Transmission electron microscopies of magnetic microstructures

Since its introduction 40 years ago Lorentz microscopy has been used extensively to study domain structures in magnetic thin films and elements. Here we review the principal imaging modes, with emphasis on those introduced most recently, and discuss their advantages and drawbacks. Special emphasis i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of magnetism and magnetic materials 1999-10, Vol.200 (1), p.729-740
Hauptverfasser: Chapman, J.N, Scheinfein, M.R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 740
container_issue 1
container_start_page 729
container_title Journal of magnetism and magnetic materials
container_volume 200
creator Chapman, J.N
Scheinfein, M.R
description Since its introduction 40 years ago Lorentz microscopy has been used extensively to study domain structures in magnetic thin films and elements. Here we review the principal imaging modes, with emphasis on those introduced most recently, and discuss their advantages and drawbacks. Special emphasis is given to the development of methodologies which allow the magnetic state of a specimen to be changed in situ and which allow a full quantitative description of the spatial variation of magnetic induction to be extracted. Examples of each are presented. Finally, we discuss areas where further technique development will be beneficial.
doi_str_mv 10.1016/S0304-8853(99)00317-0
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_27173573</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0304885399003170</els_id><sourcerecordid>27173573</sourcerecordid><originalsourceid>FETCH-LOGICAL-c369t-2ed2da02a21df79de49f385e846c10aba8b8c20a3f6739be4b95d87ae2157a013</originalsourceid><addsrcrecordid>eNqNkE1LxDAQhnNQcF39CcKeRA_VSdLm46LI4hcseHA9hzSZSqQfa9IK_nvb3cWrnmaYed9h3oeQMwpXFKi4fgUOeaZUwS-0vgTgVGZwQGa_4yNynNIHANBciRm5WUfbpiakFLp2gTW6Po5NE1zskus2AdOiqxaNfW-xD26_6OPg-iFiOiGHla0Tnu7rnLw93K-XT9nq5fF5ebfKHBe6zxh65i0wy6ivpPaY64qrAlUuHAVbWlUqx8DySkiuS8xLXXglLTJaSAuUz8n57u4mdp8Dpt6MLzusa9tiNyTDJJW8kPw_QsEETMJiJ5zypIiV2cTQ2PhtKJgJpdmiNBMzo7XZojQw-m53PhzjfgWMJrmArUMf4gjP-C78ceEHael-Vw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>27162603</pqid></control><display><type>article</type><title>Transmission electron microscopies of magnetic microstructures</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Chapman, J.N ; Scheinfein, M.R</creator><creatorcontrib>Chapman, J.N ; Scheinfein, M.R</creatorcontrib><description>Since its introduction 40 years ago Lorentz microscopy has been used extensively to study domain structures in magnetic thin films and elements. Here we review the principal imaging modes, with emphasis on those introduced most recently, and discuss their advantages and drawbacks. Special emphasis is given to the development of methodologies which allow the magnetic state of a specimen to be changed in situ and which allow a full quantitative description of the spatial variation of magnetic induction to be extracted. Examples of each are presented. Finally, we discuss areas where further technique development will be beneficial.</description><identifier>ISSN: 0304-8853</identifier><identifier>DOI: 10.1016/S0304-8853(99)00317-0</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Domain structure ; Lorentz imaging ; Transmission electron microscope</subject><ispartof>Journal of magnetism and magnetic materials, 1999-10, Vol.200 (1), p.729-740</ispartof><rights>1999 Elsevier Science B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c369t-2ed2da02a21df79de49f385e846c10aba8b8c20a3f6739be4b95d87ae2157a013</citedby><cites>FETCH-LOGICAL-c369t-2ed2da02a21df79de49f385e846c10aba8b8c20a3f6739be4b95d87ae2157a013</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0304885399003170$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,65309</link.rule.ids></links><search><creatorcontrib>Chapman, J.N</creatorcontrib><creatorcontrib>Scheinfein, M.R</creatorcontrib><title>Transmission electron microscopies of magnetic microstructures</title><title>Journal of magnetism and magnetic materials</title><description>Since its introduction 40 years ago Lorentz microscopy has been used extensively to study domain structures in magnetic thin films and elements. Here we review the principal imaging modes, with emphasis on those introduced most recently, and discuss their advantages and drawbacks. Special emphasis is given to the development of methodologies which allow the magnetic state of a specimen to be changed in situ and which allow a full quantitative description of the spatial variation of magnetic induction to be extracted. Examples of each are presented. Finally, we discuss areas where further technique development will be beneficial.