Reproducibility of low-level residual myeloma immunoglobulin detection using ultra-deep sequencing

•Detection of low-level myeloma residual disease using deep sequencing of clonal immunoglobulin rearrangements is reproducible in a controlled setup using the LymphoTrack assay.•Residual myeloma cells can consistently be quantified by employing an internal deoxyribonucleic acid control.•The nontechn...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Experimental hematology 2023-03, Vol.119-120, p.14-20
Hauptverfasser: Cédile, Oriane, Hansen, Marcus Høy, Dahlmann, Sara Kamuk, Kristensen, Thomas Kielsgaard, Abildgaard, Niels, Nyvold, Charlotte Guldborg
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 20
container_issue
container_start_page 14
container_title Experimental hematology
container_volume 119-120
creator Cédile, Oriane
Hansen, Marcus Høy
Dahlmann, Sara Kamuk
Kristensen, Thomas Kielsgaard
Abildgaard, Niels
Nyvold, Charlotte Guldborg
description •Detection of low-level myeloma residual disease using deep sequencing of clonal immunoglobulin rearrangements is reproducible in a controlled setup using the LymphoTrack assay.•Residual myeloma cells can consistently be quantified by employing an internal deoxyribonucleic acid control.•The nontechnical replicate failure rate of low-level residual disease detection by sequencing is a stochastic process. Multiple myeloma, a mature B-cell neoplasm, is the second most common hematologic malignancy. Despite advancements in treatment, the disease remains incurable, with more than 100,000 annual deaths worldwide. As recommended by the International Myeloma Working Group, measurable residual disease (MRD) should be addressed at a 10−5 sensitivity level or beyond for practical purposes. Next-generation sequencing (NGS) has provided new opportunities with deep sequencing of clonal rearrangements of the immunoglobulin heavy chain (IGH) locus in B-cell malignancies. Although the ability to resolve one cancerous cell in a million other B cells is becoming attractive as a prognostic indicator in sustained patients who are MRD-negative, reaching consistent sensitivity levels is challenging because of sample stochasticity and the substantial amount of deoxyribonucleic acid (DNA) required for library preparation. Thus, in the presented study, we implemented ultra-deep sequencing of rearranged IGH to investigate the reproducibility and consistency aimed at the 10−5 sensitivity level. In this controlled setup, our data provided stable MRD detection of 1.2 clonal cells per 100,000 analyzed cells and longitudinal reproducibility. We also demonstrated a low false-negative rate using 4–5 replicates and 700–800 ng DNA per sequencing replicate. In conclusion, adding an internal control to the replicates enabled clonal cell normalization for MRD evaluation as a stable reference. These findings may guide MRD-level reporting and comparisons between laboratories.
doi_str_mv 10.1016/j.exphem.2023.01.002
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2770480154</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0301472X2300022X</els_id><sourcerecordid>2770480154</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-a8c13d706c80ddf1bd8382c840066cc248b8c76c5504b63c17e6d4584031a86e3</originalsourceid><addsrcrecordid>eNp9kN1rFDEUxYNY7Fr9D0Ty6MuMNx-TZF8EKfUDCkJpwbcwk9ytWTKTNZlU9783ZauPPl2495x7OD9C3jDoGTD1ft_j78MPnHsOXPTAegD-jGyY0aLjYrt9TjYggHVS8-_n5GUpewAYhi28IOdCaTBG8w2ZbvCQk68uTCGG9UjTjsb0q4v4gJFmLMHXMdL5iDHNIw3zXJd0H9NUY1ioxxXdGtJCawnLPa1xzWPnEQ-04M-Ki2vbV-RsN8aCr5_mBbn7dHV7-aW7_vb56-XH685JMGs3GseE16CcAe93bPJGGO6MBFDKOS7NZJxWbhhATko4plF5ObS7YKNRKC7Iu9PfVqhll9XOoTiMcVww1WK51iANsEE2qTxJXU6lZNzZQw7zmI-WgX2ka_f2RNc-0rXAbKPbbG-fEuo0o_9n-ouzCT6cBNh6PgTMtrjQKKAPuYGyPoX_J_wBUMmO7w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2770480154</pqid></control><display><type>article</type><title>Reproducibility of low-level residual myeloma immunoglobulin detection using ultra-deep sequencing</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Cédile, Oriane ; Hansen, Marcus Høy ; Dahlmann, Sara Kamuk ; Kristensen, Thomas Kielsgaard ; Abildgaard, Niels ; Nyvold, Charlotte Guldborg</creator><creatorcontrib>Cédile, Oriane ; Hansen, Marcus Høy ; Dahlmann, Sara Kamuk ; Kristensen, Thomas Kielsgaard ; Abildgaard, Niels ; Nyvold, Charlotte Guldborg</creatorcontrib><description>•Detection of low-level myeloma residual disease using deep sequencing of clonal immunoglobulin rearrangements is reproducible in a controlled setup using the LymphoTrack assay.