Performance of Radiologists and Radiographers in Double Reading Mammograms: The UK National Health Service Breast Screening Program

Background Double reading can be used in screening mammography, but it is labor intensive. There is limited evidence on whether trained radiographers (ie, technologists) may be used to provide double reading. Purpose To compare the performance of radiologists and radiographers double reading screeni...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiology 2023-01, Vol.306 (1), p.102-109
Hauptverfasser: Chen, Yan, James, Jonathan J, Michalopoulou, Eleni, Darker, Iain T, Jenkins, Jacquie
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 109
container_issue 1
container_start_page 102
container_title Radiology
container_volume 306
creator Chen, Yan
James, Jonathan J
Michalopoulou, Eleni
Darker, Iain T
Jenkins, Jacquie
description Background Double reading can be used in screening mammography, but it is labor intensive. There is limited evidence on whether trained radiographers (ie, technologists) may be used to provide double reading. Purpose To compare the performance of radiologists and radiographers double reading screening mammograms, considering reader experience level. Materials and Methods In this retrospective study, performance and experience data were obtained for radiologists and radiographer readers of all screening mammograms in England from April 2015 to March 2016. Cancer detection rate (CDR), recall rate (RR), and positive predictive value (PPV) of recall based on biopsy-proven findings were calculated for first readers. Performance metrics were analyzed according to reader professional group and years of reading experience using the analysis of variance test. values less than .05 were considered to indicate statistically significant difference. Results During the study period, 401 readers (224 radiologists and 177 radiographers) double read 1 404 395 screening digital mammograms. There was no difference in CDR between radiologist and radiographer readers (mean, 7.84 vs 7.53 per 1000 examinations, respectively; = .08) and no difference for readers with more than 10 years of experience compared with 5 years or fewer years of experience, regardless of professional group (mean, 7.75 vs 7.71 per 1000 examinations respectively, = .87). No difference in the mean RR was observed between radiologists and radiographer readers (5.0% vs 5.2%, respectively, = .63). A lower RR was seen for readers with more than 10 years of experience compared with 5 years or fewer, regardless of professional group (mean, 4.8% vs 5.8%, respectively; = .001). No variation in PPV was observed between them ( = .42), with PPV values of 17.1% for radiologists versus 16.1% for radiographers. A higher PPV was seen for readers with more than 10 years of experience compared with 5 years or less, regardless of professional group (mean, 17.5% and 14.9%, respectively; = .02). Conclusion No difference in performance was observed between radiographers and radiologists reading screening mammograms in a program that used double reading. Published under a CC BY 4.0 license See also the editorial by Hooley and Durand in this issue.
doi_str_mv 10.1148/radiol.212951
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2714064034</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2714064034</sourcerecordid><originalsourceid>FETCH-LOGICAL-c293t-10af27923a5d0774d52df2c884780a282f81dfa335ed522cbcba93d82665253b3</originalsourceid><addsrcrecordid>eNo9kDlPw0AQhVcIRMJR0qItaRz2tNd0EE5xiqO2xutxYmR7w66DRM0fx8GBaqR53_uKR8gBZxPOlTn2UFSungguUs03yJhrkURccr1JxoxJGRnF0xHZCeGdMa60SbbJSMYsNbGSY_L9hL50voHWInUlff7VuVkVukChLYbHzMNijj7QqqXnbpnXSJ-xD9oZvYemWeVNOKGvc6Rvt_QBusq1UNNrhLqb0xf0n1WvP_MIoaMv1iO2q-6T_23uka0S6oD767tL3i4vXqfX0d3j1c309C6yIpVdxBmUIkmFBF2wJFGFFkUprDEqMQyEEaXhRQlSauwjYXObQyoLI-JYCy1zuUuOBu_Cu48lhi5rqmCxrqFFtwyZSLhisWJS9Wg0oNa7EDyW2cJXDfivjLNstXs27J4Nu_f84Vq9zBss_um_oeUPdEmAEw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2714064034</pqid></control><display><type>article</type><title>Performance of Radiologists and Radiographers in Double Reading Mammograms: The UK National Health Service Breast Screening Program</title><source>MEDLINE</source><source>Radiological Society of North America</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Chen, Yan ; James, Jonathan J ; Michalopoulou, Eleni ; Darker, Iain T ; Jenkins, Jacquie</creator><creatorcontrib>Chen, Yan ; James, Jonathan J ; Michalopoulou, Eleni ; Darker, Iain T ; Jenkins, Jacquie</creatorcontrib><description>Background Double reading can be used in screening mammography, but it is labor intensive. There is limited evidence on whether trained radiographers (ie, technologists) may be used to provide double reading. Purpose To compare the performance of radiologists and radiographers double reading screening mammograms, considering reader experience level. Materials and Methods In this retrospective study, performance and experience data were obtained for radiologists and radiographer readers of all screening mammograms in England from April 2015 to March 2016. Cancer detection rate (CDR), recall rate (RR), and positive predictive value (PPV) of recall based on biopsy-proven findings were calculated for first readers. Performance metrics were analyzed according to reader professional group and years of reading experience using the analysis of variance test. values less than .05 were considered to indicate statistically significant difference. Results During the study period, 401 readers (224 radiologists and 177 radiographers) double read 1 404 395 screening digital mammograms. There was no difference in CDR between radiologist and radiographer readers (mean, 7.84 vs 7.53 per 1000 examinations, respectively; = .08) and no difference for readers with more than 10 years of experience compared with 5 years or fewer years of experience, regardless of professional group (mean, 7.75 vs 7.71 per 1000 examinations respectively, = .87). No difference in the mean RR was observed between radiologists and radiographer readers (5.0% vs 5.2%, respectively, = .63). A lower RR was seen for readers with more than 10 years of experience compared with 5 years or fewer, regardless of professional group (mean, 4.8% vs 5.8%, respectively; = .001). No variation in PPV was observed between them ( = .42), with PPV values of 17.1% for radiologists versus 16.1% for radiographers. A higher PPV was seen for readers with more than 10 years of experience compared with 5 years or less, regardless of professional group (mean, 17.5% and 14.9%, respectively; = .02). Conclusion No difference in performance was observed between radiographers and radiologists reading screening mammograms in a program that used double reading. Published under a CC BY 4.0 license See also the editorial by Hooley and Durand in this issue.</description><identifier>ISSN: 0033-8419</identifier><identifier>EISSN: 1527-1315</identifier><identifier>DOI: 10.1148/radiol.212951</identifier><identifier>PMID: 36098643</identifier><language>eng</language><publisher>United States</publisher><subject>Breast Neoplasms ; Early Detection of Cancer ; England ; Female ; Humans ; Mammography - methods ; Mass Screening - methods ; Radiologists ; Retrospective Studies ; Sensitivity and Specificity ; State Medicine</subject><ispartof>Radiology, 2023-01, Vol.306 (1), p.102-109</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c293t-10af27923a5d0774d52df2c884780a282f81dfa335ed522cbcba93d82665253b3</citedby><cites>FETCH-LOGICAL-c293t-10af27923a5d0774d52df2c884780a282f81dfa335ed522cbcba93d82665253b3</cites><orcidid>0000-0002-5757-3139 ; 0000-0002-3552-7908 ; 0000-0002-4337-8543 ; 0000-0003-3107-7898</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4002,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36098643$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chen, Yan</creatorcontrib><creatorcontrib>James, Jonathan J</creatorcontrib><creatorcontrib>Michalopoulou, Eleni</creatorcontrib><creatorcontrib>Darker, Iain T</creatorcontrib><creatorcontrib>Jenkins, Jacquie</creatorcontrib><title>Performance of Radiologists and Radiographers in Double Reading Mammograms: The UK National Health Service Breast Screening Program</title><title>Radiology</title><addtitle>Radiology</addtitle><description>Background Double reading can be used in screening mammography, but it is labor intensive. There is limited evidence on whether trained radiographers (ie, technologists) may be used to provide double reading. Purpose To compare the performance of radiologists and radiographers double reading screening mammograms, considering reader experience level. Materials and Methods In this retrospective study, performance and experience data were obtained for radiologists and