Development of an in situ equilibrium polydimethylsiloxane passive sampler for measuring volatile organic compounds in soil vapor
An equilibrium passive sampler made of polydimethylsiloxane (PDMS) fiber was developed to measure volatile organic compounds (VOCs) in soil vapor. Expanded polytetrafluoroethylene (ePTFE) was used to protect PDMS from pollution and direct contact with soil components. For all tested VOCs, equilibriu...
Gespeichert in:
Veröffentlicht in: | Chemosphere (Oxford) 2023-06, Vol.325, p.138419-138419, Article 138419 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An equilibrium passive sampler made of polydimethylsiloxane (PDMS) fiber was developed to measure volatile organic compounds (VOCs) in soil vapor. Expanded polytetrafluoroethylene (ePTFE) was used to protect PDMS from pollution and direct contact with soil components. For all tested VOCs, equilibrium was reached after 7 days at 5 °C. The equilibrium partition coefficients of VOCs between PDMS, gas, and water were measured at three different temperatures. The analyte concentrations in PDMS exposed to gas and water separately were almost the same, which suggests that Cgas and Cwater in soil pores can be accurately deduced from CPDMS after equilibrium at various temperatures. To evaluate the passive sampler, active sampling measurements were performed simultaneously. Concentrations of VOCs deduced from the passive sampler were consistent with the concentrations measured by active sampling near the 1:1 line. Tests with artificial soils were conducted to observe the effects of soil components on passive sampling. The results suggest that the effect of water saturation can be ignored; in other words, the developed passive sampler can be applied in the vadose zone, which has fluctuating water saturation. With a holder for the sampler made of stainless steel, the developed in situ passive sampler can measure VOCs in contaminated soil vapor. The developed passive sampler was proven to be an alternative for measuring VOCs in soil vapor, which can be helpful for soil risk assessment and for observing the diffusion of VOCs in contaminated sites.
[Display omitted]
•An equilibrium passive sampler was developed to measure VOCs in the soil vapor.•Cgas and Cwater in soil pores can be accurately deduced from CPDMS.•To evaluate the passive sampler, active sampling was performed simultaneously.•Tests were conducted to observe the effects of soil components on passive sampling.•A holder for the sampler made of stainless steel was used for field applications. |
---|---|
ISSN: | 0045-6535 1879-1298 |
DOI: | 10.1016/j.chemosphere.2023.138419 |