Automated rapid solid-phase extraction system for separation and preconcentration of trace elements using carboxymethylated polyethyleneimine-type chelating resin

An automated system for the rapid separation and preconcentration of trace elements was developed. Carboxymethylated polyethyleneimine 600 (CM-PEI600), which is a partially carboxymethylated polyethyleneimine with a molecular weight of 600 Da, was used as a chelating resin to quantitatively recover...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical sciences 2023-04, Vol.39 (4), p.589-600
Hauptverfasser: Yokota, Yuki, Gemmei-Ide, Makoto, Inoue, Yoshinori, Kagaya, Shigehiro
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 600
container_issue 4
container_start_page 589
container_title Analytical sciences
container_volume 39
creator Yokota, Yuki
Gemmei-Ide, Makoto
Inoue, Yoshinori
Kagaya, Shigehiro
description An automated system for the rapid separation and preconcentration of trace elements was developed. Carboxymethylated polyethyleneimine 600 (CM-PEI600), which is a partially carboxymethylated polyethyleneimine with a molecular weight of 600 Da, was used as a chelating resin to quantitatively recover trace elements under high-flow-rate conditions. For accurately and precisely determining trace elements, even with a rough control of the sample and eluent flow volumes, an internal standardization technique was employed for the solid-phase extraction and separation. A recovery test of the deionized water-based sample solution was conducted using this system, and good results, with a recovery of 92% or higher, were obtained for 11 elements (Cd, Co, Cu, Fe, Mn, Mo, Ni, Pb, Ti, V, and Zn). Eight elements present in certified groundwater and wastewater reference materials (ES-L-1 and EU-L) were separated and preconcentrated using this system. Almost all the determined values were within their tolerance intervals, and no significant differences were observed between the determined and certified values, demonstrating the validity of this method. The time required for the separation and preconcentration using approximately 100 mL of the sample solution was approximately 6.5 min, and theoretically, the system could be used to preconcentrate 17 samples in an hour because extraction and elution could be conducted simultaneously using two cartridges packed with the chelating resin. Using this system equipped with cartridges packed with CM-PEI600 resin, solid-phase extraction and the separation of multiple elements were performed simultaneously, automatically, and rapidly, enabling the accurate and precise determination of trace elements in environmental water and inorganic salts even by rapidly flowing the sample solutions using peristaltic pumps. Compared to NOBIAS Chelate PA-1, a commercially available chelating resin, the CM-PEI600 resin can recover trace elements even under an extremely high flow rate of approximately 50 mL min –1 . Graphical abstract
doi_str_mv 10.1007/s44211-023-00277-w
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2774268123</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2774268123</sourcerecordid><originalsourceid>FETCH-LOGICAL-c457t-fd8d5c6d8219654b58d80420e30e6c3f0a1704df3a79363c29206e2022d0a8f13</originalsourceid><addsrcrecordid>eNp9kctu1TAURS0EopfCDzBAHjIxHD_iJMOq4iVVYgJjy9c-6U2V2MF21OZ3-FJ8HzBkZHmfvfaRvQl5y-EDB2g_ZqUE5wyEZACibdnjM7LjUnVMCKWfkx30HJiWCq7Iq5wfALjohHhJrqRuVd9oviO_b9YSZ1vQ02SX0dMcp9Gz5WAzUnwqyboyxkDzlgvOdIiJZlxssifVBk-XhC4Gh6FcxDjQI1bxCecqZ7rmMdxTZ9M-Pm0zlsM2nTYucdpONww4zmNAVrYFqTtgnR-RhJV8TV4Mdsr45nJek5-fP_24_cruvn_5dntzx5xq2sIG3_nGad8J3utG7ZvOd6AEoATUTg5geQvKD9K2vdTSiV6ARgFCeLDdwOU1eX_OXVL8tWIuZh6zw2myAeOaTf1hJXTHhaxWcba6FHNOOJgljbNNm-Fgjt2YczemdmNO3ZjHCr275K_7Gf0_5G8Z1SDPhlxH4R6TeYhrCvXN_4v9A_P2n5s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2774268123</pqid></control><display><type>article</type><title>Automated rapid solid-phase extraction system for separation and preconcentration of trace elements using carboxymethylated polyethyleneimine-type chelating resin</title><source>Freely Accessible Japanese Titles</source><source>EZB-FREE-00999 freely available