Development of Bi-2212 Rutherford cable

An 80 meter long Rutherford cable was fabricated with 20 strands of 0.8 mm diameter Bi-2212 wire. The conductor utilized in this cable was a double stack design (7 × 61) comprising 427 filaments. The critical current (Ic) of the cable was measured at liquid helium in applied magnetic field up to 4T....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physica. C, Superconductivity Superconductivity, 2000, Vol.341, p.2539-2543
Hauptverfasser: Motowidlo, L.R., Sokolowski, R.S., Hasegawa, T., Aoki, Y., Koizumi, T., Ohtani, N., Scanlan, R., Dietderich, D., Nagaya, S.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2543
container_issue
container_start_page 2539
container_title Physica. C, Superconductivity
container_volume 341
creator Motowidlo, L.R.
Sokolowski, R.S.
Hasegawa, T.
Aoki, Y.
Koizumi, T.
Ohtani, N.
Scanlan, R.
Dietderich, D.
Nagaya, S.
description An 80 meter long Rutherford cable was fabricated with 20 strands of 0.8 mm diameter Bi-2212 wire. The conductor utilized in this cable was a double stack design (7 × 61) comprising 427 filaments. The critical current (Ic) of the cable was measured at liquid helium in applied magnetic field up to 4T. The Ic results of the cable show no degradation when normalized to the strand. The cable was sectioned into four 17-meter lengths and one 10-meter piece. These sections were heat treated and the ends cut and tested. The average Ic of all cable pieces tested was 2990 A ± 10% in self field. The bending strain of Rutherford cables with a ceramic coated Ni-alloy core showed little or no degradation up to 6%. In contrast, cables manufactured without a Ni-alloy core showed critical bending strains of about 2%.
doi_str_mv 10.1016/S0921-4534(00)01344-7
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_27494374</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0921453400013447</els_id><sourcerecordid>27494374</sourcerecordid><originalsourceid>FETCH-LOGICAL-c369t-a715ff23b19187b1123d04ca0a6ced8a8324b75f66edbc7b0e7b5e593e7e90c23</originalsourceid><addsrcrecordid>eNqNkEtLAzEUhYMoWKs_QZiVj0U0z8lkJVqfUBB8rEOSucHItKnJtOC_d2zFrd7N3XznwPkQOqTkjBJanz8TzSgWkosTQk4J5UJgtYVGtFEcMyr4Nhr9Irtor5R3MhzVdISOr2EFXVrMYN5XKVRXETNGWfW07N8gh5TbylvXwT7aCbYrcPDzx-j19uZlco-nj3cPk8sp9rzWPbaKyhAYd0N5oxyljLdEeEts7aFtbMOZcEqGuobWeeUIKCdBag4KNPGMj9HRpneR08cSSm9msXjoOjuHtCyGKaEFV-I_YKO0lgMoN6DPqZQMwSxynNn8aSgx3_7M2p_5lmMIMWt_Rg25i00OhrmrCNkUH2E-zIgZfG_aFP9o-ALNcHTi</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>27487995</pqid></control><display><type>article</type><title>Development of Bi-2212 Rutherford cable</title><source>Access via ScienceDirect (Elsevier)</source><creator>Motowidlo, L.R. ; Sokolowski, R.S. ; Hasegawa, T. ; Aoki, Y. ; Koizumi, T. ; Ohtani, N. ; Scanlan, R. ; Dietderich, D. ; Nagaya, S.</creator><creatorcontrib>Motowidlo, L.R. ; Sokolowski, R.S. ; Hasegawa, T. ; Aoki, Y. ; Koizumi, T. ; Ohtani, N. ; Scanlan, R. ; Dietderich, D. ; Nagaya, S.</creatorcontrib><description>An 80 meter long Rutherford cable was fabricated with 20 strands of 0.8 mm diameter Bi-2212 wire. The conductor utilized in this cable was a double stack design (7 × 61) comprising 427 filaments. The critical current (Ic) of the cable was measured at liquid helium in applied magnetic field up to 4T. The Ic results of the cable show no degradation when normalized to the strand. The cable was sectioned into four 17-meter lengths and one 10-meter piece. These sections were heat treated and the ends cut and tested. The average Ic of all cable pieces tested was 2990 A ± 10% in self field. The bending strain of Rutherford cables with a ceramic coated Ni-alloy core showed little or no degradation up to 6%. In contrast, cables manufactured without a Ni-alloy core showed critical bending strains of about 2%.</description><identifier>ISSN: 0921-4534</identifier><identifier>EISSN: 1873-2143</identifier><identifier>DOI: 10.1016/S0921-4534(00)01344-7</identifier><language>eng</language><publisher>Elsevier B.V</publisher><ispartof>Physica. C, Superconductivity, 2000, Vol.341, p.2539-2543</ispartof><rights>2000</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c369t-a715ff23b19187b1123d04ca0a6ced8a8324b75f66edbc7b0e7b5e593e7e90c23</citedby><cites>FETCH-LOGICAL-c369t-a715ff23b19187b1123d04ca0a6ced8a8324b75f66edbc7b0e7b5e593e7e90c23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0921-4534(00)01344-7$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,4024,27923,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Motowidlo, L.R.</creatorcontrib><creatorcontrib>Sokolowski, R.S.</creatorcontrib><creatorcontrib>Hasegawa, T.</creatorcontrib><creatorcontrib>Aoki, Y.</creatorcontrib><creatorcontrib>Koizumi, T.</creatorcontrib><creatorcontrib>Ohtani, N.</creatorcontrib><creatorcontrib>Scanlan, R.</creatorcontrib><creatorcontrib>Dietderich, D.</creatorcontrib><creatorcontrib>Nagaya, S.