Surgical results of transcutaneous bone-anchored hearing aid comparing the C-shaped and linear incision techniques

Purpose The aim of the study is to compare the operative time and postoperative complication outcomes for bone-anchored hearing aid (BAHA) implants using two different techniques: the C-shaped incision technique and the linear incision technique. Methods An analysis was carried out of 38 patients im...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European archives of oto-rhino-laryngology 2023-06, Vol.280 (6), p.2749-2754
Hauptverfasser: Miura, Mauricio Schneider, Ogando, Patrícia Barcelos, Pasqualini, Marina Paese, Neves, Hemily, Lubianca Neto, José Faibes
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2754
container_issue 6
container_start_page 2749
container_title European archives of oto-rhino-laryngology
container_volume 280
creator Miura, Mauricio Schneider
Ogando, Patrícia Barcelos
Pasqualini, Marina Paese
Neves, Hemily
Lubianca Neto, José Faibes
description Purpose The aim of the study is to compare the operative time and postoperative complication outcomes for bone-anchored hearing aid (BAHA) implants using two different techniques: the C-shaped incision technique and the linear incision technique. Methods An analysis was carried out of 38 patients implanted with transcutaneous BAHAs during a 4-year period in a single otolaryngology department. Results The implantation was carried out under general anesthesia. Operative time was significant lower with the linear technique compared to the C-shaped technique (76.55 min, SD 16.75 vs. 93.17 min, SD 19.82; p  = 0.007). There was no difference in postoperative complications between the two techniques. Conclusions The use of linear incision for transcutaneous BAHA system implantation is associated with a reduced surgery time compared to the C-shaped technique, with no increase in postoperative complications.
doi_str_mv 10.1007/s00405-022-07778-w
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2763333126</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2763333126</sourcerecordid><originalsourceid>FETCH-LOGICAL-c347t-9fc467d95104db906dd708b1d4ff5edecd37026c05bba1f65420ec9cc11cd62c3</originalsourceid><addsrcrecordid>eNp9kE1v1DAQhi1URJfCH-CAfOzFMP6IvTlWqxaQKnEAzpYzdhpXWTu1E1X992RJ2yNzGY30zDuah5BPHL5wAPO1AihoGAjBwBizZ49vyI4rqZgyQp-RHbTSMKWMOSfva70HgEa18h05l1qLZq_3O1J-LeUuohtpCXUZ50pzT-fiUsVldinkpdIup8BcwiGX4OkQXInpjrroKebjtE3zEOiB1cFNK-KSp2NMK0hjwlhjTnQOOKT4sIT6gbzt3VjDx-d-Qf7cXP8-fGe3P7_9OFzdMpTKzKztUWnj24aD8l0L2nsD-4571fdN8AG9NCA0QtN1jve6UQICtoico9cC5QW53HKnkk93Z3uMFcM4bm9ZYbRciwu9omJDseRaS-jtVOLRlSfLwZ5c2821XV3bf67t47r0-Tl_6Y7Bv668yF0BuQF1OjkKxd7npaT15__F_gX7Vo1F</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2763333126</pqid></control><display><type>article</type><title>Surgical results of transcutaneous bone-anchored hearing aid comparing the C-shaped and linear incision techniques</title><source>MEDLINE</source><source>SpringerLink Journals</source><creator>Miura, Mauricio Schneider ; Ogando, Patrícia Barcelos ; Pasqualini, Marina Paese ; Neves, Hemily ; Lubianca Neto, José Faibes</creator><creatorcontrib>Miura, Mauricio Schneider ; Ogando, Patrícia Barcelos ; Pasqualini, Marina Paese ; Neves, Hemily ; Lubianca Neto, José Faibes</creatorcontrib><description>Purpose The aim of the study is to compare the operative time and postoperative complication outcomes for bone-anchored hearing aid (BAHA) implants using two different techniques: the C-shaped incision technique and the linear incision technique. Methods An analysis was carried out of 38 patients implanted with transcutaneous BAHAs during a 4-year period in a single otolaryngology department. Results The implantation was carried out under general anesthesia. Operative time was significant lower with the linear technique compared to the C-shaped technique (76.55 min, SD 16.75 vs. 93.17 min, SD 19.82; p  = 0.007). There was no difference in postoperative complications between the two techniques. Conclusions The use of linear incision for transcutaneous BAHA system implantation is associated with a reduced surgery time compared to the C-shaped technique, with no increase in postoperative complications.