Normalization of the electromyography amplitude during a multiple-set resistance training protocol: Reliability and differences between approaches
The first aim was to investigate the impact of different electromyography (EMG) parameters as a reference to normalize the EMG amplitude of the superficial quadriceps femoris muscles across different sets of a knee extension exercise. The second aim is to examine the reliability between days of the...
Gespeichert in:
Veröffentlicht in: | Journal of electromyography and kinesiology 2023-02, Vol.68, p.102724-102724, Article 102724 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 102724 |
---|---|
container_issue | |
container_start_page | 102724 |
container_title | Journal of electromyography and kinesiology |
container_volume | 68 |
creator | Lanza, Marcel B. Lacerda, Lucas T. Gurgel Simões, Marina Martins-Costa, Hugo C. Diniz, Rodrigo C. Chagas, Mauro H. Lima, Fernando V. |
description | The first aim was to investigate the impact of different electromyography (EMG) parameters as a reference to normalize the EMG amplitude of the superficial quadriceps femoris muscles across different sets of a knee extension exercise. The second aim is to examine the reliability between days of the EMG parameters used as a reference. Eleven young males attended the laboratory on 4 different days and performed one repetition maximum test, maximumvoluntary isometric contractions, and a resistance training protocol until failure. Surface EMG was placed over the rectus femoris, vastus lateralis, and vastus medialis muscles. Seven EMG parameters were calculated from the tasks and used to normalize EMG amplitude measured during the resistance training protocol. A repeated-measures two-way ANOVA was used (normalized EMG amplitude × set) to compare normalized EMG across sets, while an intraclass correlation coefficient, coefficient of variation, and Bland-Altman plots were used to calculate the intra-day reliability of the EMG parameters. The present investigation showed that normalized EMG amplitude of the superficial muscles of the quadriceps measured during a knee extension exercise is influenced by the EMG parameter and depends on the muscle. While rectus femoris and vastus lateralis normalized EMG amplitude presented one parameter among seven showing similar value to the other parameters, VM showed two. Lastly, all EMG parameters for all muscles presented an overall excellent reliability and agreement between days. |
doi_str_mv | 10.1016/j.jelekin.2022.102724 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2738193403</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1050641122000979</els_id><sourcerecordid>2738193403</sourcerecordid><originalsourceid>FETCH-LOGICAL-c295t-40cdd4707fe9b1fd997cfee02b1d4132a39c53dd765e7cf662208548fd189fa43</originalsourceid><addsrcrecordid>eNqFkcuO1DAQRS0EYh7wCSAv2aTxI4ljNgiNYEAaMRKCteXY5Wk3ThxsB9TzGXwxbnUz21mVVT51r6ouQq8o2VBC-7e7zQ4C_PTzhhHGao8J1j5B53QQvOkEpU_rm3Sk6VtKz9BFzjtCqCADeY7OeM-llLQ7R3-_xjTp4O918XHG0eGyBVyVTUlx2se7pJftHutpCb6sFrBdk5_vsMbTGopfAjQZCk6QfS56NoBL0n4-IEuKJZoY3uFvELwefVWoSrPF1jsHCSqd8QjlD8CM9VJ5bbaQX6BnTocML0_1Ev349PH71efm5vb6y9WHm8Yw2ZWmJcbaVhDhQI7UWSmFcQCEjdS2lDPNpem4taLvoP70PWNk6NrBWTpIp1t-id4cdavxrxVyUZPPBkLQM8Q1Kyb4QCVvCa9od0RNijkncGpJftJpryhRhzjUTp3iUIc41DGOOvf6ZLGOE9iHqf_3r8D7IwB10d8eksrGHw5jfaoRKBv9Ixb_ADX1otE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2738193403</pqid></control><display><type>article</type><title>Normalization of the electromyography amplitude during a multiple-set resistance training protocol: Reliability and differences between approaches</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Lanza, Marcel B. ; Lacerda, Lucas T. ; Gurgel Simões, Marina ; Martins-Costa, Hugo C. ; Diniz, Rodrigo C. ; Chagas, Mauro H. ; Lima, Fernando V.