First Carpometacarpal Joint Motion and Proximal Migration of the First Metacarpal After Tensioning of a Suture Device Suspensionplasty Compared With Trapeziectomy: A Biomechanical Cadaver Study

PURPOSEThe purpose of this cadaveric biomechanical experiment was to evaluate the effects of suture button suspensionplasty of the first carpometacarpal joint on thumb biomechanics and thumb position compared with an intact, arthritic specimen.METHODSSix tendons in 8 cadaver hands were loaded to sim...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of hand surgery (American ed.) 2023-11, Vol.48 (11), p.1164-1164.e8
Hauptverfasser: Albanese, Matthew A., Werner, Frederick W., Travers, Paul M., Short, Walter H.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1164.e8
container_issue 11
container_start_page 1164
container_title The Journal of hand surgery (American ed.)
container_volume 48
creator Albanese, Matthew A.
Werner, Frederick W.
Travers, Paul M.
Short, Walter H.
description PURPOSEThe purpose of this cadaveric biomechanical experiment was to evaluate the effects of suture button suspensionplasty of the first carpometacarpal joint on thumb biomechanics and thumb position compared with an intact, arthritic specimen.METHODSSix tendons in 8 cadaver hands were loaded to simulate 6 activities of daily living and passively moved through a circumduction motion. Proximal migration of the base of the first metacarpal was measured using optical motion sensors in the intact hand, after trapeziectomy, and following insertion of a suture button suspensionplasty with nominal tightening (approximately 4.5 N) and with firm tightening (approximately 44.5 N).RESULTSRemoval of the trapezium caused a significant increase in the proximal migration of the first metacarpal during a simulated jar grasp, opposition, flexion, extension, and abduction (average, 9.5 mm) compared with its location with the thumb in the intact, neutral position (average, 3.8 mm). Firm tightening of the tightrope caused a near elimination of the proximal migration of the first metacarpal (average, 0.7 mm). In all 6 static loading cases with the trapezium removed, firm tightening caused a significantly smaller migration than in the absence of tightening.CONCLUSIONSThis biomechanical cadaver study supports the hypothesis that trapeziectomy results in proximal migration of the first metacarpal. Suture suspensionplasty mitigates against this migration while maintaining normal motion of the first metacarpal compared with the intact state. Firm tightening of the suture does not adversely affect the first metacarpal's mobility and further decreases proximal migration. However, firm tightening may cause impingement between the first and second metacarpals.CLINICAL RELEVANCESuture button suspensionplasty can be used in addition to trapeziectomy in the treatment of basal joint arthritis, and may diminish the need for ligament reconstruction or temporary K-wire insertion.
doi_str_mv 10.1016/j.jhsa.2022.05.001
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2732541956</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2732541956</sourcerecordid><originalsourceid>FETCH-LOGICAL-c231t-3cd72418d7cea4933b5c952c9efef4ccc5cac5190cdddab4c011a67cc0ee66c3</originalsourceid><addsrcrecordid>eNpFkUtv1DAQxy1EJZbSL8DJRy4JfsRZwm0JlIe6aqWuxNGaTiZdr5I42E7F8u34ZnhZJE7z-s1D82fstRSlFLJ-eygP-wilEkqVwpRCyGdsJY2WRW3q6jlbCV3rwgilX7CXMR5EJmptVuz3tQsx8RbC7EdKgNmBgX_zbkp865PzE4ep43fB_3RjrmzdY4C_ad_ztCd-HrD937vpEwW-oylmyk2PJxD4_ZKWQPwjPTmkHMX5DMwDxHTkrR9nCNTx7y7t-S7ATL8cYfLj8T3f8A8uX4d7mBzmDS108JR33KelO75iFz0Mka7-2Uu2u_60a78UN7efv7abmwKVlqnQ2K1VJd91aySoGq0fDDZGYUM99RUiGgQ0shHYdR08VCikhHqNKIjqGvUle3MeOwf_Y6GY7Ogi0jDARH6JVq21MpVsTJ1RdUYx-BgD9XYO-XfhaKWwJ7nswZ7ksie5rDA2i6H_AAsfj78</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2732541956</pqid></control><display><type>article</type><title>First Carpometacarpal Joint Motion and Proximal Migration of the First Metacarpal After Tensioning of a Suture Device Suspensionplasty Compared With Trapeziectomy: A Biomechanical Cadaver Study</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Albanese, Matthew A. ; Werner, Frederick W. ; Travers, Paul M. ; Short, Walter H.</creator><creatorcontrib>Albanese, Matthew A. ; Werner, Frederick W. ; Travers, Paul M. ; Short, Walter H.