Development and characterization of modular mouse phantoms for end-to-end testing and training in radiobiology experiments

. In radiation oncology, experiments are often carried out using mice as a model for research studies. Due to recent technological advances in the development of high-precision small-animal irradiation facilities, the importance of quality assurance for both dosimetry and imaging is increasing. Addi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physics in medicine & biology 2023-04, Vol.68 (8), p.85009
Hauptverfasser: Wegner, Marie, Frenzel, Thorsten, Krause, Dieter, Gargioni, Elisabetta
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 8
container_start_page 85009
container_title Physics in medicine & biology
container_volume 68
creator Wegner, Marie
Frenzel, Thorsten
Krause, Dieter
Gargioni, Elisabetta
description . In radiation oncology, experiments are often carried out using mice as a model for research studies. Due to recent technological advances in the development of high-precision small-animal irradiation facilities, the importance of quality assurance for both dosimetry and imaging is increasing. Additive manufacturing (AM) offers the possibility to produce complex models from a three-dimensional data set and to build cost-effective phantoms that can easily be adapted to different purposes. The aim of this work was therefore to develop detailed anatomical mouse models for quality assurance and end-to-end testing of small-animal irradiation and imaging by means of AM. . Two mouse phantom concepts were designed, constructed, and examined for this purpose. The first model includes cavities corresponding to the most important organs. The final solid model was constructed using AM in two separate parts that can be attached with a plug connection after filling these cavities with tissue-equivalent mixtures. Moreover, different radiation dosimeters can be placed in the lower part of the model. For the second concept, AM was used for building modules like the phantom outer shell and bones, so that different mixtures can be used as a filling, without modifying the phantom structure. CT as well as Micro-CT scans of both concepts showed an excellent quality and adequate image contrast, with material attenuation properties close to those of mouse tissues, apart from the current bone surrogates. Radiation dose measurements with radiochromic films were, with some exceptions in areas with larges bone volumes, in agreement with calculations within less than ±4%. . AM shows great potential for the development of mouse models that are inexpensive, easy to adapt, and accurate, thus enabling their use for quality assurance in small-animal radiotherapy and imaging. The introduction of such 3D-printable mouse phantoms in the workflow could also significantly reduce the use of living animals for optimization and testing of new imaging and irradiation protocols.
doi_str_mv 10.1088/1361-6560/acc566
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_2796158066</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2796158066</sourcerecordid><originalsourceid>FETCH-LOGICAL-c410t-640e823bf11f14688eab1d35424c4dd22a6b6a042fa73a841e7fc286ff5b2a853</originalsourceid><addsrcrecordid>eNp1kDtvFTEQhS1ERC6Bngq5g4JNbK_t6y1ReEWKlAZqa9aPxNGuvdjeiOTX4-WGVFAdzeibMzMHoTeUnFKi1BntJe2kkOQMjBFSPkO7p9ZztCOkp91AhThGL0u5JYRSxfgLdNzLoSeD4jv08MnduSkts4sVQ7TY3EAGU10OD1BDijh5PCe7TpCbrsXh5QZiTXPBPmXsou1q6prg6koN8fqPS80Q4laEiDPYkMaQpnR9j92vpVlv28ordORhKu71o56gH18-fz__1l1efb04_3jZGU5J7SQnTrF-9JR6yqVSDkZqe8EZN9xaxkCOEghnHvY9KE7d3humpPdiZKBEf4LeH3yXnH6u7Ug9h2LcNEF07SHN9oOkQhEpG0oOqMmplOy8XtqxkO81JXpLXG_x6i1efUi8jbx9dF_H2dmngb8RN-DdAQhp0bdpzbE9q5d51FJppYkShAx6sb6RH_5B_nfzb8nLmdk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2796158066</pqid></control><display><type>article</type><title>Development and characterization of modular mouse phantoms for end-to-end testing and training in radiobiology experiments</title><source>MEDLINE</source><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Wegner, Marie ; Frenzel, Thorsten ; Krause, Dieter ; Gargioni, Elisabetta</creator><creatorcontrib>Wegner, Marie ; Frenzel, Thorsten ; Krause, Dieter ; Gargioni, Elisabetta</creatorcontrib><description>. In radiation oncology, experiments are often carried out using mice as a model for research studies. Due to recent technological advances in the development of high-precision small-animal irradiation facilities, the importance of quality assurance for both dosimetry and imaging is increasing. Additive manufacturing (AM) offers the possibility to produce complex models from a three-dimensional data set and to build cost-effective phantoms that can easily be adapted to different purposes. The aim of this work was therefore to develop detailed anatomical mouse models for quality assurance and end-to-end testing of small-animal irradiation and imaging by means of AM. . Two mouse phantom concepts were designed, constructed, and examined for this purpose. The first model includes cavities corresponding to the most important organs. The final solid model was constructed using AM in two separate parts that can be attached with a plug connection after filling these cavities with tissue-equivalent mixtures. Moreover, different radiation dosimeters can be placed in the lower part of the model. For the second concept, AM was used for building modules like the phantom outer shell and bones, so that different mixtures can be used as a filling, without modifying the phantom structure. CT as well as Micro-CT scans of both concepts showed an excellent quality and adequate image contrast, with material attenuation properties close to those of mouse tissues, apart from the current bone surrogates. Radiation dose measurements with radiochromic films were, with some exceptions in areas with larges bone volumes, in agreement with calculations within less than ±4%. . AM shows great potential for the development of mouse models that are inexpensive, easy to adapt, and accurate, thus enabling their use for quality assurance in small-animal radiotherapy and imaging. The introduction of such 3D-printable mouse phantoms in the workflow could also significantly reduce the use of living animals for optimization and testing of new imaging and irradiation protocols.</description><identifier>ISSN: 0031-9155</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/1361-6560/acc566</identifier><identifier>PMID: 36930984</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>additive manufacturing ; Animals ; dosimetry ; Mice ; Monte Carlo simulation ; mouse phantom ; Phantoms, Imaging ; Radiobiology ; Radiometry - methods ; Radiotherapy Dosage ; small-animal irradiation ; X-Ray Microtomography</subject><ispartof>Physics in medicine &amp; biology, 2023-04, Vol.68 (8), p.85009</ispartof><rights>2023 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd</rights><rights>Creative Commons Attribution license.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c410t-640e823bf11f14688eab1d35424c4dd22a6b6a042fa73a841e7fc286ff5b2a853</citedby><cites>FETCH-LOGICAL-c410t-640e823bf11f14688eab1d35424c4dd22a6b6a042fa73a841e7fc286ff5b2a853</cites><orcidid>0000-0001-8616-859X ; 0000-0002-1253-1699 ; 0000-0002-8204-0609</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1361-6560/acc566/pdf$$EPDF$$P50$$Giop$$Hfree_for_read</linktopdf><link.rule.ids>314,780,784,27924,27925,53846,53893</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36930984$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wegner, Marie</creatorcontrib><creatorcontrib>Frenzel, Thorsten</creatorcontrib><creatorcontrib>Krause, Dieter</creatorcontrib><creatorcontrib>Gargioni, Elisabetta</creatorcontrib><title>Development and characterization of modular mouse phantoms for end-to-end testing and training in radiobiology experiments</title><title>Physics in medicine &amp; biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>. In radiation oncology, experiments are often carried out using mice as a model for research studies. Due to recent technological advances in the development of high-precision small-animal irradiation facilities, the importance of quality assurance for both dosimetry and imaging is increasing. Additive manufacturing (AM) offers the possibility to produce complex models from a three-dimensional data set