</description><subject>Domain structure</subject><subject>Lorentz imaging</subject><subject>Transmission electron microscope</subject><issn>0304-8853</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNqNkE1LxDAQhnNQcF39CcKeRA_VSdLm46LI4hcseHA9hzSZSqQfa9IK_nvb3cWrnmaYed9h3oeQMwpXFKi4fgUOeaZUwS-0vgTgVGZwQGa_4yNynNIHANBciRm5WUfbpiakFLp2gTW6Po5NE1zskus2AdOiqxaNfW-xD26_6OPg-iFiOiGHla0Tnu7rnLw93K-XT9nq5fF5ebfKHBe6zxh65i0wy6ivpPaY64qrAlUuHAVbWlUqx8DySkiuS8xLXXglLTJaSAuUz8n57u4mdp8Dpt6MLzusa9tiNyTDJJW8kPw_QsEETMJiJ5zypIiV2cTQ2PhtKJgJpdmiNBMzo7XZojQw-m53PhzjfgWMJrmArUMf4gjP-C78ceEHael-Vw</recordid><startdate>19991001</startdate><enddate>19991001</enddate><creator>Chapman, J.N</creator><creator>Scheinfein, M.R</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope><scope>8BQ</scope><scope>JG9</scope></search><sort><creationdate>19991001</creationdate><title>Transmission electron microscopies of magnetic microstructures</title><author>Chapman, J.N ; Scheinfein, M.R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c369t-2ed2da02a21df79de49f385e846c10aba8b8c20a3f6739be4b95d87ae2157a013</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Domain structure</topic><topic>Lorentz imaging</topic><topic>Transmission electron microscope</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chapman, J.N</creatorcontrib><creatorcontrib>Scheinfein, M.R</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>METADEX</collection><collection>Materials Research Database</collection><jtitle>Journal of magnetism and magnetic materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chapman, J.N</au><au>Scheinfein, M.R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Transmission electron microscopies of magnetic microstructures</atitle><jtitle>Journal of magnetism and magnetic materials</jtitle><date>1999-10-01</date><risdate>1999</risdate><volume>200</volume><issue>1</issue><spage>729</spage><epage>740</epage><pages>729-740</pages><issn>0304-8853</issn><abstract>Since its introduction 40 years ago Lorentz microscopy has been used extensively to study domain structures in magnetic thin films and elements. Here we review the principal imaging modes, with emphasis on those introduced most recently, and discuss their advantages and drawbacks. Special emphasis is given to the development of methodologies which allow the magnetic state of a specimen to be changed in situ and which allow a full quantitative description of the spatial variation of magnetic induction to be extracted. Examples of each are presented. Finally, we discuss areas where further technique development will be beneficial.</abstract><pub>Elsevier B.V</pub><doi>10.1016/S0304-8853(99)00317-0</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0304-8853
ispartof Journal of magnetism and magnetic materials, 1999-10, Vol.200 (1), p.729-740
issn 0304-8853
language eng
recordid cdi_proquest_miscellaneous_27173573
source Elsevier ScienceDirect Journals Complete
subjects Domain structure
Lorentz imaging
Transmission electron microscope
title Transmission electron microscopies of magnetic microstructures
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T16%3A31%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Transmission%20electron%20microscopies%20of%20magnetic%20microstructures&rft.jtitle=Journal%20of%20magnetism%20and%20magnetic%20materials&rft.au=Chapman,%20J.N&rft.date=1999-10-01&rft.volume=200&rft.issue=1&rft.spage=729&rft.epage=740&rft.pages=729-740&rft.issn=0304-8853&rft_id=info:doi/10.1016/S0304-8853(99)00317-0&rft_dat=%3Cproquest_cross%3E27173573%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=27162603&rft_id=info:pmid/&rft_els_id=S0304885399003170&rfr_iscdi=true