Effectiveness of Ultraviolet-C Disinfection on Hospital-Onset Gram-Negative Rod Bloodstream Infection: A Nationwide Stepped-Wedge Time-Series Analysis

The effectiveness of enhanced terminal room cleaning with ultraviolet C (UV-C) disinfection in reducing gram-negative rod (GNR) infections has not been well evaluated. We assessed the association of implementation of UV-C disinfection systems with incidence rates of hospital-onset (HO) GNR bloodstre...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical infectious diseases 2023-01, Vol.76 (2), p.291-298
Hauptverfasser: Goto, Michihiko, Hasegawa, Shinya, Balkenende, Erin C, Clore, Gosia S, Safdar, Nasia, Perencevich, Eli N
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 298
container_issue 2
container_start_page 291
container_title Clinical infectious diseases
container_volume 76
creator Goto, Michihiko
Hasegawa, Shinya
Balkenende, Erin C
Clore, Gosia S
Safdar, Nasia
Perencevich, Eli N
description The effectiveness of enhanced terminal room cleaning with ultraviolet C (UV-C) disinfection in reducing gram-negative rod (GNR) infections has not been well evaluated. We assessed the association of implementation of UV-C disinfection systems with incidence rates of hospital-onset (HO) GNR bloodstream infection (BSI). We obtained information regarding UV-C use and the timing of implementation through a survey of all Veterans Health Administration (VHA) hospitals providing inpatient acute care. Episodes of HO-GNR BSI were identified between January 2010 and December 2018. Bed days of care (BDOC) was used as the denominator. Over-dispersed Poisson regression models were fitted with hospital-specific random intercept, UV-C disinfection use for each month, baseline trend, and seasonality as explanatory variables. Hospitals without UV-C use were also included to the analysis as a nonequivalent concurrent control group. Among 128 VHA hospitals, 120 provided complete survey responses with 40 reporting implementations of UV-C systems. We identified 13 383 episodes of HO-GNR BSI and 24 141 378 BDOC. UV-C use was associated with a lower incidence rate of HO-GNR BSI (incidence rate ratio: 0.813; 95% confidence interval: .656-.969; P = .009). There was wide variability in the effect size of UV-C disinfection use among hospitals. In this large quasi-experimental analysis within the VHA System, enhanced terminal room cleaning with UV-C disinfection was associated with an approximately 19% lower incidence of HO-GNR BSI, with wide variability in effectiveness among hospitals. Further studies are needed to identify the optimal implementation strategy to maximize the effectiveness of UV-C disinfection technology.
doi_str_mv 10.1093/cid/ciac776
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2716088640</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2716088640</sourcerecordid><originalsourceid>FETCH-LOGICAL-c289t-d63d4c6eaebaec483101480ca932eb61fac74c8d45727b8880eb1d341e0897e33</originalsourceid><addsrcrecordid>eNo9kUFP3DAQha2qVaFLT70jHyshUztOHKe3ZaEL0gqk7q44Ro49QUZJnHq8IP5If2-zsFSa0bzDN0-aeYR8E_xc8Er-sN5NbWxZqg_kWBSyZKqoxMdJ80KzXEt9RL4gPnIuhObFZ3Iklcjykqtj8veqbcEm_wQDINLQ0m2XonnyoYPEFvTSox9eiTDQqa4Djj6Zjt0NCIkuo-nZLTyYvQP9HRy96EJwmCKYnt68b_6kc3pr9urZO6DrBOMIjt2DewC68T2wNUQPSOeD6V7Q4wn51JoO4ethzsj219Vmcc1Wd8ubxXzFbKarxJySLrcKDDQG7HSp4CLX3JpKZtAo0U5fya12eVFmZaO15tAIJ3MBXFclSDkj3998xxj-7ABT3Xu00HVmgLDDOiuF4lqrnE_o2RtqY0CM0NZj9L2JL7Xg9T6IegqiPgQx0acH413Tg_vPvn9e_gP6f4dt</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2716088640</pqid></control><display><type>article</type><title>Effectiveness of Ultraviolet-C Disinfection on Hospital-Onset Gram-Negative Rod Bloodstream Infection: A Nationwide Stepped-Wedge Time-Series Analysis</title><source>MEDLINE</source><source>Oxford Academic Journals (OUP)</source><source>Alma/SFX Local Collection</source><source>EZB Electronic Journals