Rapid, sensitive, and specific lateral-flow immunochromatographic point-of-care device for detection of varicella-zoster virus immunoglobulin G antibodies in fingerstick blood

Varicella zoster virus (VZV) causes childhood chickenpox, becomes latent in sensory ganglia and reactivates years later to cause shingles (Zoster) and postherpetic neuralgia in the elderly and immunosuppressed individuals. Serologic IgG tests can be used to determine if a person has antibodies to VZ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of immunological methods 2023-03, Vol.514, p.113429-113429, Article 113429
Hauptverfasser: Vafai, Nicholas, Self, Kevin, Sheffield, Bret, Hojvat, Sally, Kusi-Appiah, Aubrey, Vaughan, Patrick, Cowan, Elliot, Vafai, Abbas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Varicella zoster virus (VZV) causes childhood chickenpox, becomes latent in sensory ganglia and reactivates years later to cause shingles (Zoster) and postherpetic neuralgia in the elderly and immunosuppressed individuals. Serologic IgG tests can be used to determine if a person has antibodies to VZV from past varicella infection or had received varicella or zoster (shingles) vaccination. Commercial enzyme-linked immunosorbent assays (ELISAs) are currently used for the detection of VZV IgG antibodies in patient serum samples. However, ELISA tests require collection and processing of blood samples in a CLIA laboratory to separate serum or plasma for further testing. In this paper, we describe the development and testing of an antibody based Lateral Flow Immunochromatographic assay (LFA) device for the detection of VZV IgG in fingerstick whole blood. Analytical and clinical analyses were performed to compare the performance characteristics of the Viro VZV IgG LFA (VZV LFA) and the Diamedix VZV IgG ELISA. Analytical studies demonstrated the higher sensitivity of the VZV LFA compared to the ELISA by testing dilutions of the WHO VZV IgG serum International Standard. Clinical performance characteristics of the VZV LFA fingerstick whole blood assay were assessed at three point of care (POC) facilities by untrained users testing samples from 300 prospectively enrolled study subjects. VZV LFA results were compared with results obtained by testing serum samples obtained from the same study participants by the Diamedix VZV IgG ELISA. Two specimens with invalid results by the LFA assay were not included in the LFA performance calculations and nine equivocal ELISA results were included as positive for IgG results. The results from all three POC clinical sites demonstrated the higher sensitivity/positive percent agreement (PPA) (99.26%, 95% CI: 97.34–99.80) of the VZV LFA compared to the Diamedix VZV IgG ELISA (94.08%, 95% CI: 90.72–96.27). The specificity/negative percent agreement (NPA) of the VZV LFA compared to the ELISA test was calculated initially to be 39.29% (95% CI: 23.57–57.59) with 19 discordant test results out of 298 test results between the two assays (17 LFA positive/ELISA negative and two LFA negative/ELISA positive). The PPA and true NPA of the VZV LFA were determined by testing all 298 samples, including the discordant (19) and all concordant negative and positive (279) study subject serum samples, before and after blocking VZV gE antibody sites in th
ISSN:0022-1759
1872-7905
DOI:10.1016/j.jim.2023.113429