Comparative film thickness determination by atomic force microscopy and ellipsometry for ultrathin polymer films
Ellipsometry and atomic force microscopy (AFM) were used to study the film thickness of continuous and discontinuous polymer films in the 1–20 nm thickness range on smooth silicon wafers and on structured aluminium substrates. The methods of exploiting AFM for thickness measurements with a high spat...
Gespeichert in:
Veröffentlicht in: | Surface and interface analysis 1995-11, Vol.23 (12), p.797-808 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 808 |
---|---|
container_issue | 12 |
container_start_page | 797 |
container_title | Surface and interface analysis |
container_volume | 23 |
creator | Gesang, T. Fanter, D. Höper, R. Possart, W. Hennemann, O.-D. |
description | Ellipsometry and atomic force microscopy (AFM) were used to study the film thickness of continuous and discontinuous polymer films in the 1–20 nm thickness range on smooth silicon wafers and on structured aluminium substrates. The methods of exploiting AFM for thickness measurements with a high spatial resolution are described.
For continuous films, the AFM method is a direct one, i.e. it does not rely on any model. There is excellent agreement between AFM and ellipsometry in the 1–10 nm thickness range. Very small systematic deviations occur in this range but big deviations occur above 10 nm, and are discussed. The film preparation method, spin coating, was characterized to result in prepolymer films with a very homogeneous thickness.
Discontinuous films of 2–9 nm thick were also evaluated by both methods of thickness determination. In this case, for one of the AFM approaches a model has to be used too. The agreement between both methods ranged from very good to poor, depending on the kind of sample and on the kind of AFM determination method. |
doi_str_mv | 10.1002/sia.740231202 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_27330775</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>27330775</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3812-e2aa7e908f30006c92b957e41f61524bb678b5ae981373a21eb5259f535c5b63</originalsourceid><addsrcrecordid>eNp9kUtPxCAUhYnRxPGxdM_CuKvyKKUszURHjY-FJho3hOJtRNtSoaP238s4k4krV9zAud89nIvQASXHlBB2Ep05ljlhnDLCNtCEElVkStFyE00IzVnGcka30U6Mb4SQkpfFBPVT3_YmmMF9Aq5d0-Lh1dn3DmLELzBAaF2XHn2HqxGbwbfO4toHCzhVwUfr-3TfvWBoGtdH38IQxoUCz5shYV9dh3vfjC2EX3zcQ1u1aSLsr85d9HB-9jC9yK7vZpfT0-vM8pKyDJgxEhQpa568FlaxSgkJOa0LKlheVYUsK2FAlZRLbhiFSjChasGFFVXBd9HREtsH_zGHOOjWRZtMmg78PGomOSdSiiTMlsLFb2KAWvfBtSaMmhK9iFWnWPU61qQ_XIFNtKapg-msi-smpkguyGK-XMq-XAPj_0x9f3n6d8DKkIsDfK87TXjXheRS6Mfbmb66Sft8fko0_gN5CJjl</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>27330775</pqid></control><display><type>article</type><title>Comparative film thickness determination by atomic force microscopy and ellipsometry for ultrathin polymer films</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Gesang, T. ; Fanter, D. ; Höper, R. ; Possart, W. ; Hennemann, O.-D.</creator><creatorcontrib>Gesang, T. ; Fanter, D. ; Höper, R. ; Possart, W. ; Hennemann, O.-D.</creatorcontrib><description>Ellipsometry and atomic force microscopy (AFM) were used to study the film thickness of continuous and discontinuous polymer films in the 1–20 nm thickness range on smooth silicon wafers and on structured aluminium substrates. The methods of exploiting AFM for thickness measurements with a high spatial resolution are described.
For continuous films, the AFM method is a direct one, i.e. it does not rely on any model. There is excellent agreement between AFM and ellipsometry in the 1–10 nm thickness range. Very small systematic deviations occur in this range but big deviations occur above 10 nm, and are discussed. The film preparation method, spin coating, was characterized to result in prepolymer films with a very homogeneous thickness.
