Developing high intensity ultrasonic cleaning (HIUC) for post-processing additively manufactured metal components

•We designed and developed a high-intensity ultrasonic cleaning (HIUC) process for post-processing of additively manufactured metal components.•Cavitation intensity was characterised and mapped through acoustic signal emission analysis via hydrophone.•Strong subharmonic (f0/2) signal intensity at th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ultrasonics 2022-12, Vol.126, p.106829-106829, Article 106829
Hauptverfasser: Tan, W.X., Tan, K.W., Tan, K.L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 106829
container_issue
container_start_page 106829
container_title Ultrasonics
container_volume 126
creator Tan, W.X.
Tan, K.W.
Tan, K.L.
description •We designed and developed a high-intensity ultrasonic cleaning (HIUC) process for post-processing of additively manufactured metal components.•Cavitation intensity was characterised and mapped through acoustic signal emission analysis via hydrophone.•Strong subharmonic (f0/2) signal intensity at the central zone indicated that inertial cavitation had been achieved.•Cavitation intensity distribution is dependent on the transducer placement location, temperature, and ultrasonic power.•HIUC induced >200% more material removal on as-built AM lattice component than a conventional ultrasonic cleaner. The high energy phenomenon of cavitation bubble collapses has enabled numerous applications, including cleaning. In ultrasonic cleaning, cavitation intensity is typically lower than in other applications, such as sonochemistry and material processing. However, there has been an emerging application in intense cleaning of metal additively manufactured (AM) components. The presence of partially melted powders on AM surfaces is undesirable, contributing to high surface roughness and posing contamination risks during usage. We designed a high-intensity cavitation cleaning process that has significantly higher inertial cavitation intensity – i.e., erosion potential – than a conventional ultrasonic cleaning tank. Through acoustic signal characterisation, we showed that placing transducer sets on four sides of the tank could effectively focus and generate high-amplitude pressure waves directed towards the central region. Strong subharmonic signals indicate intensely inertial cavitation throughout the tank. Cavitation intensities were measured at various locations to understand the wave transmission characteristics and distribution patterns. Our results show that the cavitation intensity distribution is highly dependent on the height position. Finally, we demonstrated that the high intensity ultrasonic cleaning (HIUC) process could remove partially melted powders from an AM surface – which was not possible through conventional ultrasonic cleaning. HIUC could lead to higher cleaning efficiency and enhanced AM specimen cleanliness.
doi_str_mv 10.1016/j.ultras.2022.106829
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2706182387</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0041624X22001354</els_id><sourcerecordid>2706182387</sourcerecordid><originalsourceid>FETCH-LOGICAL-c339t-e7c7aaec5068a5778d1889891b01129b3070d4374bf2f7bcb8ec47d4b33e3d03</originalsourceid><addsrcrecordid>eNp9kE9rGzEQxUVoIW7ab5CDjs5hXf3zSnsJBKetA4FeXOhNaKXZRGZXWktag79912zOPQ3MvPeY90PonpINJbT-ftxMfUkmbxhhbF7VijU3aEWVFFXT1OoTWhEiaFUz8fcWfcn5SAgVivIVOj3DGfo4-vCG3_3bO_ahQMi-XPCSGYO32PZgwlWy3r_82T3gLiY8xlyqMUULOV9Pxjlf_Bx2wYMJU2dsmRI4PEAxPbZxGGOAUPJX9LkzfYZvH_MOHX7-OOz21evvXy-7p9fKct6UCqSVxoDdzm3MVkrlqFKNamhLKGVNy4kkTnAp2o51srWtAiukEy3nwB3hd2i9xM4vnibIRQ8-W-h7EyBOWTNJaqoYV3KWikVqU8w5QafH5AeTLpoSfQWsj3qBoa-A9QJ4tj0uNphbnD0kna2HYMH5BLZoF_3_A_4B7riIsw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2706182387</pqid></control><display><type>article</type><title>Developing high intensity ultrasonic cleaning (HIUC) for post-processing additively manufactured metal components</title><source>Elsevier ScienceDirect Journals</source><creator>Tan, W.X. ; Tan, K.W. ; Tan, K.L.</creator><creatorcontrib>Tan, W.X. ; Tan, K.W. ; Tan, K.L.</creatorcontrib><description>•We designed and developed a high-intensity ultrasonic cleaning (HIUC) process for post-processing of additively manufactured metal components.•Cavitation intensity was characterised and mapped through acoustic signal emission analysis via hydrophone.•Strong subharmonic (f0/2) signal intensity at the central zone indicated that inertial cavitation had been achieved.•Cavitation intensity distribution is dependent on the transducer placement location, temperature, and ultrasonic power.