Comparative evaluation of digitally fabricated complete dentures versus conventional complete dentures: A randomized, single-blinded, cross-over clinical trial

Clinical trials comparing outcomes associated with digital complete dentures (CDs) fabricated from intraoral scan data with those of CDs fabricated by using the conventional workflow are lacking. The purpose of this randomized clinical trial was to evaluate the clinical performance of and patient sa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of prosthetic dentistry 2024-08, Vol.132 (2), p.408-418
Hauptverfasser: Kang, You-Jung, Oh, Kyung Chul, Kim, Gi Youn, Moon, Hong Seok
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 418
container_issue 2
container_start_page 408
container_title The Journal of prosthetic dentistry
container_volume 132
creator Kang, You-Jung
Oh, Kyung Chul
Kim, Gi Youn
Moon, Hong Seok
description Clinical trials comparing outcomes associated with digital complete dentures (CDs) fabricated from intraoral scan data with those of CDs fabricated by using the conventional workflow are lacking. The purpose of this randomized clinical trial was to evaluate the clinical performance of and patient satisfaction associated with digitally versus conventionally fabricated CDs. Eight participants requiring CDs were enrolled in this study. Two sets of CDs were fabricated for each participant. One set was fabricated by using a digital workflow, which involved digital scanning with an intraoral scanner, whereas the other set was made by using the conventional workflow. The participants were given 1 set of CDs for 1 month and another set for the next month. The order of placing CDs was randomly selected for each participant. The internal adaptation, masticatory force, and masticatory efficiency of the CDs in each group were evaluated for objective analysis. Additionally, a questionnaire was provided to the participants, and the responses were evaluated for subjective satisfaction analysis. All parameters were analyzed by using t tests (α=.05). The internal adaptation did not statistically significantly differ between the conventional and digital CDs with regard to the maxillary arches (P=.406) and mandibular arches (P=.412). The average masticatory force (P=.051) and maximum masticatory force (P=.110) likewise did not statistically significantly differ between the 2 types of CDs. Masticatory efficiency, expressed via the mixing ability index, was statistically better for conventional CDs than the digital CDs (P=.009). No statistically significant differences were observed between the 2 types of CDs in terms of overall patient satisfaction as assessed by using the study questionnaire (P=.172 for maxillary CD and P=.161 for mandibular CD). However, the conventional CDs were statistically significantly better than the digital CDs with regard to subjective satisfaction with pronunciation ability (P=.006). The digital CDs were inferior to the conventional CDs in terms of masticatory efficiency and pronunciation. However, internal adaptation and overall patient satisfaction were comparable between conventional and digital CDs. This finding suggests that intraoral scanning and additively manufactured CDs may be suitable for edentulous patients, at least for interim use.
doi_str_mv 10.1016/j.prosdent.2022.05.013
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2714059912</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022391322003390</els_id><sourcerecordid>2714059912</sourcerecordid><originalsourceid>FETCH-LOGICAL-c298t-e948b4a87aa7ace18794ea78ed1d8c16639295b72144ca0cf2e69a57bc3fb2633</originalsourceid><addsrcrecordid>eNqFkcFu1DAQhi0EotvCK1Q-ciDBdhI75kS1AopUiQucrYk9qbxyksV2IpWX4VXxsi0XDpxsz3wzv2d-Qq45qznj8t2hPsYlOZxzLZgQNetqxptnZMeZVpXsW_6c7FjJVI3mzQW5TOnAGOs7xV-Si0YyLTUXO_Jrv0xHiJD9hhQ3CGu5LjNdRur8vc8QwgMdYYjeQkZHbcEDZqQn6TViohvGtKaSmLcSKrUQ_qXe0xsaYXbL5H-ie0uTn-8DVkPwszu9bRkmVUvpRW2JFbFAc_QQXpEXI4SErx_PK_L908dv-9vq7uvnL_ubu8oK3ecKddsPLfQKQIFF3ivdIqgeHXe95VI2WuhuUIK3rQVmR4FSQ6cG24yDkE1zRd6c-5a1_lgxZTP5ZDEEmHFZkxGKt6zTZWcFlWf0z6cjjuYY_QTxwXBmTuaYg3kyx5zMMawzxZxSeP2osQ4Tur9lT24U4MMZwDLp5jGaZD3OFp2PaLNxi_-fxm-qFakR</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2714059912</pqid></control><display><type>article</type><title>Comparative evaluation of digitally fabricated complete dentures versus conventional complete dentures: A randomized, single-blinded, cross-over clinical trial</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Kang, You-Jung ; Oh, Kyung Chul ; Kim, Gi Youn ; Moon, Hong