn>0255-5476</issn><issn>1662-9752</issn><eissn>1662-9752</eissn><abstract>Release of formaldehyde from durable press treated fabrics is a problem for human health and safety because formaldehyde is suspected to be carcinogen. The accuracy of the standard test method for the free formaldehyde determination, Japan Law 112, depends on the formaldehyde content of the sample. The formaldehyde contents below 20 *mg/g cannot be shown to be caused by formaldehyde. The detection of low formaldehyde contents is important particularly in some fields, like children clothing, so the High Performance Liquid Chromatography was used. With different crosslinking reagents finished textile substrates were extracted with water to detect the free formaldehyde by an acetylacetone method. The results obtained by the standard test method, Japan Law 112, where UV/VIS spectrometer was used, were compared with the results obtained by HPLC method where separation was performed on RP C 18 column with water: MeOH as a mobile phase. It was shown that the detection limit and limit of quantification were improved using HPLC method. Concentration range obtained by HPLC method is from 0.3 *mg/g to 3000 *mg/g.</abstract><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/MSF.455-456.801</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0255-5476 |
ispartof | Materials science forum, 2004-01, Vol.455-456, p.801-804 |
issn | 0255-5476 1662-9752 1662-9752 |
language | eng |
recordid | cdi_proquest_miscellaneous_28204214 |
source | Scientific.net Journals |
title | Free Formaldehyde Determination Using HPLC |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T12%3A29%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Free%20Formaldehyde%20Determination%20Using%20HPLC&rft.jtitle=Materials%20science%20forum&rft.au=Majcen,%20Nata%C5%A1a&rft.date=2004-01-01&rft.volume=455-456&rft.spage=801&rft.epage=804&rft.pages=801-804&rft.issn=0255-5476&rft.eissn=1662-9752&rft_id=info:doi/10.4028/www.scientific.net/MSF.455-456.801&rft_dat=%3Cproquest_cross%3E28204214%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=28204214&rft_id=info:pmid/&rfr_iscdi=true |