Biomechanical Comparison of Cannulated Screw Osteosynthesis With Tension-Band Wiring for Proximal Fractures of the Fifth Metatarsal (Jones Fracture)

Jones fractures, which lie at the junction of the diaphysis to the metaphysis of the fifth metatarsal, are a well-described clinical issue. There are various surgical approaches, including the commonly performed cannulated screw osteosyntheses, and the less frequently used tension-band approach. The...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of foot and ankle surgery 2023-03, Vol.62 (2), p.300-303
Hauptverfasser: Unthan, Mark, Graul, Isabel, Hallbauer, Jakob, Lindner, Robert, Hofmann, Gunther O., Kohler, Felix C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 303
container_issue 2
container_start_page 300
container_title The Journal of foot and ankle surgery
container_volume 62
creator Unthan, Mark
Graul, Isabel
Hallbauer, Jakob
Lindner, Robert
Hofmann, Gunther O.
Kohler, Felix C.
description Jones fractures, which lie at the junction of the diaphysis to the metaphysis of the fifth metatarsal, are a well-described clinical issue. There are various surgical approaches, including the commonly performed cannulated screw osteosyntheses, and the less frequently used tension-band approach. The aim is to compare the biomechanical stability of these osteosyntheses. We performed an osteotomy on 16 fresh frozen fifth metatarsal bones from body donors representing a Jones fracture. The fractures were treated pairwise with screw osteosynthesis or tension-band wiring. This was followed by cyclic axial bending until osteosynthesis failure. Stability under axial bending force was higher in the screw osteosynthesis (mean: 70.0 ± 66.5 N) compared to the tension-band wiring (mean: 35.7 ± 23.3 N) group although not reaching statistical significance (p = .116). The study shows no statistically significant difference in biomechanical stability under axial loading between screw osteosynthesis and tension band wiring. Based on the data obtained, no differences can be observed from a biomechanical point of view. The study supports the established method of treating Jones fractures primarily with screw osteosynthesis. In addition, the data suggest that tension band wiring may be a good alternative osteosynthesis, for example, after failed casting treatment or failure of primary osteosynthesis.
doi_str_mv 10.1053/j.jfas.2022.08.004
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2717689066</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1067251622002344</els_id><sourcerecordid>2717689066</sourcerecordid><originalsourceid>FETCH-LOGICAL-c400t-1af24b1235487dea420a60c6ad00ef166e803d4399eb0da3024dd6982981b9033</originalsourceid><addsrcrecordid>eNp9kctu1DAUhi1ERUvhBVggL8si6bGdeBKJDR11uKioSBSxtDz2CeNRYg-208t78MB4NC1LVrbs7_-kc35C3jCoGbTifFtvB51qDpzX0NUAzTNywtqGV5zz5nm5g1xUvGXymLxMaQsF7Lv2BTkWkrXQd-KE_LlwYUKz0d4ZPdJlmHY6uhQ8DQNdau_nUWe09LuJeEevU8aQHnzeYHKJ_nR5Q2_QJxd8daG9LS_R-V90CJF-i-HeTcW5itrkOWLaK0uSrtxQcl8x66xjKsTZl-DL9xP47hU5GvSY8PXjeUp-rC5vlp-qq-uPn5cfrirTAOSK6YE3a8ZF23QLi7rhoCUYqS0ADkxK7EDYRvQ9rsFqAbyxVvZdWQJb9yDEKTk7eHcx_J4xZTW5ZHActccwJ8UXbCG7HqQsKD-gJoaUIg5qF8t08UExUPs21Fbt21D7NhR0qrRRQm8f_fN6Qvsv8rT-Arw_AFimvHUYVTIOvUHrIpqsbHD_8_8FC6uc0g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2717689066</pqid></control><display><type>article</type><title>Biomechanical Comparison of Cannulated Screw Osteosynthesis With Tension-Band Wiring for Proximal Fractures of the Fifth Metatarsal (Jones Fracture)</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Unthan, Mark ; Graul, Isabel ; Hallbauer, Jakob ; Lindner, Robert ; Hofmann, Gunther O. ; Kohler, Felix C.</creator><creatorcontrib>Unthan, Mark ; Graul, Isabel ; Hallbauer, Jakob ; Lindner, Robert ; Hofmann, Gunther O. ; Kohler, Felix C.</creatorcontrib><description>Jones fractures, which lie at the junction of the diaphysis to the metaphysis of the fifth metatarsal, are a well-described clinical issue. There are various surgical approaches, including the commonly performed cannulated screw osteosyntheses, and the less frequently used tension-band approach. The aim is to compare the biomechanical stability of these osteosyntheses. We performed an osteotomy on 16 fresh frozen fifth metatarsal bones from body donors representing a Jones fracture. The fractures were treated pairwise with screw osteosynthesis or tension-band wiring. This was followed by cyclic axial bending until osteosynthesis failure. Stability under axial bending force was higher in the screw osteosynthesis (mean: 70.0 ± 66.5 N) compared to the tension-band wiring (mean: 35.7 ± 23.3 N) group although not reaching statistical significance (p = .116). The study shows no statistically significant difference in biomechanical stability under axial loading between screw osteosynthesis and tension band wiring. Based on the data obtained, no differences can be observed from a biomechanical point of view. The study supports the established method of treating Jones fractures primarily with screw osteosynthesis. In addition, the data suggest that tension band wiring may be a good alternative osteosynthesis, for example, after failed casting treatment or failure of primary osteosynthesis.