Aseptic glenoid baseplate loosening after reverse total shoulder arthroplasty with a single prosthesis

Early reverse total shoulder arthroplasty (rTSA) designs had high failure rates, mainly from loosening of the glenoid baseplate. The purpose of this study was to determine the incidence of aseptic glenoid baseplate loosening after primary rTSA using a contemporary medialized glenoid–lateralized hume...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of shoulder and elbow surgery 2023-08, Vol.32 (8), p.1584-1593
Hauptverfasser: Schell, Lauren E., Roche, Christopher P., Eichinger, Josef K., Flurin, Pierre-Henri, Wright, Thomas W., Zuckerman, Joseph D., Friedman, Richard J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1593
container_issue 8
container_start_page 1584
container_title Journal of shoulder and elbow surgery
container_volume 32
creator Schell, Lauren E.
Roche, Christopher P.
Eichinger, Josef K.
Flurin, Pierre-Henri
Wright, Thomas W.
Zuckerman, Joseph D.
Friedman, Richard J.
description Early reverse total shoulder arthroplasty (rTSA) designs had high failure rates, mainly from loosening of the glenoid baseplate. The purpose of this study was to determine the incidence of aseptic glenoid baseplate loosening after primary rTSA using a contemporary medialized glenoid–lateralized humerus system and identify significant risk factors associated with loosening. A total of 7162 patients underwent primary rTSA with a single-platform rTSA system between April 2007 and August 2021; of these primary rTSA patients, 3127 with a minimum 2-year follow-up period were identified. Patients with aseptic glenoid baseplate loosening were compared with all other primary rTSA patients without loosening. Univariate and multivariate analyses were performed to compare these cohorts and identify the demographic characteristics, comorbidities, operative parameters, and implant characteristics associated aseptic glenoid loosening after rTSA. Odds ratios (ORs) were calculated for each significant risk factor and for multiple combinations of risk factors. Irrespective of minimum follow-up, 53 of 7162 primary rTSA shoulders (31 female and 22 male shoulders) experienced aseptic glenoid loosening, for an overall rate of 0.74%. At latest (2-year minimum) follow-up, 30 of 3127 patients experienced aseptic glenoid loosening and showed significantly lower clinical scores, function, and active range of motion and higher pain scores than patients without loosening. Univariate analysis identified rheumatoid arthritis (P = .029; OR, 2.74) and diabetes (P = .028; OR, 1.84) as significant risk factors for aseptic glenoid loosening after rTSA, and multivariate analysis identified Walch glenoid types B2 (P = .002; OR, 4.513) and B3 (P = .002; OR, 14.804), use of expanded lateralized glenospheres (P = .025; OR, 2.57), and use of augmented baseplates (P = .001; OR, 2.50) as significant risk factors. The incidence of aseptic glenoid baseplate loosening was 0.74% for the evaluated medialized glenoid–lateralized humerus rTSA system. Numerous risk factors for aseptic loosening were identified, including rheumatoid arthritis, diabetes, Walch type B2 and B3 glenoids, posteriorly-superiorly augmented baseplates, and expanded lateralized glenospheres. Finally, analysis of multiple combinations of risk factors identified patients and implant configurations with the greatest risk of aseptic glenoid loosening.