Library</source><creator>Goto, Michihiko ; Hasegawa, Shinya ; Balkenende, Erin C ; Clore, Gosia S ; Safdar, Nasia ; Perencevich, Eli N</creator><creatorcontrib>Goto, Michihiko ; Hasegawa, Shinya ; Balkenende, Erin C ; Clore, Gosia S ; Safdar, Nasia ; Perencevich, Eli N ; VA-CDC Practice-Based Research Network</creatorcontrib><description>The effectiveness of enhanced terminal room cleaning with ultraviolet C (UV-C) disinfection in reducing gram-negative rod (GNR) infections has not been well evaluated. We assessed the association of implementation of UV-C disinfection systems with incidence rates of hospital-onset (HO) GNR bloodstream infection (BSI). We obtained information regarding UV-C use and the timing of implementation through a survey of all Veterans Health Administration (VHA) hospitals providing inpatient acute care. Episodes of HO-GNR BSI were identified between January 2010 and December 2018. Bed days of care (BDOC) was used as the denominator. Over-dispersed Poisson regression models were fitted with hospital-specific random intercept, UV-C disinfection use for each month, baseline trend, and seasonality as explanatory variables. Hospitals without UV-C use were also included to the analysis as a nonequivalent concurrent control group. Among 128 VHA hospitals, 120 provided complete survey responses with 40 reporting implementations of UV-C systems. We identified 13 383 episodes of HO-GNR BSI and 24 141 378 BDOC. UV-C use was associated with a lower incidence rate of HO-GNR BSI (incidence rate ratio: 0.813; 95% confidence interval: .656-.969; P = .009). There was wide variability in the effect size of UV-C disinfection use among hospitals. In this large quasi-experimental analysis within the VHA System, enhanced terminal room cleaning with UV-C disinfection was associated with an approximately 19% lower incidence of HO-GNR BSI, with wide variability in effectiveness among hospitals. Further studies are needed to identify the optimal implementation strategy to maximize the effectiveness of UV-C disinfection technology.</description><identifier>ISSN: 1058-4838</identifier><identifier>EISSN: 1537-6591</identifier><identifier>DOI: 10.1093/cid/ciac776</identifier><identifier>PMID: 36124706</identifier><language>eng</language><publisher>United States</publisher><subject>Cross Infection - epidemiology ; Cross Infection - prevention &amp; control ; Disinfection ; Gram-Negative Bacteria ; Hospitals ; Humans ; Sepsis</subject><ispartof>Clinical infectious diseases, 2023-01, Vol.76 (2), p.291-298</ispartof><rights>The Author(s) 2022. Published by Oxford University Press on behalf of Infectious Diseases Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c289t-d63d4c6eaebaec483101480ca932eb61fac74c8d45727b8880eb1d341e0897e33</citedby><cites>FETCH-LOGICAL-c289t-d63d4c6eaebaec483101480ca932eb61fac74c8d45727b8880eb1d341e0897e33</cites><orcidid>0000-0001-6612-5613</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36124706$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Goto, Michihiko</creatorcontrib><creatorcontrib>Hasegawa, Shinya</creatorcontrib><creatorcontrib>Balkenende, Erin C</creatorcontrib><creatorcontrib>Clore, Gosia S</creatorcontrib><creatorcontrib>Safdar, Nasia</creatorcontrib><creatorcontrib>Perencevich, Eli N</creatorcontrib><creatorcontrib>VA-CDC Practice-Based Research Network</creatorcontrib><title>Effectiveness of Ultraviolet-C Disinfection on Hospital-Onset Gram-Negative Rod Bloodstream Infection: A Nationwide Stepped-Wedge Time-Series Analysis</title><title>Clinical infectious diseases</title><addtitle>Clin Infect Dis</addtitle><description>The effectiveness of enhanced terminal room cleaning with ultraviolet C (UV-C) disinfection in reducing gram-negative rod (GNR) infections has not been well evaluated. We assessed the association of implementation of UV-C disinfection systems with incidence