and to build cost-effective phantoms that can easily be adapted to different purposes. The aim of this work was therefore to develop detailed anatomical mouse models for quality assurance and end-to-end testing of small-animal irradiation and imaging by means of AM. . Two mouse phantom concepts were designed, constructed, and examined for this purpose. The first model includes cavities corresponding to the most important organs. The final solid model was constructed using AM in two separate parts that can be attached with a plug connection after filling these cavities with tissue-equivalent mixtures. Moreover, different radiation dosimeters can be placed in the lower part of the model. For the second concept, AM was used for building modules like the phantom outer shell and bones, so that different mixtures can be used as a filling, without modifying the phantom structure. CT as well as Micro-CT scans of both concepts showed an excellent quality and adequate image contrast, with material attenuation properties close to those of mouse tissues, apart from the current bone surrogates. Radiation dose measurements with radiochromic films were, with some exceptions in areas with larges bone volumes, in agreement with calculations within less than ±4%. . AM shows great potential for the development of mouse models that are inexpensive, easy to adapt, and accurate, thus enabling their use for quality assurance in small-animal radiotherapy and imaging. The introduction of such 3D-printable mouse phantoms in the workflow could also significantly reduce the use of living animals for optimization and testing of new imaging and irradiation protocols.</description><subject>additive manufacturing</subject><subject>Animals</subject><subject>dosimetry</subject><subject>Mice</subject><subject>Monte Carlo simulation</subject><subject>mouse phantom</subject><subject>Phantoms, Imaging</subject><subject>Radiobiology</subject><subject>Radiometry - methods</subject><subject>Radiotherapy Dosage</subject><subject>small-animal irradiation</subject><subject>X-Ray Microtomography</subject><issn>0031-9155</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>O3W</sourceid><sourceid>EIF</sourceid><recordid>eNp1kDtvFTEQhS1ERC6Bngq5g4JNbK_t6y1ReEWKlAZqa9aPxNGuvdjeiOTX4-WGVFAdzeibMzMHoTeUnFKi1BntJe2kkOQMjBFSPkO7p9ZztCOkp91AhThGL0u5JYRSxfgLdNzLoSeD4jv08MnduSkts4sVQ7TY3EAGU10OD1BDijh5PCe7TpCbrsXh5QZiTXPBPmXsou1q6prg6koN8fqPS80Q4laEiDPYkMaQpnR9j92vpVlv28ordORhKu71o56gH18-fz__1l1efb04_3jZGU5J7SQnTrF-9JR6yqVSDkZqe8EZN9xaxkCOEghnHvY9KE7d3humpPdiZKBEf4LeH3yXnH6u7Ug9h2LcNEF07SHN9oOkQhEpG0oOqMmplOy8XtqxkO81JXpLXG_x6i1efUi8jbx9dF_H2dmngb8RN-DdAQhp0bdpzbE9q5d51FJppYkShAx6sb6RH_5B_nfzb8nLmdk</recordid><startdate>20230421</startdate><enddate>20230421</enddate><creator>Wegner, Marie</creator><creator>Frenzel, Thorsten</creator><creator>Krause, Dieter</creator><creator>Gargioni, Elisabetta</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-8616-859X</orcidid><orcidid>https://orcid.org/0000-0002-1253-1699</orcidid><orcidid>https://orcid.org/0000-0002-8204-0609</orcidid></search><sort><creationdate>20230421</creationdate><title>Development and characterization of modular mouse phantoms for end-to-end testing and training in radiobiology experiments</title><author>Wegner, Marie ; Frenzel, Thorsten ; Krause, Dieter ; Gargioni, Elisabetta</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c410t-640e823bf11f14688eab1d35424c4dd22a6b6a042fa73a841e7fc286ff5b2a853</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>additive manufacturing</topic><topic>Animals</topic><topic>dosimetry</topic><topic>Mice</topic><topic>Monte Carlo simulation</topic><topic>mouse phantom</topic><topic>Phantoms, Imaging</topic><topic>Radiobiology</topic><topic>Radiometry - methods</topic><topic>Radiotherapy Dosage</topic><topic>small-animal irradiation</topic><topic>X-Ray Microtomography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wegner, Marie</creatorcontrib><creatorcontrib>Frenzel, Thorsten</creatorcontrib><creatorcontrib>Krause, Dieter</creatorcontrib><creatorcontrib>Gargioni, Elisabetta</creatorcontrib><collection>Institute of Physics Open Access Journal