Validation of finite element models for orthodontic aligners

Clear thermoplastic aligners have become popular in orthodontics, but the biomechanics of these devices is not well understood. Neither is the tooth movement induced by such devices. The aim of this study was to develop and validate finite element (FE) models for clear thermoplastic teeth aligners f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the mechanical behavior of biomedical materials 2022-10, Vol.134, p.105404-105404, Article 105404
Hauptverfasser: Ye, N., Brown, B.E., Mantell, S.C., Heo, Y.C., Larson, B.E., Fok, A.S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 105404
container_issue
container_start_page 105404
container_title Journal of the mechanical behavior of biomedical materials
container_volume 134
creator Ye, N.
Brown, B.E.
Mantell, S.C.
Heo, Y.C.
Larson, B.E.
Fok, A.S.
description Clear thermoplastic aligners have become popular in orthodontics, but the biomechanics of these devices is not well understood. Neither is the tooth movement induced by such devices. The aim of this study was to develop and validate finite element (FE) models for clear thermoplastic teeth aligners for orthodontic force prediction. FE models were created from Micro-CT scans of an aligner and a model arch of teeth with one of the incisors tipped buccal-lingually by 2.4°. The models were uniformly meshed with 0.3-mm long elements. Linear-elastic mechanical properties provided by the material manufacturers were used. Fitting of the two components was simulated using Abaqus's interference fit, followed by frictional surface-to-surface interaction. The assembled FE model was validated by comparing its prediction for the teeth-aligner gaps and aligner surface strains with experimental data. The experimental teeth-aligner gaps were obtained from the Micro-CT scans whereas the aligner surface strains were measured using a 2-camera digital image correlation (DIC) system. Good agreement between prediction and measurement was obtained for both the teeth-aligner gaps and aligner surface strains. The linear regression between prediction and measurement for teeth-aligner gaps sampled at different positions had a R2 value of 0.99. The mean difference between prediction and measurement for the aligner surface strains (von Mises) over 1544 nodes on the labial side and 1929 nodes on the lingual side was 0.07% and 0.01%, respectively, both being lower than the mean background noise. A FE model for clear thermoplastic teeth aligners has been successfully developed and validated. The model can therefore be used with confidence to predict the forces and moments applied to teeth by the aligners, thus improving our understanding of the biomechanics of such devices and the tooth movement they induce. [Display omitted] •A finite element model has been developed to simulate the interaction between orthodontic aligners and the underlying teeth.•The model has been validated using data provided by micro-CT and digital image correlation.•The model can be used with confidence to predict the tooth forces and moments generated by aligners.
doi_str_mv 10.1016/j.jmbbm.2022.105404
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2699956784</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1751616122003101</els_id><sourcerecordid>2699956784</sourcerecordid><originalsourceid>FETCH-LOGICAL-c336t-bd197e1ee910679fffc4cac63444c158b19fcea63e61f051c3b0100de1e18723</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhoMouK7-Ai89euk604-0BT3I4qqw4GXxGtpkoiltsyZZwX9v1nr2NMPwPgPvw9g1wgoB-W2_6seuG1cZZFm8lAUUJ2yBdVWngDWcxr0qMeXI8ZxdeN8DcIC6XrC7t3Ywqg3GTonViTaTCZTQQCNNIRmtosEn2rrEuvBhlZ2CkUlE3idy_pKd6XbwdPU3l2y3edytn9Pt69PL-mGbyjznIe0UNhUhUYPAq0ZrLQvZSp4XRSGxrDtstKSW58RRQ4ky7wABVERihSxfspv57d7ZzwP5IEbjJQ1DO5E9eJHxpmlKXtVFjOZzVDrrvSMt9s6MrfsWCOKoSvTiV5U4qhKzqkjdz1QsS1-GnPDS0CRJGUcyCGXNv_wPT5ty2A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2699956784</pqid></control><display><type>article</type><title>Validation of finite element models for orthodontic aligners</title><source>Elsevier ScienceDirect Journals</source><creator>Ye, N. ; Brown, B.E. ; Mantell, S.C. ; Heo, Y.C. ; Larson, B.E. ; Fok, A.S.