Discontinuous films of 2–9 nm thick were also evaluated by both methods of thickness determination. In this case, for one of the AFM approaches a model has to be used too. The agreement between both methods ranged from very good to poor, depending on the kind of sample and on the kind of AFM determination method.</description><identifier>ISSN: 0142-2421</identifier><identifier>EISSN: 1096-9918</identifier><identifier>DOI: 10.1002/sia.740231202</identifier><identifier>CODEN: SIANDQ</identifier><language>eng</language><publisher>Sussex: John Wiley & Sons Ltd</publisher><subject>Applied sciences ; Exact sciences and technology ; Forms of application and semi-finished materials ; Polymer industry, paints, wood ; Sheets and films ; Technology of polymers</subject><ispartof>Surface and interface analysis, 1995-11, Vol.23 (12), p.797-808</ispartof><rights>Copyright © 1995 John Wiley & Sons Ltd.</rights><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3812-e2aa7e908f30006c92b957e41f61524bb678b5ae981373a21eb5259f535c5b63</citedby><cites>FETCH-LOGICAL-c3812-e2aa7e908f30006c92b957e41f61524bb678b5ae981373a21eb5259f535c5b63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fsia.740231202$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fsia.740231202$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=2904506$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Gesang, T.</creatorcontrib><creatorcontrib>Fanter, D.</creatorcontrib><creatorcontrib>Höper, R.</creatorcontrib><creatorcontrib>Possart, W.</creatorcontrib><creatorcontrib>Hennemann, O.-D.</creatorcontrib><title>Comparative film thickness determination by atomic force microscopy and ellipsometry for ultrathin polymer films</title><title>Surface and interface analysis</title><addtitle>Surf. Interface Anal</addtitle><description>Ellipsometry and atomic force microscopy (AFM) were used to study the film thickness of continuous and discontinuous polymer films in the 1–20 nm thickness range on smooth silicon wafers and on structured aluminium substrates. The methods of exploiting AFM for thickness measurements with a high spatial resolution are described.
For continuous films, the AFM method is a direct one, i.e. it does not rely on any model. There is excellent agreement between AFM and ellipsometry in the 1–10 nm thickness range. Very small systematic deviations occur in this range but big deviations occur above 10 nm, and are discussed. The film preparation method, spin coating, was characterized to result in prepolymer films with a very homogeneous thickness.
Discontinuous films of 2–9 nm thick were also evaluated by both methods of thickness determination. In this case, for one of the AFM approaches a model has to be used too. The agreement between both methods ranged from very good to poor, depending on the kind of sample and on the kind of AFM determination method.</description><subject>Applied sciences</subject><subject>Exact sciences and technology</subject><subject>Forms of application and semi-finished materials</subject><subject>Polymer industry, paints, wood</subject><subject>Sheets and films</subject><subject>Technology of polymers</subject><issn>0142-2421</issn><issn>1096-9918</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNp9kUtPxCAUhYnRxPGxdM_CuKvyKKUszURHjY-FJho3hOJtRNtSoaP238s4k4krV9zAud89nIvQASXHlBB2Ep05ljlhnDLCNtCEElVkStFyE00IzVnGcka30U6Mb4SQkpfFBPVT3_YmmMF9Aq5d0-Lh1dn3DmLELzBAaF2XHn2HqxGbwbfO4toHCzhVwUfr-3TfvWBoGtdH38IQxoUCz5shYV9dh3vfjC2EX3zcQ1u1aSLsr85d9HB-9jC9yK7vZpfT0-vM8pKyDJgxEhQpa568FlaxSgkJOa0LKlheVYUsK2FAlZRLbhiFSjChasGFFVXBd9HREtsH_zGHOOjWRZtMmg78PGomOSdSiiTMlsLFb2KAWvfBtSaMmhK9iFWnWPU61qQ_XIFNtKapg-msi-smpkguyGK-XMq-XAPj_0x9f3n6d8DKkIsDfK87TXjXheRS6Mfbmb66Sft8fko0_gN5CJjl</recordid><startdate>199511</startdate><enddate>199511</enddate><creator>Gesang, T.</creator><creator>Fanter, D.</creator><creator>Höper, R.</creator><creator>Possart, W.</creator><creator>Hennemann, O.-D.