Titles</collection><collection>IOPscience (Open Access)</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wegner, Marie</au><au>Frenzel, Thorsten</au><au>Krause, Dieter</au><au>Gargioni, Elisabetta</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development and characterization of modular mouse phantoms for end-to-end testing and training in radiobiology experiments</atitle><jtitle>Physics in medicine &amp; biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2023-04-21</date><risdate>2023</risdate><volume>68</volume><issue>8</issue><spage>85009</spage><pages>85009-</pages><issn>0031-9155</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>. In radiation oncology, experiments are often carried out using mice as a model for research studies. Due to recent technological advances in the development of high-precision small-animal irradiation facilities, the importance of quality assurance for both dosimetry and imaging is increasing. Additive manufacturing (AM) offers the possibility to produce complex models from a three-dimensional data set and to build cost-effective phantoms that can easily be adapted to different purposes. The aim of this work was therefore to develop detailed anatomical mouse models for quality assurance and end-to-end testing of small-animal irradiation and imaging by means of AM. . Two mouse phantom concepts were designed, constructed, and examined for this purpose. The first model includes cavities corresponding to the most important organs. The final solid model was constructed using AM in two separate parts that can be attached with a plug connection after filling these cavities with tissue-equivalent mixtures. Moreover, different radiation dosimeters can be placed in the lower part of the model. For the second concept, AM was used for building modules like the phantom outer shell and bones, so that different mixtures can be used as a filling, without modifying the phantom structure. CT as well as Micro-CT scans of both concepts showed an excellent quality and adequate image contrast, with material attenuation properties close to those of mouse tissues, apart from the current bone surrogates. Radiation dose measurements with radiochromic films were, with some exceptions in areas with larges bone volumes, in agreement with calculations within less than ±4%. . AM shows great potential for the development of mouse models that are inexpensive, easy to adapt, and accurate, thus enabling their use for quality assurance in small-animal radiotherapy and imaging. The introduction of such 3D-printable mouse phantoms in the workflow could also significantly reduce the use of living animals for optimization and testing of new imaging and irradiation protocols.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>36930984</pmid><doi>10.1088/1361-6560/acc566</doi><tpages>17</tpages><orcidid>https://orcid.org/0000-0001-8616-859X</orcidid><orcidid>https://orcid.org/0000-0002-1253-1699</orcidid><orcidid>https://orcid.org/0000-0002-8204-0609</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2023-04, Vol.68 (8), p.85009
issn 0031-9155
1361-6560
language eng
recordid cdi_proquest_miscellaneous_2796158066
source MEDLINE; IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects additive manufacturing
Animals
dosimetry
Mice
Monte Carlo simulation
mouse phantom
Phantoms, Imaging
Radiobiology
Radiometry - methods
Radiotherapy Dosage
small-animal irradiation
X-Ray Microtomography
title Development and characterization of modular mouse phantoms for end-to-end testing and training in radiobiology experiments
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T13%3A38%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20and%20characterization%20of%20modular%20mouse%20phantoms%20for%20end-to-end%20testing%20and%20training%20in%20radiobiology%20experiments&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Wegner,%20Marie&rft.date=2023-04-21&rft.volume=68&rft.issue=8&rft.spage=85009&rft.pages=85009-&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/1361-6560/acc566&rft_dat=%3Cproquest_pubme%3E2796158066%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2796158066&rft_id=info:pmid/36930984&rfr_iscdi=true