</creator><creatorcontrib>Ye, N. ; Brown, B.E. ; Mantell, S.C. ; Heo, Y.C. ; Larson, B.E. ; Fok, A.S.</creatorcontrib><description>Clear thermoplastic aligners have become popular in orthodontics, but the biomechanics of these devices is not well understood. Neither is the tooth movement induced by such devices. The aim of this study was to develop and validate finite element (FE) models for clear thermoplastic teeth aligners for orthodontic force prediction. FE models were created from Micro-CT scans of an aligner and a model arch of teeth with one of the incisors tipped buccal-lingually by 2.4°. The models were uniformly meshed with 0.3-mm long elements. Linear-elastic mechanical properties provided by the material manufacturers were used. Fitting of the two components was simulated using Abaqus's interference fit, followed by frictional surface-to-surface interaction. The assembled FE model was validated by comparing its prediction for the teeth-aligner gaps and aligner surface strains with experimental data. The experimental teeth-aligner gaps were obtained from the Micro-CT scans whereas the aligner surface strains were measured using a 2-camera digital image correlation (DIC) system. Good agreement between prediction and measurement was obtained for both the teeth-aligner gaps and aligner surface strains. The linear regression between prediction and measurement for teeth-aligner gaps sampled at different positions had a R2 value of 0.99. The mean difference between prediction and measurement for the aligner surface strains (von Mises) over 1544 nodes on the labial side and 1929 nodes on the lingual side was 0.07% and 0.01%, respectively, both being lower than the mean background noise. A FE model for clear thermoplastic teeth aligners has been successfully developed and validated. The model can therefore be used with confidence to predict the forces and moments applied to teeth by the aligners, thus improving our understanding of the biomechanics of such devices and the tooth movement they induce. [Display omitted] •A finite element model has been developed to simulate the interaction between orthodontic aligners and the underlying teeth.•The model has been validated using data provided by micro-CT and digital image correlation.•The model can be used with confidence to predict the tooth forces and moments generated by aligners.</description><identifier>ISSN: 1751-6161</identifier><identifier>EISSN: 1878-0180</identifier><identifier>DOI: 10.1016/j.jmbbm.2022.105404</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Digital image correlation (DIC) ; Finite element models ; Micro-CT ; Orthodontic aligners ; Validation</subject><ispartof>Journal of the mechanical behavior of biomedical materials, 2022-10, Vol.134, p.105404-105404, Article 105404</ispartof><rights>2022 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c336t-bd197e1ee910679fffc4cac63444c158b19fcea63e61f051c3b0100de1e18723</citedby><cites>FETCH-LOGICAL-c336t-bd197e1ee910679fffc4cac63444c158b19fcea63e61f051c3b0100de1e18723</cites><orcidid>0000-0002-4271-0153 ; 0000-0002-2179-2743 ; 0000-0003-2797-1467</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jmbbm.2022.105404$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids></links><search><creatorcontrib>Ye, N.</creatorcontrib><creatorcontrib>Brown, B.E.</creatorcontrib><creatorcontrib>Mantell, S.C.</creatorcontrib><creatorcontrib>Heo, Y.C.</creatorcontrib><creatorcontrib>Larson, B.E.</creatorcontrib><creatorcontrib>Fok, A.S.