</creatorcontrib><title>Development of Bi-2212 Rutherford cable</title><title>Physica. C, Superconductivity</title><description>An 80 meter long Rutherford cable was fabricated with 20 strands of 0.8 mm diameter Bi-2212 wire. The conductor utilized in this cable was a double stack design (7 × 61) comprising 427 filaments. The critical current (Ic) of the cable was measured at liquid helium in applied magnetic field up to 4T. The Ic results of the cable show no degradation when normalized to the strand. The cable was sectioned into four 17-meter lengths and one 10-meter piece. These sections were heat treated and the ends cut and tested. The average Ic of all cable pieces tested was 2990 A ± 10% in self field. The bending strain of Rutherford cables with a ceramic coated Ni-alloy core showed little or no degradation up to 6%. In contrast, cables manufactured without a Ni-alloy core showed critical bending strains of about 2%.</description><issn>0921-4534</issn><issn>1873-2143</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNqNkEtLAzEUhYMoWKs_QZiVj0U0z8lkJVqfUBB8rEOSucHItKnJtOC_d2zFrd7N3XznwPkQOqTkjBJanz8TzSgWkosTQk4J5UJgtYVGtFEcMyr4Nhr9Irtor5R3MhzVdISOr2EFXVrMYN5XKVRXETNGWfW07N8gh5TbylvXwT7aCbYrcPDzx-j19uZlco-nj3cPk8sp9rzWPbaKyhAYd0N5oxyljLdEeEts7aFtbMOZcEqGuobWeeUIKCdBag4KNPGMj9HRpneR08cSSm9msXjoOjuHtCyGKaEFV-I_YKO0lgMoN6DPqZQMwSxynNn8aSgx3_7M2p_5lmMIMWt_Rg25i00OhrmrCNkUH2E-zIgZfG_aFP9o-ALNcHTi</recordid><startdate>2000</startdate><enddate>2000</enddate><creator>Motowidlo, L.R.</creator><creator>Sokolowski, R.S.</creator><creator>Hasegawa, T.</creator><creator>Aoki, Y.</creator><creator>Koizumi, T.</creator><creator>Ohtani, N.</creator><creator>Scanlan, R.</creator><creator>Dietderich, D.</creator><creator>Nagaya, S.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>7QQ</scope><scope>JG9</scope></search><sort><creationdate>2000</creationdate><title>Development of Bi-2212 Rutherford cable</title><author>Motowidlo, L.R. ; Sokolowski, R.S. ; Hasegawa, T. ; Aoki, Y. ; Koizumi, T. ; Ohtani, N. ; Scanlan, R. ; Dietderich, D. ; Nagaya, S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c369t-a715ff23b19187b1123d04ca0a6ced8a8324b75f66edbc7b0e7b5e593e7e90c23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Motowidlo, L.R.</creatorcontrib><creatorcontrib>Sokolowski, R.S.</creatorcontrib><creatorcontrib>Hasegawa, T.</creatorcontrib><creatorcontrib>Aoki, Y.</creatorcontrib><creatorcontrib>Koizumi, T.</creatorcontrib><creatorcontrib>Ohtani, N.</creatorcontrib><creatorcontrib>Scanlan, R.</creatorcontrib><creatorcontrib>Dietderich, D.</creatorcontrib><creatorcontrib>Nagaya, S.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Ceramic Abstracts</collection><collection>Materials Research Database</collection><jtitle>Physica. C, Superconductivity</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Motowidlo, L.R.</au><au>Sokolowski, R.S.</au><au>Hasegawa, T.</au><au>Aoki, Y.</au><au>Koizumi, T.</au><au>Ohtani, N.</au><au>Scanlan, R.</au><au>Dietderich, D.</au><au>Nagaya, S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of Bi-2212 Rutherford cable</atitle><jtitle>Physica. C, Superconductivity</jtitle><date>2000</date><risdate>2000</risdate><volume>341</volume><spage>2539</spage><epage>2543</epage><pages>2539-2543</pages><issn>0921-4534</issn><eissn>1873-2143</eissn><abstract>An 80 meter long Rutherford cable was fabricated with 20 strands of 0.8 mm diameter Bi-2212 wire. The conductor utilized in this cable was a double stack design (7 × 61) comprising 427 filaments. The critical current (Ic) of the cable was measured at liquid helium in applied magnetic field up to 4T. The Ic results of the cable show no degradation when normalized to the strand. The cable was sectioned into four 17-meter lengths and one 10-meter piece. These sections were heat treated and the ends cut and tested. The average Ic of all cable pieces tested was 2990 A ± 10% in self field. The bending strain of Rutherford cables with a ceramic coated Ni-alloy core showed little or no degradation up to 6%. In contrast, cables manufactured without a Ni-alloy core showed critical bending strains of about 2%.</abstract><pub>Elsevier B.V</pub><doi>10.1016/S0921-4534(00)01344-7</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0921-4534
ispartof Physica. C, Superconductivity, 2000, Vol.341, p.2539-2543
issn 0921-4534
1873-2143
language eng
recordid cdi_proquest_miscellaneous_27494374
source Access via ScienceDirect (Elsevier)
title Development of Bi-2212 Rutherford cable
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T19%3A32%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20Bi-2212%20Rutherford%20cable&rft.jtitle=Physica.%20C,%20Superconductivity&rft.au=Motowidlo,%20L.R.&rft.date=2000&rft.volume=341&rft.spage=2539&rft.epage=2543&rft.pages=2539-2543&rft.issn=0921-4534&rft.eissn=1873-2143&rft_id=info:doi/10.1016/S0921-4534(00)01344-7&rft_dat=%3Cproquest_cross%3E27494374%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=27487995&rft_id=info:pmid/&rft_els_id=S0921453400013447&rfr_iscdi=true