doi_str_mv 10.1016/j.jse.2023.01.010
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2773115960</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1058274623000654</els_id><sourcerecordid>2773115960</sourcerecordid><originalsourceid>FETCH-LOGICAL-c353t-a744732b7d14eed8c0e0232b1a5eae9925302fbc59309f9928f8e8985cf6a9c13</originalsourceid><addsrcrecordid>eNp9UE1rGzEQFaWhcZ3-gF6KjrmsM5JW-0FPwbRpwNBLcxZa7WwsI69cjZyQfx8ZpzkWBuaD997MPMa-ClgJEM3NbrUjXEmQagWiBHxgC6GVrBoN8LHUoLtKtnVzyT4T7QCgr0F-YpeqaVXT6HbBplvCQ_aOPwacox_5YMsg2Iw8xEg4-_mR2ylj4gmfMBHyHLMNnLbxGMYytilvUywUyi_82ectt5wKKyA_pEh5i-Tpil1MNhB-ectL9vDzx5_1r2rz--5-fbupnNIqV7at61bJoR1FjTh2DrA8JwdhNVrse6kVyGlwulfQT6Xvpg67vtNuamzvhFqy67NuWf33iJTN3pPDEOyM8UhGtq0SQvcNFKg4Q125khJO5pD83qYXI8Cc7DU7U-w1J3sNiBInzrc3-eOwx_Gd8c_PAvh-BmB58sljMuQ8zg5Hn9BlM0b_H_lXzZmMug</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2773115960</pqid></control><display><type>article</type><title>Aseptic glenoid baseplate loosening after reverse total shoulder arthroplasty with a single prosthesis</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Schell, Lauren E. ; Roche, Christopher P. ; Eichinger, Josef K. ; Flurin, Pierre-Henri ; Wright, Thomas W. ; Zuckerman, Joseph D. ; Friedman, Richard J.</creator><creatorcontrib>Schell, Lauren E. ; Roche, Christopher P. ; Eichinger, Josef K. ; Flurin, Pierre-Henri ; Wright, Thomas W. ; Zuckerman, Joseph D. ; Friedman, Richard J.</creatorcontrib><description>Early reverse total shoulder arthroplasty (rTSA) designs had high failure rates, mainly from loosening of the glenoid baseplate. The purpose of this study was to determine the incidence of aseptic glenoid baseplate loosening after primary rTSA using a contemporary medialized glenoid–lateralized humerus system and identify significant risk factors associated with loosening. A total of 7162 patients underwent primary rTSA with a single-platform rTSA system between April 2007 and August 2021; of these primary rTSA patients, 3127 with a minimum 2-year follow-up period were identified. Patients with aseptic glenoid baseplate loosening were compared with all other primary rTSA patients without loosening. Univariate and multivariate analyses were performed to compare these cohorts and identify the demographic characteristics, comorbidities, operative parameters, and implant characteristics associated aseptic glenoid loosening after rTSA. Odds ratios (ORs) were calculated for each significant risk factor and for multiple combinations of risk factors. Irrespective of minimum follow-up, 53 of 7162 primary rTSA shoulders (31 female and 22 male shoulders) experienced aseptic glenoid loosening, for an overall rate of 0.74%. At latest (2-year minimum) follow-up, 30 of 3127 patients experienced aseptic glenoid loosening and showed significantly lower clinical scores, function, and active range of motion and higher pain scores than patients without loosening. Univariate analysis identified rheumatoid arthritis (P = .029; OR, 2.74) and diabetes (P = .028; OR, 1.84) as significant risk factors for aseptic glenoid loosening after rTSA, and multivariate analysis identified Walch glenoid types B2 (P = .002; OR, 4.513) and B3 (P = .002; OR, 14.804), use of expanded lateralized glenospheres (P = .025; OR, 2.57), and use of augmented baseplates (P = .001; OR, 2.50) as significant risk factors. The incidence of aseptic glenoid baseplate loosening was 0.74% for the evaluated medialized glenoid–lateralized humerus rTSA system. Numerous risk factors for aseptic loosening were identified, including rheumatoid arthritis, diabetes, Walch type B2 and B3 glenoids, posteriorly-superiorly augmented baseplates, and expanded lateralized glenospheres. Finally, analysis of multiple combinations of risk factors identified patients and implant configurations with the greatest risk of aseptic glenoid loosening.