Calibration of a neutron polarimeter to measure the electric form factor of the neutron
We measured the analyzing power and the efficiency of a new neutron polarimeter that was designed to measure G/sub E//sup n/, the neutron electric form factor. The polarimeter calibration was performed as experiment E377 at the Indiana University Cyclotron Facility (IUCF) with the /sup 14/C(p/spl I....
Gespeichert in:
Veröffentlicht in: | IEEE Transactions on Nuclear Science 1998-02, Vol.45 (1), p.68-74 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 74 |
---|---|
container_issue | 1 |
container_start_page | 68 |
container_title | IEEE Transactions on Nuclear Science |
container_volume | 45 |
creator | Niculescu, I. Suleiman, R. Madey, R. Eden, T. Anderson, B.D. Anderson, J.E. Baker, O.K. Baldwin, A.R. Brown, W.R. Cameron, J.M. Chang, C.C. Elaasar, M. Foster, C.C. Halli, C. Howell, C. Keane, D. Kelly, J.J. Lai, A. Liu, H. Manley, D.M. Markowitz, P. Niboh, M.M. Niculescu, G. Olson, M. Stephenson, E.J. Walter, R. Watson, J.W. Zhang, W.-M. |
description | We measured the analyzing power and the efficiency of a new neutron polarimeter that was designed to measure G/sub E//sup n/, the neutron electric form factor. The polarimeter calibration was performed as experiment E377 at the Indiana University Cyclotron Facility (IUCF) with the /sup 14/C(p/spl I.oarr/,n/spl I.oarr/)/sup 14/N reaction at proton beam energies of 124.0, 164.6, and 199.7 MeV without any shielding material ahead of the polarimeter; in addition, at 164.6 MeV we measured the analyzing power with 10 cm of lead, sandwiched between 3.5-cm iron plates, ahead of the polarimeter. |
doi_str_mv | 10.1109/23.659556 |
format | Article |
fullrecord | <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_miscellaneous_28191361</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>659556</ieee_id><sourcerecordid>28191361</sourcerecordid><originalsourceid>FETCH-LOGICAL-c303t-73289b5ca757586e22582eb8b502d14f0b825981e57f8c1984da3ad0f0c77a583</originalsourceid><addsrcrecordid>eNo9kL1LBDEUxIMoeJ4WtlaxESz2zMdmk5Ry-AUHNoplyOZeuMju5kyyhf-9e-xh9RjmN8NjELqmZEUp0Q-MrxqhhWhO0IIKoSoqpDpFC0KoqnSt9Tm6yPl7krUgYoG-1rYLbbIlxAFHjy0eYCxpEvvY2RR6KJBwibgHm8cEuOwAQweupOCwj6nH3roS0yF88I7xS3TmbZfh6niX6PP56WP9Wm3eX97Wj5vKccJLJTlTuhXOSiGFaoAxoRi0qhWEbWntSauY0IqCkF45qlW9tdxuiSdOSisUX6LbuTfmEkx2oYDbuTgM04emoZKTZmLuZmaf4s8IuZg-ZAddZweIYzZMUU15QyfwfgZdijkn8GY_LWDTr6HEHOY1jJt53om9mdkAAP_c0fwDHHB0Yg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28191361</pqid></control><display><type>article</type><title>Calibration of a neutron polarimeter to measure the electric form factor of the neutron</title><source>IEEE Electronic Library (IEL)</source><creator>Niculescu, I. ; Suleiman, R. ; Madey, R. ; Eden, T. ; Anderson, B.D. ; Anderson, J.E. ; Baker, O.K. ; Baldwin, A.R. ; Brown, W.R. ; Cameron, J.M. ; Chang, C.C. ; Elaasar, M. ; Foster, C.C. ; Halli, C. ; Howell, C. ; Keane, D. ; Kelly, J.J. ; Lai, A. ; Liu, H. ; Manley, D.M. ; Markowitz, P. ; Niboh, M.M. ; Niculescu, G. ; Olson, M. ; Stephenson, E.J. ; Walter, R. ; Watson, J.W. ; Zhang, W.-M.</creator><creatorcontrib>Niculescu, I. ; Suleiman, R. ; Madey, R. ; Eden, T. ; Anderson, B.D. ; Anderson, J.E. ; Baker, O.K. ; Baldwin, A.R. ; Brown, W.R. ; Cameron, J.M. ; Chang, C.C. ; Elaasar, M. ; Foster, C.C. ; Halli, C. ; Howell, C. ; Keane, D. ; Kelly, J.J. ; Lai, A. ; Liu, H. ; Manley, D.M. ; Markowitz, P. ; Niboh, M.M. ; Niculescu, G. ; Olson, M. ; Stephenson, E.J. ; Walter, R. ; Watson, J.W. ; Zhang, W.-M.