Use of electrocautery devices for suture passage through the greater tuberosity: a biomechanical study

The use of electrocautery to facilitate passage of a suture needle through bone without the aid of a drill or burr is a novel technique that has potential utility in orthopedic procedures, but there is a scarcity of research to support its utility. The specific aims of this cadaveric biomechanical s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of shoulder and elbow surgery 2023-03, Vol.32 (3), p.512-518
Hauptverfasser: Staggers, Jackson R., Chong, Alexander C.M., Piatt, Bruce E.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 518
container_issue 3
container_start_page 512
container_title Journal of shoulder and elbow surgery
container_volume 32
creator Staggers, Jackson R.
Chong, Alexander C.M.
Piatt, Bruce E.
description The use of electrocautery to facilitate passage of a suture needle through bone without the aid of a drill or burr is a novel technique that has potential utility in orthopedic procedures, but there is a scarcity of research to support its utility. The specific aims of this cadaveric biomechanical study were to evaluate (1) the axial force reduction during suture passage using electrocautery when applied to rotator cuff repair, (2) the temperature change caused while using electrocautery, and (3) the failure loads and failure modes of this technique. Five matched pairs of fresh frozen humeri were used, classified into 2 groups: with electrocautery on needle (study group) and without electrocautery on needle (control group). Four individual osseous tunnels were made on the greater tuberosity around the insertion of the supraspinatus tendon. Each specimen was sequentially tested in 2 parts: a needle penetration test (part I) to measure the peak axial force and temperature change and a single load-to-failure test (part II) to measure the maximum load to failure as well as the mechanism of failure. A No. 2 FiberWire suture with a straight needle was used. In part I, the mean peak axial force was lower in the study group compared with the control group for all osseous tunnels but was not statistically significant for individual tunnels. However, there was a significant decrease in peak axial force in the study group of 36% compared with the control group overall (P = .033). There was no significant change in temperature of the tunnel site with the use of electrocautery (mean: 0.2 ± 0.3°C, P = .435). In part II, 100% of the samples from each study group experienced bone tunnel failure. Forty percent of the trials in the study group found lower ultimate failure loads compared with the control group (reduction range: 7%-38%). There was no statistically significant difference in the ultimate failure load between either the loop tested or between the 2 study groups (loop 1: P = .352; loop 2: P = .270). Suture passage using electrocautery does significantly decrease the peak force needed to pass a needle directly through the greater tuberosity. This technique does not appear to burn the bone or weaken the bone tunnels. This technique may be useful during open rotator cuff repair or shoulder arthroplasty, although clinicians should be cautious when using this technique as its utility depends on bone quality and cortical thickness, and in vivo results may differ.
doi_str_mv 10.1016/j.jse.2022.09.020
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2729029045</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1058274622007935</els_id><sourcerecordid>2729029045</sourcerecordid><originalsourceid>FETCH-LOGICAL-c235t-caa2fc310218e4b2dac1c973ab6c06db9394f2546996e154e90fbea5ef62d5a93</originalsourceid><addsrcrecordid>eNp9kE1rGzEQhkVJadwkP6CXomMvux1pV7LVnIpJ2oKhl-YstNqRLbO2XH0Y_O8j4yTHwMDM4ZmXmYeQLwxaBkx-37bbhC0HzltQLXD4QGZMdLyRAuCqziAWDZ_38pp8TmkLAKoH_olcd5IvOiH7GXFPCWlwFCe0OQZrSsZ4oiMevcVEXYg0lVwi0oNJyayR5k0MZb2pHek6oqk8zWXAGJLPpx_U0MGHHdqN2XtrJppyGU-35KMzU8K7l35Dnh4f_i1_N6u_v_4sf64ayzuRG2sMd7ZjwNkC-4GPxjKr5p0ZpAU5DqpTveOil0pJZKJHBW5AI9BJPgqjuhvy7ZJ7iOF_wZT1zieL02T2GErSfM4V1OpFRdkFtfXyFNHpQ_Q7E0-agT7r1Vtd9eqzXg1KV7115-tLfBl2OL5tvPqswP0FwPrk0WPUyXrcWxx9rIL1GPw78c-78Yzl</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2729029045</pqid></control><display><type>article</type><title>Use of electrocautery devices for suture passage through the greater tuberosity: a biomechanical study</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Staggers, Jackson R. ; Chong, Alexander C.M. ; Piatt, Bruce E.