Occlusion and Stability of Two Different Femoral Canal Plugs in Cemented Hip Arthroplasty. A Prospective and Randomized Study, with a Two Year Follow-Up

The aim of this prospective and randomised study was to test the ability of two different femoral plugs to seal off the femoral canal to prevent cement leakage, displacement of the restrictor and early aseptic loosening. Seventy patients, 35 in each of two groups, were included. There were 31 men an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Hip international 2003-07, Vol.13 (3), p.142-147
Hauptverfasser: Freund, K.G., Houshian, S., Riegels-Nielsen, P.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 147
container_issue 3
container_start_page 142
container_title Hip international
container_volume 13
creator Freund, K.G.
Houshian, S.
Riegels-Nielsen, P.
description The aim of this prospective and randomised study was to test the ability of two different femoral plugs to seal off the femoral canal to prevent cement leakage, displacement of the restrictor and early aseptic loosening. Seventy patients, 35 in each of two groups, were included. There were 31 men and 39 women. The average age was 70 years; the follow-up was two years. In group 1 (the Exeter plug) there were four cases with cement leakage and in group 2 there were three (the DePuy plug). There were four cases with failures in group 1, due to technical failure peroperatively, and none in group 2. Two cases with early mechanical loosening were found in group 1 and none in group 2. Both restrictors were found equivalent in their ability to occlude the femoral canal but peroperatively there seem to be technical difficulties with the Exeter restrictor.
doi_str_mv 10.1177/112070000301300304
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_27812632</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>27812632</sourcerecordid><originalsourceid>FETCH-LOGICAL-c191t-650c373ebeee967d6e2c5200620bcc53c9d3848828282aa8a19c1d3e13074ec93</originalsourceid><addsrcrecordid>eNplUU1PwzAMrRBIjMEf4JQTJzry0TXtcRqMIU0agu3AqcpSlwWlTUlSpvFL-LmkGzds6dmSn96T7Si6JnhECOd3hFDMcQiGCesxOYkGhNMkTnHKT0MfCHHPOI8unPvAmNJ8nAyin6WUunPKNEg0JXr1YqO08ntkKrTaGXSvqgosNB7NoDZWaDQVTcBn3b07pBo0hTpMoURz1aKJ9VtrWi2c34_QBD1b41qQXn3BQf4lgKnVN_ROXbm_RTvlt0gcrN5AWDQzWptdvG4vo7NKaAdXf3UYrWcPq-k8Xiwfn6aTRSxJTnycjrFknMEGAPKUlylQOaYYpxRvpBwzmZcsS7KM9ilEJkguSckgXIknIHM2jG6Ouq01nx04X9TKSdBaNGA6V1CeEZoyGoj0SJRhKWehKlqramH3BcFF_4Ti_xPYLwhQego</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>27812632</pqid></control><display><type>article</type><title>Occlusion and Stability of Two Different Femoral Canal Plugs in Cemented Hip Arthroplasty. A Prospective and Randomized Study, with a Two Year Follow-Up</title><source>SAGE Complete A-Z List</source><creator>Freund, K.G. ; Houshian, S. ; Riegels-Nielsen, P.</creator><creatorcontrib>Freund, K.G. ; Houshian, S. ; Riegels-Nielsen, P.</creatorcontrib><description>The aim of this prospective and randomised study was to test the ability of two different femoral plugs to seal off the femoral canal to prevent cement leakage, displacement of the restrictor and early aseptic loosening. Seventy patients, 35 in each of two groups, were included. There were 31 men and 39 women. The average age was 70 years; the follow-up was two years. In group 1 (the Exeter plug) there were four cases with cement leakage and in group 2 there were three (the DePuy plug). There were four cases with failures in group 1, due to technical failure peroperatively, and none in group 2. Two cases with early mechanical loosening were found in group 1 and none in group 2. Both restrictors were found equivalent in their ability to occlude the femoral canal but peroperatively there seem to be technical difficulties with the Exeter restrictor.</description><identifier>ISSN: 1120-7000</identifier><identifier>EISSN: 1724-6067</identifier><identifier>DOI: 10.1177/112070000301300304</identifier><language>eng</language><ispartof>Hip international, 2003-07, Vol.13 (3), p.142-147</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c191t-650c373ebeee967d6e2c5200620bcc53c9d3848828282aa8a19c1d3e13074ec93</citedby><cites>FETCH-LOGICAL-c191t-650c373ebeee967d6e2c5200620bcc53c9d3848828282aa8a19c1d3e13074ec93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids></links><search><creatorcontrib>Freund, K.G.</creatorcontrib><creatorcontrib>Houshian, S.</creatorcontrib><creatorcontrib>Riegels-Nielsen, P.