EZB journals</source><source>SpringerLink Journals - AutoHoldings</source><creator>Yokota, Yuki ; Gemmei-Ide, Makoto ; Inoue, Yoshinori ; Kagaya, Shigehiro</creator><creatorcontrib>Yokota, Yuki ; Gemmei-Ide, Makoto ; Inoue, Yoshinori ; Kagaya, Shigehiro</creatorcontrib><description>An automated system for the rapid separation and preconcentration of trace elements was developed. Carboxymethylated polyethyleneimine 600 (CM-PEI600), which is a partially carboxymethylated polyethyleneimine with a molecular weight of 600 Da, was used as a chelating resin to quantitatively recover trace elements under high-flow-rate conditions. For accurately and precisely determining trace elements, even with a rough control of the sample and eluent flow volumes, an internal standardization technique was employed for the solid-phase extraction and separation. A recovery test of the deionized water-based sample solution was conducted using this system, and good results, with a recovery of 92% or higher, were obtained for 11 elements (Cd, Co, Cu, Fe, Mn, Mo, Ni, Pb, Ti, V, and Zn). Eight elements present in certified groundwater and wastewater reference materials (ES-L-1 and EU-L) were separated and preconcentrated using this system. Almost all the determined values were within their tolerance intervals, and no significant differences were observed between the determined and certified values, demonstrating the validity of this method. The time required for the separation and preconcentration using approximately 100 mL of the sample solution was approximately 6.5 min, and theoretically, the system could be used to preconcentrate 17 samples in an hour because extraction and elution could be conducted simultaneously using two cartridges packed with the chelating resin. Using this system equipped with cartridges packed with CM-PEI600 resin, solid-phase extraction and the separation of multiple elements were performed simultaneously, automatically, and rapidly, enabling the accurate and precise determination of trace elements in environmental water and inorganic salts even by rapidly flowing the sample solutions using peristaltic pumps. Compared to NOBIAS Chelate PA-1, a commercially available chelating resin, the CM-PEI600 resin can recover trace elements even under an extremely high flow rate of approximately 50 mL min –1 . Graphical abstract</description><identifier>ISSN: 0910-6340</identifier><identifier>EISSN: 1348-2246</identifier><identifier>DOI: 10.1007/s44211-023-00277-w</identifier><identifier>PMID: 36749561</identifier><language>eng</language><publisher>Singapore: Springer Nature Singapore</publisher><subject>Analytical Chemistry ; Chemistry ; Chemistry and Materials Science ; Original Paper</subject><ispartof>Analytical sciences, 2023-04, Vol.39 (4), p.589-600</ispartof><rights>The Author(s), under exclusive licence to The Japan Society for Analytical Chemistry 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.</rights><rights>2023. The Author(s), under exclusive licence to The Japan Society for Analytical Chemistry.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c457t-fd8d5c6d8219654b58d80420e30e6c3f0a1704df3a79363c29206e2022d0a8f13</citedby><cites>FETCH-LOGICAL-c457t-fd8d5c6d8219654b58d80420e30e6c3f0a1704df3a79363c29206e2022d0a8f13</cites><orcidid>0000-0002-9226-9431 ; 0000-0001-9448-1869 ; 0000-0001-7352-8015</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s44211-023-00277-w$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s44211-023-00277-w$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27923,27924,41487,42556,51318</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36749561$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yokota, Yuki</creatorcontrib><creatorcontrib>Gemmei-Ide, Makoto</creatorcontrib><creatorcontrib>Inoue, Yoshinori</creatorcontrib><creatorcontrib>Kagaya, Shigehiro</creatorcontrib><title>Automated rapid solid-phase extraction system for separation and preconcentration of trace elements using carboxymethylated polyethyleneimine-type chelating resin</title><title>Analytical sciences</title><addtitle>ANAL. SCI</addtitle><addtitle>Anal