</creatorcontrib><description>We measured the analyzing power and the efficiency of a new neutron polarimeter that was designed to measure G/sub E//sup n/, the neutron electric form factor. The polarimeter calibration was performed as experiment E377 at the Indiana University Cyclotron Facility (IUCF) with the /sup 14/C(p/spl I.oarr/,n/spl I.oarr/)/sup 14/N reaction at proton beam energies of 124.0, 164.6, and 199.7 MeV without any shielding material ahead of the polarimeter; in addition, at 164.6 MeV we measured the analyzing power <A/sub y/> with 10 cm of lead, sandwiched between 3.5-cm iron plates, ahead of the polarimeter.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/23.659556</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>United States: IEEE</publisher><subject>CALIBRATION ; CEBAF ACCELERATOR ; Cyclotrons ; Electric variables measurement ; ELECTROMAGNETIC FORM FACTORS ; Energy measurement ; INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS ; Iron ; MIT BATES LINAC ; NEUTRONS ; PARTICLE ACCELERATORS ; Particle beams ; Performance analysis ; Performance evaluation ; POLARIMETERS ; POLARIZATION-ASYMMETRY RATIO ; Power measurement</subject><ispartof>IEEE Transactions on Nuclear Science, 1998-02, Vol.45 (1), p.68-74</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c303t-73289b5ca757586e22582eb8b502d14f0b825981e57f8c1984da3ad0f0c77a583</citedby><cites>FETCH-LOGICAL-c303t-73289b5ca757586e22582eb8b502d14f0b825981e57f8c1984da3ad0f0c77a583</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/659556$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,777,781,793,882,27905,27906,54739</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/659556$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttps://www.osti.gov/biblio/617306$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Niculescu, I.</creatorcontrib><creatorcontrib>Suleiman, R.</creatorcontrib><creatorcontrib>Madey, R.</creatorcontrib><creatorcontrib>Eden, T.</creatorcontrib><creatorcontrib>Anderson, B.D.</creatorcontrib><creatorcontrib>Anderson, J.E.</creatorcontrib><creatorcontrib>Baker, O.K.</creatorcontrib><creatorcontrib>Baldwin, A.R.</creatorcontrib><creatorcontrib>Brown, W.R.</creatorcontrib><creatorcontrib>Cameron, J.M.</creatorcontrib><creatorcontrib>Chang, C.C.</creatorcontrib><creatorcontrib>Elaasar, M.</creatorcontrib><creatorcontrib>Foster, C.C.</creatorcontrib><creatorcontrib>Halli, C.</creatorcontrib><creatorcontrib>Howell, C.</creatorcontrib><creatorcontrib>Keane, D.</creatorcontrib><creatorcontrib>Kelly, J.J.</creatorcontrib><creatorcontrib>Lai, A.</creatorcontrib><creatorcontrib>Liu, H.</creatorcontrib><creatorcontrib>Manley, D.M.</creatorcontrib><creatorcontrib>Markowitz, P.</creatorcontrib><creatorcontrib>Niboh, M.M.</creatorcontrib><creatorcontrib>Niculescu, G.</creatorcontrib><creatorcontrib>Olson, M.</creatorcontrib><creatorcontrib>Stephenson, E.J.</creatorcontrib><creatorcontrib>Walter, R.</creatorcontrib><creatorcontrib>Watson, J.W.</creatorcontrib><creatorcontrib>Zhang, W.-M.</creatorcontrib><title>Calibration of a neutron polarimeter to measure the electric form factor of the neutron</title><title>IEEE Transactions on Nuclear Science</title><addtitle>TNS</addtitle><description>We measured the analyzing power and the efficiency of a new neutron polarimeter that was designed to measure G/sub E//sup n/, the neutron electric form factor. The polarimeter calibration was performed as experiment E377 at the Indiana University Cyclotron Facility (IUCF) with the /sup 14/C(p/spl I.oarr/,n/spl I.oarr/)/sup 14/N reaction at proton beam energies of 124.0, 164.6, and 199.7 MeV without any shielding material ahead of the polarimeter; in addition, at 164.6 MeV we measured the analyzing power <A/sub y/> with 10 cm of lead, sandwiched between 3.5-cm iron plates, ahead of the polarimeter.