Seok</creator><creatorcontrib>Kang, You-Jung ; Oh, Kyung Chul ; Kim, Gi Youn ; Moon, Hong Seok</creatorcontrib><description>Clinical trials comparing outcomes associated with digital complete dentures (CDs) fabricated from intraoral scan data with those of CDs fabricated by using the conventional workflow are lacking. The purpose of this randomized clinical trial was to evaluate the clinical performance of and patient satisfaction associated with digitally versus conventionally fabricated CDs. Eight participants requiring CDs were enrolled in this study. Two sets of CDs were fabricated for each participant. One set was fabricated by using a digital workflow, which involved digital scanning with an intraoral scanner, whereas the other set was made by using the conventional workflow. The participants were given 1 set of CDs for 1 month and another set for the next month. The order of placing CDs was randomly selected for each participant. The internal adaptation, masticatory force, and masticatory efficiency of the CDs in each group were evaluated for objective analysis. Additionally, a questionnaire was provided to the participants, and the responses were evaluated for subjective satisfaction analysis. All parameters were analyzed by using t tests (α=.05). The internal adaptation did not statistically significantly differ between the conventional and digital CDs with regard to the maxillary arches (P=.406) and mandibular arches (P=.412). The average masticatory force (P=.051) and maximum masticatory force (P=.110) likewise did not statistically significantly differ between the 2 types of CDs. Masticatory efficiency, expressed via the mixing ability index, was statistically better for conventional CDs than the digital CDs (P=.009). No statistically significant differences were observed between the 2 types of CDs in terms of overall patient satisfaction as assessed by using the study questionnaire (P=.172 for maxillary CD and P=.161 for mandibular CD). However, the conventional CDs were statistically significantly better than the digital CDs with regard to subjective satisfaction with pronunciation ability (P=.006). The digital CDs were inferior to the conventional CDs in terms of masticatory efficiency and pronunciation. However, internal adaptation and overall patient satisfaction were comparable between conventional and digital CDs. This finding suggests that intraoral scanning and additively manufactured CDs may be suitable for edentulous patients, at least for interim use.</description><identifier>ISSN: 0022-3913</identifier><identifier>ISSN: 1097-6841</identifier><identifier>EISSN: 1097-6841</identifier><identifier>DOI: 10.1016/j.prosdent.2022.05.013</identifier><identifier>PMID: 36096912</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Aged ; Bite Force ; Computer-Aided Design ; Cross-Over Studies ; Denture Design - methods ; Denture, Complete ; Female ; Humans ; Male ; Mastication - physiology ; Middle Aged ; Patient Satisfaction ; Single-Blind Method</subject><ispartof>The Journal of prosthetic dentistry, 2024-08, Vol.132 (2), p.408-418</ispartof><rights>2022 Editorial Council for the Journal of Prosthetic Dentistry</rights><rights>Copyright © 2022 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c298t-e948b4a87aa7ace18794ea78ed1d8c16639295b72144ca0cf2e69a57bc3fb2633</citedby><cites>FETCH-LOGICAL-c298t-e948b4a87aa7ace18794ea78ed1d8c16639295b72144ca0cf2e69a57bc3fb2633</cites><orcidid>0000-0003-4584-2597 ; 0000-0001-8118-8145 ; 0000-0002-4984-3071</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.prosdent.2022.05.013$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36096912$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kang, You-Jung</creatorcontrib><creatorcontrib>Oh, Kyung Chul</creatorcontrib><creatorcontrib>Kim, Gi Youn</creatorcontrib><creatorcontrib>Moon, Hong Seok</creatorcontrib><title>Comparative evaluation of digitally fabricated complete dentures versus conventional complete dentures: A randomized, single-blinded, cross-over clinical trial</title><title>The Journal of prosthetic dentistry</title><addtitle>J Prosthet Dent</addtitle><description>Clinical trials comparing outcomes associated with digital complete dentures (CDs) fabricated from intraoral scan data with those of CDs fabricated by using the conventional workflow are lacking. The purpose of this randomized clinical trial was to evaluate the clinical performance of and patient satisfaction associated with digitally versus conventionally fabricated CDs. Eight participants requiring CDs were enrolled in this study. Two