Efficient and Unique System for Verifying Containment of Hazardous Substances
The European Union's directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) prohibits the use of certain hazardous substances. One of the targets of our environment protection program is to eliminate these substances from all Fujits...
Gespeichert in:
Veröffentlicht in: | Fujitsu scientific & technical journal 2005-01, Vol.41 (2), p.209-216 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 216 |
---|---|
container_issue | 2 |
container_start_page | 209 |
container_title | Fujitsu scientific & technical journal |
container_volume | 41 |
creator | Ozaki, Mitsuo Yamagishi, Yasuo |
description | The European Union's directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) prohibits the use of certain hazardous substances. One of the targets of our environment protection program is to eliminate these substances from all Fujitsu brand products by the end of March 2006. To achieve this target, we are promoting green procurement and non-containment verification of these substances. We have developed a unique system to efficiently verify that several hundred thousand types of parts composed of various materials do not contain the RoHS-prohibited substances. This system has two elements. One is a substance containment probability chart that is based on an investigation of situations in which those substances are used. The other is a high-accuracy quantitative technique that uses simple X-ray fluorescent (XRF) spectrometry. This system enables us to efficiently verify non-containment by screening parts that have a high substance-containment probability and then accurately measuring substance concentrations using XRF spectrometry. |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_28011972</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>28011972</sourcerecordid><originalsourceid>FETCH-LOGICAL-p186t-bccb9365afe7d2cf4c7fbd49bae60515ad42f7a500295001c5c9f37905eb36b83</originalsourceid><addsrcrecordid>eNotzr1OwzAUBWAPIFEK7-CJLZJ_YiceUVQoUlGHUtbq2r5GRolTYmcoT08QLOcsR0ffFVkxxnUllJA35DbnT8aEVrxekddNCNFFTIVC8vSY4teM9HDJBQcaxom-4xTDJaYP2o2pQEzD73YMdAvfMPlxzvQw21wgOcx35DpAn_H-v9fk-LR567bVbv_80j3uqjNvdamsc9ZIrSBg44ULtWuC9bWxgJoprsDXIjSgFqVZgjvlTJCNYQqt1LaVa_Lw93uexsWby2mI2WHfQ8JFdBIt49w0Qv4AqzhLdg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28011972</pqid></control><display><type>article</type><title>Efficient and Unique System for Verifying Containment of Hazardous Substances</title><source>Freely Accessible Japanese Titles</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Ozaki, Mitsuo ; Yamagishi, Yasuo</creator><creatorcontrib>Ozaki, Mitsuo ; Yamagishi, Yasuo</creatorcontrib><description>The European Union's directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) prohibits the use of certain hazardous substances. One of the targets of our environment protection program is to eliminate these substances from all Fujitsu brand products by the end of March 2006. To achieve this target, we are promoting green procurement and non-containment verification of these substances. We have developed a unique system to efficiently verify that several hundred thousand types of parts composed of various materials do not contain the RoHS-prohibited substances. This system has two elements. One is a substance containment probability chart that is based on an investigation of situations in which those substances are used. The other is a high-accuracy quantitative technique that uses simple X-ray fluorescent (XRF) spectrometry. This system enables us to efficiently verify non-containment by screening parts that have a high substance-containment probability and then accurately measuring substance concentrations using XRF spectrometry.