radiographer readers of all screening mammograms in England from April 2015 to March 2016. Cancer detection rate (CDR), recall rate (RR), and positive predictive value (PPV) of recall based on biopsy-proven findings were calculated for first readers. Performance metrics were analyzed according to reader professional group and years of reading experience using the analysis of variance test. values less than .05 were considered to indicate statistically significant difference. Results During the study period, 401 readers (224 radiologists and 177 radiographers) double read 1 404 395 screening digital mammograms. There was no difference in CDR between radiologist and radiographer readers (mean, 7.84 vs 7.53 per 1000 examinations, respectively; = .08) and no difference for readers with more than 10 years of experience compared with 5 years or fewer years of experience, regardless of professional group (mean, 7.75 vs 7.71 per 1000 examinations respectively, = .87). No difference in the mean RR was observed between radiologists and radiographer readers (5.0% vs 5.2%, respectively, = .63). A lower RR was seen for readers with more than 10 years of experience compared with 5 years or fewer, regardless of professional group (mean, 4.8% vs 5.8%, respectively; = .001). No variation in PPV was observed between them ( = .42), with PPV values of 17.1% for radiologists versus 16.1% for radiographers. A higher PPV was seen for readers with more than 10 years of experience compared with 5 years or less, regardless of professional group (mean, 17.5% and 14.9%, respectively; = .02). Conclusion No difference in performance was observed between radiographers and radiologists reading screening mammograms in a program that used double reading. Published under a CC BY 4.0 license See also the editorial by Hooley and Durand in this issue.</description><subject>Breast Neoplasms</subject><subject>Early Detection of Cancer</subject><subject>England</subject><subject>Female</subject><subject>Humans</subject><subject>Mammography - methods</subject><subject>Mass Screening - methods</subject><subject>Radiologists</subject><subject>Retrospective Studies</subject><subject>Sensitivity and Specificity</subject><subject>State Medicine</subject><issn>0033-8419</issn><issn>1527-1315</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kDlPw0AQhVcIRMJR0qItaRz2tNd0EE5xiqO2xutxYmR7w66DRM0fx8GBaqR53_uKR8gBZxPOlTn2UFSungguUs03yJhrkURccr1JxoxJGRnF0xHZCeGdMa60SbbJSMYsNbGSY_L9hL50voHWInUlff7VuVkVukChLYbHzMNijj7QqqXnbpnXSJ-xD9oZvYemWeVNOKGvc6Rvt_QBusq1UNNrhLqb0xf0n1WvP_MIoaMv1iO2q-6T_23uka0S6oD767tL3i4vXqfX0d3j1c309C6yIpVdxBmUIkmFBF2wJFGFFkUprDEqMQyEEaXhRQlSauwjYXObQyoLI-JYCy1zuUuOBu_Cu48lhi5rqmCxrqFFtwyZSLhisWJS9Wg0oNa7EDyW2cJXDfivjLNstXs27J4Nu_f84Vq9zBss_um_oeUPdEmAEw</recordid><startdate>202301</startdate><enddate>202301</enddate><creator>Chen, Yan</creator><creator>James, Jonathan J</creator><creator>Michalopoulou, Eleni</creator><creator>Darker, Iain T</creator><creator>Jenkins, Jacquie</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-5757-3139</orcidid><orcidid>https://orcid.org/0000-0002-3552-7908</orcidid><orcidid>https://orcid.org/0000-0002-4337-8543</orcidid><orcidid>https://orcid.org/0000-0003-3107-7898</orcidid></search><sort><creationdate>202301</creationdate><title>Performance of Radiologists and Radiographers in Double Reading Mammograms: The UK National Health Service Breast Screening Program</title><author>Chen, Yan ; James, Jonathan J ; Michalopoulou, Eleni ; Darker, Iain T ; Jenkins, Jacquie</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c293t-10af27923a5d0774d52df2c884780a282f81dfa335ed522cbcba93d82665253b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Breast Neoplasms</topic><topic>Early Detection of Cancer</topic><topic>England</topic><topic>Female</topic><topic>Humans</topic><topic>Mammography - methods</topic><topic>Mass Screening - methods</topic><topic>Radiologists</topic><topic>Retrospective Studies</topic><topic>Sensitivity and Specificity</topic><topic>State Medicine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chen, Yan</creatorcontrib><creatorcontrib>James, Jonathan J</creatorcontrib><creatorcontrib>Michalopoulou, Eleni</creatorcontrib><creatorcontrib>Darker, Iain T</creatorcontrib><creatorcontrib>Jenkins, Jacquie</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chen, Yan</au><au>James, Jonathan