On minimal focal distance of a focused ultrasound probe for neuromodulation
Focal distance is a key parameter for a focused ultrasound probe, especially in mouse brain stimulation where targets are right below the skull. A closed-form solution for the minimal focal distance with a given transducer size was derived in this study to facilitate precise focal spot alignment wit...
Gespeichert in:
Veröffentlicht in: | JASA express letters 2023-02, Vol.3 (2), p.024002-024002 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 024002 |
---|---|
container_issue | 2 |
container_start_page | 024002 |
container_title | JASA express letters |
container_volume | 3 |
creator | Chu, Ya-Cherng Ho, Chien-Ying Chuo, Yue Wu, Hao-Hsuan Wang, Jaw-Lin |
description | Focal distance is a key parameter for a focused ultrasound probe, especially in mouse brain stimulation where targets are right below the skull. A closed-form solution for the minimal focal distance with a given transducer size was derived in this study to facilitate precise focal spot alignment with targets in the mouse brain. The spherical profile corresponding to the minimal focal distance does not produce accurate focusing. An iterative algorithm based on Snell's law was introduced for lens profile calculation. With a suitable step size, an accurate lens profile can be obtained for the minimal focal distance. |
doi_str_mv | 10.1121/10.0017106 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2781622281</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2781622281</sourcerecordid><originalsourceid>FETCH-LOGICAL-c282t-f670c39712739d0ab618a0959165cb4a4c65f0ac18abca1dae5806378763a7cd3</originalsourceid><addsrcrecordid>eNpNkE1LAzEQhoMotlYv_gDJUYTVTNLNx1FK_cBCL3peskkWVnaTmmwO_ntTWsXLvMM7D8PMi9A1kHsACg9FCQEBhJ-gOeUKKgAFp__6GbpI6ZMQDpSzczRjXNZSqXqO3rYej73vRz3gLphSbZ8m7Y3DocN67-XkLM7DFHUK2Vu8i6F1ZRCxdzmGMdg86KkP_hKddXpI7uqoC_TxtH5fvVSb7fPr6nFTGSrpVHVcEMOUACqYskS3HKQmqlbAa9Mu9dLwuiPaFLc1Gqx2tSScCSk408JYtkC3h73lkq_s0tSMfTJuGLR3IaeGCgmcUiqhoHcH1MSQUnRds4vl1_jdAGn24e31GF6Bb457czs6-4f-psV-AEwyaLo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2781622281</pqid></control><display><type>article</type><title>On minimal focal distance of a focused ultrasound probe for neuromodulation</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Chu, Ya-Cherng ; Ho, Chien-Ying ; Chuo, Yue ; Wu, Hao-Hsuan ; Wang, Jaw-Lin</creator><creatorcontrib>Chu, Ya-Cherng ; Ho, Chien-Ying ; Chuo, Yue ; Wu, Hao-Hsuan ; Wang, Jaw-Lin</creatorcontrib><description>Focal distance is a key parameter for a focused ultrasound probe, especially in mouse brain stimulation where targets are right below the skull. A closed-form solution for the minimal focal distance with a given transducer size was derived in this study to facilitate precise focal spot alignment with targets in the mouse brain. The spherical profile corresponding to the minimal focal distance does not produce accurate focusing. An iterative algorithm based on Snell's law was introduced for lens profile calculation. With a suitable step size, an accurate lens profile can be obtained for the minimal focal distance.</description><identifier>ISSN: 2691-1191</identifier><identifier>EISSN: 2691-1191</identifier><identifier>DOI: 10.1121/10.0017106</identifier><identifier>PMID: 36858995</identifier><language>eng</language><publisher>United States</publisher><ispartof>JASA express letters, 2023-02, Vol.3 (2), p.024002-024002</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c282t-f670c39712739d0ab618a0959165cb4a4c65f0ac18abca1dae5806378763a7cd3</cites><orcidid>0000-0002-5734-9276 ; 0000-0002-6408-2813</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36858995$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chu, Ya-Cherng</creatorcontrib><creatorcontrib>Ho, Chien-Ying</creatorcontrib><creatorcontrib>Chuo, Yue</creatorcontrib><creatorcontrib>Wu, Hao-Hsuan</creatorcontrib><creatorcontrib>Wang, Jaw-Lin</creatorcontrib><title>On minimal focal distance of a focused ultrasound probe for neuromodulation</title><title>JASA express letters</title><addtitle>JASA Express Lett</addtitle><description>Focal distance is a key parameter for a focused ultrasound probe, especially in mouse brain stimulation where targets are right below the skull. A closed-form solution for the minimal focal distance with a given transducer size was derived in this study to facilitate precise focal spot alignment with targets in the mouse brain. The spherical profile corresponding to the minimal focal distance does not produce accurate focusing. An iterative algorithm based on Snell's law was introduced for lens profile calculation. With a suitable step size, an accurate lens profile can be obtained for the minimal focal distance.