Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study

•The effect of the number and distribution methods of fiducial markers on robot-guided implant placement accuracy was evaluated.•Inserting six fiducial markers significantly increased the implant position accuracy.•No significant difference was observed between the dispersed and localized distributi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of dentistry 2023-07, Vol.134, p.104529-104529, Article 104529
Hauptverfasser: Zhao, Yaoyu, Liao, Yilin, Wu, Xinyu, Zhang, Yufeng, Shi, Bin, Yan, Qi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 104529
container_issue
container_start_page 104529
container_title Journal of dentistry
container_volume 134
creator Zhao, Yaoyu
Liao, Yilin
Wu, Xinyu
Zhang, Yufeng
Shi, Bin
Yan, Qi
description •The effect of the number and distribution methods of fiducial markers on robot-guided implant placement accuracy was evaluated.•Inserting six fiducial markers significantly increased the implant position accuracy.•No significant difference was observed between the dispersed and localized distribution methods. Robot-guided implant placement based on the screw marker-assisted registration technique has been applied in dentistry. This study aimed to identify the optimal number and distribution of fiducial markers for robot-guided implant placement in edentulous mandibular phantoms. Four implants were digitally planned and placed in edentulous mandibular phantoms under robotic guidance. Different numbers of fiducial markers (3, 4, 5, or 6) and distribution patterns (dispersed or localized) were used to register the robotic system. Platform, apex, and angular deviations were measured between the planned and actual implant positions using different numbers and distributions of fiducial markers. Inserting six fiducial markers resulted in optimal implant position accuracy at the platform (0.53 ± 0.19 mm) and apex (0.59 ± 0.2 mm) deviations. However, the angular deviation did not differ significantly between different numbers of fiducial markers. Furthermore, the implant position accuracy did not differ significantly between the dispersed and localized distributions of fiducial markers. In robot-guided implant placement for edentulous mandibular arches, the insertion of six fiducial markers significantly increases the implant placement accuracy. The findings of this in vitro study may serve as a reference for clinicians to determine the optimal placement of fiducial markers and to facilitate the clinical application of robot-guided systems for implant placement in edentulous patients. Further clinical studies are necessary to confirm these findings.
doi_str_mv 10.1016/j.jdent.2023.104529
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2807919398</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S030057122300115X</els_id><sourcerecordid>2807919398</sourcerecordid><originalsourceid>FETCH-LOGICAL-c359t-b6902282a9dccbb87771a8137f9c39f3d92f48536d602853d2b9e61ad5b23d953</originalsourceid><addsrcrecordid>eNp9UUtrFTEUDqLYa_UXCJKlm7nmcWcyEVyU0qpQcKPgLuRx0uY6M7nmUbj_pT_WTG916erAOd8r-RB6S8mWEjp82G_3DpayZYTxttn1TD5DGzoK2VEx_HyONoQT0vWCsjP0Kuc9IWRHmHyJzrigpN9xukEPV96DLTh6XO4AL3U2kLBeHHYhlxRMLSEu69kHV23QE551-gUp47ZeKdramrQ9rpgUTSzdbQ0OHA7zYdJLwbmmW0hHHBYMa-A6xZqbyuKa-qSbW7J3kD_ii2XF3IeSIs6luuNr9MLrKcObp3mOflxffb_80t18-_z18uKms7yXpTODJIyNTEtnrTGjEILqkXLhpeXScyeZ3409H9xAWJuOGQkD1a43rB17fo7en3QPKf6ukIuaQ7YwtfjQsio2EiGp5HJsUH6C2hRzTuDVIYX2I0dFiVprUXv1WItaa1GnWhrr3ZNBNTO4f5y_PTTApxMA2jPvAySVbYDFggup1aNcDP81-APjQaG4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2807919398</pqid></control><display><type>article</type><title>Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Zhao, Yaoyu ; Liao, Yilin ; Wu, Xinyu ; Zhang, Yufeng ; Shi, Bin ; Yan, Qi</creator><creatorcontrib>Zhao, Yaoyu ; Liao, Yilin ; Wu, Xinyu ; Zhang, Yufeng ; Shi, Bin ; Yan, Qi</creatorcontrib><description>•The effect of the number and distribution methods of fiducial markers on robot-guided implant placement accuracy was evaluated.•Inserting six fiducial markers significantly increased the implant position accuracy.