•HIUC induced &gt;200% more material removal on as-built AM lattice component than a conventional ultrasonic cleaner. The high energy phenomenon of cavitation bubble collapses has enabled numerous applications, including cleaning. In ultrasonic cleaning, cavitation intensity is typically lower than in other applications, such as sonochemistry and material processing. However, there has been an emerging application in intense cleaning of metal additively manufactured (AM) components. The presence of partially melted powders on AM surfaces is undesirable, contributing to high surface roughness and posing contamination risks during usage. We designed a high-intensity cavitation cleaning process that has significantly higher inertial cavitation intensity – i.e., erosion potential – than a conventional ultrasonic cleaning tank. Through acoustic signal characterisation, we showed that placing transducer sets on four sides of the tank could effectively focus and generate high-amplitude pressure waves directed towards the central region. Strong subharmonic signals indicate intensely inertial cavitation throughout the tank. Cavitation intensities were measured at various locations to understand the wave transmission characteristics and distribution patterns. Our results show that the cavitation intensity distribution is highly dependent on the height position. Finally, we demonstrated that the high intensity ultrasonic cleaning (HIUC) process could remove partially melted powders from an AM surface – which was not possible through conventional ultrasonic cleaning. HIUC could lead to higher cleaning efficiency and enhanced AM specimen cleanliness.</description><identifier>ISSN: 0041-624X</identifier><identifier>EISSN: 1874-9968</identifier><identifier>DOI: 10.1016/j.ultras.2022.106829</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Acoustic signal analysis ; Cavitation characterisation ; Focused ultrasonic wave ; Ultrasonic cavitation ; Ultrasonic cleaning</subject><ispartof>Ultrasonics, 2022-12, Vol.126, p.106829-106829, Article 106829</ispartof><rights>2022 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c339t-e7c7aaec5068a5778d1889891b01129b3070d4374bf2f7bcb8ec47d4b33e3d03</citedby><cites>FETCH-LOGICAL-c339t-e7c7aaec5068a5778d1889891b01129b3070d4374bf2f7bcb8ec47d4b33e3d03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0041624X22001354$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Tan, W.X.</creatorcontrib><creatorcontrib>Tan, K.W.</creatorcontrib><creatorcontrib>Tan, K.L.</creatorcontrib><title>Developing high intensity ultrasonic cleaning (HIUC) for post-processing additively manufactured metal components</title><title>Ultrasonics</title><description>•We designed and developed a high-intensity ultrasonic cleaning (HIUC) process for post-processing of additively manufactured metal components.•Cavitation intensity was characterised and mapped through acoustic signal emission analysis via hydrophone.•Strong subharmonic (f0/2) signal intensity at the central zone indicated that inertial cavitation had been achieved.•Cavitation intensity distribution is dependent on the transducer placement location, temperature, and ultrasonic power.•HIUC induced &gt;200% more material removal on as-built AM lattice component than a conventional ultrasonic cleaner. The high energy phenomenon of cavitation bubble collapses has enabled numerous applications, including cleaning. In ultrasonic cleaning, cavitation intensity is typically lower than in other applications, such as sonochemistry and material processing. However, there has been an emerging application in intense cleaning of metal additively manufactured (AM) components. The presence of partially melted powders on AM surfaces is undesirable, contributing to high surface roughness and posing contamination risks during usage. We designed a high-intensity cavitation cleaning process that has significantly higher inertial cavitation intensity – i.e., erosion potential – than a conventional ultrasonic cleaning tank. Through acoustic signal characterisation, we showed that placing transducer sets on four sides of the tank could effectively focus and generate high-amplitude pressure waves directed towards the central region. Strong subharmonic signals indicate intensely inertial cavitation throughout the tank. Cavitation intensities were measured at various locations to understand the wave transmission characteristics and distribution patterns. Our results show that the cavitation intensity distribution is highly dependent on the height position. Finally, we demonstrated that the high intensity ultrasonic cleaning (HIUC) process could remove partially melted powders from an AM surface – which was not possible through conventional ultrasonic cleaning. HIUC could lead to higher cleaning efficiency and enhanced AM specimen cleanliness.</description><subject>Acoustic signal analysis</subject><subject>Cavitation characterisation</subject><subject>Focused ultrasonic wave</subject><subject>Ultrasonic cavitation</subject><subject>Ultrasonic cleaning</subject><issn>0041-624X</issn><issn>1874-9968</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kE9rGzEQxUVoIW7ab5CDjs5hXf3zSnsJBKetA4FeXOhNaKXZRGZXWktag79912zOPQ3MvPeY90PonpINJbT-ftxMfUkmbxhhbF7VijU3aEWVFFXT1OoTWhEiaFUz8fcWfcn5SAgVivIVOj3DGfo4-vCG3_3bO_ahQMi-XPCSGYO32PZgwlWy3r_82T3gLiY8xlyqMUULOV9Pxjlf_Bx2wYMJU2dsmRI4PEAxPbZxGGOAUPJX9LkzfYZvH_MOHX7-OOz21evvXy-7p9fKct6UCqSVxoDdzm3MVkrlqFKNamhLKGVNy4kkTnAp2o51srWtAiukEy3nwB3hd2i9xM4vnibIRQ8-W-h7EyBOWTNJaqoYV3KWikVqU8w5QafH5AeTLpoSfQWsj3qBoa-A9QJ4tj0uNphbnD0kna2HYMH5BLZoF_3_A_4B7riIsw</recordid><startdate>202212</startdate><enddate>202212</enddate><creator>Tan, W.X.