</description><identifier>ISSN: 1058-2746</identifier><identifier>EISSN: 1532-6500</identifier><identifier>DOI: 10.1016/j.jse.2023.01.010</identifier><identifier>PMID: 36736657</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>arthroplasty ; baseplate ; fixation ; glenoid ; loosening ; Reverse ; shoulder</subject><ispartof>Journal of shoulder and elbow surgery, 2023-08, Vol.32 (8), p.1584-1593</ispartof><rights>2023 Journal of Shoulder and Elbow Surgery Board of Trustees</rights><rights>Copyright © 2023 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c353t-a744732b7d14eed8c0e0232b1a5eae9925302fbc59309f9928f8e8985cf6a9c13</citedby><cites>FETCH-LOGICAL-c353t-a744732b7d14eed8c0e0232b1a5eae9925302fbc59309f9928f8e8985cf6a9c13</cites><orcidid>0000-0003-0696-1577 ; 0000-0001-8563-7307 ; 0000-0003-3801-3272 ; 0000-0001-9174-9874 ; 0000-0003-3072-9970 ; 0000-0002-5641-470X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1058274623000654$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36736657$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Schell, Lauren E.</creatorcontrib><creatorcontrib>Roche, Christopher P.</creatorcontrib><creatorcontrib>Eichinger, Josef K.</creatorcontrib><creatorcontrib>Flurin, Pierre-Henri</creatorcontrib><creatorcontrib>Wright, Thomas W.</creatorcontrib><creatorcontrib>Zuckerman, Joseph D.</creatorcontrib><creatorcontrib>Friedman, Richard J.</creatorcontrib><title>Aseptic glenoid baseplate loosening after reverse total shoulder arthroplasty with a single prosthesis</title><title>Journal of shoulder and elbow surgery</title><addtitle>J Shoulder Elbow Surg</addtitle><description>Early reverse total shoulder arthroplasty (rTSA) designs had high failure rates, mainly from loosening of the glenoid baseplate. The purpose of this study was to determine the incidence of aseptic glenoid baseplate loosening after primary rTSA using a contemporary medialized glenoid–lateralized humerus system and identify significant risk factors associated with loosening. A total of 7162 patients underwent primary rTSA with a single-platform rTSA system between April 2007 and August 2021; of these primary rTSA patients, 3127 with a minimum 2-year follow-up period were identified. Patients with aseptic glenoid baseplate loosening were compared with all other primary rTSA patients without loosening. Univariate and multivariate analyses were performed to compare these cohorts and identify the demographic characteristics, comorbidities, operative parameters, and implant characteristics associated aseptic glenoid loosening after rTSA. Odds ratios (ORs) were calculated for each significant risk factor and for multiple combinations of risk factors. Irrespective of minimum follow-up, 53 of 7162 primary rTSA shoulders (31 female and 22 male shoulders) experienced aseptic glenoid loosening, for an overall rate of 0.74%. At latest (2-year minimum) follow-up, 30 of 3127 patients experienced aseptic glenoid loosening and showed significantly lower clinical scores, function, and active range of motion and higher pain scores than patients without loosening. Univariate analysis identified rheumatoid arthritis (P = .029; OR, 2.74) and diabetes (P = .028; OR, 1.84) as significant risk factors for aseptic glenoid loosening after rTSA, and multivariate analysis identified Walch glenoid types B2 (P = .002; OR, 4.513) and B3 (P = .002; OR, 14.804), use of expanded lateralized glenospheres (P = .025; OR, 2.57), and use of augmented baseplates (P = .001; OR, 2.50) as significant risk factors. The incidence of aseptic glenoid baseplate loosening was 0.74% for the evaluated medialized glenoid–lateralized humerus rTSA system. Numerous risk factors for aseptic loosening were identified, including rheumatoid arthritis, diabetes, Walch type B2 and B3 glenoids, posteriorly-superiorly augmented baseplates, and expanded lateralized glenospheres. Finally, analysis of multiple combinations of risk factors identified patients and implant configurations with the greatest risk of aseptic glenoid loosening.