</description><subject>CALIBRATION</subject><subject>CEBAF ACCELERATOR</subject><subject>Cyclotrons</subject><subject>Electric variables measurement</subject><subject>ELECTROMAGNETIC FORM FACTORS</subject><subject>Energy measurement</subject><subject>INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS</subject><subject>Iron</subject><subject>MIT BATES LINAC</subject><subject>NEUTRONS</subject><subject>PARTICLE ACCELERATORS</subject><subject>Particle beams</subject><subject>Performance analysis</subject><subject>Performance evaluation</subject><subject>POLARIMETERS</subject><subject>POLARIZATION-ASYMMETRY RATIO</subject><subject>Power measurement</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kL1LBDEUxIMoeJ4WtlaxESz2zMdmk5Ry-AUHNoplyOZeuMju5kyyhf-9e-xh9RjmN8NjELqmZEUp0Q-MrxqhhWhO0IIKoSoqpDpFC0KoqnSt9Tm6yPl7krUgYoG-1rYLbbIlxAFHjy0eYCxpEvvY2RR6KJBwibgHm8cEuOwAQweupOCwj6nH3roS0yF88I7xS3TmbZfh6niX6PP56WP9Wm3eX97Wj5vKccJLJTlTuhXOSiGFaoAxoRi0qhWEbWntSauY0IqCkF45qlW9tdxuiSdOSisUX6LbuTfmEkx2oYDbuTgM04emoZKTZmLuZmaf4s8IuZg-ZAddZweIYzZMUU15QyfwfgZdijkn8GY_LWDTr6HEHOY1jJt53om9mdkAAP_c0fwDHHB0Yg</recordid><startdate>19980201</startdate><enddate>19980201</enddate><creator>Niculescu, I.</creator><creator>Suleiman, R.</creator><creator>Madey, R.</creator><creator>Eden, T.</creator><creator>Anderson, B.D.</creator><creator>Anderson, J.E.</creator><creator>Baker, O.K.</creator><creator>Baldwin, A.R.</creator><creator>Brown, W.R.</creator><creator>Cameron, J.M.</creator><creator>Chang, C.C.</creator><creator>Elaasar, M.</creator><creator>Foster, C.C.</creator><creator>Halli, C.</creator><creator>Howell, C.</creator><creator>Keane, D.</creator><creator>Kelly, J.J.</creator><creator>Lai, A.</creator><creator>Liu, H.</creator><creator>Manley, D.M.</creator><creator>Markowitz, P.</creator><creator>Niboh, M.M.</creator><creator>Niculescu, G.</creator><creator>Olson, M.</creator><creator>Stephenson, E.J.</creator><creator>Walter, R.</creator><creator>Watson, J.W.</creator><creator>Zhang, W.-M.</creator><general>IEEE</general><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>OTOTI</scope></search><sort><creationdate>19980201</creationdate><title>Calibration of a neutron polarimeter to measure the electric form factor of the neutron</title><author>Niculescu, I. ; Suleiman, R. ; Madey, R. ; Eden, T. ; Anderson, B.D. ; Anderson, J.E. ; Baker, O.K. ; Baldwin, A.R. ; Brown, W.R. ; Cameron, J.M. ; Chang, C.C. ; Elaasar, M. ; Foster, C.C. ; Halli, C. ; Howell, C. ; Keane, D. ; Kelly, J.J. ; Lai, A. ; Liu, H. ; Manley, D.M. ; Markowitz, P. ; Niboh, M.M. ; Niculescu, G. ; Olson, M. ; Stephenson, E.J. ; Walter, R. ; Watson, J.W. ; Zhang, W.-M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c303t-73289b5ca757586e22582eb8b502d14f0b825981e57f8c1984da3ad0f0c77a583</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>CALIBRATION</topic><topic>CEBAF ACCELERATOR</topic><topic>Cyclotrons</topic><topic>Electric variables measurement</topic><topic>ELECTROMAGNETIC FORM FACTORS</topic><topic>Energy measurement</topic><topic>INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS</topic><topic>Iron</topic><topic>MIT BATES LINAC</topic><topic>NEUTRONS</topic><topic>PARTICLE ACCELERATORS</topic><topic>Particle beams</topic><topic>Performance analysis</topic><topic>Performance evaluation</topic><topic>POLARIMETERS</topic><topic>POLARIZATION-ASYMMETRY RATIO</topic><topic>Power measurement</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Niculescu, I.</creatorcontrib><creatorcontrib>Suleiman, R.</creatorcontrib><creatorcontrib>Madey, R.</creatorcontrib><creatorcontrib>Eden, T.</creatorcontrib><creatorcontrib>Anderson, B.D.</creatorcontrib><creatorcontrib>Anderson, J.E.</creatorcontrib><creatorcontrib>Baker, O.K.</creatorcontrib><creatorcontrib>Baldwin, A.R.</creatorcontrib><creatorcontrib>Brown, W.R.</creatorcontrib><creatorcontrib>Cameron, J.M.</creatorcontrib><creatorcontrib>Chang, C.C.</creatorcontrib><creatorcontrib>Elaasar, M.</creatorcontrib><creatorcontrib>Foster, C.C.