•No significant difference was observed between the dispersed and localized distribution methods. Robot-guided implant placement based on the screw marker-assisted registration technique has been applied in dentistry. This study aimed to identify the optimal number and distribution of fiducial markers for robot-guided implant placement in edentulous mandibular phantoms. Four implants were digitally planned and placed in edentulous mandibular phantoms under robotic guidance. Different numbers of fiducial markers (3, 4, 5, or 6) and distribution patterns (dispersed or localized) were used to register the robotic system. Platform, apex, and angular deviations were measured between the planned and actual implant positions using different numbers and distributions of fiducial markers. Inserting six fiducial markers resulted in optimal implant position accuracy at the platform (0.53 ± 0.19 mm) and apex (0.59 ± 0.2 mm) deviations. However, the angular deviation did not differ significantly between different numbers of fiducial markers. Furthermore, the implant position accuracy did not differ significantly between the dispersed and localized distributions of fiducial markers. In robot-guided implant placement for edentulous mandibular arches, the insertion of six fiducial markers significantly increases the implant placement accuracy. The findings of this in vitro study may serve as a reference for clinicians to determine the optimal placement of fiducial markers and to facilitate the clinical application of robot-guided systems for implant placement in edentulous patients. Further clinical studies are necessary to confirm these findings.</description><identifier>ISSN: 0300-5712</identifier><identifier>EISSN: 1879-176X</identifier><identifier>DOI: 10.1016/j.jdent.2023.104529</identifier><identifier>PMID: 37105431</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Computer assisted implant surgery ; Computer-Aided Design ; Cone-Beam Computed Tomography - methods ; Dental implant ; Dental Implantation, Endosseous - methods ; Dental Implants ; Edentulous jaw ; Fiducial marker ; Fiducial Markers ; Humans ; Imaging, Three-Dimensional ; In vitro study ; Mouth, Edentulous - diagnostic imaging ; Mouth, Edentulous - surgery ; Robot-guided surgery ; Robotic Surgical Procedures ; Robotics ; Surgery, Computer-Assisted - methods</subject><ispartof>Journal of dentistry, 2023-07, Vol.134, p.104529-104529, Article 104529</ispartof><rights>2023</rights><rights>Copyright © 2023. Published by Elsevier Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c359t-b6902282a9dccbb87771a8137f9c39f3d92f48536d602853d2b9e61ad5b23d953</citedby><cites>FETCH-LOGICAL-c359t-b6902282a9dccbb87771a8137f9c39f3d92f48536d602853d2b9e61ad5b23d953</cites><orcidid>0000-0002-2625-2420</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jdent.2023.104529$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>315,781,785,3551,27929,27930,46000</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37105431$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhao, Yaoyu</creatorcontrib><creatorcontrib>Liao, Yilin</creatorcontrib><creatorcontrib>Wu, Xinyu</creatorcontrib><creatorcontrib>Zhang, Yufeng</creatorcontrib><creatorcontrib>Shi, Bin</creatorcontrib><creatorcontrib>Yan, Qi</creatorcontrib><title>Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study</title><title>Journal of dentistry</title><addtitle>J Dent</addtitle><description>•The effect of the number and distribution methods of fiducial markers on robot-guided implant placement accuracy was evaluated.•Inserting six fiducial markers significantly increased the implant position accuracy.