Functional biomechanical comparison of Latarjet vs. distal tibial osteochondral allograft for anterior glenoid defect reconstruction

Glenoid reconstruction is indicated for recurrent glenohumeral instability with significant glenoid bone deficiency. Coracoid autograft (Latarjet) and distal tibial osteochondral allograft (DTA) reconstructions have been used to successfully restore glenohumeral stability. Relative advantages and di...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of shoulder and elbow surgery 2023-02, Vol.32 (2), p.374-382
Hauptverfasser: Rodriguez, Alexander, Baumann, John, Bezold, Will, Smith, Conor, Thomas, Dimitri, Cook, James L., Smith, Matthew J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Glenoid reconstruction is indicated for recurrent glenohumeral instability with significant glenoid bone deficiency. Coracoid autograft (Latarjet) and distal tibial osteochondral allograft (DTA) reconstructions have been used to successfully restore glenohumeral stability. Relative advantages and disadvantages associated with each reconstruction technique have been described. However, direct comparisons of functional glenohumeral biomechanics associated with Latarjet vs. DTA reconstruction are lacking. This study was designed to compare these 2 glenoid reconstruction techniques with respect to joint kinematics and cartilage pressure mapping using a robotic testing system. In accordance with institutional review board policies, human cadaveric shoulders (n = 8) were cyclically tested in the neutral position and 90° of external rotation with 60° and 90° of abduction under a 45-N joint-compression load to measure clinically relevant translations, loads, and torques. Joint contact pressure maps were obtained under a 120-N joint-compression load using pressure mapping sensors. After confirming that a 25% anterior glenoid defect resulted in glenohumeral dislocation, testing was performed to compare 3 conditions: native intact glenoid, 25% anterior glenoid defect with Latarjet reconstruction, and 25% anterior glenoid defect with DTA reconstruction. Analyses of variance and t tests were used to analyze data with statistical significance set at P < .05. Significant differences in anterior translation, inferior drawer, anterior drawer, compression loads, horizontal abduction, negative elevation (adduction), and external rotation torques during cyclical testing in 90° of external rotation with 60° and/or 90° of abduction were noted when comparing the 2 different glenoid bone reconstruction techniques to native, intact shoulders. The only significant difference between Latarjet and DTA reconstructions for measured translations, loads, and torques was a significantly higher absolute maximum compressive load for Latarjet compared to DTA at 60° of abduction. Latarjet coracoid osseous autograft and distal tibial osteochondral allograft reconstructions of large (25%) glenoid bone defects prevent failure (dislocation) and are associated with significant glenohumeral kinematic differences that largely confer less translation, load, and torque on the joint in abduction when compared to the native state. These findings suggest that these 2 surgical techniques exhibit similar g
ISSN:1058-2746
1532-6500
DOI:10.1016/j.jse.2022.08.027