</creatorcontrib><description>PURPOSEThe purpose of this cadaveric biomechanical experiment was to evaluate the effects of suture button suspensionplasty of the first carpometacarpal joint on thumb biomechanics and thumb position compared with an intact, arthritic specimen.METHODSSix tendons in 8 cadaver hands were loaded to simulate 6 activities of daily living and passively moved through a circumduction motion. Proximal migration of the base of the first metacarpal was measured using optical motion sensors in the intact hand, after trapeziectomy, and following insertion of a suture button suspensionplasty with nominal tightening (approximately 4.5 N) and with firm tightening (approximately 44.5 N).RESULTSRemoval of the trapezium caused a significant increase in the proximal migration of the first metacarpal during a simulated jar grasp, opposition, flexion, extension, and abduction (average, 9.5 mm) compared with its location with the thumb in the intact, neutral position (average, 3.8 mm). Firm tightening of the tightrope caused a near elimination of the proximal migration of the first metacarpal (average, 0.7 mm). In all 6 static loading cases with the trapezium removed, firm tightening caused a significantly smaller migration than in the absence of tightening.CONCLUSIONSThis biomechanical cadaver study supports the hypothesis that trapeziectomy results in proximal migration of the first metacarpal. Suture suspensionplasty mitigates against this migration while maintaining normal motion of the first metacarpal compared with the intact state. Firm tightening of the suture does not adversely affect the first metacarpal's mobility and further decreases proximal migration. However, firm tightening may cause impingement between the first and second metacarpals.CLINICAL RELEVANCESuture button suspensionplasty can be used in addition to trapeziectomy in the treatment of basal joint arthritis, and may diminish the need for ligament reconstruction or temporary K-wire insertion.</description><identifier>ISSN: 0363-5023</identifier><identifier>EISSN: 1531-6564</identifier><identifier>DOI: 10.1016/j.jhsa.2022.05.001</identifier><language>eng</language><ispartof>The Journal of hand surgery (American ed.), 2023-11, Vol.48 (11), p.1164-1164.e8</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c231t-3cd72418d7cea4933b5c952c9efef4ccc5cac5190cdddab4c011a67cc0ee66c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Albanese, Matthew A.</creatorcontrib><creatorcontrib>Werner, Frederick W.</creatorcontrib><creatorcontrib>Travers, Paul M.</creatorcontrib><creatorcontrib>Short, Walter H.</creatorcontrib><title>First Carpometacarpal Joint Motion and Proximal Migration of the First Metacarpal After Tensioning of a Suture Device Suspensionplasty Compared With Trapeziectomy: A Biomechanical Cadaver Study</title><title>The Journal of hand surgery (American ed.)</title><description>PURPOSEThe purpose of this cadaveric biomechanical experiment was to evaluate the effects of suture button suspensionplasty of the first carpometacarpal joint on thumb biomechanics and thumb position compared with an intact, arthritic specimen.METHODSSix tendons in 8 cadaver hands were loaded to simulate 6 activities of daily living and passively moved through a circumduction motion. Proximal migration of the base of the first metacarpal was measured using optical motion sensors in the intact hand, after trapeziectomy, and following insertion of a suture button suspensionplasty with nominal tightening (approximately 4.5 N) and with firm tightening (approximately 44.5 N).RESULTSRemoval of the trapezium caused a significant increase in the proximal migration of the first metacarpal during a simulated jar grasp, opposition, flexion, extension, and abduction (average, 9.5 mm) compared with its location with the thumb in the intact, neutral position (average, 3.8 mm). Firm tightening of the tightrope caused a near elimination of the proximal migration of the first metacarpal (average, 0.7 mm). In all 6 static loading cases with the trapezium removed, firm tightening caused a significantly smaller migration than in the absence of tightening.CONCLUSIONSThis biomechanical cadaver study supports the hypothesis that trapeziectomy results in proximal migration of the first metacarpal. Suture suspensionplasty mitigates against this migration while maintaining normal motion of the first metacarpal compared with the intact state. Firm tightening of the suture does not adversely affect the first metacarpal's mobility and further decreases proximal migration. However, firm tightening may cause impingement between the first and second metacarpals.CLINICAL RELEVANCESuture button suspensionplasty can be used in addition to trapeziectomy in the treatment of basal joint arthritis, and may diminish the need for ligament reconstruction or temporary K-wire insertion.</description><issn>0363-5023</issn><issn>1531-6564</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNpFkUtv1DAQxy1EJZbSL8DJRy4JfsRZwm0JlIe6aqWuxNGaTiZdr5I42E7F8u34ZnhZJE7z-s1D82fstRSlFLJ-eygP-wilEkqVwpRCyGdsJY2WRW3q6jlbCV3rwgilX7CXMR5EJmptVuz3tQsx8RbC7EdKgNmBgX_zbkp865PzE4ep43fB_3RjrmzdY4C_ad_ztCd-HrD937vpEwW-oylmyk2PJxD4_ZKWQPwjPTmkHMX5DMwDxHTkrR9nCNTx7y7t-S7ATL8cYfLj8T3f8A8uX4d7mBzmDS108JR33KelO75iFz0Mka7-2Uu2u_60a78UN7efv7abmwKVlqnQ2K1VJd91aySoGq0fDDZGYUM99RUiGgQ0shHYdR08VCikhHqNKIjqGvUle3MeOwf_Y6GY7Ogi0jDARH6JVq21MpVsTJ1RdUYx-BgD9XYO-XfhaKWwJ7nswZ7ksie5rDA2i6H_AAsfj78</recordid><startdate>202311</startdate><enddate>202311</enddate><creator>Albanese, Matthew A.