</description><identifier>ISSN: 0016-2523</identifier><language>eng</language><ispartof>Fujitsu scientific & technical journal, 2005-01, Vol.41 (2), p.209-216</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785</link.rule.ids></links><search><creatorcontrib>Ozaki, Mitsuo</creatorcontrib><creatorcontrib>Yamagishi, Yasuo</creatorcontrib><title>Efficient and Unique System for Verifying Containment of Hazardous Substances</title><title>Fujitsu scientific & technical journal</title><description>The European Union's directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) prohibits the use of certain hazardous substances. One of the targets of our environment protection program is to eliminate these substances from all Fujitsu brand products by the end of March 2006. To achieve this target, we are promoting green procurement and non-containment verification of these substances. We have developed a unique system to efficiently verify that several hundred thousand types of parts composed of various materials do not contain the RoHS-prohibited substances. This system has two elements. One is a substance containment probability chart that is based on an investigation of situations in which those substances are used. The other is a high-accuracy quantitative technique that uses simple X-ray fluorescent (XRF) spectrometry. This system enables us to efficiently verify non-containment by screening parts that have a high substance-containment probability and then accurately measuring substance concentrations using XRF spectrometry.</description><issn>0016-2523</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNotzr1OwzAUBWAPIFEK7-CJLZJ_YiceUVQoUlGHUtbq2r5GRolTYmcoT08QLOcsR0ffFVkxxnUllJA35DbnT8aEVrxekddNCNFFTIVC8vSY4teM9HDJBQcaxom-4xTDJaYP2o2pQEzD73YMdAvfMPlxzvQw21wgOcx35DpAn_H-v9fk-LR567bVbv_80j3uqjNvdamsc9ZIrSBg44ULtWuC9bWxgJoprsDXIjSgFqVZgjvlTJCNYQqt1LaVa_Lw93uexsWby2mI2WHfQ8JFdBIt49w0Qv4AqzhLdg</recordid><startdate>20050101</startdate><enddate>20050101</enddate><creator>Ozaki, Mitsuo</creator><creator>Yamagishi, Yasuo</creator><scope>7SP</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>20050101</creationdate><title>Efficient and Unique System for Verifying Containment of Hazardous Substances</title><author>Ozaki, Mitsuo ; Yamagishi, Yasuo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p186t-bccb9365afe7d2cf4c7fbd49bae60515ad42f7a500295001c5c9f37905eb36b83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ozaki, Mitsuo</creatorcontrib><creatorcontrib>Yamagishi, Yasuo</creatorcontrib><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Fujitsu scientific & technical journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ozaki, Mitsuo</au><au>Yamagishi, Yasuo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Efficient and Unique System for Verifying Containment of Hazardous Substances</atitle><jtitle>Fujitsu scientific & technical journal</jtitle><date>2005-01-01</date><risdate>2005</risdate><volume>41</volume><issue>2</issue><spage>209</spage><epage>216</epage><pages>209-216</pages><issn>0016-2523</issn><abstract>The European Union's directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) prohibits the use of certain hazardous substances. One of the targets of our environment protection program is to eliminate these substances from all Fujitsu brand products by the end of March 2006. To achieve this target, we are promoting green procurement and non-containment verification of these substances. We have developed a unique system to efficiently verify that several hundred thousand types of parts composed of various materials do not contain the RoHS-prohibited substances. This system has two elements. One is a substance containment probability chart that is based on an investigation of situations in which those substances are used. The other is a high-accuracy quantitative technique that uses simple X-ray fluorescent (XRF) spectrometry. This system enables us to efficiently verify non-containment by screening parts that have a high substance-containment probability and then accurately measuring substance concentrations using XRF spectrometry.</abstract><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0016-2523 |
ispartof | Fujitsu scientific & technical journal, 2005-01, Vol.41 (2), p.209-216 |
issn | 0016-2523 |
language | eng |
recordid | cdi_proquest_miscellaneous_28011972 |
source | Freely Accessible Japanese Titles; EZB-FREE-00999 freely available EZB journals |
title | Efficient and Unique System for Verifying Containment of Hazardous Substances |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-14T23%3A55%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Efficient%20and%20Unique%20System%20for%20Verifying%20Containment%20of%20Hazardous%20Substances&rft.jtitle=Fujitsu%20scientific%20&%20technical%20journal&rft.au=Ozaki,%20Mitsuo&rft.date=2005-01-01&rft.volume=41&rft.issue=2&rft.spage=209&rft.epage=216&rft.pages=209-216&rft.issn=0016-2523&rft_id=info:doi/&rft_dat=%3Cproquest%3E28011972%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=28011972&rft_id=info:pmid/&rfr_iscdi=true |