</description><identifier>ISSN: 1067-2516</identifier><identifier>EISSN: 1542-2224</identifier><identifier>DOI: 10.1053/j.jfas.2022.08.004</identifier><identifier>PMID: 36150983</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>foot and ankle surgery ; lag screw ; proximal fifth metatarsal fracture</subject><ispartof>The Journal of foot and ankle surgery, 2023-03, Vol.62 (2), p.300-303</ispartof><rights>2022 The Authors</rights><rights>Copyright © 2022 The Authors. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c400t-1af24b1235487dea420a60c6ad00ef166e803d4399eb0da3024dd6982981b9033</citedby><cites>FETCH-LOGICAL-c400t-1af24b1235487dea420a60c6ad00ef166e803d4399eb0da3024dd6982981b9033</cites><orcidid>0000-0002-6863-9025</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1053/j.jfas.2022.08.004$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36150983$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Unthan, Mark</creatorcontrib><creatorcontrib>Graul, Isabel</creatorcontrib><creatorcontrib>Hallbauer, Jakob</creatorcontrib><creatorcontrib>Lindner, Robert</creatorcontrib><creatorcontrib>Hofmann, Gunther O.</creatorcontrib><creatorcontrib>Kohler, Felix C.</creatorcontrib><title>Biomechanical Comparison of Cannulated Screw Osteosynthesis With Tension-Band Wiring for Proximal Fractures of the Fifth Metatarsal (Jones Fracture)</title><title>The Journal of foot and ankle surgery</title><addtitle>J Foot Ankle Surg</addtitle><description>Jones fractures, which lie at the junction of the diaphysis to the metaphysis of the fifth metatarsal, are a well-described clinical issue. There are various surgical approaches, including the commonly performed cannulated screw osteosyntheses, and the less frequently used tension-band approach. The aim is to compare the biomechanical stability of these osteosyntheses. We performed an osteotomy on 16 fresh frozen fifth metatarsal bones from body donors representing a Jones fracture. The fractures were treated pairwise with screw osteosynthesis or tension-band wiring. This was followed by cyclic axial bending until osteosynthesis failure. Stability under axial bending force was higher in the screw osteosynthesis (mean: 70.0 ± 66.5 N) compared to the tension-band wiring (mean: 35.7 ± 23.3 N) group although not reaching statistical significance (p = .116). The study shows no statistically significant difference in biomechanical stability under axial loading between screw osteosynthesis and tension band wiring. Based on the data obtained, no differences can be observed from a biomechanical point of view. The study supports the established method of treating Jones fractures primarily with screw osteosynthesis. In addition, the data suggest that tension band wiring may be a good alternative osteosynthesis, for example, after failed casting treatment or failure of primary osteosynthesis.</description><subject>foot and ankle surgery</subject><subject>lag screw</subject><subject>proximal fifth metatarsal fracture</subject><issn>1067-2516</issn><issn>1542-2224</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kctu1DAUhi1ERUvhBVggL8si6bGdeBKJDR11uKioSBSxtDz2CeNRYg-208t78MB4NC1LVrbs7_-kc35C3jCoGbTifFtvB51qDpzX0NUAzTNywtqGV5zz5nm5g1xUvGXymLxMaQsF7Lv2BTkWkrXQd-KE_LlwYUKz0d4ZPdJlmHY6uhQ8DQNdau_nUWe09LuJeEevU8aQHnzeYHKJ_nR5Q2_QJxd8daG9LS_R-V90CJF-i-HeTcW5itrkOWLaK0uSrtxQcl8x66xjKsTZl-DL9xP47hU5GvSY8PXjeUp-rC5vlp-qq-uPn5cfrirTAOSK6YE3a8ZF23QLi7rhoCUYqS0ADkxK7EDYRvQ9rsFqAbyxVvZdWQJb9yDEKTk7eHcx_J4xZTW5ZHActccwJ8UXbCG7HqQsKD-gJoaUIg5qF8t08UExUPs21Fbt21D7NhR0qrRRQm8f_fN6Qvsv8rT-Arw_AFimvHUYVTIOvUHrIpqsbHD_8_8FC6uc0g</recordid><startdate>202303</startdate><enddate>202303</enddate><creator>Unthan, Mark</creator><creator>Graul, Isabel</creator><creator>Hallbauer, Jakob</creator><creator>Lindner, Robert</creator><creator>Hofmann, Gunther O.</creator><creator>Kohler, Felix C.