•No significant difference was observed between the dispersed and localized distribution methods. Robot-guided implant placement based on the screw marker-assisted registration technique has been applied in dentistry. This study aimed to identify the optimal number and distribution of fiducial markers for robot-guided implant placement in edentulous mandibular phantoms. Four implants were digitally planned and placed in edentulous mandibular phantoms under robotic guidance. Different numbers of fiducial markers (3, 4, 5, or 6) and distribution patterns (dispersed or localized) were used to register the robotic system. Platform, apex, and angular deviations were measured between the planned and actual implant positions using different numbers and distributions of fiducial markers. Inserting six fiducial markers resulted in optimal implant position accuracy at the platform (0.53 ± 0.19 mm) and apex (0.59 ± 0.2 mm) deviations. However, the angular deviation did not differ significantly between different numbers of fiducial markers. Furthermore, the implant position accuracy did not differ significantly between the dispersed and localized distributions of fiducial markers. In robot-guided implant placement for edentulous mandibular arches, the insertion of six fiducial markers significantly increases the implant placement accuracy. The findings of this in vitro study may serve as a reference for clinicians to determine the optimal placement of fiducial markers and to facilitate the clinical application of robot-guided systems for implant placement in edentulous patients. Further clinical studies are necessary to confirm these findings.</description><subject>Computer assisted implant surgery</subject><subject>Computer-Aided Design</subject><subject>Cone-Beam Computed Tomography - methods</subject><subject>Dental implant</subject><subject>Dental Implantation, Endosseous - methods</subject><subject>Dental Implants</subject><subject>Edentulous jaw</subject><subject>Fiducial marker</subject><subject>Fiducial Markers</subject><subject>Humans</subject><subject>Imaging, Three-Dimensional</subject><subject>In vitro study</subject><subject>Mouth, Edentulous - diagnostic imaging</subject><subject>Mouth, Edentulous - surgery</subject><subject>Robot-guided surgery</subject><subject>Robotic Surgical Procedures</subject><subject>Robotics</subject><subject>Surgery, Computer-Assisted - methods</subject><issn>0300-5712</issn><issn>1879-176X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9UUtrFTEUDqLYa_UXCJKlm7nmcWcyEVyU0qpQcKPgLuRx0uY6M7nmUbj_pT_WTG916erAOd8r-RB6S8mWEjp82G_3DpayZYTxttn1TD5DGzoK2VEx_HyONoQT0vWCsjP0Kuc9IWRHmHyJzrigpN9xukEPV96DLTh6XO4AL3U2kLBeHHYhlxRMLSEu69kHV23QE551-gUp47ZeKdramrQ9rpgUTSzdbQ0OHA7zYdJLwbmmW0hHHBYMa-A6xZqbyuKa-qSbW7J3kD_ii2XF3IeSIs6luuNr9MLrKcObp3mOflxffb_80t18-_z18uKms7yXpTODJIyNTEtnrTGjEILqkXLhpeXScyeZ3409H9xAWJuOGQkD1a43rB17fo7en3QPKf6ukIuaQ7YwtfjQsio2EiGp5HJsUH6C2hRzTuDVIYX2I0dFiVprUXv1WItaa1GnWhrr3ZNBNTO4f5y_PTTApxMA2jPvAySVbYDFggup1aNcDP81-APjQaG4</recordid><startdate>202307</startdate><enddate>202307</enddate><creator>Zhao, Yaoyu</creator><creator>Liao, Yilin</creator><creator>Wu, Xinyu</creator><creator>Zhang, Yufeng</creator><creator>Shi, Bin</creator><creator>Yan, Qi</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-2625-2420</orcidid></search><sort><creationdate>202307</creationdate><title>Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study</title><author>Zhao, Yaoyu ; Liao, Yilin ; Wu, Xinyu ; Zhang, Yufeng ; Shi, Bin ; Yan, Qi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c359t-b6902282a9dccbb87771a8137f9c39f3d92f48536d602853d2b9e61ad5b23d953</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Computer assisted implant surgery</topic><topic>Computer-Aided Design</topic><topic>Cone-Beam Computed Tomography - methods</topic><topic>Dental implant</topic><topic>Dental Implantation, Endosseous - methods</topic><topic>Dental Implants</topic><topic>Edentulous jaw</topic><topic>Fiducial marker</topic><topic>Fiducial Markers</topic><topic>Humans</topic><topic>Imaging, Three-Dimensional</topic><topic>In vitro study</topic><topic>Mouth, Edentulous - diagnostic imaging</topic><topic>Mouth, Edentulous - surgery</topic><topic>Robot-guided surgery</topic><topic>Robotic Surgical Procedures</topic><topic>Robotics</topic><topic>Surgery, Computer-Assisted - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhao, Yaoyu</creatorcontrib><creatorcontrib>Liao, Yilin</creatorcontrib><creatorcontrib>Wu, Xinyu</creatorcontrib><creatorcontrib>Zhang, Yufeng</creatorcontrib><creatorcontrib>Shi, Bin</creatorcontrib><creatorcontrib>Yan, Qi</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhao, Yaoyu</au><au>Liao, Yilin</au><au>Wu, Xinyu</au><au>Zhang, Yufeng</au><au>Shi, Bin</au><au>Yan, Qi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study</atitle><jtitle>Journal of dentistry</jtitle><addtitle>J Dent</addtitle><date>2023-07</date><risdate>2023</risdate><volume>134</volume><spage>104529</spage><epage>104529</epage><pages>104529-104529</pages><artnum>104529</artnum><issn>0300-5712</issn><eissn>1879-176X</eissn><abstract>•The effect of the number and distribution methods of fiducial markers on robot-guided implant placement accuracy was evaluated.•Inserting six fiducial markers significantly increased the implant position accuracy.•No significant difference was observed between the dispersed and localized distribution methods. Robot-guided implant placement based on the screw marker-assisted registration technique has been applied in dentistry. This study aimed to identify the optimal number and distribution of fiducial markers for robot-guided implant placement in edentulous mandibular phantoms. Four implants were digitally planned and placed in edentulous mandibular phantoms under robotic guidance. Different numbers of fiducial markers (3, 4, 5, or 6) and distribution patterns (dispersed or localized) were used to register the robotic system. Platform, apex, and angular deviations were measured between the planned and actual implant positions using different numbers and distributions of fiducial markers. Inserting six fiducial markers resulted in optimal implant position accuracy at the platform (0.53 ± 0.19 mm) and apex (0.59 ± 0.2 mm) deviations. However, the angular deviation did not differ significantly between different numbers of fiducial markers. Furthermore, the implant position accuracy did not differ significantly between the dispersed and localized distributions of fiducial markers. In robot-guided implant placement for edentulous mandibular arches, the insertion of six fiducial markers significantly increases the implant placement accuracy. The findings of this in vitro study may serve as a reference for clinicians to determine the optimal placement of fiducial markers and to facilitate the clinical application of robot-guided systems for implant placement in edentulous patients. Further clinical studies are necessary to confirm these findings.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>37105431</pmid><doi>10.1016/j.jdent.2023.104529</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0002-2625-2420</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0300-5712
ispartof Journal of dentistry, 2023-07, Vol.134, p.104529-104529, Article 104529
issn 0300-5712
1879-176X
language eng
recordid cdi_proquest_miscellaneous_2807919398
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Computer assisted implant surgery
Computer-Aided Design
Cone-Beam Computed Tomography - methods
Dental implant
Dental Implantation, Endosseous - methods
Dental Implants
Edentulous jaw
Fiducial marker
Fiducial Markers
Humans
Imaging, Three-Dimensional
In vitro study
Mouth, Edentulous - diagnostic imaging
Mouth, Edentulous - surgery
Robot-guided surgery
Robotic Surgical Procedures
Robotics
Surgery, Computer-Assisted - methods
title Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T16%3A57%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20the%20number%20and%20distribution%20of%20fiducial%20markers%20on%20the%20accuracy%20of%20robot-guided%20implant%20surgery%20in%20edentulous%20mandibular%20arches:%20An%20in%20vitro%20study&rft.jtitle=Journal%20of%20dentistry&rft.au=Zhao,%20Yaoyu&rft.date=2023-07&rft.volume=134&rft.spage=104529&rft.epage=104529&rft.pages=104529-104529&rft.artnum=104529&rft.issn=0300-5712&rft.eissn=1879-176X&rft_id=info:doi/10.1016/j.jdent.2023.104529&rft_dat=%3Cproquest_cross%3E2807919398%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2807919398&rft_id=info:pmid/37105431&rft_els_id=S030057122300115X&rfr_iscdi=true