Electrochemical Disinfection of Saline Wastewater Effluent

A laboratory-scale electrochemical (EC) disinfector was used for the disinfection of various wastewater effluents, including saline primary effluent, saline secondary effluent, and freshwater secondary effluent. Such EC disinfection was highly effective for saline effluent with a salinity content of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of environmental engineering (New York, N.Y.) N.Y.), 2002-08, Vol.128 (8), p.697-704
Hauptverfasser: Li, X. Y, Ding, F, Lo, P. S. Y, Sin, S. H. P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 704
container_issue 8
container_start_page 697
container_title Journal of environmental engineering (New York, N.Y.)
container_volume 128
creator Li, X. Y
Ding, F
Lo, P. S. Y
Sin, S. H. P
description A laboratory-scale electrochemical (EC) disinfector was used for the disinfection of various wastewater effluents, including saline primary effluent, saline secondary effluent, and freshwater secondary effluent. Such EC disinfection was highly effective for saline effluent with a salinity content of around 8‰. A killing efficiency of 99.9% on total coliform bacteria was achieved for saline secondary effluent with a contact time of less than 10 s and a power consumption rate no more than 0.006kWh/m3. For primarily treated saline effluent, the same degree of disinfection was obtained with a contact time of less than 20 s and a power consumption of lower than 0.08 kWh/m3. The efficiency of EC disinfection was regulated by both the contact time (t) and current density (Id) applied, and a kinetic function in terms of survival ratio (N/N0) was developed for the saline secondary effluent, i.e., log(N/N0)=-0.01(Idt)1.87. While EC disinfection is highly applicable for saline effluent, it did not exhibit a similar degree of effectiveness for freshwater sewage effluent, even with a longer contact time and higher power input. Based on the results of the EC disinfection and comparative direct chlorination experiments, it is argued that the main disinfecting action of the EC process may not be electrochlorination. The EC process could produce other short-lived, more powerful germicidal substances that exert the strong killing function within a short contact time.
doi_str_mv 10.1061/(ASCE)0733-9372(2002)128:8(697)
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_27177132</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>14633604</sourcerecordid><originalsourceid>FETCH-LOGICAL-a538t-a29e96ea2dedccfeeaf8a0e442896bc8125f4506c1760aec0d6e85211a6f5b9b3</originalsourceid><addsrcrecordid>eNqFkctOwzAQRS0EEuXxD9kA7SIwthPbYYFUlfBSJRaAYGe57lgEpQnYqRB_j0N57KgX49Ho6M7oXkKOKBxTEPRkOL6blCOQnKcFl2zIANiIMnWqhqKQow0yoEXGU6kkbJLBL7dNdkJ4AaBZpAbktKzRdr61z7iorKmT8ypUjYuzqm2S1iV3pq4aTB5N6PDddOiT0rl6iU23R7acqQPuf_-75OGivJ9cpdPby-vJeJqanKsuNazAQqBhc5xb6xCNUwYwy5gqxMwqynKX5SAslQIMWpgLVDmj1AiXz4oZ3yWHK91X374tMXR6UQWLdW0abJdBM0mlpJytBamgGQih1oOZ4FxAFsGzFWh9G4JHp199tTD-Q1PQfQpa9yno3l3du6v7FHRMQSsd_Y0CB9-bTIjuOm8aW4U_Fa5AqKJf9LTiIob6pV36Jlqqb27L8vwBYlpMQf_6GnW_evpzw_8nfAINaqBX</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14633604</pqid></control><display><type>article</type><title>Electrochemical Disinfection of Saline Wastewater Effluent</title><source>American Society of Civil Engineers:NESLI2:Journals:2014</source><source>EBSCOhost Business Source Complete</source><creator>Li, X. Y ; Ding, F ; Lo, P. S. Y ; Sin, S. H. P</creator><creatorcontrib>Li, X. Y ; Ding, F ; Lo, P. S. Y ; Sin, S. H. P</creatorcontrib><description>A laboratory-scale electrochemical (EC) disinfector was used for the disinfection of various wastewater effluents, including saline primary effluent, saline secondary effluent, and freshwater secondary effluent. Such EC disinfection was highly effective for saline effluent with a salinity content of around 8‰. A killing efficiency of 99.9% on total coliform bacteria was achieved for saline secondary effluent with a contact time of less than 10 s and a power consumption rate no more than 0.006kWh/m3. For primarily treated saline effluent, the same degree of disinfection was obtained with a contact time of less than 20 s and a power consumption of lower than 0.08 kWh/m3. The efficiency of EC disinfection was regulated by both the contact time (t) and current density (Id) applied, and a kinetic function in terms of survival ratio (N/N0) was developed for the saline secondary effluent, i.e., log(N/N0)=-0.01(Idt)1.87. While EC disinfection is highly applicable for saline effluent, it did not exhibit a similar degree of effectiveness for freshwater sewage effluent, even with a longer contact time and higher power input. Based on the results of the EC disinfection and comparative direct chlorination experiments, it is argued that the main disinfecting action of the EC process may not be electrochlorination. The EC process could produce other short-lived, more powerful germicidal substances that exert the strong killing function within a short contact time.