Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study

Trapeziometacarpal arthrodesis is used for the treatment of advanced arthritis. Insufficient stabilization of the joint may lead to nonunion or hardware problems after arthrodesis. The purpose of this study was to compare the biomechanical properties of dorsal versus radial plate fixation of the tra...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of hand surgery, European volume European volume, 2023-10, Vol.48 (9), p.872-876
Hauptverfasser: Cho, Jae-Yong, Lim, Joon-Ryul, Oh, Won-Taek, Koh, Il-Hyun, Chun, Yong-Min, Choi, Yun-Rak
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 876
container_issue 9
container_start_page 872
container_title The Journal of hand surgery, European volume
container_volume 48
creator Cho, Jae-Yong
Lim, Joon-Ryul
Oh, Won-Taek
Koh, Il-Hyun
Chun, Yong-Min
Choi, Yun-Rak
description Trapeziometacarpal arthrodesis is used for the treatment of advanced arthritis. Insufficient stabilization of the joint may lead to nonunion or hardware problems after arthrodesis. The purpose of this study was to compare the biomechanical properties of dorsal versus radial plate fixation of the trapeziometacarpal joint in ten pairs of fresh-frozen cadaveric hands. The biomechanical performance of each group was measured for stiffness in extension and flexion and load to failure using cantilever bending tests. The stiffness in extension was lower in the dorsally positioned group than in the radially positioned group (12.1 versus 15.2 N/mm, respectively). Load to failure was comparable between both groups (53.9 versus 50.9 N, respectively). A radially positioned locking plate for trapeziometacarpal arthrodesis may be biomechanically advantageous.
doi_str_mv 10.1177/17531934231176656
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2819277447</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_17531934231176656</sage_id><sourcerecordid>2819277447</sourcerecordid><originalsourceid>FETCH-LOGICAL-c292t-997523e60002a78ff94e722162abd79bac53e4739c4428be023599c9d25412653</originalsourceid><addsrcrecordid>eNp9kEtLw0AUhQdRbK3-ADeSpZvUeU_GnYgvKAii63AzmbQpSSfOJIX6653Q6kZwdTnc7xzuPQhdEjwnRKkbogQjmnHKopRSyCM0pZizVNJMH6PpuE9HYILOQlhjLDJN5CmaMEWp5FJNUfEGZQ1NsrU-DCEpnQ9RdQ309WaZVM4nvYfOftWutT0Y8F1cg-9X3pU21OE2gcS4tgMfHVubFCNoVrCpTQRDP5S7c3RSQRPsxWHO0Mfjw_v9c7p4fXq5v1ukhmrap1orQZmVGGMKKqsqzW08k0gKRal0AUYwyxXThnOaFRZTJrQ2uqSCEyoFm6HrfW7n3edgQ5-3dTC2aWBj3RBymhFNleIxY4bIHjXeheBtlXe-bsHvcoLzsdr8T7XRc3WIH4rWlr-Ony4jMN8DAZY2X7vBb-K7_yR-A4-wgWM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2819277447</pqid></control><display><type>article</type><title>Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study</title><source>Access via SAGE</source><source>Alma/SFX Local Collection</source><creator>Cho, Jae-Yong ; Lim, Joon-Ryul ; Oh, Won-Taek ; Koh, Il-Hyun ; Chun, Yong-Min ; Choi, Yun-Rak</creator><creatorcontrib>Cho, Jae-Yong ; Lim, Joon-Ryul ; Oh, Won-Taek ; Koh, Il-Hyun ; Chun, Yong-Min ; Choi, Yun-Rak</creatorcontrib><description>Trapeziometacarpal arthrodesis is used for the treatment of advanced arthritis. Insufficient stabilization of the joint may lead to nonunion or hardware problems after arthrodesis. The purpose of this study was to compare the biomechanical properties of dorsal versus radial plate fixation of the trapeziometacarpal joint in ten pairs of fresh-frozen cadaveric hands. The biomechanical performance of each group was measured for stiffness in extension and flexion and load to failure using cantilever bending tests. The stiffness in extension was lower in the dorsally positioned group than in the radially positioned group (12.1 versus 15.2 N/mm, respectively). Load to failure was comparable between both groups (53.9 versus 50.9 N, respectively). A radially positioned locking plate for trapeziometacarpal arthrodesis may be biomechanically advantageous.</description><identifier>ISSN: 1753-1934</identifier><identifier>EISSN: 2043-6289</identifier><identifier>DOI: 10.1177/17531934231176656</identifier><identifier>PMID: 37226467</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>The Journal of hand surgery, European volume, 2023-10, Vol.48 (9), p.872-876</ispartof><rights>The Author(s) 2023</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c292t-997523e60002a78ff94e722162abd79bac53e4739c4428be023599c9d25412653</cites><orcidid>0000-0002-6729-9292 ; 0000-0001-5197-3716</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/17531934231176656$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/17531934231176656$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37226467$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cho, Jae-Yong</creatorcontrib><creatorcontrib>Lim, Joon-Ryul</creatorcontrib><creatorcontrib>Oh, Won-Taek</creatorcontrib><creatorcontrib>Koh, Il-Hyun</creatorcontrib><creatorcontrib>Chun, Yong-Min</creatorcontrib><creatorcontrib>Choi, Yun-Rak</creatorcontrib><title>Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study</title><title>The Journal of hand surgery, European volume</title><addtitle>J Hand Surg Eur