A microfluidic actuator based on thermoresponsive hydrogels

We have evaluated the potential use of thermoresponsive hydrogels based on N-isopropylacrylamide as actuators in microfluidic and lab-on-a-chip devices. This required fabrication of hydrogel actuators on the μm length scale, anisotropic swelling of the resulting materials, and control over the kinet...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Polymer (Guilford) 2003-07, Vol.44 (16), p.4547-4556
Hauptverfasser: Harmon, Marianne E, Tang, Mary, Frank, Curtis W
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4556
container_issue 16
container_start_page 4547
container_title Polymer (Guilford)
container_volume 44
creator Harmon, Marianne E
Tang, Mary
Frank, Curtis W
description We have evaluated the potential use of thermoresponsive hydrogels based on N-isopropylacrylamide as actuators in microfluidic and lab-on-a-chip devices. This required fabrication of hydrogel actuators on the μm length scale, anisotropic swelling of the resulting materials, and control over the kinetics of the hydrogel volume phase transition. The fabrication procedure combined gel polymerization and casting techniques from the life sciences with more traditional semiconductor fabrication protocols for spin-coating, patterning, and etching. The actuator design used a PDMS membrane to separate the hydrogel actuator from the microfluidic channel and a separate reservoir for fluid to swell the actuator. As a result, the actuator could control flow for organic as well as aqueous solutions over a wide range of pH and ionic strength. The presence of a fixed substrate causes the gel swelling to be highly anisotropic, and the actuating motion is perpendicular to the substrate. The anisotropic swelling also limits the degree of swelling for the responsive hydrogel, and the total volume change is lower than the corresponding bulk materials by as much as an order of magnitude. The resulting actuators conform easily to the shape of the microfluidic channel, and the rate of the hydrogel response could be increased by using a series of semi-interpenetrating hydrogel networks. The microfluidic channels ranged in diameter from 180 to 380 μm, and the typical actuator was between 100 to 500 μm in diameter. The time scale of the actuator response was approximated by fitting with a single exponential (∼exp[−t/τ]). The time scale (τ) varied as a function of the actuator size and composition, ranging from 10 min to less than 10 s.
doi_str_mv 10.1016/S0032-3861(03)00463-4
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_27838549</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0032386103004634</els_id><sourcerecordid>27838549</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-75836c721952b77acded4b94b69b9f0fc47fbe6531a989e7656cd00e2fd5d2ad3</originalsourceid><addsrcrecordid>eNqFkEtLxDAUhYMoOI7-BKEbRRfVvJo2uJBh8AUDLtR1SJMbJ9JpxqQdmH9v54EuXd3Nd8_hfAidE3xDMBG3bxgzmrNKkCvMrjHmguX8AI1IVbKcUkkO0egXOUYnKX1hjGlB-QjdTbKFNzG4pvfWm0ybrtddiFmtE9gstFk3h7gIEdIytMmvIJuvbQyf0KRTdOR0k-Bsf8fo4_Hhffqcz16fXqaTWW6YqLq8LComTEmJLGhdltpYsLyWvBaylg47w0tXgygY0bKSUIpCGIsxUGcLS7VlY3S5y13G8N1D6tTCJwNNo1sIfVK0rFhVcDmAxQ4cBqUUwall9Asd14pgtVGltqrUxoPCTG1VKT78XewLdDK6cVG3xqe_5yFaMk4H7n7HDeNh5SGqZDy0BqyPYDplg_-n6QfJqH2_</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>27838549</pqid></control><display><type>article</type><title>A microfluidic actuator based on thermoresponsive hydrogels</title><source>Elsevier ScienceDirect Journals</source><creator>Harmon, Marianne E ; Tang, Mary ; Frank, Curtis W</creator><creatorcontrib>Harmon, Marianne E ; Tang, Mary ; Frank, Curtis W</creatorcontrib><description>We have evaluated the potential use of thermoresponsive hydrogels based on N-isopropylacrylamide as actuators in microfluidic and lab-on-a-chip devices. This required fabrication of hydrogel actuators on the μm length scale, anisotropic swelling of the resulting materials, and control over the kinetics of the hydrogel volume phase transition. The fabrication procedure combined gel polymerization and casting techniques from the life sciences with more traditional semiconductor fabrication protocols for spin-coating, patterning, and etching. The actuator design used a PDMS membrane to separate the hydrogel actuator from the microfluidic channel and a separate reservoir for fluid to swell the actuator. As a result, the actuator could control flow for organic as well as aqueous solutions over a wide range of pH and ionic strength. The presence of a fixed substrate causes the gel