</description><identifier>ISSN: 0937-4477</identifier><identifier>EISSN: 1434-4726</identifier><identifier>DOI: 10.1007/s00405-022-07778-w</identifier><identifier>PMID: 36625868</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Bone Conduction ; Ear ; Head and Neck Surgery ; Hearing Aids - adverse effects ; Hearing Loss, Conductive - surgery ; Humans ; Medicine ; Medicine &amp; Public Health ; Neurosurgery ; Otology ; Otorhinolaryngology ; Postoperative Complications - etiology ; Prosthesis Implantation - methods</subject><ispartof>European archives of oto-rhino-laryngology, 2023-06, Vol.280 (6), p.2749-2754</ispartof><rights>The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.</rights><rights>2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c347t-9fc467d95104db906dd708b1d4ff5edecd37026c05bba1f65420ec9cc11cd62c3</citedby><cites>FETCH-LOGICAL-c347t-9fc467d95104db906dd708b1d4ff5edecd37026c05bba1f65420ec9cc11cd62c3</cites><orcidid>0000-0002-1362-5072</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00405-022-07778-w$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00405-022-07778-w$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36625868$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Miura, Mauricio Schneider</creatorcontrib><creatorcontrib>Ogando, Patrícia Barcelos</creatorcontrib><creatorcontrib>Pasqualini, Marina Paese</creatorcontrib><creatorcontrib>Neves, Hemily</creatorcontrib><creatorcontrib>Lubianca Neto, José Faibes</creatorcontrib><title>Surgical results of transcutaneous bone-anchored hearing aid comparing the C-shaped and linear incision techniques</title><title>European archives of oto-rhino-laryngology</title><addtitle>Eur Arch Otorhinolaryngol</addtitle><addtitle>Eur Arch Otorhinolaryngol</addtitle><description>Purpose The aim of the study is to compare the operative time and postoperative complication outcomes for bone-anchored hearing aid (BAHA) implants using two different techniques: the C-shaped incision technique and the linear incision technique. Methods An analysis was carried out of 38 patients implanted with transcutaneous BAHAs during a 4-year period in a single otolaryngology department. Results The implantation was carried out under general anesthesia. Operative time was significant lower with the linear technique compared to the C-shaped technique (76.55 min, SD 16.75 vs. 93.17 min, SD 19.82; p  = 0.007). There was no difference in postoperative complications between the two techniques. Conclusions The use of linear incision for transcutaneous BAHA system implantation is associated with a reduced surgery time compared to the C-shaped technique, with no increase in postoperative complications.</description><subject>Bone Conduction</subject><subject>Ear</subject><subject>Head and Neck Surgery</subject><subject>Hearing Aids - adverse effects</subject><subject>Hearing Loss, Conductive - surgery</subject><subject>Humans</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Neurosurgery</subject><subject>Otology</subject><subject>Otorhinolaryngology</subject><subject>Postoperative Complications - etiology</subject><subject>Prosthesis Implantation - methods</subject><issn>0937-4477</issn><issn>1434-4726</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1v1DAQhi1URJfCH-CAfOzFMP6IvTlWqxaQKnEAzpYzdhpXWTu1E1X992RJ2yNzGY30zDuah5BPHL5wAPO1AihoGAjBwBizZ49vyI4rqZgyQp-RHbTSMKWMOSfva70HgEa18h05l1qLZq_3O1J-LeUuohtpCXUZ50pzT-fiUsVldinkpdIup8BcwiGX4OkQXInpjrroKebjtE3zEOiB1cFNK-KSp2NMK0hjwlhjTnQOOKT4sIT6gbzt3VjDx-d-Qf7cXP8-fGe3P7_9OFzdMpTKzKztUWnj24aD8l0L2nsD-4571fdN8AG9NCA0QtN1jve6UQICtoico9cC5QW53HKnkk93Z3uMFcM4bm9ZYbRciwu9omJDseRaS-jtVOLRlSfLwZ5c2821XV3bf67t47r0-Tl_6Y7Bv668yF0BuQF1OjkKxd7npaT15__F_gX7Vo1F</recordid><startdate>20230601</startdate><enddate>20230601</enddate><creator>Miura, Mauricio Schneider</creator><creator>Ogando, Patrícia Barcelos</creator><creator>Pasqualini, Marina Paese</creator><creator>Neves, Hemily</creator><creator>Lubianca Neto, José Faibes</creator><general>Springer Berlin Heidelberg</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-1362-5072</orcidid></search><sort><creationdate>20230601</creationdate><title>Surgical results of transcutaneous bone-anchored hearing aid comparing the C-shaped and linear incision