Vol</addtitle><description>Trapeziometacarpal arthrodesis is used for the treatment of advanced arthritis. Insufficient stabilization of the joint may lead to nonunion or hardware problems after arthrodesis. The purpose of this study was to compare the biomechanical properties of dorsal versus radial plate fixation of the trapeziometacarpal joint in ten pairs of fresh-frozen cadaveric hands. The biomechanical performance of each group was measured for stiffness in extension and flexion and load to failure using cantilever bending tests. The stiffness in extension was lower in the dorsally positioned group than in the radially positioned group (12.1 versus 15.2 N/mm, respectively). Load to failure was comparable between both groups (53.9 versus 50.9 N, respectively). A radially positioned locking plate for trapeziometacarpal arthrodesis may be biomechanically advantageous.</description><issn>1753-1934</issn><issn>2043-6289</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kEtLw0AUhQdRbK3-ADeSpZvUeU_GnYgvKAii63AzmbQpSSfOJIX6653Q6kZwdTnc7xzuPQhdEjwnRKkbogQjmnHKopRSyCM0pZizVNJMH6PpuE9HYILOQlhjLDJN5CmaMEWp5FJNUfEGZQ1NsrU-DCEpnQ9RdQ309WaZVM4nvYfOftWutT0Y8F1cg-9X3pU21OE2gcS4tgMfHVubFCNoVrCpTQRDP5S7c3RSQRPsxWHO0Mfjw_v9c7p4fXq5v1ukhmrap1orQZmVGGMKKqsqzW08k0gKRal0AUYwyxXThnOaFRZTJrQ2uqSCEyoFm6HrfW7n3edgQ5-3dTC2aWBj3RBymhFNleIxY4bIHjXeheBtlXe-bsHvcoLzsdr8T7XRc3WIH4rWlr-Ony4jMN8DAZY2X7vBb-K7_yR-A4-wgWM</recordid><startdate>20231001</startdate><enddate>20231001</enddate><creator>Cho, Jae-Yong</creator><creator>Lim, Joon-Ryul</creator><creator>Oh, Won-Taek</creator><creator>Koh, Il-Hyun</creator><creator>Chun, Yong-Min</creator><creator>Choi, Yun-Rak</creator><general>SAGE Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-6729-9292</orcidid><orcidid>https://orcid.org/0000-0001-5197-3716</orcidid></search><sort><creationdate>20231001</creationdate><title>Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study</title><author>Cho, Jae-Yong ; Lim, Joon-Ryul ; Oh, Won-Taek ; Koh, Il-Hyun ; Chun, Yong-Min ; Choi, Yun-Rak</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c292t-997523e60002a78ff94e722162abd79bac53e4739c4428be023599c9d25412653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cho, Jae-Yong</creatorcontrib><creatorcontrib>Lim, Joon-Ryul</creatorcontrib><creatorcontrib>Oh, Won-Taek</creatorcontrib><creatorcontrib>Koh, Il-Hyun</creatorcontrib><creatorcontrib>Chun, Yong-Min</creatorcontrib><creatorcontrib>Choi, Yun-Rak</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of hand surgery, European volume</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cho, Jae-Yong</au><au>Lim, Joon-Ryul</au><au>Oh, Won-Taek</au><au>Koh, Il-Hyun</au><au>Chun, Yong-Min</au><au>Choi, Yun-Rak</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study</atitle><jtitle>The Journal of hand surgery, European volume</jtitle><addtitle>J Hand Surg Eur Vol</addtitle><date>2023-10-01</date><risdate>2023</risdate><volume>48</volume><issue>9</issue><spage>872</spage><epage>876</epage><pages>872-876</pages><issn>1753-1934</issn><eissn>2043-6289</eissn><abstract>Trapeziometacarpal arthrodesis is used for the treatment of advanced arthritis. Insufficient stabilization of the joint may lead to nonunion or hardware problems after arthrodesis. The purpose of this study was to compare the biomechanical properties of dorsal versus radial plate fixation of the trapeziometacarpal joint in ten pairs of fresh-frozen cadaveric hands. The biomechanical performance of each group was measured for stiffness in extension and flexion and load to failure using cantilever bending tests. The stiffness in extension was lower in the dorsally positioned group than in the radially positioned group (12.1 versus 15.2 N/mm, respectively). Load to failure was comparable between both groups (53.9 versus 50.9 N, respectively). A radially positioned locking plate for trapeziometacarpal arthrodesis may be biomechanically advantageous.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>37226467</pmid><doi>10.1177/17531934231176656</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0002-6729-9292</orcidid><orcidid>https://orcid.org/0000-0001-5197-3716</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1753-1934
ispartof The Journal of hand surgery, European volume, 2023-10, Vol.48 (9), p.872-876
issn 1753-1934
2043-6289
language eng
recordid cdi_proquest_miscellaneous_2819277447
source Access via SAGE; Alma/SFX Local Collection
title Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T13%3A05%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Radial%20versus%20dorsal%20plating%20for%20trapeziometacarpal%20arthrodesis:%20a%20comparative%20biomechanical%20study&rft.jtitle=The%20Journal%20of%20hand%20surgery,%20European%20volume&rft.au=Cho,%20Jae-Yong&rft.date=2023-10-01&rft.volume=48&rft.issue=9&rft.spage=872&rft.epage=876&rft.pages=872-876&rft.issn=1753-1934&rft.eissn=2043-6289&rft_id=info:doi/10.1177/17531934231176656&rft_dat=%3Cproquest_cross%3E2819277447%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2819277447&rft_id=info:pmid/37226467&rft_sage_id=10.1177_17531934231176656&rfr_iscdi=true