Stereo-phase rectification for metric profilometry with two calibrated cameras and one uncalibrated projector

Fringe projection profilometry requires calibrating both cameras and projectors for metric measurements. Cameras are relatively simple to calibrate, but projectors require more sophisticated procedures. In this paper, a fringe projection profilometer with two calibrated cameras and one uncalibrated...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied optics (2004) 2022-07, Vol.61 (21), p.6097-6109
Hauptverfasser: Juarez-Salazar, Rigoberto, Rios-Orellana, Obed I., Diaz-Ramirez, Victor H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 6109
container_issue 21
container_start_page 6097
container_title Applied optics (2004)
container_volume 61
creator Juarez-Salazar, Rigoberto
Rios-Orellana, Obed I.
Diaz-Ramirez, Victor H.
description Fringe projection profilometry requires calibrating both cameras and projectors for metric measurements. Cameras are relatively simple to calibrate, but projectors require more sophisticated procedures. In this paper, a fringe projection profilometer with two calibrated cameras and one uncalibrated projector is developed for metric measurements. A phase rectification method, which is crucial for stereo matching, is designed by minimizing the perspective distortion. Also, a simple method for point matching using stereo rectified phase maps is proposed. The principles of metric profilometry using the proposed rectification method are introduced. The developed system is evaluated experimentally by the metric measurement of three-dimensional objects. The obtained results confirm a high accuracy of metric measurement and versatility in the design of fringe projection profilometers with uncalibrated projectors.
doi_str_mv 10.1364/AO.461168
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2725650336</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2692291363</sourcerecordid><originalsourceid>FETCH-LOGICAL-c290t-a15b53a89fa3a21513d1dcb5a2af983eb215c0eb7fa717e531447b34f1ed1a893</originalsourceid><addsrcrecordid>eNpdUE1PwzAMjRBIjMGBfxCJCxw6mqRp1-M08SVN2gGQuEVu6miZ2mYkqab9ezKNA-LkZ_v52X6E3LJ8xkRZPC7Ws6JkrJyfkQlnUmaClfKcTBKsM8bnX5fkKoRtngtZ1NWE9O8RPbpst4GA1KOO1lgN0bqBGudpj9FbTXfeGdu5Y3agexs3NO4d1dDZxkPENsEePQQKQ0vdgHQc_jTT9DYpO39NLgx0AW9-45R8Pj99LF-z1frlbblYZZrXecyAyUYKmNcGBKQvmGhZqxsJHEw9F9ikms6xqQxUrEIpWFFUjSgMw5alMTEl9yfdtPl7xBBVb4PGroMB3RgUr7gsZS5Emah3_6hbN_ohXad4WXNeJ1tFYj2cWNq7EDwatfO2B39QLFdH49VirU7Gix-bL3cO</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2692291363</pqid></control><display><type>article</type><title>Stereo-phase rectification for metric profilometry with two calibrated cameras and one uncalibrated projector</title><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>Juarez-Salazar, Rigoberto ; Rios-Orellana, Obed I. ; Diaz-Ramirez, Victor H.</creator><creatorcontrib>Juarez-Salazar, Rigoberto ; Rios-Orellana, Obed I. ; Diaz-Ramirez, Victor H.</creatorcontrib><description>Fringe projection profilometry requires calibrating both cameras and projectors for metric measurements. Cameras are relatively simple to calibrate, but projectors require more sophisticated procedures. In this paper, a fringe projection profilometer with two calibrated cameras and one uncalibrated projector is developed for metric measurements. A phase rectification method, which is crucial for stereo matching, is designed by minimizing the perspective distortion. Also, a simple method for point matching using stereo rectified phase maps is proposed. The principles of metric profilometry using the proposed rectification method are introduced. The developed system is evaluated experimentally by the metric measurement of three-dimensional objects. The obtained results confirm a high accuracy of metric measurement and versatility in the design of fringe projection profilometers with uncalibrated projectors.</description><identifier>ISSN: 1559-128X</identifier><identifier>EISSN: 2155-3165</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/AO.461168</identifier><language>eng</language><publisher>Washington: Optical Society of America</publisher><subject>Calibration ; Cameras ; Forecasting ; Phase matching ; Profilometers ; Projectors</subject><ispartof>Applied optics (2004), 2022-07, Vol.61 (21), p.6097-6109</ispartof><rights>Copyright Optical Society of America Jul 20, 2022</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c290t-a15b53a89fa3a21513d1dcb5a2af983eb215c0eb7fa717e531447b34f1ed1a893</citedby><cites>FETCH-LOGICAL-c290t-a15b53a89fa3a21513d1dcb5a2af983eb215c0eb7fa717e531447b34f1ed1a893</cites><orcidid>0000-0002-9331-1777 ; 0000-0001-6917-7558</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,3258,27924,27925</link.rule.ids></links><search><creatorcontrib>Juarez-Salazar, Rigoberto</creatorcontrib><creatorcontrib>Rios-Orellana, Obed I.</creatorcontrib><creatorcontrib>Diaz-Ramirez, Victor H.