sets of CDs were fabricated for each participant. One set was fabricated by using a digital workflow, which involved digital scanning with an intraoral scanner, whereas the other set was made by using the conventional workflow. The participants were given 1 set of CDs for 1 month and another set for the next month. The order of placing CDs was randomly selected for each participant. The internal adaptation, masticatory force, and masticatory efficiency of the CDs in each group were evaluated for objective analysis. Additionally, a questionnaire was provided to the participants, and the responses were evaluated for subjective satisfaction analysis. All parameters were analyzed by using t tests (α=.05). The internal adaptation did not statistically significantly differ between the conventional and digital CDs with regard to the maxillary arches (P=.406) and mandibular arches (P=.412). The average masticatory force (P=.051) and maximum masticatory force (P=.110) likewise did not statistically significantly differ between the 2 types of CDs. Masticatory efficiency, expressed via the mixing ability index, was statistically better for conventional CDs than the digital CDs (P=.009). No statistically significant differences were observed between the 2 types of CDs in terms of overall patient satisfaction as assessed by using the study questionnaire (P=.172 for maxillary CD and P=.161 for mandibular CD). However, the conventional CDs were statistically significantly better than the digital CDs with regard to subjective satisfaction with pronunciation ability (P=.006). The digital CDs were inferior to the conventional CDs in terms of masticatory efficiency and pronunciation. However, internal adaptation and overall patient satisfaction were comparable between conventional and digital CDs. This finding suggests that intraoral scanning and additively manufactured CDs may be suitable for edentulous patients, at least for interim use.</description><subject>Aged</subject><subject>Bite Force</subject><subject>Computer-Aided Design</subject><subject>Cross-Over Studies</subject><subject>Denture Design - methods</subject><subject>Denture, Complete</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Mastication - physiology</subject><subject>Middle Aged</subject><subject>Patient Satisfaction</subject><subject>Single-Blind Method</subject><issn>0022-3913</issn><issn>1097-6841</issn><issn>1097-6841</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkcFu1DAQhi0EotvCK1Q-ciDBdhI75kS1AopUiQucrYk9qbxyksV2IpWX4VXxsi0XDpxsz3wzv2d-Qq45qznj8t2hPsYlOZxzLZgQNetqxptnZMeZVpXsW_6c7FjJVI3mzQW5TOnAGOs7xV-Si0YyLTUXO_Jrv0xHiJD9hhQ3CGu5LjNdRur8vc8QwgMdYYjeQkZHbcEDZqQn6TViohvGtKaSmLcSKrUQ_qXe0xsaYXbL5H-ie0uTn-8DVkPwszu9bRkmVUvpRW2JFbFAc_QQXpEXI4SErx_PK_L908dv-9vq7uvnL_ubu8oK3ecKddsPLfQKQIFF3ivdIqgeHXe95VI2WuhuUIK3rQVmR4FSQ6cG24yDkE1zRd6c-5a1_lgxZTP5ZDEEmHFZkxGKt6zTZWcFlWf0z6cjjuYY_QTxwXBmTuaYg3kyx5zMMawzxZxSeP2osQ4Tur9lT24U4MMZwDLp5jGaZD3OFp2PaLNxi_-fxm-qFakR</recordid><startdate>202408</startdate><enddate>202408</enddate><creator>Kang, You-Jung</creator><creator>Oh, Kyung Chul</creator><creator>Kim, Gi Youn</creator><creator>Moon, Hong Seok</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4584-2597</orcidid><orcidid>https://orcid.org/0000-0001-8118-8145</orcidid><orcidid>https://orcid.org/0000-0002-4984-3071</orcidid></search><sort><creationdate>202408</creationdate><title>Comparative evaluation of digitally fabricated complete dentures versus conventional complete dentures: A randomized, single-blinded, cross-over clinical trial</title><author>Kang, You-Jung ; Oh, Kyung Chul ; Kim, Gi Youn ; Moon, Hong Seok</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c298t-e948b4a87aa7ace18794ea78ed1d8c16639295b72144ca0cf2e69a57bc3fb2633</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Aged</topic><topic>Bite Force</topic><topic>Computer-Aided Design</topic><topic>Cross-Over Studies</topic><topic>Denture Design - methods</topic><topic>Denture, Complete</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Mastication - physiology</topic><topic>Middle Aged</topic><topic>Patient Satisfaction</topic><topic>Single-Blind Method</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kang, You-Jung</creatorcontrib><creatorcontrib>Oh, Kyung Chul</creatorcontrib><creatorcontrib>Kim, Gi Youn</creatorcontrib><creatorcontrib>Moon, Hong Seok</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of prosthetic dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kang, You-Jung</au><au>Oh, Kyung Chul</au><au>Kim, Gi Youn</au><au>Moon, Hong