Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study
Trapeziometacarpal arthrodesis is used for the treatment of advanced arthritis. Insufficient stabilization of the joint may lead to nonunion or hardware problems after arthrodesis. The purpose of this study was to compare the biomechanical properties of dorsal versus radial plate fixation of the tra...
Gespeichert in:
Veröffentlicht in: | The Journal of hand surgery, European volume European volume, 2023-10, Vol.48 (9), p.872-876 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 876 |
---|---|
container_issue | 9 |
container_start_page | 872 |
container_title | The Journal of hand surgery, European volume |
container_volume | 48 |
creator | Cho, Jae-Yong Lim, Joon-Ryul Oh, Won-Taek Koh, Il-Hyun Chun, Yong-Min Choi, Yun-Rak |
description | Trapeziometacarpal arthrodesis is used for the treatment of advanced arthritis. Insufficient stabilization of the joint may lead to nonunion or hardware problems after arthrodesis. The purpose of this study was to compare the biomechanical properties of dorsal versus radial plate fixation of the trapeziometacarpal joint in ten pairs of fresh-frozen cadaveric hands. The biomechanical performance of each group was measured for stiffness in extension and flexion and load to failure using cantilever bending tests. The stiffness in extension was lower in the dorsally positioned group than in the radially positioned group (12.1 versus 15.2 N/mm, respectively). Load to failure was comparable between both groups (53.9 versus 50.9 N, respectively). A radially positioned locking plate for trapeziometacarpal arthrodesis may be biomechanically advantageous. |
doi_str_mv | 10.1177/17531934231176656 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2819277447</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_17531934231176656</sage_id><sourcerecordid>2819277447</sourcerecordid><originalsourceid>FETCH-LOGICAL-c292t-997523e60002a78ff94e722162abd79bac53e4739c4428be023599c9d25412653</originalsourceid><addsrcrecordid>eNp9kEtLw0AUhQdRbK3-ADeSpZvUeU_GnYgvKAii63AzmbQpSSfOJIX6653Q6kZwdTnc7xzuPQhdEjwnRKkbogQjmnHKopRSyCM0pZizVNJMH6PpuE9HYILOQlhjLDJN5CmaMEWp5FJNUfEGZQ1NsrU-DCEpnQ9RdQ309WaZVM4nvYfOftWutT0Y8F1cg-9X3pU21OE2gcS4tgMfHVubFCNoVrCpTQRDP5S7c3RSQRPsxWHO0Mfjw_v9c7p4fXq5v1ukhmrap1orQZmVGGMKKqsqzW08k0gKRal0AUYwyxXThnOaFRZTJrQ2uqSCEyoFm6HrfW7n3edgQ5-3dTC2aWBj3RBymhFNleIxY4bIHjXeheBtlXe-bsHvcoLzsdr8T7XRc3WIH4rWlr-Ony4jMN8DAZY2X7vBb-K7_yR-A4-wgWM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2819277447</pqid></control><display><type>article</type><title>Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study</title><source>Access via SAGE</source><source>Alma/SFX Local Collection</source><creator>Cho, Jae-Yong ; Lim, Joon-Ryul ; Oh, Won-Taek ; Koh, Il-Hyun ; Chun, Yong-Min ; Choi, Yun-Rak</creator><creatorcontrib>Cho, Jae-Yong ; Lim, Joon-Ryul ; Oh, Won-Taek ; Koh, Il-Hyun ; Chun, Yong-Min ; Choi, Yun-Rak</creatorcontrib><description>Trapeziometacarpal arthrodesis is used for the treatment of advanced arthritis. Insufficient stabilization of the joint may lead to nonunion or hardware problems after arthrodesis. The purpose of this study was to compare the biomechanical properties of dorsal versus radial plate fixation of the trapeziometacarpal joint in ten pairs of fresh-frozen cadaveric hands. The biomechanical performance of each group was measured for stiffness in extension and flexion and load to failure using cantilever bending tests. The stiffness in extension was lower in the dorsally positioned group than in the radially positioned group (12.1 versus 15.2 N/mm, respectively). Load to failure was comparable between both groups (53.9 versus 50.9 N, respectively). A radially positioned locking plate for trapeziometacarpal arthrodesis may be biomechanically advantageous.</description><identifier>ISSN: 1753-1934</identifier><identifier>EISSN: 2043-6289</identifier><identifier>DOI: 10.1177/17531934231176656</identifier><identifier>PMID: 37226467</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>The Journal of hand surgery, European volume, 2023-10, Vol.48 (9), p.872-876</ispartof><rights>The Author(s) 2023</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c292t-997523e60002a78ff94e722162abd79bac53e4739c4428be023599c9d25412653</cites><orcidid>0000-0002-6729-9292 ; 0000-0001-5197-3716</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/17531934231176656$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/17531934231176656$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37226467$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cho, Jae-Yong</creatorcontrib><creatorcontrib>Lim, Joon-Ryul</creatorcontrib><creatorcontrib>Oh, Won-Taek</creatorcontrib><creatorcontrib>Koh, Il-Hyun</creatorcontrib><creatorcontrib>Chun, Yong-Min</creatorcontrib><creatorcontrib>Choi, Yun-Rak</creatorcontrib><title>Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study</title><title>The Journal of hand surgery, European volume</title><addtitle>J Hand Surg Eur Vol</addtitle><description>Trapeziometacarpal arthrodesis is used for the treatment of advanced arthritis. Insufficient stabilization of the joint may lead to nonunion or hardware problems after arthrodesis. The purpose of this study was to compare the biomechanical properties of dorsal versus radial plate fixation of the trapeziometacarpal joint in ten pairs of fresh-frozen cadaveric hands. The biomechanical performance of each group was measured for stiffness in extension and flexion and load to failure using cantilever bending tests. The stiffness in extension was lower in the dorsally positioned group than in the radially positioned group (12.1 versus 15.2 N/mm, respectively). Load to failure was comparable between both groups (53.9 versus 50.9 N, respectively). A radially positioned locking plate for trapeziometacarpal arthrodesis may be biomechanically advantageous.