</description><subject>arthroplasty</subject><subject>baseplate</subject><subject>fixation</subject><subject>glenoid</subject><subject>loosening</subject><subject>Reverse</subject><subject>shoulder</subject><issn>1058-2746</issn><issn>1532-6500</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9UE1rGzEQFaWhcZ3-gF6KjrmsM5JW-0FPwbRpwNBLcxZa7WwsI69cjZyQfx8ZpzkWBuaD997MPMa-ClgJEM3NbrUjXEmQagWiBHxgC6GVrBoN8LHUoLtKtnVzyT4T7QCgr0F-YpeqaVXT6HbBplvCQ_aOPwacox_5YMsg2Iw8xEg4-_mR2ylj4gmfMBHyHLMNnLbxGMYytilvUywUyi_82ectt5wKKyA_pEh5i-Tpil1MNhB-ectL9vDzx5_1r2rz--5-fbupnNIqV7at61bJoR1FjTh2DrA8JwdhNVrse6kVyGlwulfQT6Xvpg67vtNuamzvhFqy67NuWf33iJTN3pPDEOyM8UhGtq0SQvcNFKg4Q125khJO5pD83qYXI8Cc7DU7U-w1J3sNiBInzrc3-eOwx_Gd8c_PAvh-BmB58sljMuQ8zg5Hn9BlM0b_H_lXzZmMug</recordid><startdate>202308</startdate><enddate>202308</enddate><creator>Schell, Lauren E.</creator><creator>Roche, Christopher P.</creator><creator>Eichinger, Josef K.</creator><creator>Flurin, Pierre-Henri</creator><creator>Wright, Thomas W.</creator><creator>Zuckerman, Joseph D.</creator><creator>Friedman, Richard J.</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-0696-1577</orcidid><orcidid>https://orcid.org/0000-0001-8563-7307</orcidid><orcidid>https://orcid.org/0000-0003-3801-3272</orcidid><orcidid>https://orcid.org/0000-0001-9174-9874</orcidid><orcidid>https://orcid.org/0000-0003-3072-9970</orcidid><orcidid>https://orcid.org/0000-0002-5641-470X</orcidid></search><sort><creationdate>202308</creationdate><title>Aseptic glenoid baseplate loosening after reverse total shoulder arthroplasty with a single prosthesis</title><author>Schell, Lauren E. ; Roche, Christopher P. ; Eichinger, Josef K. ; Flurin, Pierre-Henri ; Wright, Thomas W. ; Zuckerman, Joseph D. ; Friedman, Richard J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c353t-a744732b7d14eed8c0e0232b1a5eae9925302fbc59309f9928f8e8985cf6a9c13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>arthroplasty</topic><topic>baseplate</topic><topic>fixation</topic><topic>glenoid</topic><topic>loosening</topic><topic>Reverse</topic><topic>shoulder</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Schell, Lauren E.</creatorcontrib><creatorcontrib>Roche, Christopher P.</creatorcontrib><creatorcontrib>Eichinger, Josef K.</creatorcontrib><creatorcontrib>Flurin, Pierre-Henri</creatorcontrib><creatorcontrib>Wright, Thomas W.</creatorcontrib><creatorcontrib>Zuckerman, Joseph D.</creatorcontrib><creatorcontrib>Friedman, Richard J.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of shoulder and elbow surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Schell, Lauren E.</au><au>Roche, Christopher P.</au><au>Eichinger, Josef K.</au><au>Flurin, Pierre-Henri</au><au>Wright, Thomas W.</au><au>Zuckerman, Joseph D.</au><au>Friedman, Richard J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Aseptic glenoid baseplate loosening after reverse total shoulder arthroplasty with a single prosthesis</atitle><jtitle>Journal of shoulder and elbow surgery</jtitle><addtitle>J Shoulder Elbow Surg</addtitle><date>2023-08</date><risdate>2023</risdate><volume>32</volume><issue>8</issue><spage>1584</spage><epage>1593</epage><pages>1584-1593</pages><issn>1058-2746</issn><eissn>1532-6500</eissn><abstract>Early reverse total shoulder arthroplasty (rTSA) designs had high failure rates, mainly from loosening of the glenoid baseplate. The purpose of this study was to determine the incidence of aseptic glenoid baseplate