techniques</title><author>Miura, Mauricio Schneider ; Ogando, Patrícia Barcelos ; Pasqualini, Marina Paese ; Neves, Hemily ; Lubianca Neto, José Faibes</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c347t-9fc467d95104db906dd708b1d4ff5edecd37026c05bba1f65420ec9cc11cd62c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Bone Conduction</topic><topic>Ear</topic><topic>Head and Neck Surgery</topic><topic>Hearing Aids - adverse effects</topic><topic>Hearing Loss, Conductive - surgery</topic><topic>Humans</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Neurosurgery</topic><topic>Otology</topic><topic>Otorhinolaryngology</topic><topic>Postoperative Complications - etiology</topic><topic>Prosthesis Implantation - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Miura, Mauricio Schneider</creatorcontrib><creatorcontrib>Ogando, Patrícia Barcelos</creatorcontrib><creatorcontrib>Pasqualini, Marina Paese</creatorcontrib><creatorcontrib>Neves, Hemily</creatorcontrib><creatorcontrib>Lubianca Neto, José Faibes</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European archives of oto-rhino-laryngology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miura, Mauricio Schneider</au><au>Ogando, Patrícia Barcelos</au><au>Pasqualini, Marina Paese</au><au>Neves, Hemily</au><au>Lubianca Neto, José Faibes</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Surgical results of transcutaneous bone-anchored hearing aid comparing the C-shaped and linear incision techniques</atitle><jtitle>European archives of oto-rhino-laryngology</jtitle><stitle>Eur Arch Otorhinolaryngol</stitle><addtitle>Eur Arch Otorhinolaryngol</addtitle><date>2023-06-01</date><risdate>2023</risdate><volume>280</volume><issue>6</issue><spage>2749</spage><epage>2754</epage><pages>2749-2754</pages><issn>0937-4477</issn><eissn>1434-4726</eissn><abstract>Purpose The aim of the study is to compare the operative time and postoperative complication outcomes for bone-anchored hearing aid (BAHA) implants using two different techniques: the C-shaped incision technique and the linear incision technique. Methods An analysis was carried out of 38 patients implanted with transcutaneous BAHAs during a 4-year period in a single otolaryngology department. Results The implantation was carried out under general anesthesia. Operative time was significant lower with the linear technique compared to the C-shaped technique (76.55 min, SD 16.75 vs. 93.17 min, SD 19.82; p  = 0.007). There was no difference in postoperative complications between the two techniques. Conclusions The use of linear incision for transcutaneous BAHA system implantation is associated with a reduced surgery time compared to the C-shaped technique, with no increase in postoperative complications.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><pmid>36625868</pmid><doi>10.1007/s00405-022-07778-w</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-1362-5072</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0937-4477
ispartof European archives of oto-rhino-laryngology, 2023-06, Vol.280 (6), p.2749-2754
issn 0937-4477
1434-4726
language eng
recordid cdi_proquest_miscellaneous_2763333126
source MEDLINE; SpringerLink Journals
subjects Bone Conduction
Ear
Head and Neck Surgery
Hearing Aids - adverse effects
Hearing Loss, Conductive - surgery
Humans
Medicine
Medicine & Public Health
Neurosurgery
Otology
Otorhinolaryngology
Postoperative Complications - etiology
Prosthesis Implantation - methods
title Surgical results of transcutaneous bone-anchored hearing aid comparing the C-shaped and linear incision techniques
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T07%3A54%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Surgical%20results%20of%20transcutaneous%20bone-anchored%20hearing%20aid%20comparing%20the%20C-shaped%20and%20linear%20incision%20techniques&rft.jtitle=European%20archives%20of%20oto-rhino-laryngology&rft.au=Miura,%20Mauricio%20Schneider&rft.date=2023-06-01&rft.volume=280&rft.issue=6&rft.spage=2749&rft.epage=2754&rft.pages=2749-2754&rft.issn=0937-4477&rft.eissn=1434-4726&rft_id=info:doi/10.1007/s00405-022-07778-w&rft_dat=%3Cproquest_cross%3E2763333126%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2763333126&rft_id=info:pmid/36625868&rfr_iscdi=true