</creator><creatorcontrib>Lanza, Marcel B. ; Lacerda, Lucas T. ; Gurgel Simões, Marina ; Martins-Costa, Hugo C. ; Diniz, Rodrigo C. ; Chagas, Mauro H. ; Lima, Fernando V.</creatorcontrib><description>The first aim was to investigate the impact of different electromyography (EMG) parameters as a reference to normalize the EMG amplitude of the superficial quadriceps femoris muscles across different sets of a knee extension exercise. The second aim is to examine the reliability between days of the EMG parameters used as a reference. Eleven young males attended the laboratory on 4 different days and performed one repetition maximum test, maximumvoluntary isometric contractions, and a resistance training protocol until failure. Surface EMG was placed over the rectus femoris, vastus lateralis, and vastus medialis muscles. Seven EMG parameters were calculated from the tasks and used to normalize EMG amplitude measured during the resistance training protocol. A repeated-measures two-way ANOVA was used (normalized EMG amplitude × set) to compare normalized EMG across sets, while an intraclass correlation coefficient, coefficient of variation, and Bland-Altman plots were used to calculate the intra-day reliability of the EMG parameters. The present investigation showed that normalized EMG amplitude of the superficial muscles of the quadriceps measured during a knee extension exercise is influenced by the EMG parameter and depends on the muscle. While rectus femoris and vastus lateralis normalized EMG amplitude presented one parameter among seven showing similar value to the other parameters, VM showed two. Lastly, all EMG parameters for all muscles presented an overall excellent reliability and agreement between days.</description><identifier>ISSN: 1050-6411</identifier><identifier>EISSN: 1873-5711</identifier><identifier>DOI: 10.1016/j.jelekin.2022.102724</identifier><identifier>PMID: 36399915</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Electromyography - methods ; EMG amplitude ; EMG normalization ; Humans ; Knee extension ; Male ; Muscle, Skeletal - physiology ; Quadriceps Muscle - physiology ; Reliability ; Reproducibility of Results ; Resistance Training</subject><ispartof>Journal of electromyography and kinesiology, 2023-02, Vol.68, p.102724-102724, Article 102724</ispartof><rights>2022 Elsevier Ltd</rights><rights>Copyright © 2022 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c295t-40cdd4707fe9b1fd997cfee02b1d4132a39c53dd765e7cf662208548fd189fa43</citedby><cites>FETCH-LOGICAL-c295t-40cdd4707fe9b1fd997cfee02b1d4132a39c53dd765e7cf662208548fd189fa43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jelekin.2022.102724$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36399915$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lanza, Marcel B.</creatorcontrib><creatorcontrib>Lacerda, Lucas T.</creatorcontrib><creatorcontrib>Gurgel Simões, Marina</creatorcontrib><creatorcontrib>Martins-Costa, Hugo C.</creatorcontrib><creatorcontrib>Diniz, Rodrigo C.</creatorcontrib><creatorcontrib>Chagas, Mauro H.</creatorcontrib><creatorcontrib>Lima, Fernando V.</creatorcontrib><title>Normalization of the electromyography amplitude during a multiple-set resistance training protocol: Reliability and differences between approaches</title><title>Journal of electromyography and kinesiology</title><addtitle>J Electromyogr Kinesiol</addtitle><description>The first aim was to investigate the impact of different electromyography (EMG) parameters as a reference to normalize the EMG amplitude of the superficial quadriceps femoris muscles across different sets of a knee extension exercise. The second aim is to examine the reliability between days of the EMG parameters used as a reference. Eleven young males attended the laboratory on 4 different days and performed one repetition