</creator><creatorcontrib>Staggers, Jackson R. ; Chong, Alexander C.M. ; Piatt, Bruce E.</creatorcontrib><description>The use of electrocautery to facilitate passage of a suture needle through bone without the aid of a drill or burr is a novel technique that has potential utility in orthopedic procedures, but there is a scarcity of research to support its utility. The specific aims of this cadaveric biomechanical study were to evaluate (1) the axial force reduction during suture passage using electrocautery when applied to rotator cuff repair, (2) the temperature change caused while using electrocautery, and (3) the failure loads and failure modes of this technique. Five matched pairs of fresh frozen humeri were used, classified into 2 groups: with electrocautery on needle (study group) and without electrocautery on needle (control group). Four individual osseous tunnels were made on the greater tuberosity around the insertion of the supraspinatus tendon. Each specimen was sequentially tested in 2 parts: a needle penetration test (part I) to measure the peak axial force and temperature change and a single load-to-failure test (part II) to measure the maximum load to failure as well as the mechanism of failure. A No. 2 FiberWire suture with a straight needle was used. In part I, the mean peak axial force was lower in the study group compared with the control group for all osseous tunnels but was not statistically significant for individual tunnels. However, there was a significant decrease in peak axial force in the study group of 36% compared with the control group overall (P = .033). There was no significant change in temperature of the tunnel site with the use of electrocautery (mean: 0.2 ± 0.3°C, P = .435). In part II, 100% of the samples from each study group experienced bone tunnel failure. Forty percent of the trials in the study group found lower ultimate failure loads compared with the control group (reduction range: 7%-38%). There was no statistically significant difference in the ultimate failure load between either the loop tested or between the 2 study groups (loop 1: P = .352; loop 2: P = .270). Suture passage using electrocautery does significantly decrease the peak force needed to pass a needle directly through the greater tuberosity. This technique does not appear to burn the bone or weaken the bone tunnels. This technique may be useful during open rotator cuff repair or shoulder arthroplasty, although clinicians should be cautious when using this technique as its utility depends on bone quality and cortical thickness, and in vivo results may differ.</description><identifier>ISSN: 1058-2746</identifier><identifier>EISSN: 1532-6500</identifier><identifier>DOI: 10.1016/j.jse.2022.09.020</identifier><identifier>PMID: 36283564</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Biomechanical Phenomena ; biomechanical study ; Cadaver ; Electrocautery ; Electrocoagulation ; greater tuberosity ; Humans ; Rotator Cuff - surgery ; Rotator Cuff Injuries - surgery ; Suture Anchors ; suture passage ; Suture Techniques ; Sutures</subject><ispartof>Journal of shoulder and elbow surgery, 2023-03, Vol.32 (3), p.512-518</ispartof><rights>2022 Journal of Shoulder and Elbow Surgery Board of Trustees</rights><rights>Copyright © 2022 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c235t-caa2fc310218e4b2dac1c973ab6c06db9394f2546996e154e90fbea5ef62d5a93</cites><orcidid>0000-0002-4552-8314 ; 0000-0003-3300-9928</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jse.2022.09.020$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3549,27923,27924,45994</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36283564$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Staggers, Jackson R.</creatorcontrib><creatorcontrib>Chong, Alexander C.M.</creatorcontrib><creatorcontrib>Piatt, Bruce E.