Using Gurney Flaps to Control Laminar Separation on Linear Cascade Blades

This paper describes an experimental investigation of the use of Gurney flaps to control laminar separation on turbine blades in a linear cascade. Measurements were made at Reynolds numbers (based upon inlet velocity and axial chord) of 28×103,65×103 and 167×103. The freestream turbulence intensity...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of turbomachinery 2003-01, Vol.125 (1), p.114-120
Hauptverfasser: Byerley, Aaron R, Sto¨rmer, Oliver, Baughn, James W, Simon, Terrence W, Van Treuren, Kenneth W, List, Jo¨rg
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper describes an experimental investigation of the use of Gurney flaps to control laminar separation on turbine blades in a linear cascade. Measurements were made at Reynolds numbers (based upon inlet velocity and axial chord) of 28×103,65×103 and 167×103. The freestream turbulence intensity for all three cases was 0.8%. Laminar separation was present on the suction surface of the Langston blade shape for the two lower Reynolds numbers. In an effort to control the laminar separation, Gurney flaps were added to the pressure surface close to the trailing edge. The measurements indicate that the flaps turn and accelerate the flow in the blade passage toward the suction surface of the neighboring blade thereby eliminating the separation bubble. Five different sizes of Gurney flaps, ranging from 0.6 to 2.7% of axial chord, were tested. The laser thermal tuft technique was used to determine the influence of the Gurney flaps on the location and size of the separation bubble. Additionally, measurements of wall static pressure, profile loss, and blade-exit flow angle were made. The blade pressure distribution indicates that the lift generated by the blade is increased. As was expected, the Gurney flap also produced a larger wake. In practice, Gurney flaps might possibly be implemented in a semi-passive manner. They could be deployed for low Reynolds number operation and then retracted at high Reynolds numbers when separation is not present. This work is important because it describes a successful means for eliminating the separation bubble while characterizing both the potential performance improvement and the penalties associated with this semi-passive flow control technique.
ISSN:0889-504X
1528-8900
DOI:10.1115/1.1518701