rates of hospital-onset (HO) GNR bloodstream infection (BSI). We obtained information regarding UV-C use and the timing of implementation through a survey of all Veterans Health Administration (VHA) hospitals providing inpatient acute care. Episodes of HO-GNR BSI were identified between January 2010 and December 2018. Bed days of care (BDOC) was used as the denominator. Over-dispersed Poisson regression models were fitted with hospital-specific random intercept, UV-C disinfection use for each month, baseline trend, and seasonality as explanatory variables. Hospitals without UV-C use were also included to the analysis as a nonequivalent concurrent control group. Among 128 VHA hospitals, 120 provided complete survey responses with 40 reporting implementations of UV-C systems. We identified 13 383 episodes of HO-GNR BSI and 24 141 378 BDOC. UV-C use was associated with a lower incidence rate of HO-GNR BSI (incidence rate ratio: 0.813; 95% confidence interval: .656-.969; P = .009). There was wide variability in the effect size of UV-C disinfection use among hospitals. In this large quasi-experimental analysis within the VHA System, enhanced terminal room cleaning with UV-C disinfection was associated with an approximately 19% lower incidence of HO-GNR BSI, with wide variability in effectiveness among hospitals. Further studies are needed to identify the optimal implementation strategy to maximize the effectiveness of UV-C disinfection technology.</description><subject>Cross Infection - epidemiology</subject><subject>Cross Infection - prevention &amp; control</subject><subject>Disinfection</subject><subject>Gram-Negative Bacteria</subject><subject>Hospitals</subject><subject>Humans</subject><subject>Sepsis</subject><issn>1058-4838</issn><issn>1537-6591</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kUFP3DAQha2qVaFLT70jHyshUztOHKe3ZaEL0gqk7q44Ro49QUZJnHq8IP5If2-zsFSa0bzDN0-aeYR8E_xc8Er-sN5NbWxZqg_kWBSyZKqoxMdJ80KzXEt9RL4gPnIuhObFZ3Iklcjykqtj8veqbcEm_wQDINLQ0m2XonnyoYPEFvTSox9eiTDQqa4Djj6Zjt0NCIkuo-nZLTyYvQP9HRy96EJwmCKYnt68b_6kc3pr9urZO6DrBOMIjt2DewC68T2wNUQPSOeD6V7Q4wn51JoO4ethzsj219Vmcc1Wd8ubxXzFbKarxJySLrcKDDQG7HSp4CLX3JpKZtAo0U5fya12eVFmZaO15tAIJ3MBXFclSDkj3998xxj-7ABT3Xu00HVmgLDDOiuF4lqrnE_o2RtqY0CM0NZj9L2JL7Xg9T6IegqiPgQx0acH413Tg_vPvn9e_gP6f4dt</recordid><startdate>20230113</startdate><enddate>20230113</enddate><creator>Goto, Michihiko</creator><creator>Hasegawa, Shinya</creator><creator>Balkenende, Erin C</creator><creator>Clore, Gosia S</creator><creator>Safdar, Nasia</creator><creator>Perencevich, Eli N</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-6612-5613</orcidid></search><sort><creationdate>20230113</creationdate><title>Effectiveness of Ultraviolet-C Disinfection on Hospital-Onset Gram-Negative Rod Bloodstream Infection: A Nationwide Stepped-Wedge Time-Series Analysis</title><author>Goto, Michihiko ; Hasegawa, Shinya ; Balkenende, Erin C ; Clore, Gosia S ; Safdar, Nasia ; Perencevich, Eli N</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c289t-d63d4c6eaebaec483101480ca932eb61fac74c8d45727b8880eb1d341e0897e33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Cross Infection - epidemiology</topic><topic>Cross Infection - prevention &amp; control</topic><topic>Disinfection</topic><topic>Gram-Negative Bacteria</topic><topic>Hospitals</topic><topic>Humans</topic><topic>Sepsis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Goto, Michihiko</creatorcontrib><creatorcontrib>Hasegawa, Shinya</creatorcontrib><creatorcontrib>Balkenende, Erin C</creatorcontrib><creatorcontrib>Clore, Gosia S</creatorcontrib><creatorcontrib>Safdar, Nasia</creatorcontrib><creatorcontrib>Perencevich, Eli N</creatorcontrib><creatorcontrib>VA-CDC Practice-Based Research Network</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical infectious diseases</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Goto, Michihiko</au><au>Hasegawa, Shinya</au><au>Balkenende, Erin