</description><issn>2691-1191</issn><issn>2691-1191</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNpNkE1LAzEQhoMotlYv_gDJUYTVTNLNx1FK_cBCL3peskkWVnaTmmwO_ntTWsXLvMM7D8PMi9A1kHsACg9FCQEBhJ-gOeUKKgAFp__6GbpI6ZMQDpSzczRjXNZSqXqO3rYej73vRz3gLphSbZ8m7Y3DocN67-XkLM7DFHUK2Vu8i6F1ZRCxdzmGMdg86KkP_hKddXpI7uqoC_TxtH5fvVSb7fPr6nFTGSrpVHVcEMOUACqYskS3HKQmqlbAa9Mu9dLwuiPaFLc1Gqx2tSScCSk408JYtkC3h73lkq_s0tSMfTJuGLR3IaeGCgmcUiqhoHcH1MSQUnRds4vl1_jdAGn24e31GF6Bb457czs6-4f-psV-AEwyaLo</recordid><startdate>202302</startdate><enddate>202302</enddate><creator>Chu, Ya-Cherng</creator><creator>Ho, Chien-Ying</creator><creator>Chuo, Yue</creator><creator>Wu, Hao-Hsuan</creator><creator>Wang, Jaw-Lin</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-5734-9276</orcidid><orcidid>https://orcid.org/0000-0002-6408-2813</orcidid></search><sort><creationdate>202302</creationdate><title>On minimal focal distance of a focused ultrasound probe for neuromodulation</title><author>Chu, Ya-Cherng ; Ho, Chien-Ying ; Chuo, Yue ; Wu, Hao-Hsuan ; Wang, Jaw-Lin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c282t-f670c39712739d0ab618a0959165cb4a4c65f0ac18abca1dae5806378763a7cd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chu, Ya-Cherng</creatorcontrib><creatorcontrib>Ho, Chien-Ying</creatorcontrib><creatorcontrib>Chuo, Yue</creatorcontrib><creatorcontrib>Wu, Hao-Hsuan</creatorcontrib><creatorcontrib>Wang, Jaw-Lin</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>JASA express letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chu, Ya-Cherng</au><au>Ho, Chien-Ying</au><au>Chuo, Yue</au><au>Wu, Hao-Hsuan</au><au>Wang, Jaw-Lin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On minimal focal distance of a focused ultrasound probe for neuromodulation</atitle><jtitle>JASA express letters</jtitle><addtitle>JASA Express Lett</addtitle><date>2023-02</date><risdate>2023</risdate><volume>3</volume><issue>2</issue><spage>024002</spage><epage>024002</epage><pages>024002-024002</pages><issn>2691-1191</issn><eissn>2691-1191</eissn><abstract>Focal distance is a key parameter for a focused ultrasound probe, especially in mouse brain stimulation where targets are right below the skull. A closed-form solution for the minimal focal distance with a given transducer size was derived in this study to facilitate precise focal spot alignment with targets in the mouse brain. The spherical profile corresponding to the minimal focal distance does not produce accurate focusing. An iterative algorithm based on Snell's law was introduced for lens profile calculation. With a suitable step size, an accurate lens profile can be obtained for the minimal focal distance.</abstract><cop>United States</cop><pmid>36858995</pmid><doi>10.1121/10.0017106</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0002-5734-9276</orcidid><orcidid>https://orcid.org/0000-0002-6408-2813</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2691-1191 |
ispartof | JASA express letters, 2023-02, Vol.3 (2), p.024002-024002 |
issn | 2691-1191 2691-1191 |
language | eng |
recordid | cdi_proquest_miscellaneous_2781622281 |
source | DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection |
title | On minimal focal distance of a focused ultrasound probe for neuromodulation |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T16%3A08%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On%20minimal%20focal%20distance%20of%20a%20focused%20ultrasound%20probe%20for%20neuromodulation&rft.jtitle=JASA%20express%20letters&rft.au=Chu,%20Ya-Cherng&rft.date=2023-02&rft.volume=3&rft.issue=2&rft.spage=024002&rft.epage=024002&rft.pages=024002-024002&rft.issn=2691-1191&rft.eissn=2691-1191&rft_id=info:doi/10.1121/10.0017106&rft_dat=%3Cproquest_cross%3E2781622281%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2781622281&rft_id=info:pmid/36858995&rfr_iscdi=true |