Sci</addtitle><description>An automated system for the rapid separation and preconcentration of trace elements was developed. Carboxymethylated polyethyleneimine 600 (CM-PEI600), which is a partially carboxymethylated polyethyleneimine with a molecular weight of 600 Da, was used as a chelating resin to quantitatively recover trace elements under high-flow-rate conditions. For accurately and precisely determining trace elements, even with a rough control of the sample and eluent flow volumes, an internal standardization technique was employed for the solid-phase extraction and separation. A recovery test of the deionized water-based sample solution was conducted using this system, and good results, with a recovery of 92% or higher, were obtained for 11 elements (Cd, Co, Cu, Fe, Mn, Mo, Ni, Pb, Ti, V, and Zn). Eight elements present in certified groundwater and wastewater reference materials (ES-L-1 and EU-L) were separated and preconcentrated using this system. Almost all the determined values were within their tolerance intervals, and no significant differences were observed between the determined and certified values, demonstrating the validity of this method. The time required for the separation and preconcentration using approximately 100 mL of the sample solution was approximately 6.5 min, and theoretically, the system could be used to preconcentrate 17 samples in an hour because extraction and elution could be conducted simultaneously using two cartridges packed with the chelating resin. Using this system equipped with cartridges packed with CM-PEI600 resin, solid-phase extraction and the separation of multiple elements were performed simultaneously, automatically, and rapidly, enabling the accurate and precise determination of trace elements in environmental water and inorganic salts even by rapidly flowing the sample solutions using peristaltic pumps. Compared to NOBIAS Chelate PA-1, a commercially available chelating resin, the CM-PEI600 resin can recover trace elements even under an extremely high flow rate of approximately 50 mL min –1 . Graphical abstract</description><subject>Analytical Chemistry</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Original Paper</subject><issn>0910-6340</issn><issn>1348-2246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kctu1TAURS0EopfCDzBAHjIxHD_iJMOq4iVVYgJjy9c-6U2V2MF21OZ3-FJ8HzBkZHmfvfaRvQl5y-EDB2g_ZqUE5wyEZACibdnjM7LjUnVMCKWfkx30HJiWCq7Iq5wfALjohHhJrqRuVd9oviO_b9YSZ1vQ02SX0dMcp9Gz5WAzUnwqyboyxkDzlgvOdIiJZlxssifVBk-XhC4Gh6FcxDjQI1bxCecqZ7rmMdxTZ9M-Pm0zlsM2nTYucdpONww4zmNAVrYFqTtgnR-RhJV8TV4Mdsr45nJek5-fP_24_cruvn_5dntzx5xq2sIG3_nGad8J3utG7ZvOd6AEoATUTg5geQvKD9K2vdTSiV6ARgFCeLDdwOU1eX_OXVL8tWIuZh6zw2myAeOaTf1hJXTHhaxWcba6FHNOOJgljbNNm-Fgjt2YczemdmNO3ZjHCr275K_7Gf0_5G8Z1SDPhlxH4R6TeYhrCvXN_4v9A_P2n5s</recordid><startdate>20230401</startdate><enddate>20230401</enddate><creator>Yokota, Yuki</creator><creator>Gemmei-Ide, Makoto</creator><creator>Inoue, Yoshinori</creator><creator>Kagaya, Shigehiro</creator><general>Springer Nature Singapore</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-9226-9431</orcidid><orcidid>https://orcid.org/0000-0001-9448-1869</orcidid><orcidid>https://orcid.org/0000-0001-7352-8015</orcidid></search><sort><creationdate>20230401</creationdate><title>Automated rapid solid-phase extraction system for separation and preconcentration of trace elements using carboxymethylated polyethyleneimine-type chelating resin</title><author>Yokota, Yuki ; Gemmei-Ide, Makoto ; Inoue, Yoshinori ; Kagaya, Shigehiro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c457t-fd8d5c6d8219654b58d80420e30e6c3f0a1704df3a79363c29206e2022d0a8f13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Analytical Chemistry</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Original Paper</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yokota, Yuki</creatorcontrib><creatorcontrib>Gemmei-Ide, Makoto</creatorcontrib><creatorcontrib>Inoue, Yoshinori</creatorcontrib><creatorcontrib>Kagaya, Shigehiro</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yokota, Yuki</au><au>Gemmei-Ide, Makoto</au><au>Inoue, Yoshinori</au><au>Kagaya, Shigehiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Automated