maximum test, maximumvoluntary isometric contractions, and a resistance training protocol until failure. Surface EMG was placed over the rectus femoris, vastus lateralis, and vastus medialis muscles. Seven EMG parameters were calculated from the tasks and used to normalize EMG amplitude measured during the resistance training protocol. A repeated-measures two-way ANOVA was used (normalized EMG amplitude × set) to compare normalized EMG across sets, while an intraclass correlation coefficient, coefficient of variation, and Bland-Altman plots were used to calculate the intra-day reliability of the EMG parameters. The present investigation showed that normalized EMG amplitude of the superficial muscles of the quadriceps measured during a knee extension exercise is influenced by the EMG parameter and depends on the muscle. While rectus femoris and vastus lateralis normalized EMG amplitude presented one parameter among seven showing similar value to the other parameters, VM showed two. Lastly, all EMG parameters for all muscles presented an overall excellent reliability and agreement between days.</description><subject>Electromyography - methods</subject><subject>EMG amplitude</subject><subject>EMG normalization</subject><subject>Humans</subject><subject>Knee extension</subject><subject>Male</subject><subject>Muscle, Skeletal - physiology</subject><subject>Quadriceps Muscle - physiology</subject><subject>Reliability</subject><subject>Reproducibility of Results</subject><subject>Resistance Training</subject><issn>1050-6411</issn><issn>1873-5711</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkcuO1DAQRS0EYh7wCSAv2aTxI4ljNgiNYEAaMRKCteXY5Wk3ThxsB9TzGXwxbnUz21mVVT51r6ouQq8o2VBC-7e7zQ4C_PTzhhHGao8J1j5B53QQvOkEpU_rm3Sk6VtKz9BFzjtCqCADeY7OeM-llLQ7R3-_xjTp4O918XHG0eGyBVyVTUlx2se7pJftHutpCb6sFrBdk5_vsMbTGopfAjQZCk6QfS56NoBL0n4-IEuKJZoY3uFvELwefVWoSrPF1jsHCSqd8QjlD8CM9VJ5bbaQX6BnTocML0_1Ev349PH71efm5vb6y9WHm8Yw2ZWmJcbaVhDhQI7UWSmFcQCEjdS2lDPNpem4taLvoP70PWNk6NrBWTpIp1t-id4cdavxrxVyUZPPBkLQM8Q1Kyb4QCVvCa9od0RNijkncGpJftJpryhRhzjUTp3iUIc41DGOOvf6ZLGOE9iHqf_3r8D7IwB10d8eksrGHw5jfaoRKBv9Ixb_ADX1otE</recordid><startdate>202302</startdate><enddate>202302</enddate><creator>Lanza, Marcel B.</creator><creator>Lacerda, Lucas T.</creator><creator>Gurgel Simões, Marina</creator><creator>Martins-Costa, Hugo C.</creator><creator>Diniz, Rodrigo C.</creator><creator>Chagas, Mauro H.</creator><creator>Lima, Fernando V.</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202302</creationdate><title>Normalization of the electromyography amplitude during a multiple-set resistance training protocol: Reliability and differences between approaches</title><author>Lanza, Marcel B. ; Lacerda, Lucas T. ; Gurgel Simões, Marina ; Martins-Costa, Hugo C. ; Diniz, Rodrigo C. ; Chagas, Mauro H. ; Lima, Fernando V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c295t-40cdd4707fe9b1fd997cfee02b1d4132a39c53dd765e7cf662208548fd189fa43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Electromyography - methods</topic><topic>EMG amplitude</topic><topic>EMG normalization</topic><topic>Humans</topic><topic>Knee extension</topic><topic>Male</topic><topic>Muscle, Skeletal - physiology</topic><topic>Quadriceps Muscle - physiology</topic><topic>Reliability</topic><topic>Reproducibility of Results</topic><topic>Resistance Training</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lanza, Marcel B.</creatorcontrib><creatorcontrib>Lacerda, Lucas T.</creatorcontrib><creatorcontrib>Gurgel Simões, Marina</creatorcontrib><creatorcontrib>Martins-Costa, Hugo C.</creatorcontrib><creatorcontrib>Diniz, Rodrigo C.</creatorcontrib><creatorcontrib>Chagas, Mauro H.</creatorcontrib><creatorcontrib>Lima, Fernando V.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of electromyography and kinesiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lanza, Marcel B.