</description><identifier>ISSN: 0733-9372</identifier><identifier>EISSN: 1943-7870</identifier><identifier>DOI: 10.1061/(ASCE)0733-9372(2002)128:8(697)</identifier><identifier>CODEN: JOEEDU</identifier><language>eng</language><publisher>Reston, VA: American Society of Civil Engineers</publisher><subject>Applied sciences ; Chlorination ; Coliforms ; Disinfection ; Exact sciences and technology ; General purification processes ; Pollution ; Salinity ; TECHNICAL PAPERS ; Wastewater ; Wastewaters ; Water treatment and pollution</subject><ispartof>Journal of environmental engineering (New York, N.Y.), 2002-08, Vol.128 (8), p.697-704</ispartof><rights>Copyright © 2002 American Society of Civil Engineers</rights><rights>2002 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a538t-a29e96ea2dedccfeeaf8a0e442896bc8125f4506c1760aec0d6e85211a6f5b9b3</citedby><cites>FETCH-LOGICAL-a538t-a29e96ea2dedccfeeaf8a0e442896bc8125f4506c1760aec0d6e85211a6f5b9b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttp://ascelibrary.org/doi/pdf/10.1061/(ASCE)0733-9372(2002)128:8(697)$$EPDF$$P50$$Gasce$$H</linktopdf><linktohtml>$$Uhttp://ascelibrary.org/doi/abs/10.1061/(ASCE)0733-9372(2002)128:8(697)$$EHTML$$P50$$Gasce$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,75935,75943</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=13806894$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Li, X. Y</creatorcontrib><creatorcontrib>Ding, F</creatorcontrib><creatorcontrib>Lo, P. S. Y</creatorcontrib><creatorcontrib>Sin, S. H. P</creatorcontrib><title>Electrochemical Disinfection of Saline Wastewater Effluent</title><title>Journal of environmental engineering (New York, N.Y.)</title><description>A laboratory-scale electrochemical (EC) disinfector was used for the disinfection of various wastewater effluents, including saline primary effluent, saline secondary effluent, and freshwater secondary effluent. Such EC disinfection was highly effective for saline effluent with a salinity content of around 8‰. A killing efficiency of 99.9% on total coliform bacteria was achieved for saline secondary effluent with a contact time of less than 10 s and a power consumption rate no more than 0.006kWh/m3. For primarily treated saline effluent, the same degree of disinfection was obtained with a contact time of less than 20 s and a power consumption of lower than 0.08 kWh/m3. The efficiency of EC disinfection was regulated by both the contact time (t) and current density (Id) applied, and a kinetic function in terms of survival ratio (N/N0) was developed for the saline secondary effluent, i.e., log(N/N0)=-0.01(Idt)1.87. While EC disinfection is highly applicable for saline effluent, it did not exhibit a similar degree of effectiveness for freshwater sewage effluent, even with a longer contact time and higher power input. Based on the results of the EC disinfection and comparative direct chlorination experiments, it is argued that the main disinfecting action of the EC process may not be electrochlorination. The EC process could produce other short-lived, more powerful germicidal substances that exert the strong killing function within a short contact time.</description><subject>Applied sciences</subject><subject>Chlorination</subject><subject>Coliforms</subject><subject>Disinfection</subject><subject>Exact sciences and technology</subject><subject>General purification processes</subject><subject>Pollution</subject><subject>Salinity</subject><subject>TECHNICAL PAPERS</subject><subject>Wastewater</subject><subject>Wastewaters</subject><subject>Water treatment and pollution</subject><issn>0733-9372</issn><issn>1943-7870</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNqFkctOwzAQRS0EEuXxD9kA7SIwthPbYYFUlfBSJRaAYGe57lgEpQnYqRB_j0N57KgX49Ho6M7oXkKOKBxTEPRkOL6blCOQnKcFl2zIANiIMnWqhqKQow0yoEXGU6kkbJLBL7dNdkJ4AaBZpAbktKzRdr61z7iorKmT8ypUjYuzqm2S1iV3pq4aTB5N6PDddOiT0rl6iU23R7acqQPuf_-75OGivJ9cpdPby-vJeJqanKsuNazAQqBhc5xb6xCNUwYwy5gqxMwqynKX5SAslQIMWpgLVDmj1AiXz4oZ3yWHK91X374tMXR6UQWLdW0abJdBM0mlpJytBamgGQih1oOZ4FxAFsGzFWh9G4JHp199tTD-Q1PQfQpa9yno3l3du6v7FHRMQSsd_Y0CB9-bTIjuOm8aW4U_Fa5AqKJf9LTiIob6pV36Jlqqb27L8vwBYlpMQf_6GnW_evpzw_8nfAINaqBX</recordid><startdate>20020801</startdate><enddate>20020801</enddate><creator>Li, X. Y</creator><creator>Ding, F</creator><creator>Lo, P. S. Y</creator><creator>Sin, S. H. P</creator><general>American