</creator><general>Elsevier Inc</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-6863-9025</orcidid></search><sort><creationdate>202303</creationdate><title>Biomechanical Comparison of Cannulated Screw Osteosynthesis With Tension-Band Wiring for Proximal Fractures of the Fifth Metatarsal (Jones Fracture)</title><author>Unthan, Mark ; Graul, Isabel ; Hallbauer, Jakob ; Lindner, Robert ; Hofmann, Gunther O. ; Kohler, Felix C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c400t-1af24b1235487dea420a60c6ad00ef166e803d4399eb0da3024dd6982981b9033</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>foot and ankle surgery</topic><topic>lag screw</topic><topic>proximal fifth metatarsal fracture</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Unthan, Mark</creatorcontrib><creatorcontrib>Graul, Isabel</creatorcontrib><creatorcontrib>Hallbauer, Jakob</creatorcontrib><creatorcontrib>Lindner, Robert</creatorcontrib><creatorcontrib>Hofmann, Gunther O.</creatorcontrib><creatorcontrib>Kohler, Felix C.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of foot and ankle surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Unthan, Mark</au><au>Graul, Isabel</au><au>Hallbauer, Jakob</au><au>Lindner, Robert</au><au>Hofmann, Gunther O.</au><au>Kohler, Felix C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biomechanical Comparison of Cannulated Screw Osteosynthesis With Tension-Band Wiring for Proximal Fractures of the Fifth Metatarsal (Jones Fracture)</atitle><jtitle>The Journal of foot and ankle surgery</jtitle><addtitle>J Foot Ankle Surg</addtitle><date>2023-03</date><risdate>2023</risdate><volume>62</volume><issue>2</issue><spage>300</spage><epage>303</epage><pages>300-303</pages><issn>1067-2516</issn><eissn>1542-2224</eissn><abstract>Jones fractures, which lie at the junction of the diaphysis to the metaphysis of the fifth metatarsal, are a well-described clinical issue. There are various surgical approaches, including the commonly performed cannulated screw osteosyntheses, and the less frequently used tension-band approach. The aim is to compare the biomechanical stability of these osteosyntheses. We performed an osteotomy on 16 fresh frozen fifth metatarsal bones from body donors representing a Jones fracture. The fractures were treated pairwise with screw osteosynthesis or tension-band wiring. This was followed by cyclic axial bending until osteosynthesis failure. Stability under axial bending force was higher in the screw osteosynthesis (mean: 70.0 ± 66.5 N) compared to the tension-band wiring (mean: 35.7 ± 23.3 N) group although not reaching statistical significance (p = .116). The study shows no statistically significant difference in biomechanical stability under axial loading between screw osteosynthesis and tension band wiring. Based on the data obtained, no differences can be observed from a biomechanical point of view. The study supports the established method of treating Jones fractures primarily with screw osteosynthesis. In addition, the data suggest that tension band wiring may be a good alternative osteosynthesis, for example, after failed casting treatment or failure of primary osteosynthesis.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>36150983</pmid><doi>10.1053/j.jfas.2022.08.004</doi><tpages>4</tpages><orcidid>https://orcid.org/0000-0002-6863-9025</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1067-2516
ispartof The Journal of foot and ankle surgery, 2023-03, Vol.62 (2), p.300-303
issn 1067-2516
1542-2224
language eng
recordid cdi_proquest_miscellaneous_2717689066
source Elsevier ScienceDirect Journals Complete
subjects foot and ankle surgery
lag screw
proximal fifth metatarsal fracture
title Biomechanical Comparison of Cannulated Screw Osteosynthesis With Tension-Band Wiring for Proximal Fractures of the Fifth Metatarsal (Jones Fracture)
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T09%3A45%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biomechanical%20Comparison%20of%20Cannulated%20Screw%20Osteosynthesis%20With%20Tension-Band%20Wiring%20for%20Proximal%20Fractures%20of%20the%20Fifth%20Metatarsal%20(Jones%20Fracture)&rft.jtitle=The%20Journal%20of%20foot%20and%20ankle%20surgery&rft.au=Unthan,%20Mark&rft.date=2023-03&rft.volume=62&rft.issue=2&rft.spage=300&rft.epage=303&rft.pages=300-303&rft.issn=1067-2516&rft.eissn=1542-2224&rft_id=info:doi/10.1053/j.jfas.2022.08.004&rft_dat=%3Cproquest_cross%3E2717689066%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2717689066&rft_id=info:pmid/36150983&rft_els_id=S1067251622002344&rfr_iscdi=true