</creatorcontrib><title>Validation of finite element models for orthodontic aligners</title><title>Journal of the mechanical behavior of biomedical materials</title><description>Clear thermoplastic aligners have become popular in orthodontics, but the biomechanics of these devices is not well understood. Neither is the tooth movement induced by such devices. The aim of this study was to develop and validate finite element (FE) models for clear thermoplastic teeth aligners for orthodontic force prediction. FE models were created from Micro-CT scans of an aligner and a model arch of teeth with one of the incisors tipped buccal-lingually by 2.4°. The models were uniformly meshed with 0.3-mm long elements. Linear-elastic mechanical properties provided by the material manufacturers were used. Fitting of the two components was simulated using Abaqus's interference fit, followed by frictional surface-to-surface interaction. The assembled FE model was validated by comparing its prediction for the teeth-aligner gaps and aligner surface strains with experimental data. The experimental teeth-aligner gaps were obtained from the Micro-CT scans whereas the aligner surface strains were measured using a 2-camera digital image correlation (DIC) system. Good agreement between prediction and measurement was obtained for both the teeth-aligner gaps and aligner surface strains. The linear regression between prediction and measurement for teeth-aligner gaps sampled at different positions had a R2 value of 0.99. The mean difference between prediction and measurement for the aligner surface strains (von Mises) over 1544 nodes on the labial side and 1929 nodes on the lingual side was 0.07% and 0.01%, respectively, both being lower than the mean background noise. A FE model for clear thermoplastic teeth aligners has been successfully developed and validated. The model can therefore be used with confidence to predict the forces and moments applied to teeth by the aligners, thus improving our understanding of the biomechanics of such devices and the tooth movement they induce. [Display omitted] •A finite element model has been developed to simulate the interaction between orthodontic aligners and the underlying teeth.•The model has been validated using data provided by micro-CT and digital image correlation.•The model can be used with confidence to predict the tooth forces and moments generated by aligners.</description><subject>Digital image correlation (DIC)</subject><subject>Finite element models</subject><subject>Micro-CT</subject><subject>Orthodontic aligners</subject><subject>Validation</subject><issn>1751-6161</issn><issn>1878-0180</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LxDAQhoMouK7-Ai89euk604-0BT3I4qqw4GXxGtpkoiltsyZZwX9v1nr2NMPwPgPvw9g1wgoB-W2_6seuG1cZZFm8lAUUJ2yBdVWngDWcxr0qMeXI8ZxdeN8DcIC6XrC7t3Ywqg3GTonViTaTCZTQQCNNIRmtosEn2rrEuvBhlZ2CkUlE3idy_pKd6XbwdPU3l2y3edytn9Pt69PL-mGbyjznIe0UNhUhUYPAq0ZrLQvZSp4XRSGxrDtstKSW58RRQ4ky7wABVERihSxfspv57d7ZzwP5IEbjJQ1DO5E9eJHxpmlKXtVFjOZzVDrrvSMt9s6MrfsWCOKoSvTiV5U4qhKzqkjdz1QsS1-GnPDS0CRJGUcyCGXNv_wPT5ty2A</recordid><startdate>202210</startdate><enddate>202210</enddate><creator>Ye, N.</creator><creator>Brown, B.E.</creator><creator>Mantell, S.C.</creator><creator>Heo, Y.C.</creator><creator>Larson, B.E.</creator><creator>Fok, A.S.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-4271-0153</orcidid><orcidid>https://orcid.org/0000-0002-2179-2743</orcidid><orcidid>https://orcid.org/0000-0003-2797-1467</orcidid></search><sort><creationdate>202210</creationdate><title>Validation of finite element models for orthodontic aligners</title><author>Ye, N. ; Brown, B.E. ; Mantell, S.C. ; Heo, Y.C. ; Larson, B.E. ; Fok, A.S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c336t-bd197e1ee910679fffc4cac63444c158b19fcea63e61f051c3b0100de1e18723</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Digital image correlation (DIC)</topic><topic>Finite element models</topic><topic>Micro-CT</topic><topic>Orthodontic aligners</topic><topic>Validation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ye, N.</creatorcontrib><creatorcontrib>Brown, B.E.</creatorcontrib><creatorcontrib>Mantell, S.C.</creatorcontrib><creatorcontrib>Heo, Y.C.</creatorcontrib><creatorcontrib>Larson, B.E.</creatorcontrib><creatorcontrib>Fok, A.S.</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the mechanical behavior of biomedical materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ye, N.</au><au>Brown, B.E.</au><au>Mantell, S.C.