Society of Civil Engineers</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>7QH</scope><scope>7UA</scope><scope>7SU</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20020801</creationdate><title>Electrochemical Disinfection of Saline Wastewater Effluent</title><author>Li, X. Y ; Ding, F ; Lo, P. S. Y ; Sin, S. H. P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a538t-a29e96ea2dedccfeeaf8a0e442896bc8125f4506c1760aec0d6e85211a6f5b9b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Applied sciences</topic><topic>Chlorination</topic><topic>Coliforms</topic><topic>Disinfection</topic><topic>Exact sciences and technology</topic><topic>General purification processes</topic><topic>Pollution</topic><topic>Salinity</topic><topic>TECHNICAL PAPERS</topic><topic>Wastewater</topic><topic>Wastewaters</topic><topic>Water treatment and pollution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Li, X. Y</creatorcontrib><creatorcontrib>Ding, F</creatorcontrib><creatorcontrib>Lo, P. S. Y</creatorcontrib><creatorcontrib>Sin, S. H. P</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Aqualine</collection><collection>Water Resources Abstracts</collection><collection>Environmental Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Journal of environmental engineering (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Li, X. Y</au><au>Ding, F</au><au>Lo, P. S. Y</au><au>Sin, S. H. P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrochemical Disinfection of Saline Wastewater Effluent</atitle><jtitle>Journal of environmental engineering (New York, N.Y.)</jtitle><date>2002-08-01</date><risdate>2002</risdate><volume>128</volume><issue>8</issue><spage>697</spage><epage>704</epage><pages>697-704</pages><issn>0733-9372</issn><eissn>1943-7870</eissn><coden>JOEEDU</coden><abstract>A laboratory-scale electrochemical (EC) disinfector was used for the disinfection of various wastewater effluents, including saline primary effluent, saline secondary effluent, and freshwater secondary effluent. Such EC disinfection was highly effective for saline effluent with a salinity content of around 8‰. A killing efficiency of 99.9% on total coliform bacteria was achieved for saline secondary effluent with a contact time of less than 10 s and a power consumption rate no more than 0.006kWh/m3. For primarily treated saline effluent, the same degree of disinfection was obtained with a contact time of less than 20 s and a power consumption of lower than 0.08 kWh/m3. The efficiency of EC disinfection was regulated by both the contact time (t) and current density (Id) applied, and a kinetic function in terms of survival ratio (N/N0) was developed for the saline secondary effluent, i.e., log(N/N0)=-0.01(Idt)1.87. While EC disinfection is highly applicable for saline effluent, it did not exhibit a similar degree of effectiveness for freshwater sewage effluent, even with a longer contact time and higher power input. Based on the results of the EC disinfection and comparative direct chlorination experiments, it is argued that the main disinfecting action of the EC process may not be electrochlorination. The EC process could produce other short-lived, more powerful germicidal substances that exert the strong killing function within a short contact time.</abstract><cop>Reston, VA</cop><pub>American Society of Civil Engineers</pub><doi>10.1061/(ASCE)0733-9372(2002)128:8(697)</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0733-9372
ispartof Journal of environmental engineering (New York, N.Y.), 2002-08, Vol.128 (8), p.697-704
issn 0733-9372
1943-7870
language eng
recordid cdi_proquest_miscellaneous_27177132
source American Society of Civil Engineers:NESLI2:Journals:2014; EBSCOhost Business Source Complete
subjects Applied sciences
Chlorination
Coliforms
Disinfection
Exact sciences and technology
General purification processes
Pollution
Salinity
TECHNICAL PAPERS
Wastewater
Wastewaters
Water treatment and pollution
title Electrochemical Disinfection of Saline Wastewater Effluent
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T05%3A18%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrochemical%20Disinfection%20of%20Saline%20Wastewater%20Effluent&rft.jtitle=Journal%20of%20environmental%20engineering%20(New%20York,%20N.Y.)&rft.au=Li,%20X.%20Y&rft.date=2002-08-01&rft.volume=128&rft.issue=8&rft.spage=697&rft.epage=704&rft.pages=697-704&rft.issn=0733-9372&rft.eissn=1943-7870&rft.coden=JOEEDU&rft_id=info:doi/10.1061/(ASCE)0733-9372(2002)128:8(697)&rft_dat=%3Cproquest_cross%3E14633604%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=14633604&rft_id=info:pmid/&rfr_iscdi=true