</creatorcontrib><title>Stereo-phase rectification for metric profilometry with two calibrated cameras and one uncalibrated projector</title><title>Applied optics (2004)</title><description>Fringe projection profilometry requires calibrating both cameras and projectors for metric measurements. Cameras are relatively simple to calibrate, but projectors require more sophisticated procedures. In this paper, a fringe projection profilometer with two calibrated cameras and one uncalibrated projector is developed for metric measurements. A phase rectification method, which is crucial for stereo matching, is designed by minimizing the perspective distortion. Also, a simple method for point matching using stereo rectified phase maps is proposed. The principles of metric profilometry using the proposed rectification method are introduced. The developed system is evaluated experimentally by the metric measurement of three-dimensional objects. The obtained results confirm a high accuracy of metric measurement and versatility in the design of fringe projection profilometers with uncalibrated projectors.</description><subject>Calibration</subject><subject>Cameras</subject><subject>Forecasting</subject><subject>Phase matching</subject><subject>Profilometers</subject><subject>Projectors</subject><issn>1559-128X</issn><issn>2155-3165</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNpdUE1PwzAMjRBIjMGBfxCJCxw6mqRp1-M08SVN2gGQuEVu6miZ2mYkqab9ezKNA-LkZ_v52X6E3LJ8xkRZPC7Ws6JkrJyfkQlnUmaClfKcTBKsM8bnX5fkKoRtngtZ1NWE9O8RPbpst4GA1KOO1lgN0bqBGudpj9FbTXfeGdu5Y3agexs3NO4d1dDZxkPENsEePQQKQ0vdgHQc_jTT9DYpO39NLgx0AW9-45R8Pj99LF-z1frlbblYZZrXecyAyUYKmNcGBKQvmGhZqxsJHEw9F9ikms6xqQxUrEIpWFFUjSgMw5alMTEl9yfdtPl7xBBVb4PGroMB3RgUr7gsZS5Emah3_6hbN_ohXad4WXNeJ1tFYj2cWNq7EDwatfO2B39QLFdH49VirU7Gix-bL3cO</recordid><startdate>20220720</startdate><enddate>20220720</enddate><creator>Juarez-Salazar, Rigoberto</creator><creator>Rios-Orellana, Obed I.</creator><creator>Diaz-Ramirez, Victor H.</creator><general>Optical Society of America</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-9331-1777</orcidid><orcidid>https://orcid.org/0000-0001-6917-7558</orcidid></search><sort><creationdate>20220720</creationdate><title>Stereo-phase rectification for metric profilometry with two calibrated cameras and one uncalibrated projector</title><author>Juarez-Salazar, Rigoberto ; Rios-Orellana, Obed I. ; Diaz-Ramirez, Victor H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c290t-a15b53a89fa3a21513d1dcb5a2af983eb215c0eb7fa717e531447b34f1ed1a893</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Calibration</topic><topic>Cameras</topic><topic>Forecasting</topic><topic>Phase matching</topic><topic>Profilometers</topic><topic>Projectors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Juarez-Salazar, Rigoberto</creatorcontrib><creatorcontrib>Rios-Orellana, Obed I.</creatorcontrib><creatorcontrib>Diaz-Ramirez, Victor H.</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Applied optics (2004)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Juarez-Salazar, Rigoberto</au><au>Rios-Orellana, Obed I.</au><au>Diaz-Ramirez, Victor H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Stereo-phase rectification for metric profilometry with two calibrated cameras and one uncalibrated projector</atitle><jtitle>Applied optics (2004)</jtitle><date>2022-07-20</date><risdate>2022</risdate><volume>61</volume><issue>21</issue><spage>6097</spage><epage>6109</epage><pages>6097-6109</pages><issn>1559-128X</issn><eissn>2155-3165</eissn><eissn>1539-4522</eissn><abstract>Fringe projection profilometry requires calibrating both cameras and projectors for metric measurements. Cameras are relatively simple to calibrate, but projectors require more sophisticated procedures. In this paper, a fringe projection profilometer with two calibrated cameras and one uncalibrated projector is developed for metric measurements. A phase rectification method, which is crucial for stereo matching, is designed by minimizing the perspective distortion. Also, a simple method for point matching using stereo rectified phase maps is proposed. The principles of metric profilometry using the proposed rectification method are introduced. The developed system is evaluated experimentally by the metric measurement of three-dimensional objects. The obtained results confirm a high accuracy of metric measurement and versatility in the design of fringe projection profilometers with uncalibrated projectors.</abstract><cop>Washington</cop><pub>Optical Society of America</pub><doi>10.1364/AO.461168</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0002-9331-1777</orcidid><orcidid>https://orcid.org/0000-0001-6917-7558</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1559-128X
ispartof Applied optics (2004), 2022-07, Vol.61 (21), p.6097-6109
issn 1559-128X
2155-3165
1539-4522
language eng
recordid cdi_proquest_miscellaneous_2725650336
source Alma/SFX Local Collection; Optica Publishing Group Journals
subjects Calibration
Cameras
Forecasting
Phase matching
Profilometers
Projectors
title Stereo-phase rectification for metric profilometry with two calibrated cameras and one uncalibrated projector
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T00%3A43%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Stereo-phase%20rectification%20for%20metric%20profilometry%20with%20two%20calibrated%20cameras%20and%20one%20uncalibrated%20projector&rft.jtitle=Applied%20optics%20(2004)&rft.au=Juarez-Salazar,%20Rigoberto&rft.date=2022-07-20&rft.volume=61&rft.issue=21&rft.spage=6097&rft.epage=6109&rft.pages=6097-6109&rft.issn=1559-128X&rft.eissn=2155-3165&rft_id=info:doi/10.1364/AO.461168&rft_dat=%3Cproquest_cross%3E2692291363%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2692291363&rft_id=info:pmid/&rfr_iscdi=true