swelling to be highly anisotropic, and the actuating motion is perpendicular to the substrate. The anisotropic swelling also limits the degree of swelling for the responsive hydrogel, and the total volume change is lower than the corresponding bulk materials by as much as an order of magnitude. The resulting actuators conform easily to the shape of the microfluidic channel, and the rate of the hydrogel response could be increased by using a series of semi-interpenetrating hydrogel networks. The microfluidic channels ranged in diameter from 180 to 380 μm, and the typical actuator was between 100 to 500 μm in diameter. The time scale of the actuator response was approximated by fitting with a single exponential (∼exp[−t/τ]). The time scale (τ) varied as a function of the actuator size and composition, ranging from 10 min to less than 10 s.</description><identifier>ISSN: 0032-3861</identifier><identifier>EISSN: 1873-2291</identifier><identifier>DOI: 10.1016/S0032-3861(03)00463-4</identifier><identifier>CODEN: POLMAG</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Actuators ; Application fields ; Applied sciences ; Exact sciences and technology ; Hydrogels ; Polymer industry, paints, wood ; Polymer materials ; Technology of polymers</subject><ispartof>Polymer (Guilford), 2003-07, Vol.44 (16), p.4547-4556</ispartof><rights>2003</rights><rights>2003 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-75836c721952b77acded4b94b69b9f0fc47fbe6531a989e7656cd00e2fd5d2ad3</citedby><cites>FETCH-LOGICAL-c368t-75836c721952b77acded4b94b69b9f0fc47fbe6531a989e7656cd00e2fd5d2ad3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0032-3861(03)00463-4$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,45974</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=14939342$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Harmon, Marianne E</creatorcontrib><creatorcontrib>Tang, Mary</creatorcontrib><creatorcontrib>Frank, Curtis W</creatorcontrib><title>A microfluidic actuator based on thermoresponsive hydrogels</title><title>Polymer (Guilford)</title><description>We have evaluated the potential use of thermoresponsive hydrogels based on N-isopropylacrylamide as actuators in microfluidic and lab-on-a-chip devices. This required fabrication of hydrogel actuators on the μm length scale, anisotropic swelling of the resulting materials, and control over the kinetics of the hydrogel volume phase transition. The fabrication procedure combined gel polymerization and casting techniques from the life sciences with more traditional semiconductor fabrication protocols for spin-coating, patterning, and etching. The actuator design used a PDMS membrane to separate the hydrogel actuator from the microfluidic channel and a separate reservoir for fluid to swell the actuator. As a result, the actuator could control flow for organic as well as aqueous solutions over a wide range of pH and ionic strength. The presence of a fixed substrate causes the gel swelling to be highly anisotropic, and the actuating motion is perpendicular to the substrate. The anisotropic swelling also limits the degree of swelling for the responsive hydrogel, and the total volume change is lower than the corresponding bulk materials by as much as an order of magnitude. The resulting actuators conform easily to the shape of the microfluidic channel, and the rate of the hydrogel response could be increased by using a series of semi-interpenetrating hydrogel networks. The microfluidic channels ranged in diameter from 180 to 380 μm, and the typical actuator was between 100 to 500 μm in diameter. The time scale of the actuator response was approximated by fitting with a single exponential (∼exp[−t/τ]). The time scale (τ) varied as a function of the actuator size and composition, ranging from 10 min to less than 10 s.</description><subject>Actuators</subject><subject>Application fields</subject><subject>Applied sciences</subject><subject>Exact sciences and technology</subject><subject>Hydrogels</subject><subject>Polymer industry, paints, wood</subject><subject>Polymer materials</subject><subject>Technology of polymers</subject><issn>0032-3861</issn><issn>1873-2291</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><recordid>eNqFkEtLxDAUhYMoOI7-BKEbRRfVvJo2uJBh8AUDLtR1SJMbJ9JpxqQdmH9v54EuXd3Nd8_hfAidE3xDMBG3bxgzmrNKkCvMrjHmguX8AI1IVbKcUkkO0egXOUYnKX1hjGlB-QjdTbKFNzG4pvfWm0ybrtddiFmtE9gstFk3h7gIEdIytMmvIJuvbQyf0KRTdOR0k-Bsf8fo4_Hhffqcz16fXqaTWW6YqLq8LComTEmJLGhdltpYsLyWvBaylg47w0tXgygY0bKSUIpCGIsxUGcLS7VlY3S5y13G8N1D6tTCJwNNo1sIfVK0rFhVcDmAxQ4cBqUUwall9Asd14pgtVGltqrUxoPCTG1VKT78XewLdDK6cVG3xqe_5yFaMk4H7n7HDeNh5SGqZDy0BqyPYDplg_-n6QfJqH2_</recordid><startdate>20030701</startdate><enddate>20030701</enddate><creator>Harmon, Marianne