</creatorcontrib><creatorcontrib>Halli, C.</creatorcontrib><creatorcontrib>Howell, C.</creatorcontrib><creatorcontrib>Keane, D.</creatorcontrib><creatorcontrib>Kelly, J.J.</creatorcontrib><creatorcontrib>Lai, A.</creatorcontrib><creatorcontrib>Liu, H.</creatorcontrib><creatorcontrib>Manley, D.M.</creatorcontrib><creatorcontrib>Markowitz, P.</creatorcontrib><creatorcontrib>Niboh, M.M.</creatorcontrib><creatorcontrib>Niculescu, G.</creatorcontrib><creatorcontrib>Olson, M.</creatorcontrib><creatorcontrib>Stephenson, E.J.</creatorcontrib><creatorcontrib>Walter, R.</creatorcontrib><creatorcontrib>Watson, J.W.</creatorcontrib><creatorcontrib>Zhang, W.-M.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>OSTI.GOV</collection><jtitle>IEEE Transactions on Nuclear Science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Niculescu, I.</au><au>Suleiman, R.</au><au>Madey, R.</au><au>Eden, T.</au><au>Anderson, B.D.</au><au>Anderson, J.E.</au><au>Baker, O.K.</au><au>Baldwin, A.R.</au><au>Brown, W.R.</au><au>Cameron, J.M.</au><au>Chang, C.C.</au><au>Elaasar, M.</au><au>Foster, C.C.</au><au>Halli, C.</au><au>Howell, C.</au><au>Keane, D.</au><au>Kelly, J.J.</au><au>Lai, A.</au><au>Liu, H.</au><au>Manley, D.M.</au><au>Markowitz, P.</au><au>Niboh, M.M.</au><au>Niculescu, G.</au><au>Olson, M.</au><au>Stephenson, E.J.</au><au>Walter, R.</au><au>Watson, J.W.</au><au>Zhang, W.-M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calibration of a neutron polarimeter to measure the electric form factor of the neutron</atitle><jtitle>IEEE Transactions on Nuclear Science</jtitle><stitle>TNS</stitle><date>1998-02-01</date><risdate>1998</risdate><volume>45</volume><issue>1</issue><spage>68</spage><epage>74</epage><pages>68-74</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>We measured the analyzing power and the efficiency of a new neutron polarimeter that was designed to measure G/sub E//sup n/, the neutron electric form factor. The polarimeter calibration was performed as experiment E377 at the Indiana University Cyclotron Facility (IUCF) with the /sup 14/C(p/spl I.oarr/,n/spl I.oarr/)/sup 14/N reaction at proton beam energies of 124.0, 164.6, and 199.7 MeV without any shielding material ahead of the polarimeter; in addition, at 164.6 MeV we measured the analyzing power <A/sub y/> with 10 cm of lead, sandwiched between 3.5-cm iron plates, ahead of the polarimeter.</abstract><cop>United States</cop><pub>IEEE</pub><doi>10.1109/23.659556</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0018-9499 |
ispartof | IEEE Transactions on Nuclear Science, 1998-02, Vol.45 (1), p.68-74 |
issn | 0018-9499 1558-1578 |
language | eng |
recordid | cdi_proquest_miscellaneous_28191361 |
source | IEEE Electronic Library (IEL) |
subjects | CALIBRATION CEBAF ACCELERATOR Cyclotrons Electric variables measurement ELECTROMAGNETIC FORM FACTORS Energy measurement INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS Iron MIT BATES LINAC NEUTRONS PARTICLE ACCELERATORS Particle beams Performance analysis Performance evaluation POLARIMETERS POLARIZATION-ASYMMETRY RATIO Power measurement |
title | Calibration of a neutron polarimeter to measure the electric form factor of the neutron |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T11%3A20%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calibration%20of%20a%20neutron%20polarimeter%20to%20measure%20the%20electric%20form%20factor%20of%20the%20neutron&rft.jtitle=IEEE%20Transactions%20on%20Nuclear%20Science&rft.au=Niculescu,%20I.&rft.date=1998-02-01&rft.volume=45&rft.issue=1&rft.spage=68&rft.epage=74&rft.pages=68-74&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/23.659556&rft_dat=%3Cproquest_RIE%3E28191361%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=28191361&rft_id=info:pmid/&rft_ieee_id=659556&rfr_iscdi=true |