</description><issn>1753-1934</issn><issn>2043-6289</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kEtLw0AUhQdRbK3-ADeSpZvUeU_GnYgvKAii63AzmbQpSSfOJIX6653Q6kZwdTnc7xzuPQhdEjwnRKkbogQjmnHKopRSyCM0pZizVNJMH6PpuE9HYILOQlhjLDJN5CmaMEWp5FJNUfEGZQ1NsrU-DCEpnQ9RdQ309WaZVM4nvYfOftWutT0Y8F1cg-9X3pU21OE2gcS4tgMfHVubFCNoVrCpTQRDP5S7c3RSQRPsxWHO0Mfjw_v9c7p4fXq5v1ukhmrap1orQZmVGGMKKqsqzW08k0gKRal0AUYwyxXThnOaFRZTJrQ2uqSCEyoFm6HrfW7n3edgQ5-3dTC2aWBj3RBymhFNleIxY4bIHjXeheBtlXe-bsHvcoLzsdr8T7XRc3WIH4rWlr-Ony4jMN8DAZY2X7vBb-K7_yR-A4-wgWM</recordid><startdate>20231001</startdate><enddate>20231001</enddate><creator>Cho, Jae-Yong</creator><creator>Lim, Joon-Ryul</creator><creator>Oh, Won-Taek</creator><creator>Koh, Il-Hyun</creator><creator>Chun, Yong-Min</creator><creator>Choi, Yun-Rak</creator><general>SAGE Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-6729-9292</orcidid><orcidid>https://orcid.org/0000-0001-5197-3716</orcidid></search><sort><creationdate>20231001</creationdate><title>Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study</title><author>Cho, Jae-Yong ; Lim, Joon-Ryul ; Oh, Won-Taek ; Koh, Il-Hyun ; Chun, Yong-Min ; Choi, Yun-Rak</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c292t-997523e60002a78ff94e722162abd79bac53e4739c4428be023599c9d25412653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cho, Jae-Yong</creatorcontrib><creatorcontrib>Lim, Joon-Ryul</creatorcontrib><creatorcontrib>Oh, Won-Taek</creatorcontrib><creatorcontrib>Koh, Il-Hyun</creatorcontrib><creatorcontrib>Chun, Yong-Min</creatorcontrib><creatorcontrib>Choi, Yun-Rak</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of hand surgery, European volume</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cho, Jae-Yong</au><au>Lim, Joon-Ryul</au><au>Oh, Won-Taek</au><au>Koh, Il-Hyun</au><au>Chun, Yong-Min</au><au>Choi, Yun-Rak</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study</atitle><jtitle>The Journal of hand surgery, European volume</jtitle><addtitle>J Hand Surg Eur Vol</addtitle><date>2023-10-01</date><risdate>2023</risdate><volume>48</volume><issue>9</issue><spage>872</spage><epage>876</epage><pages>872-876</pages><issn>1753-1934</issn><eissn>2043-6289</eissn><abstract>Trapeziometacarpal arthrodesis is used for the treatment of advanced arthritis. Insufficient stabilization of the joint may lead to nonunion or hardware problems after arthrodesis. The purpose of this study was to compare the biomechanical properties of dorsal versus radial plate fixation of the trapeziometacarpal joint in ten pairs of fresh-frozen cadaveric hands. The biomechanical performance of each group was measured for stiffness in extension and flexion and load to failure using cantilever bending tests. The stiffness in extension was lower in the dorsally positioned group than in the radially positioned group (12.1 versus 15.2 N/mm, respectively). Load to failure was comparable between both groups (53.9 versus 50.9 N, respectively). A radially positioned locking plate for trapeziometacarpal arthrodesis may be biomechanically advantageous.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>37226467</pmid><doi>10.1177/17531934231176656</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0002-6729-9292</orcidid><orcidid>https://orcid.org/0000-0001-5197-3716</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1753-1934 |
ispartof | The Journal of hand surgery, European volume, 2023-10, Vol.48 (9), p.872-876 |
issn | 1753-1934 2043-6289 |
language | eng |
recordid | cdi_proquest_miscellaneous_2819277447 |
source | Access via SAGE; Alma/SFX Local Collection |
title | Radial versus dorsal plating for trapeziometacarpal arthrodesis: a comparative biomechanical study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T13%3A05%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Radial%20versus%20dorsal%20plating%20for%20trapeziometacarpal%20arthrodesis:%20a%20comparative%20biomechanical%20study&rft.jtitle=The%20Journal%20of%20hand%20surgery,%20European%20volume&rft.au=Cho,%20Jae-Yong&rft.date=2023-10-01&rft.volume=48&rft.issue=9&rft.spage=872&rft.epage=876&rft.pages=872-876&rft.issn=1753-1934&rft.eissn=2043-6289&rft_id=info:doi/10.1177/17531934231176656&rft_dat=%3Cproquest_cross%3E2819277447%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2819277447&rft_id=info:pmid/37226467&rft_sage_id=10.1177_17531934231176656&rfr_iscdi=true |