J</au><au>Michalopoulou, Eleni</au><au>Darker, Iain T</au><au>Jenkins, Jacquie</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Performance of Radiologists and Radiographers in Double Reading Mammograms: The UK National Health Service Breast Screening Program</atitle><jtitle>Radiology</jtitle><addtitle>Radiology</addtitle><date>2023-01</date><risdate>2023</risdate><volume>306</volume><issue>1</issue><spage>102</spage><epage>109</epage><pages>102-109</pages><issn>0033-8419</issn><eissn>1527-1315</eissn><abstract>Background Double reading can be used in screening mammography, but it is labor intensive. There is limited evidence on whether trained radiographers (ie, technologists) may be used to provide double reading. Purpose To compare the performance of radiologists and radiographers double reading screening mammograms, considering reader experience level. Materials and Methods In this retrospective study, performance and experience data were obtained for radiologists and radiographer readers of all screening mammograms in England from April 2015 to March 2016. Cancer detection rate (CDR), recall rate (RR), and positive predictive value (PPV) of recall based on biopsy-proven findings were calculated for first readers. Performance metrics were analyzed according to reader professional group and years of reading experience using the analysis of variance test. values less than .05 were considered to indicate statistically significant difference. Results During the study period, 401 readers (224 radiologists and 177 radiographers) double read 1 404 395 screening digital mammograms. There was no difference in CDR between radiologist and radiographer readers (mean, 7.84 vs 7.53 per 1000 examinations, respectively; = .08) and no difference for readers with more than 10 years of experience compared with 5 years or fewer years of experience, regardless of professional group (mean, 7.75 vs 7.71 per 1000 examinations respectively, = .87). No difference in the mean RR was observed between radiologists and radiographer readers (5.0% vs 5.2%, respectively, = .63). A lower RR was seen for readers with more than 10 years of experience compared with 5 years or fewer, regardless of professional group (mean, 4.8% vs 5.8%, respectively; = .001). No variation in PPV was observed between them ( = .42), with PPV values of 17.1% for radiologists versus 16.1% for radiographers. A higher PPV was seen for readers with more than 10 years of experience compared with 5 years or less, regardless of professional group (mean, 17.5% and 14.9%, respectively; = .02). Conclusion No difference in performance was observed between radiographers and radiologists reading screening mammograms in a program that used double reading. Published under a CC BY 4.0 license See also the editorial by Hooley and Durand in this issue.</abstract><cop>United States</cop><pmid>36098643</pmid><doi>10.1148/radiol.212951</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-5757-3139</orcidid><orcidid>https://orcid.org/0000-0002-3552-7908</orcidid><orcidid>https://orcid.org/0000-0002-4337-8543</orcidid><orcidid>https://orcid.org/0000-0003-3107-7898</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0033-8419
ispartof Radiology, 2023-01, Vol.306 (1), p.102-109
issn 0033-8419
1527-1315
language eng
recordid cdi_proquest_miscellaneous_2714064034
source MEDLINE; Radiological Society of North America; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Breast Neoplasms
Early Detection of Cancer
England
Female
Humans
Mammography - methods
Mass Screening - methods
Radiologists
Retrospective Studies
Sensitivity and Specificity
State Medicine
title Performance of Radiologists and Radiographers in Double Reading Mammograms: The UK National Health Service Breast Screening Program
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T22%3A35%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Performance%20of%20Radiologists%20and%20Radiographers%20in%20Double%20Reading%20Mammograms:%20The%20UK%20National%20Health%20Service%20Breast%20Screening%20Program&rft.jtitle=Radiology&rft.au=Chen,%20Yan&rft.date=2023-01&rft.volume=306&rft.issue=1&rft.spage=102&rft.epage=109&rft.pages=102-109&rft.issn=0033-8419&rft.eissn=1527-1315&rft_id=info:doi/10.1148/radiol.212951&rft_dat=%3Cproquest_cross%3E2714064034%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2714064034&rft_id=info:pmid/36098643&rfr_iscdi=true