</creatorcontrib><title>Use of electrocautery devices for suture passage through the greater tuberosity: a biomechanical study</title><title>Journal of shoulder and elbow surgery</title><addtitle>J Shoulder Elbow Surg</addtitle><description>The use of electrocautery to facilitate passage of a suture needle through bone without the aid of a drill or burr is a novel technique that has potential utility in orthopedic procedures, but there is a scarcity of research to support its utility. The specific aims of this cadaveric biomechanical study were to evaluate (1) the axial force reduction during suture passage using electrocautery when applied to rotator cuff repair, (2) the temperature change caused while using electrocautery, and (3) the failure loads and failure modes of this technique. Five matched pairs of fresh frozen humeri were used, classified into 2 groups: with electrocautery on needle (study group) and without electrocautery on needle (control group). Four individual osseous tunnels were made on the greater tuberosity around the insertion of the supraspinatus tendon. Each specimen was sequentially tested in 2 parts: a needle penetration test (part I) to measure the peak axial force and temperature change and a single load-to-failure test (part II) to measure the maximum load to failure as well as the mechanism of failure. A No. 2 FiberWire suture with a straight needle was used. In part I, the mean peak axial force was lower in the study group compared with the control group for all osseous tunnels but was not statistically significant for individual tunnels. However, there was a significant decrease in peak axial force in the study group of 36% compared with the control group overall (P = .033). There was no significant change in temperature of the tunnel site with the use of electrocautery (mean: 0.2 ± 0.3°C, P = .435). In part II, 100% of the samples from each study group experienced bone tunnel failure. Forty percent of the trials in the study group found lower ultimate failure loads compared with the control group (reduction range: 7%-38%). There was no statistically significant difference in the ultimate failure load between either the loop tested or between the 2 study groups (loop 1: P = .352; loop 2: P = .270). Suture passage using electrocautery does significantly decrease the peak force needed to pass a needle directly through the greater tuberosity. This technique does not appear to burn the bone or weaken the bone tunnels. This technique may be useful during open rotator cuff repair or shoulder arthroplasty, although clinicians should be cautious when using this technique as its utility depends on bone quality and cortical thickness, and in vivo results may differ.</description><subject>Biomechanical Phenomena</subject><subject>biomechanical study</subject><subject>Cadaver</subject><subject>Electrocautery</subject><subject>Electrocoagulation</subject><subject>greater tuberosity</subject><subject>Humans</subject><subject>Rotator Cuff - surgery</subject><subject>Rotator Cuff Injuries - surgery</subject><subject>Suture Anchors</subject><subject>suture passage</subject><subject>Suture Techniques</subject><subject>Sutures</subject><issn>1058-2746</issn><issn>1532-6500</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1rGzEQhkVJadwkP6CXomMvux1pV7LVnIpJ2oKhl-YstNqRLbO2XH0Y_O8j4yTHwMDM4ZmXmYeQLwxaBkx-37bbhC0HzltQLXD4QGZMdLyRAuCqziAWDZ_38pp8TmkLAKoH_olcd5IvOiH7GXFPCWlwFCe0OQZrSsZ4oiMevcVEXYg0lVwi0oNJyayR5k0MZb2pHek6oqk8zWXAGJLPpx_U0MGHHdqN2XtrJppyGU-35KMzU8K7l35Dnh4f_i1_N6u_v_4sf64ayzuRG2sMd7ZjwNkC-4GPxjKr5p0ZpAU5DqpTveOil0pJZKJHBW5AI9BJPgqjuhvy7ZJ7iOF_wZT1zieL02T2GErSfM4V1OpFRdkFtfXyFNHpQ_Q7E0-agT7r1Vtd9eqzXg1KV7115-tLfBl2OL5tvPqswP0FwPrk0WPUyXrcWxx9rIL1GPw78c-78Yzl</recordid><startdate>202303</startdate><enddate>202303</enddate><creator>Staggers, Jackson R.</creator><creator>Chong, Alexander C.M.</creator><creator>Piatt, Bruce E.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-4552-8314</orcidid><orcidid>https://orcid.org/0000-0003-3300-9928</orcidid></search><sort><creationdate>202303</creationdate><title>Use of electrocautery devices for suture passage through the greater tuberosity: a biomechanical study</title><author>Staggers, Jackson R. ; Chong, Alexander C.M. ; Piatt, Bruce E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c235t-caa2fc310218e4b2dac1c973ab6c06db9394f2546996e154e90fbea5ef62d5a93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Biomechanical Phenomena</topic><topic>biomechanical study</topic><topic>Cadaver</topic><topic>Electrocautery</topic><topic>Electrocoagulation</topic><topic>greater tuberosity</topic><topic>Humans</topic><topic>Rotator Cuff - surgery</topic><topic>Rotator Cuff Injuries - surgery</topic><topic>Suture Anchors</topic><topic>suture passage</topic><topic>Suture Techniques</topic><topic>Sutures</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Staggers, Jackson R.</creatorcontrib><creatorcontrib>Chong, Alexander C.M.</creatorcontrib><creatorcontrib>Piatt, Bruce E.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of shoulder and elbow surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Staggers, Jackson R.