</creator><creator>Werner, Frederick W.</creator><creator>Travers, Paul M.</creator><creator>Short, Walter H.</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202311</creationdate><title>First Carpometacarpal Joint Motion and Proximal Migration of the First Metacarpal After Tensioning of a Suture Device Suspensionplasty Compared With Trapeziectomy: A Biomechanical Cadaver Study</title><author>Albanese, Matthew A. ; Werner, Frederick W. ; Travers, Paul M. ; Short, Walter H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c231t-3cd72418d7cea4933b5c952c9efef4ccc5cac5190cdddab4c011a67cc0ee66c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Albanese, Matthew A.</creatorcontrib><creatorcontrib>Werner, Frederick W.</creatorcontrib><creatorcontrib>Travers, Paul M.</creatorcontrib><creatorcontrib>Short, Walter H.</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of hand surgery (American ed.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Albanese, Matthew A.</au><au>Werner, Frederick W.</au><au>Travers, Paul M.</au><au>Short, Walter H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>First Carpometacarpal Joint Motion and Proximal Migration of the First Metacarpal After Tensioning of a Suture Device Suspensionplasty Compared With Trapeziectomy: A Biomechanical Cadaver Study</atitle><jtitle>The Journal of hand surgery (American ed.)</jtitle><date>2023-11</date><risdate>2023</risdate><volume>48</volume><issue>11</issue><spage>1164</spage><epage>1164.e8</epage><pages>1164-1164.e8</pages><issn>0363-5023</issn><eissn>1531-6564</eissn><abstract>PURPOSEThe purpose of this cadaveric biomechanical experiment was to evaluate the effects of suture button suspensionplasty of the first carpometacarpal joint on thumb biomechanics and thumb position compared with an intact, arthritic specimen.METHODSSix tendons in 8 cadaver hands were loaded to simulate 6 activities of daily living and passively moved through a circumduction motion. Proximal migration of the base of the first metacarpal was measured using optical motion sensors in the intact hand, after trapeziectomy, and following insertion of a suture button suspensionplasty with nominal tightening (approximately 4.5 N) and with firm tightening (approximately 44.5 N).RESULTSRemoval of the trapezium caused a significant increase in the proximal migration of the first metacarpal during a simulated jar grasp, opposition, flexion, extension, and abduction (average, 9.5 mm) compared with its location with the thumb in the intact, neutral position (average, 3.8 mm). Firm tightening of the tightrope caused a near elimination of the proximal migration of the first metacarpal (average, 0.7 mm). In all 6 static loading cases with the trapezium removed, firm tightening caused a significantly smaller migration than in the absence of tightening.CONCLUSIONSThis biomechanical cadaver study supports the hypothesis that trapeziectomy results in proximal migration of the first metacarpal. Suture suspensionplasty mitigates against this migration while maintaining normal motion of the first metacarpal compared with the intact state. Firm tightening of the suture does not adversely affect the first metacarpal's mobility and further decreases proximal migration. However, firm tightening may cause impingement between the first and second metacarpals.CLINICAL RELEVANCESuture button suspensionplasty can be used in addition to trapeziectomy in the treatment of basal joint arthritis, and may diminish the need for ligament reconstruction or temporary K-wire insertion.</abstract><doi>10.1016/j.jhsa.2022.05.001</doi></addata></record>
fulltext fulltext
identifier ISSN: 0363-5023
ispartof The Journal of hand surgery (American ed.), 2023-11, Vol.48 (11), p.1164-1164.e8
issn 0363-5023
1531-6564
language eng
recordid cdi_proquest_miscellaneous_2732541956
source Elsevier ScienceDirect Journals Complete
title First Carpometacarpal Joint Motion and Proximal Migration of the First Metacarpal After Tensioning of a Suture Device Suspensionplasty Compared With Trapeziectomy: A Biomechanical Cadaver Study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T06%3A43%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=First%20Carpometacarpal%20Joint%20Motion%20and%20Proximal%20Migration%20of%20the%20First%20Metacarpal%20After%20Tensioning%20of%20a%20Suture%20Device%20Suspensionplasty%20Compared%20With%20Trapeziectomy:%20A%20Biomechanical%20Cadaver%20Study&rft.jtitle=The%20Journal%20of%20hand%20surgery%20(American%20ed.)&rft.au=Albanese,%20Matthew%20A.&rft.date=2023-11&rft.volume=48&rft.issue=11&rft.spage=1164&rft.epage=1164.e8&rft.pages=1164-1164.e8&rft.issn=0363-5023&rft.eissn=1531-6564&rft_id=info:doi/10.1016/j.jhsa.2022.05.001&rft_dat=%3Cproquest_cross%3E2732541956%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2732541956&rft_id=info:pmid/&rfr_iscdi=true