•Residual myeloma cells can consistently be quantified by employing an internal deoxyribonucleic acid control.•The nontechnical replicate failure rate of low-level residual disease detection by sequencing is a stochastic process. Multiple myeloma, a mature B-cell neoplasm, is the second most common hematologic malignancy. Despite advancements in treatment, the disease remains incurable, with more than 100,000 annual deaths worldwide. As recommended by the International Myeloma Working Group, measurable residual disease (MRD) should be addressed at a 10−5 sensitivity level or beyond for practical purposes. Next-generation sequencing (NGS) has provided new opportunities with deep sequencing of clonal rearrangements of the immunoglobulin heavy chain (IGH) locus in B-cell malignancies. Although the ability to resolve one cancerous cell in a million other B cells is becoming attractive as a prognostic indicator in sustained patients who are MRD-negative, reaching consistent sensitivity levels is challenging because of sample stochasticity and the substantial amount of deoxyribonucleic acid (DNA) required for library preparation. Thus, in the presented study, we implemented ultra-deep sequencing of rearranged IGH to investigate the reproducibility and consistency aimed at the 10−5 sensitivity level. In this controlled setup, our data provided stable MRD detection of 1.2 clonal cells per 100,000 analyzed cells and longitudinal reproducibility. We also demonstrated a low false-negative rate using 4–5 replicates and 700–800 ng DNA per sequencing replicate. In conclusion, adding an internal control to the replicates enabled clonal cell normalization for MRD evaluation as a stable reference. These findings may guide MRD-level reporting and comparisons between laboratories.</description><identifier>ISSN: 0301-472X</identifier><identifier>EISSN: 1873-2399</identifier><identifier>DOI: 10.1016/j.exphem.2023.01.002</identifier><identifier>PMID: 36708872</identifier><language>eng</language><publisher>Netherlands: Elsevier Inc</publisher><subject>DNA ; High-Throughput Nucleotide Sequencing ; Humans ; Multiple Myeloma - diagnosis ; Multiple Myeloma - genetics ; Multiple Myeloma - pathology ; Neoplasm, Residual - diagnosis ; Neoplasm, Residual - genetics ; Reproducibility of Results</subject><ispartof>Experimental hematology, 2023-03, Vol.119-120, p.14-20</ispartof><rights>2023 ISEH -- Society for Hematology and Stem Cells</rights><rights>Copyright © 2023 ISEH -- Society for Hematology and Stem Cells. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-a8c13d706c80ddf1bd8382c840066cc248b8c76c5504b63c17e6d4584031a86e3</citedby><cites>FETCH-LOGICAL-c408t-a8c13d706c80ddf1bd8382c840066cc248b8c76c5504b63c17e6d4584031a86e3</cites><orcidid>0000-0003-3083-4850 ; 0000-0002-6427-4276 ; 0000-0002-0411-7594</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,27931,27932</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36708872$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cédile, Oriane</creatorcontrib><creatorcontrib>Hansen, Marcus Høy</creatorcontrib><creatorcontrib>Dahlmann, Sara Kamuk</creatorcontrib><creatorcontrib>Kristensen, Thomas Kielsgaard</creatorcontrib><creatorcontrib>Abildgaard, Niels</creatorcontrib><creatorcontrib>Nyvold, Charlotte Guldborg</creatorcontrib><title>Reproducibility of low-level residual myeloma immunoglobulin detection using ultra-deep sequencing</title><title>Experimental hematology</title><addtitle>Exp Hematol</addtitle><description>•Detection of low-level myeloma residual disease using deep sequencing of clonal immunoglobulin rearrangements is reproducible in a controlled setup using the LymphoTrack assay.•Residual myeloma cells can consistently be quantified by employing an internal deoxyribonucleic acid control.