</au><au>Chong, Alexander C.M.</au><au>Piatt, Bruce E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Use of electrocautery devices for suture passage through the greater tuberosity: a biomechanical study</atitle><jtitle>Journal of shoulder and elbow surgery</jtitle><addtitle>J Shoulder Elbow Surg</addtitle><date>2023-03</date><risdate>2023</risdate><volume>32</volume><issue>3</issue><spage>512</spage><epage>518</epage><pages>512-518</pages><issn>1058-2746</issn><eissn>1532-6500</eissn><abstract>The use of electrocautery to facilitate passage of a suture needle through bone without the aid of a drill or burr is a novel technique that has potential utility in orthopedic procedures, but there is a scarcity of research to support its utility. The specific aims of this cadaveric biomechanical study were to evaluate (1) the axial force reduction during suture passage using electrocautery when applied to rotator cuff repair, (2) the temperature change caused while using electrocautery, and (3) the failure loads and failure modes of this technique. Five matched pairs of fresh frozen humeri were used, classified into 2 groups: with electrocautery on needle (study group) and without electrocautery on needle (control group). Four individual osseous tunnels were made on the greater tuberosity around the insertion of the supraspinatus tendon. Each specimen was sequentially tested in 2 parts: a needle penetration test (part I) to measure the peak axial force and temperature change and a single load-to-failure test (part II) to measure the maximum load to failure as well as the mechanism of failure. A No. 2 FiberWire suture with a straight needle was used. In part I, the mean peak axial force was lower in the study group compared with the control group for all osseous tunnels but was not statistically significant for individual tunnels. However, there was a significant decrease in peak axial force in the study group of 36% compared with the control group overall (P = .033). There was no significant change in temperature of the tunnel site with the use of electrocautery (mean: 0.2 ± 0.3°C, P = .435). In part II, 100% of the samples from each study group experienced bone tunnel failure. Forty percent of the trials in the study group found lower ultimate failure loads compared with the control group (reduction range: 7%-38%). There was no statistically significant difference in the ultimate failure load between either the loop tested or between the 2 study groups (loop 1: P = .352; loop 2: P = .270). Suture passage using electrocautery does significantly decrease the peak force needed to pass a needle directly through the greater tuberosity. This technique does not appear to burn the bone or weaken the bone tunnels. This technique may be useful during open rotator cuff repair or shoulder arthroplasty, although clinicians should be cautious when using this technique as its utility depends on bone quality and cortical thickness, and in vivo results may differ.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>36283564</pmid><doi>10.1016/j.jse.2022.09.020</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-4552-8314</orcidid><orcidid>https://orcid.org/0000-0003-3300-9928</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1058-2746
ispartof Journal of shoulder and elbow surgery, 2023-03, Vol.32 (3), p.512-518
issn 1058-2746
1532-6500
language eng
recordid cdi_proquest_miscellaneous_2729029045
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Biomechanical Phenomena
biomechanical study
Cadaver
Electrocautery
Electrocoagulation
greater tuberosity
Humans
Rotator Cuff - surgery
Rotator Cuff Injuries - surgery
Suture Anchors
suture passage
Suture Techniques
Sutures
title Use of electrocautery devices for suture passage through the greater tuberosity: a biomechanical study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T05%3A10%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Use%20of%20electrocautery%20devices%20for%20suture%20passage%20through%20the%20greater%20tuberosity:%20a%20biomechanical%20study&rft.jtitle=Journal%20of%20shoulder%20and%20elbow%20surgery&rft.au=Staggers,%20Jackson%20R.&rft.date=2023-03&rft.volume=32&rft.issue=3&rft.spage=512&rft.epage=518&rft.pages=512-518&rft.issn=1058-2746&rft.eissn=1532-6500&rft_id=info:doi/10.1016/j.jse.2022.09.020&rft_dat=%3Cproquest_cross%3E2729029045%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2729029045&rft_id=info:pmid/36283564&rft_els_id=S1058274622007935&rfr_iscdi=true