rapid solid-phase extraction system for separation and preconcentration of trace elements using carboxymethylated polyethyleneimine-type chelating resin</atitle><jtitle>Analytical sciences</jtitle><stitle>ANAL. SCI</stitle><addtitle>Anal Sci</addtitle><date>2023-04-01</date><risdate>2023</risdate><volume>39</volume><issue>4</issue><spage>589</spage><epage>600</epage><pages>589-600</pages><issn>0910-6340</issn><eissn>1348-2246</eissn><abstract>An automated system for the rapid separation and preconcentration of trace elements was developed. Carboxymethylated polyethyleneimine 600 (CM-PEI600), which is a partially carboxymethylated polyethyleneimine with a molecular weight of 600 Da, was used as a chelating resin to quantitatively recover trace elements under high-flow-rate conditions. For accurately and precisely determining trace elements, even with a rough control of the sample and eluent flow volumes, an internal standardization technique was employed for the solid-phase extraction and separation. A recovery test of the deionized water-based sample solution was conducted using this system, and good results, with a recovery of 92% or higher, were obtained for 11 elements (Cd, Co, Cu, Fe, Mn, Mo, Ni, Pb, Ti, V, and Zn). Eight elements present in certified groundwater and wastewater reference materials (ES-L-1 and EU-L) were separated and preconcentrated using this system. Almost all the determined values were within their tolerance intervals, and no significant differences were observed between the determined and certified values, demonstrating the validity of this method. The time required for the separation and preconcentration using approximately 100 mL of the sample solution was approximately 6.5 min, and theoretically, the system could be used to preconcentrate 17 samples in an hour because extraction and elution could be conducted simultaneously using two cartridges packed with the chelating resin. Using this system equipped with cartridges packed with CM-PEI600 resin, solid-phase extraction and the separation of multiple elements were performed simultaneously, automatically, and rapidly, enabling the accurate and precise determination of trace elements in environmental water and inorganic salts even by rapidly flowing the sample solutions using peristaltic pumps. Compared to NOBIAS Chelate PA-1, a commercially available chelating resin, the CM-PEI600 resin can recover trace elements even under an extremely high flow rate of approximately 50 mL min –1 . Graphical abstract</abstract><cop>Singapore</cop><pub>Springer Nature Singapore</pub><pmid>36749561</pmid><doi>10.1007/s44211-023-00277-w</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0002-9226-9431</orcidid><orcidid>https://orcid.org/0000-0001-9448-1869</orcidid><orcidid>https://orcid.org/0000-0001-7352-8015</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0910-6340
ispartof Analytical sciences, 2023-04, Vol.39 (4), p.589-600
issn 0910-6340
1348-2246
language eng
recordid cdi_proquest_miscellaneous_2774268123
source Freely Accessible Japanese Titles; EZB-FREE-00999 freely available EZB journals; SpringerLink Journals - AutoHoldings
subjects Analytical Chemistry
Chemistry
Chemistry and Materials Science
Original Paper
title Automated rapid solid-phase extraction system for separation and preconcentration of trace elements using carboxymethylated polyethyleneimine-type chelating resin
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T10%3A48%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Automated%20rapid%20solid-phase%20extraction%20system%20for%20separation%20and%20preconcentration%20of%20trace%20elements%20using%20carboxymethylated%20polyethyleneimine-type%20chelating%20resin&rft.jtitle=Analytical%20sciences&rft.au=Yokota,%20Yuki&rft.date=2023-04-01&rft.volume=39&rft.issue=4&rft.spage=589&rft.epage=600&rft.pages=589-600&rft.issn=0910-6340&rft.eissn=1348-2246&rft_id=info:doi/10.1007/s44211-023-00277-w&rft_dat=%3Cproquest_cross%3E2774268123%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2774268123&rft_id=info:pmid/36749561&rfr_iscdi=true