•The nontechnical replicate failure rate of low-level residual disease detection by sequencing is a stochastic process. Multiple myeloma, a mature B-cell neoplasm, is the second most common hematologic malignancy. Despite advancements in treatment, the disease remains incurable, with more than 100,000 annual deaths worldwide. As recommended by the International Myeloma Working Group, measurable residual disease (MRD) should be addressed at a 10−5 sensitivity level or beyond for practical purposes. Next-generation sequencing (NGS) has provided new opportunities with deep sequencing of clonal rearrangements of the immunoglobulin heavy chain (IGH) locus in B-cell malignancies. Although the ability to resolve one cancerous cell in a million other B cells is becoming attractive as a prognostic indicator in sustained patients who are MRD-negative, reaching consistent sensitivity levels is challenging because of sample stochasticity and the substantial amount of deoxyribonucleic acid (DNA) required for library preparation. Thus, in the presented study, we implemented ultra-deep sequencing of rearranged IGH to investigate the reproducibility and consistency aimed at the 10−5 sensitivity level. In this controlled setup, our data provided stable MRD detection of 1.2 clonal cells per 100,000 analyzed cells and longitudinal reproducibility. We also demonstrated a low false-negative rate using 4–5 replicates and 700–800 ng DNA per sequencing replicate. In conclusion, adding an internal control to the replicates enabled clonal cell normalization for MRD evaluation as a stable reference. These findings may guide MRD-level reporting and comparisons between laboratories.</description><subject>DNA</subject><subject>High-Throughput Nucleotide Sequencing</subject><subject>Humans</subject><subject>Multiple Myeloma - diagnosis</subject><subject>Multiple Myeloma - genetics</subject><subject>Multiple Myeloma - pathology</subject><subject>Neoplasm, Residual - diagnosis</subject><subject>Neoplasm, Residual - genetics</subject><subject>Reproducibility of Results</subject><issn>0301-472X</issn><issn>1873-2399</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kN1rFDEUxYNY7Fr9D0Ty6MuMNx-TZF8EKfUDCkJpwbcwk9ytWTKTNZlU9783ZauPPl2495x7OD9C3jDoGTD1ft_j78MPnHsOXPTAegD-jGyY0aLjYrt9TjYggHVS8-_n5GUpewAYhi28IOdCaTBG8w2ZbvCQk68uTCGG9UjTjsb0q4v4gJFmLMHXMdL5iDHNIw3zXJd0H9NUY1ioxxXdGtJCawnLPa1xzWPnEQ-04M-Ki2vbV-RsN8aCr5_mBbn7dHV7-aW7_vb56-XH685JMGs3GseE16CcAe93bPJGGO6MBFDKOS7NZJxWbhhATko4plF5ObS7YKNRKC7Iu9PfVqhll9XOoTiMcVww1WK51iANsEE2qTxJXU6lZNzZQw7zmI-WgX2ka_f2RNc-0rXAbKPbbG-fEuo0o_9n-ouzCT6cBNh6PgTMtrjQKKAPuYGyPoX_J_wBUMmO7w</recordid><startdate>202303</startdate><enddate>202303</enddate><creator>Cédile, Oriane</creator><creator>Hansen, Marcus Høy</creator><creator>Dahlmann, Sara Kamuk</creator><creator>Kristensen, Thomas Kielsgaard</creator><creator>Abildgaard, Niels</creator><creator>Nyvold, Charlotte Guldborg</creator><general>Elsevier Inc</general><scope>6I.</scope><scope>AAFTH</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-3083-4850</orcidid><orcidid>https://orcid.org/0000-0002-6427-4276</orcidid><orcidid>https://orcid.org/0000-0002-0411-7594</orcidid></search><sort><creationdate>202303</creationdate><title>Reproducibility of low-level residual myeloma immunoglobulin detection using ultra-deep sequencing</title><author>Cédile, Oriane ; Hansen, Marcus Høy ; Dahlmann, Sara Kamuk ; Kristensen, Thomas Kielsgaard ; Abildgaard, Niels ; Nyvold, Charlotte Guldborg</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-a8c13d706c80ddf1bd8382c840066cc248b8c76c5504b63c17e6d4584031a86e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>DNA</topic><topic>High-Throughput Nucleotide Sequencing</topic><topic>Humans</topic><topic>Multiple Myeloma - diagnosis</topic><topic>Multiple Myeloma - genetics</topic><topic>Multiple Myeloma - pathology</topic><topic>Neoplasm, Residual - diagnosis</topic><topic>Neoplasm, Residual - genetics</topic><topic>Reproducibility of Results</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cédile, Oriane</creatorcontrib><creatorcontrib>Hansen, Marcus Høy</creatorcontrib><creatorcontrib>Dahlmann, Sara Kamuk</creatorcontrib><creatorcontrib>Kristensen, Thomas Kielsgaard</creatorcontrib><creatorcontrib>Abildgaard, Niels</creatorcontrib><creatorcontrib>Nyvold, Charlotte