Comparison of the Safety and Efficacy of Three-Dimensional Guiding Templates and Free Hand Technique for Cervical Pedicle Screw Fixation: A Retrospective Study

Aim. To compare the safety and efficacy of computed tomography (CT)-assisted three-dimensional guiding templates (3DGTs) and free-hand (FH) technique for posterior cervical pedicle screw fixation in cervical spondylotic myelopathy (CSM) treatment. Methods. Thirty-five patients (216 screws) with CSM...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgical innovation 2022-10, Vol.29 (5), p.652-661
Hauptverfasser: He, Yan-xing, Shang, Qi-song, Feng, Lin, Li, Hai-bo, Han, Long, Zhou, Dong, Jiang, Yu-qing
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 661
container_issue 5
container_start_page 652
container_title Surgical innovation
container_volume 29
creator He, Yan-xing
Shang, Qi-song
Feng, Lin
Li, Hai-bo
Han, Long
Zhou, Dong
Jiang, Yu-qing
description Aim. To compare the safety and efficacy of computed tomography (CT)-assisted three-dimensional guiding templates (3DGTs) and free-hand (FH) technique for posterior cervical pedicle screw fixation in cervical spondylotic myelopathy (CSM) treatment. Methods. Thirty-five patients (216 screws) with CSM and developmental cervical stenosis were randomly divided into groups A (FH) and B (3DGTs). All patients underwent modified posterior surgery with cervical pedicle screw insertion (C1-7). Preoperative, postoperative, and intergroup comparisons of efficacy were evaluated using the visual analog scale (VAS), Japanese Orthopaedic Association (JOA), and Short Form 12 (SF-12) scores and JOA score improvement rate. Incidence of intra- and postoperative complications was analyzed. Postoperative cervical spine CT was performed to evaluate (i) the pedicle screws’ deviation angle from the optimal path (sagittal deviation, α; coronal deviation angle, β), screw insertion point’s deviation distance (d), and screw accuracy and (ii) the deviation angle and distance of screw entrance point of pedicle screws from the optimal channel. Results. All patients successfully completed the procedures. Groups A and B did not significantly differ in age, sex ratio, body mass index, operative time, or intraoperative blood loss amount. Postoperative VAS, JOA, and SF-12 scores improved in both groups. VAS, JOA, or SF-12 scores did not significantly differ between the 2 groups. The α, β, and d scores were lower in group B, but accuracy was higher in group B. Conclusions. 3DGTs and FH technique show comparable outcomes with respect to neurological improvement and safety.
doi_str_mv 10.1177/15533506221127381
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2715440198</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_15533506221127381</sage_id><sourcerecordid>2715440198</sourcerecordid><originalsourceid>FETCH-LOGICAL-c269t-5a14af2ee420edf1698c93ac908270c77063b4058606b7b9830d87db3f2ef7f63</originalsourceid><addsrcrecordid>eNp9kcFOwzAMhiMEEmPwANxy5NKRNE3TcpvGBkhIIBjnKksdFtQ2JUmBPQ2vSsYQFyROtvz7-23ZCJ1SMqFUiHPKOWOc5GlKaSpYQffQaFtLGKfZ_m9O8kN05P0LIRmnhI_Q58y2vXTG2w5bjcMa8KPUEDZYdjWea22UVJuttFw7gOTStNB5YzvZ4KvB1KZ7xkto-0YG8N_MIrbh6222BLXuzOsAWFuHZ-DeolmD76E2qolzlIN3vDAfMkS_CzzFDxCc9T2oYN6iHoZ6c4wOtGw8nPzEMXpazJez6-T27upmNr1NVJqXIeGSZlKnAFlKoNY0LwtVMqlKUqSCKCFIzlYZ4UVO8pVYlQUjdSHqFYuMFjpnY3S28-2djRv7ULXGK2ga2YEdfJUKyrOM0EiOEd21qrisd6Cr3plWuk1FSbV9RvXnGZGZ7Bgvn6F6sYOLB_T_AF8HC4qa</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2715440198</pqid></control><display><type>article</type><title>Comparison of the Safety and Efficacy of Three-Dimensional Guiding Templates and Free Hand Technique for Cervical Pedicle Screw Fixation: A Retrospective Study</title><source>Access via SAGE</source><source>Alma/SFX Local Collection</source><creator>He, Yan-xing ; Shang, Qi-song ; Feng, Lin ; Li, Hai-bo ; Han, Long ; Zhou, Dong ; Jiang, Yu-qing</creator><creatorcontrib>He, Yan-xing ; Shang, Qi-song ; Feng, Lin ; Li, Hai-bo ; Han, Long ; Zhou, Dong ; Jiang, Yu-qing</creatorcontrib><description>Aim. To compare the safety and efficacy of computed tomography (CT)-assisted three-dimensional guiding templates (3DGTs) and free-hand (FH) technique for posterior cervical pedicle screw fixation in cervical spondylotic myelopathy (CSM) treatment. Methods. Thirty-five patients (216 screws) with CSM and developmental cervical stenosis were randomly divided into groups A (FH) and B (3DGTs). All patients underwent modified posterior surgery with cervical pedicle screw insertion (C1-7). Preoperative, postoperative, and intergroup comparisons of efficacy were evaluated using the visual analog scale (VAS), Japanese Orthopaedic