E</creator><creator>Tang, Mary</creator><creator>Frank, Curtis W</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope></search><sort><creationdate>20030701</creationdate><title>A microfluidic actuator based on thermoresponsive hydrogels</title><author>Harmon, Marianne E ; Tang, Mary ; Frank, Curtis W</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-75836c721952b77acded4b94b69b9f0fc47fbe6531a989e7656cd00e2fd5d2ad3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Actuators</topic><topic>Application fields</topic><topic>Applied sciences</topic><topic>Exact sciences and technology</topic><topic>Hydrogels</topic><topic>Polymer industry, paints, wood</topic><topic>Polymer materials</topic><topic>Technology of polymers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Harmon, Marianne E</creatorcontrib><creatorcontrib>Tang, Mary</creatorcontrib><creatorcontrib>Frank, Curtis W</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><jtitle>Polymer (Guilford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Harmon, Marianne E</au><au>Tang, Mary</au><au>Frank, Curtis W</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A microfluidic actuator based on thermoresponsive hydrogels</atitle><jtitle>Polymer (Guilford)</jtitle><date>2003-07-01</date><risdate>2003</risdate><volume>44</volume><issue>16</issue><spage>4547</spage><epage>4556</epage><pages>4547-4556</pages><issn>0032-3861</issn><eissn>1873-2291</eissn><coden>POLMAG</coden><abstract>We have evaluated the potential use of thermoresponsive hydrogels based on N-isopropylacrylamide as actuators in microfluidic and lab-on-a-chip devices. This required fabrication of hydrogel actuators on the μm length scale, anisotropic swelling of the resulting materials, and control over the kinetics of the hydrogel volume phase transition. The fabrication procedure combined gel polymerization and casting techniques from the life sciences with more traditional semiconductor fabrication protocols for spin-coating, patterning, and etching. The actuator design used a PDMS membrane to separate the hydrogel actuator from the microfluidic channel and a separate reservoir for fluid to swell the actuator. As a result, the actuator could control flow for organic as well as aqueous solutions over a wide range of pH and ionic strength. The presence of a fixed substrate causes the gel swelling to be highly anisotropic, and the actuating motion is perpendicular to the substrate. The anisotropic swelling also limits the degree of swelling for the responsive hydrogel, and the total volume change is lower than the corresponding bulk materials by as much as an order of magnitude. The resulting actuators conform easily to the shape of the microfluidic channel, and the rate of the hydrogel response could be increased by using a series of semi-interpenetrating hydrogel networks. The microfluidic channels ranged in diameter from 180 to 380 μm, and the typical actuator was between 100 to 500 μm in diameter. The time scale of the actuator response was approximated by fitting with a single exponential (∼exp[−t/τ]). The time scale (τ) varied as a function of the actuator size and composition, ranging from 10 min to less than 10 s.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/S0032-3861(03)00463-4</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0032-3861
ispartof Polymer (Guilford), 2003-07, Vol.44 (16), p.4547-4556
issn 0032-3861
1873-2291
language eng
recordid cdi_proquest_miscellaneous_27838549
source Elsevier ScienceDirect Journals
subjects Actuators
Application fields
Applied sciences
Exact sciences and technology
Hydrogels
Polymer industry, paints, wood
Polymer materials
Technology of polymers
title A microfluidic actuator based on thermoresponsive hydrogels
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T11%3A38%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20microfluidic%20actuator%20based%20on%20thermoresponsive%20hydrogels&rft.jtitle=Polymer%20(Guilford)&rft.au=Harmon,%20Marianne%20E&rft.date=2003-07-01&rft.volume=44&rft.issue=16&rft.spage=4547&rft.epage=4556&rft.pages=4547-4556&rft.issn=0032-3861&rft.eissn=1873-2291&rft.coden=POLMAG&rft_id=info:doi/10.1016/S0032-3861(03)00463-4&rft_dat=%3Cproquest_cross%3E27838549%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=27838549&rft_id=info:pmid/&rft_els_id=S0032386103004634&rfr_iscdi=true