Guldborg</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Experimental hematology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cédile, Oriane</au><au>Hansen, Marcus Høy</au><au>Dahlmann, Sara Kamuk</au><au>Kristensen, Thomas Kielsgaard</au><au>Abildgaard, Niels</au><au>Nyvold, Charlotte Guldborg</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reproducibility of low-level residual myeloma immunoglobulin detection using ultra-deep sequencing</atitle><jtitle>Experimental hematology</jtitle><addtitle>Exp Hematol</addtitle><date>2023-03</date><risdate>2023</risdate><volume>119-120</volume><spage>14</spage><epage>20</epage><pages>14-20</pages><issn>0301-472X</issn><eissn>1873-2399</eissn><abstract>•Detection of low-level myeloma residual disease using deep sequencing of clonal immunoglobulin rearrangements is reproducible in a controlled setup using the LymphoTrack assay.•Residual myeloma cells can consistently be quantified by employing an internal deoxyribonucleic acid control.•The nontechnical replicate failure rate of low-level residual disease detection by sequencing is a stochastic process. Multiple myeloma, a mature B-cell neoplasm, is the second most common hematologic malignancy. Despite advancements in treatment, the disease remains incurable, with more than 100,000 annual deaths worldwide. As recommended by the International Myeloma Working Group, measurable residual disease (MRD) should be addressed at a 10−5 sensitivity level or beyond for practical purposes. Next-generation sequencing (NGS) has provided new opportunities with deep sequencing of clonal rearrangements of the immunoglobulin heavy chain (IGH) locus in B-cell malignancies. Although the ability to resolve one cancerous cell in a million other B cells is becoming attractive as a prognostic indicator in sustained patients who are MRD-negative, reaching consistent sensitivity levels is challenging because of sample stochasticity and the substantial amount of deoxyribonucleic acid (DNA) required for library preparation. Thus, in the presented study, we implemented ultra-deep sequencing of rearranged IGH to investigate the reproducibility and consistency aimed at the 10−5 sensitivity level. In this controlled setup, our data provided stable MRD detection of 1.2 clonal cells per 100,000 analyzed cells and longitudinal reproducibility. We also demonstrated a low false-negative rate using 4–5 replicates and 700–800 ng DNA per sequencing replicate. In conclusion, adding an internal control to the replicates enabled clonal cell normalization for MRD evaluation as a stable reference. These findings may guide MRD-level reporting and comparisons between laboratories.</abstract><cop>Netherlands</cop><pub>Elsevier Inc</pub><pmid>36708872</pmid><doi>10.1016/j.exphem.2023.01.002</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0003-3083-4850</orcidid><orcidid>https://orcid.org/0000-0002-6427-4276</orcidid><orcidid>https://orcid.org/0000-0002-0411-7594</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0301-472X
ispartof Experimental hematology, 2023-03, Vol.119-120, p.14-20
issn 0301-472X
1873-2399
language eng
recordid cdi_proquest_miscellaneous_2770480154
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects DNA
High-Throughput Nucleotide Sequencing
Humans
Multiple Myeloma - diagnosis
Multiple Myeloma - genetics
Multiple Myeloma - pathology
Neoplasm, Residual - diagnosis
Neoplasm, Residual - genetics
Reproducibility of Results
title Reproducibility of low-level residual myeloma immunoglobulin detection using ultra-deep sequencing
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T07%3A23%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reproducibility%20of%20low-level%20residual%20myeloma%20immunoglobulin%20detection%20using%20ultra-deep%20sequencing&rft.jtitle=Experimental%20hematology&rft.au=C%C3%A9dile,%20Oriane&rft.date=2023-03&rft.volume=119-120&rft.spage=14&rft.epage=20&rft.pages=14-20&rft.issn=0301-472X&rft.eissn=1873-2399&rft_id=info:doi/10.1016/j.exphem.2023.01.002&rft_dat=%3Cproquest_cross%3E2770480154%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2770480154&rft_id=info:pmid/36708872&rft_els_id=S0301472X2300022X&rfr_iscdi=true