Association (JOA), and Short Form 12 (SF-12) scores and JOA score improvement rate. Incidence of intra- and postoperative complications was analyzed. Postoperative cervical spine CT was performed to evaluate (i) the pedicle screws’ deviation angle from the optimal path (sagittal deviation, α; coronal deviation angle, β), screw insertion point’s deviation distance (d), and screw accuracy and (ii) the deviation angle and distance of screw entrance point of pedicle screws from the optimal channel. Results. All patients successfully completed the procedures. Groups A and B did not significantly differ in age, sex ratio, body mass index, operative time, or intraoperative blood loss amount. Postoperative VAS, JOA, and SF-12 scores improved in both groups. VAS, JOA, or SF-12 scores did not significantly differ between the 2 groups. The α, β, and d scores were lower in group B, but accuracy was higher in group B. Conclusions. 3DGTs and FH technique show comparable outcomes with respect to neurological improvement and safety.</description><identifier>ISSN: 1553-3506</identifier><identifier>EISSN: 1553-3514</identifier><identifier>DOI: 10.1177/15533506221127381</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><ispartof>Surgical innovation, 2022-10, Vol.29 (5), p.652-661</ispartof><rights>The Author(s) 2022</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c269t-5a14af2ee420edf1698c93ac908270c77063b4058606b7b9830d87db3f2ef7f63</cites><orcidid>0000-0002-4202-3038</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/15533506221127381$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/15533506221127381$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids></links><search><creatorcontrib>He, Yan-xing</creatorcontrib><creatorcontrib>Shang, Qi-song</creatorcontrib><creatorcontrib>Feng, Lin</creatorcontrib><creatorcontrib>Li, Hai-bo</creatorcontrib><creatorcontrib>Han, Long</creatorcontrib><creatorcontrib>Zhou, Dong</creatorcontrib><creatorcontrib>Jiang, Yu-qing</creatorcontrib><title>Comparison of the Safety and Efficacy of Three-Dimensional Guiding Templates and Free Hand Technique for Cervical Pedicle Screw Fixation: A Retrospective Study</title><title>Surgical innovation</title><addtitle>Surg Innov</addtitle><description>Aim. To compare the safety and efficacy of computed tomography (CT)-assisted three-dimensional guiding templates (3DGTs) and free-hand (FH) technique for posterior cervical pedicle screw fixation in cervical spondylotic myelopathy (CSM) treatment. Methods. Thirty-five patients (216 screws) with CSM and developmental cervical stenosis were randomly divided into groups A (FH) and B (3DGTs). All patients underwent modified posterior surgery with cervical pedicle screw insertion (C1-7). Preoperative, postoperative, and intergroup comparisons of efficacy were evaluated using the visual analog scale (VAS), Japanese Orthopaedic Association (JOA), and Short Form 12 (SF-12) scores and JOA score improvement rate. Incidence of intra- and postoperative complications was analyzed. Postoperative cervical spine CT was performed to evaluate (i) the pedicle screws’ deviation angle from the optimal path (sagittal deviation, α; coronal deviation angle, β), screw insertion point’s deviation distance (d), and screw accuracy and (ii) the deviation angle and distance of screw entrance point of pedicle screws from the optimal channel. Results. All patients successfully completed the procedures. Groups A and B did not significantly differ in age, sex ratio, body mass index, operative time, or intraoperative blood loss amount. Postoperative VAS, JOA, and SF-12 scores improved in both groups. VAS, JOA, or SF-12 scores did not significantly differ between the 2 groups. The α, β, and d scores were lower in group B, but accuracy was higher in group B. Conclusions. 3DGTs and FH technique show comparable outcomes with respect to neurological improvement and safety.</description><issn>1553-3506</issn><issn>1553-3514</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kcFOwzAMhiMEEmPwANxy5NKRNE3TcpvGBkhIIBjnKksdFtQ2JUmBPQ2vSsYQFyROtvz7-23ZCJ1SMqFUiHPKOWOc5GlKaSpYQffQaFtLGKfZ_m9O8kN05P0LIRmnhI_Q58y2vXTG2w5bjcMa8KPUEDZYdjWea22UVJuttFw7gOTStNB5YzvZ4KvB1KZ7xkto-0YG8N_MIrbh6222BLXuzOsAWFuHZ-DeolmD76E2qolzlIN3vDAfMkS_CzzFDxCc9T2oYN6iHoZ6c4wOtGw8nPzEMXpazJez6-T27upmNr1NVJqXIeGSZlKnAFlKoNY0LwtVMqlKUqSCKCFIzlYZ4UVO8pVYlQUjdSHqFYuMFjpnY3S28-2djRv7ULXGK2ga2YEdfJUKyrOM0EiOEd21qrisd6Cr3plWuk1FSbV9RvXnGZGZ7Bgvn6F6sYOLB_T_AF8HC4qa</recordid><startdate>202210</startdate><enddate>202210</enddate><creator>He, Yan-xing</creator><creator>Shang, Qi-song</creator><creator>Feng, Lin</creator><creator>Li, Hai-bo</creator><creator>Han, Long</creator><creator>Zhou, Dong</creator><creator>Jiang, Yu-qing</creator><general>SAGE