</au><au>Heo, Y.C.</au><au>Larson, B.E.</au><au>Fok, A.S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Validation of finite element models for orthodontic aligners</atitle><jtitle>Journal of the mechanical behavior of biomedical materials</jtitle><date>2022-10</date><risdate>2022</risdate><volume>134</volume><spage>105404</spage><epage>105404</epage><pages>105404-105404</pages><artnum>105404</artnum><issn>1751-6161</issn><eissn>1878-0180</eissn><abstract>Clear thermoplastic aligners have become popular in orthodontics, but the biomechanics of these devices is not well understood. Neither is the tooth movement induced by such devices. The aim of this study was to develop and validate finite element (FE) models for clear thermoplastic teeth aligners for orthodontic force prediction. FE models were created from Micro-CT scans of an aligner and a model arch of teeth with one of the incisors tipped buccal-lingually by 2.4°. The models were uniformly meshed with 0.3-mm long elements. Linear-elastic mechanical properties provided by the material manufacturers were used. Fitting of the two components was simulated using Abaqus's interference fit, followed by frictional surface-to-surface interaction. The assembled FE model was validated by comparing its prediction for the teeth-aligner gaps and aligner surface strains with experimental data. The experimental teeth-aligner gaps were obtained from the Micro-CT scans whereas the aligner surface strains were measured using a 2-camera digital image correlation (DIC) system. Good agreement between prediction and measurement was obtained for both the teeth-aligner gaps and aligner surface strains. The linear regression between prediction and measurement for teeth-aligner gaps sampled at different positions had a R2 value of 0.99. The mean difference between prediction and measurement for the aligner surface strains (von Mises) over 1544 nodes on the labial side and 1929 nodes on the lingual side was 0.07% and 0.01%, respectively, both being lower than the mean background noise. A FE model for clear thermoplastic teeth aligners has been successfully developed and validated. The model can therefore be used with confidence to predict the forces and moments applied to teeth by the aligners, thus improving our understanding of the biomechanics of such devices and the tooth movement they induce. [Display omitted] •A finite element model has been developed to simulate the interaction between orthodontic aligners and the underlying teeth.•The model has been validated using data provided by micro-CT and digital image correlation.•The model can be used with confidence to predict the tooth forces and moments generated by aligners.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.jmbbm.2022.105404</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0002-4271-0153</orcidid><orcidid>https://orcid.org/0000-0002-2179-2743</orcidid><orcidid>https://orcid.org/0000-0003-2797-1467</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1751-6161
ispartof Journal of the mechanical behavior of biomedical materials, 2022-10, Vol.134, p.105404-105404, Article 105404
issn 1751-6161
1878-0180
language eng
recordid cdi_proquest_miscellaneous_2699956784
source Elsevier ScienceDirect Journals
subjects Digital image correlation (DIC)
Finite element models
Micro-CT
Orthodontic aligners
Validation
title Validation of finite element models for orthodontic aligners
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T22%3A24%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Validation%20of%20finite%20element%20models%20for%20orthodontic%20aligners&rft.jtitle=Journal%20of%20the%20mechanical%20behavior%20of%20biomedical%20materials&rft.au=Ye,%20N.&rft.date=2022-10&rft.volume=134&rft.spage=105404&rft.epage=105404&rft.pages=105404-105404&rft.artnum=105404&rft.issn=1751-6161&rft.eissn=1878-0180&rft_id=info:doi/10.1016/j.jmbbm.2022.105404&rft_dat=%3Cproquest_cross%3E2699956784%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2699956784&rft_id=info:pmid/&rft_els_id=S1751616122003101&rfr_iscdi=true