loosening after primary rTSA using a contemporary medialized glenoid–lateralized humerus system and identify significant risk factors associated with loosening. A total of 7162 patients underwent primary rTSA with a single-platform rTSA system between April 2007 and August 2021; of these primary rTSA patients, 3127 with a minimum 2-year follow-up period were identified. Patients with aseptic glenoid baseplate loosening were compared with all other primary rTSA patients without loosening. Univariate and multivariate analyses were performed to compare these cohorts and identify the demographic characteristics, comorbidities, operative parameters, and implant characteristics associated aseptic glenoid loosening after rTSA. Odds ratios (ORs) were calculated for each significant risk factor and for multiple combinations of risk factors. Irrespective of minimum follow-up, 53 of 7162 primary rTSA shoulders (31 female and 22 male shoulders) experienced aseptic glenoid loosening, for an overall rate of 0.74%. At latest (2-year minimum) follow-up, 30 of 3127 patients experienced aseptic glenoid loosening and showed significantly lower clinical scores, function, and active range of motion and higher pain scores than patients without loosening. Univariate analysis identified rheumatoid arthritis (P = .029; OR, 2.74) and diabetes (P = .028; OR, 1.84) as significant risk factors for aseptic glenoid loosening after rTSA, and multivariate analysis identified Walch glenoid types B2 (P = .002; OR, 4.513) and B3 (P = .002; OR, 14.804), use of expanded lateralized glenospheres (P = .025; OR, 2.57), and use of augmented baseplates (P = .001; OR, 2.50) as significant risk factors. The incidence of aseptic glenoid baseplate loosening was 0.74% for the evaluated medialized glenoid–lateralized humerus rTSA system. Numerous risk factors for aseptic loosening were identified, including rheumatoid arthritis, diabetes, Walch type B2 and B3 glenoids, posteriorly-superiorly augmented baseplates, and expanded lateralized glenospheres. Finally, analysis of multiple combinations of risk factors identified patients and implant configurations with the greatest risk of aseptic glenoid loosening.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>36736657</pmid><doi>10.1016/j.jse.2023.01.010</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0003-0696-1577</orcidid><orcidid>https://orcid.org/0000-0001-8563-7307</orcidid><orcidid>https://orcid.org/0000-0003-3801-3272</orcidid><orcidid>https://orcid.org/0000-0001-9174-9874</orcidid><orcidid>https://orcid.org/0000-0003-3072-9970</orcidid><orcidid>https://orcid.org/0000-0002-5641-470X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1058-2746
ispartof Journal of shoulder and elbow surgery, 2023-08, Vol.32 (8), p.1584-1593
issn 1058-2746
1532-6500
language eng
recordid cdi_proquest_miscellaneous_2773115960
source ScienceDirect Journals (5 years ago - present)
subjects arthroplasty
baseplate
fixation
glenoid
loosening
Reverse
shoulder
title Aseptic glenoid baseplate loosening after reverse total shoulder arthroplasty with a single prosthesis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T14%3A00%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Aseptic%20glenoid%20baseplate%20loosening%20after%20reverse%20total%20shoulder%20arthroplasty%20with%20a%20single%20prosthesis&rft.jtitle=Journal%20of%20shoulder%20and%20elbow%20surgery&rft.au=Schell,%20Lauren%20E.&rft.date=2023-08&rft.volume=32&rft.issue=8&rft.spage=1584&rft.epage=1593&rft.pages=1584-1593&rft.issn=1058-2746&rft.eissn=1532-6500&rft_id=info:doi/10.1016/j.jse.2023.01.010&rft_dat=%3Cproquest_cross%3E2773115960%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2773115960&rft_id=info:pmid/36736657&rft_els_id=S1058274623000654&rfr_iscdi=true