Seok</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative evaluation of digitally fabricated complete dentures versus conventional complete dentures: A randomized, single-blinded, cross-over clinical trial</atitle><jtitle>The Journal of prosthetic dentistry</jtitle><addtitle>J Prosthet Dent</addtitle><date>2024-08</date><risdate>2024</risdate><volume>132</volume><issue>2</issue><spage>408</spage><epage>418</epage><pages>408-418</pages><issn>0022-3913</issn><issn>1097-6841</issn><eissn>1097-6841</eissn><abstract>Clinical trials comparing outcomes associated with digital complete dentures (CDs) fabricated from intraoral scan data with those of CDs fabricated by using the conventional workflow are lacking. The purpose of this randomized clinical trial was to evaluate the clinical performance of and patient satisfaction associated with digitally versus conventionally fabricated CDs. Eight participants requiring CDs were enrolled in this study. Two sets of CDs were fabricated for each participant. One set was fabricated by using a digital workflow, which involved digital scanning with an intraoral scanner, whereas the other set was made by using the conventional workflow. The participants were given 1 set of CDs for 1 month and another set for the next month. The order of placing CDs was randomly selected for each participant. The internal adaptation, masticatory force, and masticatory efficiency of the CDs in each group were evaluated for objective analysis. Additionally, a questionnaire was provided to the participants, and the responses were evaluated for subjective satisfaction analysis. All parameters were analyzed by using t tests (α=.05). The internal adaptation did not statistically significantly differ between the conventional and digital CDs with regard to the maxillary arches (P=.406) and mandibular arches (P=.412). The average masticatory force (P=.051) and maximum masticatory force (P=.110) likewise did not statistically significantly differ between the 2 types of CDs. Masticatory efficiency, expressed via the mixing ability index, was statistically better for conventional CDs than the digital CDs (P=.009). No statistically significant differences were observed between the 2 types of CDs in terms of overall patient satisfaction as assessed by using the study questionnaire (P=.172 for maxillary CD and P=.161 for mandibular CD). However, the conventional CDs were statistically significantly better than the digital CDs with regard to subjective satisfaction with pronunciation ability (P=.006). The digital CDs were inferior to the conventional CDs in terms of masticatory efficiency and pronunciation. However, internal adaptation and overall patient satisfaction were comparable between conventional and digital CDs. This finding suggests that intraoral scanning and additively manufactured CDs may be suitable for edentulous patients, at least for interim use.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>36096912</pmid><doi>10.1016/j.prosdent.2022.05.013</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0003-4584-2597</orcidid><orcidid>https://orcid.org/0000-0001-8118-8145</orcidid><orcidid>https://orcid.org/0000-0002-4984-3071</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0022-3913
ispartof The Journal of prosthetic dentistry, 2024-08, Vol.132 (2), p.408-418
issn 0022-3913
1097-6841
1097-6841
language eng
recordid cdi_proquest_miscellaneous_2714059912
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Aged
Bite Force
Computer-Aided Design
Cross-Over Studies
Denture Design - methods
Denture, Complete
Female
Humans
Male
Mastication - physiology
Middle Aged
Patient Satisfaction
Single-Blind Method
title Comparative evaluation of digitally fabricated complete dentures versus conventional complete dentures: A randomized, single-blinded, cross-over clinical trial
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T23%3A07%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20evaluation%20of%20digitally%20fabricated%20complete%20dentures%20versus%20conventional%20complete%20dentures:%20A%20randomized,%20single-blinded,%20cross-over%20clinical%20trial&rft.jtitle=The%20Journal%20of%20prosthetic%20dentistry&rft.au=Kang,%20You-Jung&rft.date=2024-08&rft.volume=132&rft.issue=2&rft.spage=408&rft.epage=418&rft.pages=408-418&rft.issn=0022-3913&rft.eissn=1097-6841&rft_id=info:doi/10.1016/j.prosdent.2022.05.013&rft_dat=%3Cproquest_cross%3E2714059912%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2714059912&rft_id=info:pmid/36096912&rft_els_id=S0022391322003390&rfr_iscdi=true