Publications</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-4202-3038</orcidid></search><sort><creationdate>202210</creationdate><title>Comparison of the Safety and Efficacy of Three-Dimensional Guiding Templates and Free Hand Technique for Cervical Pedicle Screw Fixation: A Retrospective Study</title><author>He, Yan-xing ; Shang, Qi-song ; Feng, Lin ; Li, Hai-bo ; Han, Long ; Zhou, Dong ; Jiang, Yu-qing</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c269t-5a14af2ee420edf1698c93ac908270c77063b4058606b7b9830d87db3f2ef7f63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>He, Yan-xing</creatorcontrib><creatorcontrib>Shang, Qi-song</creatorcontrib><creatorcontrib>Feng, Lin</creatorcontrib><creatorcontrib>Li, Hai-bo</creatorcontrib><creatorcontrib>Han, Long</creatorcontrib><creatorcontrib>Zhou, Dong</creatorcontrib><creatorcontrib>Jiang, Yu-qing</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Surgical innovation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>He, Yan-xing</au><au>Shang, Qi-song</au><au>Feng, Lin</au><au>Li, Hai-bo</au><au>Han, Long</au><au>Zhou, Dong</au><au>Jiang, Yu-qing</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of the Safety and Efficacy of Three-Dimensional Guiding Templates and Free Hand Technique for Cervical Pedicle Screw Fixation: A Retrospective Study</atitle><jtitle>Surgical innovation</jtitle><addtitle>Surg Innov</addtitle><date>2022-10</date><risdate>2022</risdate><volume>29</volume><issue>5</issue><spage>652</spage><epage>661</epage><pages>652-661</pages><issn>1553-3506</issn><eissn>1553-3514</eissn><abstract>Aim. To compare the safety and efficacy of computed tomography (CT)-assisted three-dimensional guiding templates (3DGTs) and free-hand (FH) technique for posterior cervical pedicle screw fixation in cervical spondylotic myelopathy (CSM) treatment. Methods. Thirty-five patients (216 screws) with CSM and developmental cervical stenosis were randomly divided into groups A (FH) and B (3DGTs). All patients underwent modified posterior surgery with cervical pedicle screw insertion (C1-7). Preoperative, postoperative, and intergroup comparisons of efficacy were evaluated using the visual analog scale (VAS), Japanese Orthopaedic Association (JOA), and Short Form 12 (SF-12) scores and JOA score improvement rate. Incidence of intra- and postoperative complications was analyzed. Postoperative cervical spine CT was performed to evaluate (i) the pedicle screws’ deviation angle from the optimal path (sagittal deviation, α; coronal deviation angle, β), screw insertion point’s deviation distance (d), and screw accuracy and (ii) the deviation angle and distance of screw entrance point of pedicle screws from the optimal channel. Results. All patients successfully completed the procedures. Groups A and B did not significantly differ in age, sex ratio, body mass index, operative time, or intraoperative blood loss amount. Postoperative VAS, JOA, and SF-12 scores improved in both groups. VAS, JOA, or SF-12 scores did not significantly differ between the 2 groups. The α, β, and d scores were lower in group B, but accuracy was higher in group B. Conclusions. 3DGTs and FH technique show comparable outcomes with respect to neurological improvement and safety.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><doi>10.1177/15533506221127381</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0002-4202-3038</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1553-3506
ispartof Surgical innovation, 2022-10, Vol.29 (5), p.652-661
issn 1553-3506
1553-3514
language eng
recordid cdi_proquest_miscellaneous_2715440198
source Access via SAGE; Alma/SFX Local Collection
title Comparison of the Safety and Efficacy of Three-Dimensional Guiding Templates and Free Hand Technique for Cervical Pedicle Screw Fixation: A Retrospective Study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T18%3A43%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20the%20Safety%20and%20Efficacy%20of%20Three-Dimensional%20Guiding%20Templates%20and%20Free%20Hand%20Technique%20for%20Cervical%20Pedicle%20Screw%20Fixation:%20A%20Retrospective%20Study&rft.jtitle=Surgical%20innovation&rft.au=He,%20Yan-xing&rft.date=2022-10&rft.volume=29&rft.issue=5&rft.spage=652&rft.epage=661&rft.pages=652-661&rft.issn=1553-3506&rft.eissn=1553-3514&rft_id=info:doi/10.1177/15533506221127381&rft_dat=%3Cproquest_cross%3E2715440198%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2715440198&rft_id=info:pmid/&rft_sage_id=10.1177_15533506221127381&rfr_iscdi=true