</creatorcontrib><title>Occlusion and Stability of Two Different Femoral Canal Plugs in Cemented Hip Arthroplasty. A Prospective and Randomized Study, with a Two Year Follow-Up</title><title>Hip international</title><description>The aim of this prospective and randomised study was to test the ability of two different femoral plugs to seal off the femoral canal to prevent cement leakage, displacement of the restrictor and early aseptic loosening. Seventy patients, 35 in each of two groups, were included. There were 31 men and 39 women. The average age was 70 years; the follow-up was two years. In group 1 (the Exeter plug) there were four cases with cement leakage and in group 2 there were three (the DePuy plug). There were four cases with failures in group 1, due to technical failure peroperatively, and none in group 2. Two cases with early mechanical loosening were found in group 1 and none in group 2. Both restrictors were found equivalent in their ability to occlude the femoral canal but peroperatively there seem to be technical difficulties with the Exeter restrictor.</description><issn>1120-7000</issn><issn>1724-6067</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><recordid>eNplUU1PwzAMrRBIjMEf4JQTJzry0TXtcRqMIU0agu3AqcpSlwWlTUlSpvFL-LmkGzds6dmSn96T7Si6JnhECOd3hFDMcQiGCesxOYkGhNMkTnHKT0MfCHHPOI8unPvAmNJ8nAyin6WUunPKNEg0JXr1YqO08ntkKrTaGXSvqgosNB7NoDZWaDQVTcBn3b07pBo0hTpMoURz1aKJ9VtrWi2c34_QBD1b41qQXn3BQf4lgKnVN_ROXbm_RTvlt0gcrN5AWDQzWptdvG4vo7NKaAdXf3UYrWcPq-k8Xiwfn6aTRSxJTnycjrFknMEGAPKUlylQOaYYpxRvpBwzmZcsS7KM9ilEJkguSckgXIknIHM2jG6Ouq01nx04X9TKSdBaNGA6V1CeEZoyGoj0SJRhKWehKlqramH3BcFF_4Ti_xPYLwhQego</recordid><startdate>20030701</startdate><enddate>20030701</enddate><creator>Freund, K.G.</creator><creator>Houshian, S.</creator><creator>Riegels-Nielsen, P.</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>20030701</creationdate><title>Occlusion and Stability of Two Different Femoral Canal Plugs in Cemented Hip Arthroplasty. A Prospective and Randomized Study, with a Two Year Follow-Up</title><author>Freund, K.G. ; Houshian, S. ; Riegels-Nielsen, P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c191t-650c373ebeee967d6e2c5200620bcc53c9d3848828282aa8a19c1d3e13074ec93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Freund, K.G.</creatorcontrib><creatorcontrib>Houshian, S.</creatorcontrib><creatorcontrib>Riegels-Nielsen, P.</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Hip international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Freund, K.G.</au><au>Houshian, S.</au><au>Riegels-Nielsen, P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Occlusion and Stability of Two Different Femoral Canal Plugs in Cemented Hip Arthroplasty. A Prospective and Randomized Study, with a Two Year Follow-Up</atitle><jtitle>Hip international</jtitle><date>2003-07-01</date><risdate>2003</risdate><volume>13</volume><issue>3</issue><spage>142</spage><epage>147</epage><pages>142-147</pages><issn>1120-7000</issn><eissn>1724-6067</eissn><abstract>The aim of this prospective and randomised study was to test the ability of two different femoral plugs to seal off the femoral canal to prevent cement leakage, displacement of the restrictor and early aseptic loosening. Seventy patients, 35 in each of two groups, were included. There were 31 men and 39 women. The average age was 70 years; the follow-up was two years. In group 1 (the Exeter plug) there were four cases with cement leakage and in group 2 there were three (the DePuy plug). There were four cases with failures in group 1, due to technical failure peroperatively, and none in group 2. Two cases with early mechanical loosening were found in group 1 and none in group 2. Both restrictors were found equivalent in their ability to occlude the femoral canal but peroperatively there seem to be technical difficulties with the Exeter restrictor.</abstract><doi>10.1177/112070000301300304</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1120-7000
ispartof Hip international, 2003-07, Vol.13 (3), p.142-147
issn 1120-7000
1724-6067
language eng
recordid cdi_proquest_miscellaneous_27812632
source SAGE Complete A-Z List
title Occlusion and Stability of Two Different Femoral Canal Plugs in Cemented Hip Arthroplasty. A Prospective and Randomized Study, with a Two Year Follow-Up
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T13%3A42%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Occlusion%20and%20Stability%20of%20Two%20Different%20Femoral%20Canal%20Plugs%20in%20Cemented%20Hip%20Arthroplasty.%20A%20Prospective%20and%20Randomized%20Study,%20with%20a%20Two%20Year%20Follow-Up&rft.jtitle=Hip%20international&rft.au=Freund,%20K.G.&rft.date=2003-07-01&rft.volume=13&rft.issue=3&rft.spage=142&rft.epage=147&rft.pages=142-147&rft.issn=1120-7000&rft.eissn=1724-6067&rft_id=info:doi/10.1177/112070000301300304&rft_dat=%3Cproquest_cross%3E27812632%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=27812632&rft_id=info:pmid/&rfr_iscdi=true