</creator><creator>Tan, K.W.</creator><creator>Tan, K.L.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202212</creationdate><title>Developing high intensity ultrasonic cleaning (HIUC) for post-processing additively manufactured metal components</title><author>Tan, W.X. ; Tan, K.W. ; Tan, K.L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c339t-e7c7aaec5068a5778d1889891b01129b3070d4374bf2f7bcb8ec47d4b33e3d03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Acoustic signal analysis</topic><topic>Cavitation characterisation</topic><topic>Focused ultrasonic wave</topic><topic>Ultrasonic cavitation</topic><topic>Ultrasonic cleaning</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tan, W.X.</creatorcontrib><creatorcontrib>Tan, K.W.</creatorcontrib><creatorcontrib>Tan, K.L.</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Ultrasonics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tan, W.X.</au><au>Tan, K.W.</au><au>Tan, K.L.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Developing high intensity ultrasonic cleaning (HIUC) for post-processing additively manufactured metal components</atitle><jtitle>Ultrasonics</jtitle><date>2022-12</date><risdate>2022</risdate><volume>126</volume><spage>106829</spage><epage>106829</epage><pages>106829-106829</pages><artnum>106829</artnum><issn>0041-624X</issn><eissn>1874-9968</eissn><abstract>•We designed and developed a high-intensity ultrasonic cleaning (HIUC) process for post-processing of additively manufactured metal components.•Cavitation intensity was characterised and mapped through acoustic signal emission analysis via hydrophone.•Strong subharmonic (f0/2) signal intensity at the central zone indicated that inertial cavitation had been achieved.•Cavitation intensity distribution is dependent on the transducer placement location, temperature, and ultrasonic power.•HIUC induced &gt;200% more material removal on as-built AM lattice component than a conventional ultrasonic cleaner. The high energy phenomenon of cavitation bubble collapses has enabled numerous applications, including cleaning. In ultrasonic cleaning, cavitation intensity is typically lower than in other applications, such as sonochemistry and material processing. However, there has been an emerging application in intense cleaning of metal additively manufactured (AM) components. The presence of partially melted powders on AM surfaces is undesirable, contributing to high surface roughness and posing contamination risks during usage. We designed a high-intensity cavitation cleaning process that has significantly higher inertial cavitation intensity – i.e., erosion potential – than a conventional ultrasonic cleaning tank. Through acoustic signal characterisation, we showed that placing transducer sets on four sides of the tank could effectively focus and generate high-amplitude pressure waves directed towards the central region. Strong subharmonic signals indicate intensely inertial cavitation throughout the tank. Cavitation intensities were measured at various locations to understand the wave transmission characteristics and distribution patterns. Our results show that the cavitation intensity distribution is highly dependent on the height position. Finally, we demonstrated that the high intensity ultrasonic cleaning (HIUC) process could remove partially melted powders from an AM surface – which was not possible through conventional ultrasonic cleaning. HIUC could lead to higher cleaning efficiency and enhanced AM specimen cleanliness.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.ultras.2022.106829</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0041-624X
ispartof Ultrasonics, 2022-12, Vol.126, p.106829-106829, Article 106829
issn 0041-624X
1874-9968
language eng
recordid cdi_proquest_miscellaneous_2706182387
source Elsevier ScienceDirect Journals
subjects Acoustic signal analysis
Cavitation characterisation
Focused ultrasonic wave
Ultrasonic cavitation
Ultrasonic cleaning
title Developing high intensity ultrasonic cleaning (HIUC) for post-processing additively manufactured metal components
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T19%3A44%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Developing%20high%20intensity%20ultrasonic%20cleaning%20(HIUC)%20for%20post-processing%20additively%20manufactured%20metal%20components&rft.jtitle=Ultrasonics&rft.au=Tan,%20W.X.&rft.date=2022-12&rft.volume=126&rft.spage=106829&rft.epage=106829&rft.pages=106829-106829&rft.artnum=106829&rft.issn=0041-624X&rft.eissn=1874-9968&rft_id=info:doi/10.1016/j.ultras.2022.106829&rft_dat=%3Cproquest_cross%3E2706182387%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2706182387&rft_id=info:pmid/&rft_els_id=S0041624X22001354&rfr_iscdi=true