</creator><general>John Wiley & Sons Ltd</general><general>Wiley</general><scope>BSCLL</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>199511</creationdate><title>Comparative film thickness determination by atomic force microscopy and ellipsometry for ultrathin polymer films</title><author>Gesang, T. ; Fanter, D. ; Höper, R. ; Possart, W. ; Hennemann, O.-D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3812-e2aa7e908f30006c92b957e41f61524bb678b5ae981373a21eb5259f535c5b63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Applied sciences</topic><topic>Exact sciences and technology</topic><topic>Forms of application and semi-finished materials</topic><topic>Polymer industry, paints, wood</topic><topic>Sheets and films</topic><topic>Technology of polymers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gesang, T.</creatorcontrib><creatorcontrib>Fanter, D.</creatorcontrib><creatorcontrib>Höper, R.</creatorcontrib><creatorcontrib>Possart, W.</creatorcontrib><creatorcontrib>Hennemann, O.-D.</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Surface and interface analysis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gesang, T.</au><au>Fanter, D.</au><au>Höper, R.</au><au>Possart, W.</au><au>Hennemann, O.-D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative film thickness determination by atomic force microscopy and ellipsometry for ultrathin polymer films</atitle><jtitle>Surface and interface analysis</jtitle><addtitle>Surf. Interface Anal</addtitle><date>1995-11</date><risdate>1995</risdate><volume>23</volume><issue>12</issue><spage>797</spage><epage>808</epage><pages>797-808</pages><issn>0142-2421</issn><eissn>1096-9918</eissn><coden>SIANDQ</coden><abstract>Ellipsometry and atomic force microscopy (AFM) were used to study the film thickness of continuous and discontinuous polymer films in the 1–20 nm thickness range on smooth silicon wafers and on structured aluminium substrates. The methods of exploiting AFM for thickness measurements with a high spatial resolution are described.
For continuous films, the AFM method is a direct one, i.e. it does not rely on any model. There is excellent agreement between AFM and ellipsometry in the 1–10 nm thickness range. Very small systematic deviations occur in this range but big deviations occur above 10 nm, and are discussed. The film preparation method, spin coating, was characterized to result in prepolymer films with a very homogeneous thickness.
Discontinuous films of 2–9 nm thick were also evaluated by both methods of thickness determination. In this case, for one of the AFM approaches a model has to be used too. The agreement between both methods ranged from very good to poor, depending on the kind of sample and on the kind of AFM determination method.</abstract><cop>Sussex</cop><pub>John Wiley & Sons Ltd</pub><doi>10.1002/sia.740231202</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0142-2421 |
ispartof | Surface and interface analysis, 1995-11, Vol.23 (12), p.797-808 |
issn | 0142-2421 1096-9918 |
language | eng |
recordid | cdi_proquest_miscellaneous_27330775 |
source | Wiley Online Library Journals Frontfile Complete |
subjects | Applied sciences Exact sciences and technology Forms of application and semi-finished materials Polymer industry, paints, wood Sheets and films Technology of polymers |
title | Comparative film thickness determination by atomic force microscopy and ellipsometry for ultrathin polymer films |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-15T09%3A49%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20film%20thickness%20determination%20by%20atomic%20force%20microscopy%20and%20ellipsometry%20for%20ultrathin%20polymer%20films&rft.jtitle=Surface%20and%20interface%20analysis&rft.au=Gesang,%20T.&rft.date=1995-11&rft.volume=23&rft.issue=12&rft.spage=797&rft.epage=808&rft.pages=797-808&rft.issn=0142-2421&rft.eissn=1096-9918&rft.coden=SIANDQ&rft_id=info:doi/10.1002/sia.740231202&rft_dat=%3Cproquest_cross%3E27330775%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=27330775&rft_id=info:pmid/&rfr_iscdi=true |