The value of clinical symptoms, the neutrophil‐to‐lymphocyte ratio, and ultrasonographic features in predicting adnexal torsion: A case–control study
Aim Adnexal torsion remains a diagnostic challenge due to the nonspecific symptoms, sonographic features, and laboratory findings. The value of combining clinical, sonographic, and laboratory features is not well established, and controversy continues regarding their value in diagnosis. This study a...
Gespeichert in:
Veröffentlicht in: | The journal of obstetrics and gynaecology research 2023-01, Vol.49 (1), p.289-295 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Aim
Adnexal torsion remains a diagnostic challenge due to the nonspecific symptoms, sonographic features, and laboratory findings. The value of combining clinical, sonographic, and laboratory features is not well established, and controversy continues regarding their value in diagnosis. This study aimed to review sonographic, clinical, and laboratory features and to analyze their value separately and in combination, in managing and diagnosing adnexal torsions.
Methods
The study included 278 women who underwent urgent laparoscopic surgery due to suspected adnexal torsion, according to clinical suspicion, with or without sonographic concordance. Laparoscopy findings confirmed the definitive diagnosis of torsion. Clinical laboratory and sonographic features were compared between those with and without adnexal torsion.
Results
Adnexal torsion was confirmed in 110/278 (39.6%) women. In the torsion compared to nontorsion group, proportions were higher of women with acute abdominal pain in the preceding 24 h ([50] 45.5% vs. [35] 20.8%, p |
---|---|
ISSN: | 1341-8076 1447-0756 1447-0756 |