</au><au>Lacerda, Lucas T.</au><au>Gurgel Simões, Marina</au><au>Martins-Costa, Hugo C.</au><au>Diniz, Rodrigo C.</au><au>Chagas, Mauro H.</au><au>Lima, Fernando V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Normalization of the electromyography amplitude during a multiple-set resistance training protocol: Reliability and differences between approaches</atitle><jtitle>Journal of electromyography and kinesiology</jtitle><addtitle>J Electromyogr Kinesiol</addtitle><date>2023-02</date><risdate>2023</risdate><volume>68</volume><spage>102724</spage><epage>102724</epage><pages>102724-102724</pages><artnum>102724</artnum><issn>1050-6411</issn><eissn>1873-5711</eissn><abstract>The first aim was to investigate the impact of different electromyography (EMG) parameters as a reference to normalize the EMG amplitude of the superficial quadriceps femoris muscles across different sets of a knee extension exercise. The second aim is to examine the reliability between days of the EMG parameters used as a reference. Eleven young males attended the laboratory on 4 different days and performed one repetition maximum test, maximumvoluntary isometric contractions, and a resistance training protocol until failure. Surface EMG was placed over the rectus femoris, vastus lateralis, and vastus medialis muscles. Seven EMG parameters were calculated from the tasks and used to normalize EMG amplitude measured during the resistance training protocol. A repeated-measures two-way ANOVA was used (normalized EMG amplitude × set) to compare normalized EMG across sets, while an intraclass correlation coefficient, coefficient of variation, and Bland-Altman plots were used to calculate the intra-day reliability of the EMG parameters. The present investigation showed that normalized EMG amplitude of the superficial muscles of the quadriceps measured during a knee extension exercise is influenced by the EMG parameter and depends on the muscle. While rectus femoris and vastus lateralis normalized EMG amplitude presented one parameter among seven showing similar value to the other parameters, VM showed two. Lastly, all EMG parameters for all muscles presented an overall excellent reliability and agreement between days.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>36399915</pmid><doi>10.1016/j.jelekin.2022.102724</doi><tpages>1</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1050-6411 |
ispartof | Journal of electromyography and kinesiology, 2023-02, Vol.68, p.102724-102724, Article 102724 |
issn | 1050-6411 1873-5711 |
language | eng |
recordid | cdi_proquest_miscellaneous_2738193403 |
source | MEDLINE; Access via ScienceDirect (Elsevier) |
subjects | Electromyography - methods EMG amplitude EMG normalization Humans Knee extension Male Muscle, Skeletal - physiology Quadriceps Muscle - physiology Reliability Reproducibility of Results Resistance Training |
title | Normalization of the electromyography amplitude during a multiple-set resistance training protocol: Reliability and differences between approaches |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T09%3A32%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Normalization%20of%20the%20electromyography%20amplitude%20during%20a%20multiple-set%20resistance%20training%20protocol:%20Reliability%20and%20differences%20between%20approaches&rft.jtitle=Journal%20of%20electromyography%20and%20kinesiology&rft.au=Lanza,%20Marcel%20B.&rft.date=2023-02&rft.volume=68&rft.spage=102724&rft.epage=102724&rft.pages=102724-102724&rft.artnum=102724&rft.issn=1050-6411&rft.eissn=1873-5711&rft_id=info:doi/10.1016/j.jelekin.2022.102724&rft_dat=%3Cproquest_cross%3E2738193403%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2738193403&rft_id=info:pmid/36399915&rft_els_id=S1050641122000979&rfr_iscdi=true |