C</au><au>Clore, Gosia S</au><au>Safdar, Nasia</au><au>Perencevich, Eli N</au><aucorp>VA-CDC Practice-Based Research Network</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effectiveness of Ultraviolet-C Disinfection on Hospital-Onset Gram-Negative Rod Bloodstream Infection: A Nationwide Stepped-Wedge Time-Series Analysis</atitle><jtitle>Clinical infectious diseases</jtitle><addtitle>Clin Infect Dis</addtitle><date>2023-01-13</date><risdate>2023</risdate><volume>76</volume><issue>2</issue><spage>291</spage><epage>298</epage><pages>291-298</pages><issn>1058-4838</issn><eissn>1537-6591</eissn><abstract>The effectiveness of enhanced terminal room cleaning with ultraviolet C (UV-C) disinfection in reducing gram-negative rod (GNR) infections has not been well evaluated. We assessed the association of implementation of UV-C disinfection systems with incidence rates of hospital-onset (HO) GNR bloodstream infection (BSI). We obtained information regarding UV-C use and the timing of implementation through a survey of all Veterans Health Administration (VHA) hospitals providing inpatient acute care. Episodes of HO-GNR BSI were identified between January 2010 and December 2018. Bed days of care (BDOC) was used as the denominator. Over-dispersed Poisson regression models were fitted with hospital-specific random intercept, UV-C disinfection use for each month, baseline trend, and seasonality as explanatory variables. Hospitals without UV-C use were also included to the analysis as a nonequivalent concurrent control group. Among 128 VHA hospitals, 120 provided complete survey responses with 40 reporting implementations of UV-C systems. We identified 13 383 episodes of HO-GNR BSI and 24 141 378 BDOC. UV-C use was associated with a lower incidence rate of HO-GNR BSI (incidence rate ratio: 0.813; 95% confidence interval: .656-.969; P = .009). There was wide variability in the effect size of UV-C disinfection use among hospitals. In this large quasi-experimental analysis within the VHA System, enhanced terminal room cleaning with UV-C disinfection was associated with an approximately 19% lower incidence of HO-GNR BSI, with wide variability in effectiveness among hospitals. Further studies are needed to identify the optimal implementation strategy to maximize the effectiveness of UV-C disinfection technology.</abstract><cop>United States</cop><pmid>36124706</pmid><doi>10.1093/cid/ciac776</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0001-6612-5613</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1058-4838
ispartof Clinical infectious diseases, 2023-01, Vol.76 (2), p.291-298
issn 1058-4838
1537-6591
language eng
recordid cdi_proquest_miscellaneous_2716088640
source MEDLINE; Oxford Academic Journals (OUP); Alma/SFX Local Collection; EZB Electronic Journals Library
subjects Cross Infection - epidemiology
Cross Infection - prevention & control
Disinfection
Gram-Negative Bacteria
Hospitals
Humans
Sepsis
title Effectiveness of Ultraviolet-C Disinfection on Hospital-Onset Gram-Negative Rod Bloodstream Infection: A Nationwide Stepped-Wedge Time-Series Analysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T18%3A43%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effectiveness%20of%20Ultraviolet-C%20Disinfection%20on%20Hospital-Onset%20Gram-Negative%20Rod%20Bloodstream%20Infection:%20A%20Nationwide%20Stepped-Wedge%20Time-Series%20Analysis&rft.jtitle=Clinical%20infectious%20diseases&rft.au=Goto,%20Michihiko&rft.aucorp=VA-CDC%20Practice-Based%20Research%20Network&rft.date=2023-01-13&rft.volume=76&rft.issue=2&rft.spage=291&rft.epage=298&rft.pages=291-298&rft.issn=1058-4838&rft.eissn=1537-6591&rft_id=info:doi/10.1093/cid/ciac776&rft_dat=%3Cproquest_cross%3E2716088640%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2716088640&rft_id=info:pmid/36124706&rfr_iscdi=true