Electrochemical sensing of copper (II) ion in water using bi-metal oxide framework modified glassy carbon electrode

In this research, an electrochemical sensor was fabricated employing the metal-organic framework (MOF) deposited glassy carbon electrode (GCE) for the sensing copper ions in water with high sensitivity. The porous nanostructured MOF was characterized through Transmission electron microscope, scannin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Food and chemical toxicology 2022-09, Vol.167, p.113313-113313, Article 113313
Hauptverfasser: Theerthagiri, Senthil, Rajkannu, Parkavi, Senthil Kumar, P., Peethambaram, Prabukanthan, Ayyavu, Chandramohan, Rasu, Ramachandran, Kannaiyan, Dinakaran
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 113313
container_issue
container_start_page 113313
container_title Food and chemical toxicology
container_volume 167
creator Theerthagiri, Senthil
Rajkannu, Parkavi
Senthil Kumar, P.
Peethambaram, Prabukanthan
Ayyavu, Chandramohan
Rasu, Ramachandran
Kannaiyan, Dinakaran
description In this research, an electrochemical sensor was fabricated employing the metal-organic framework (MOF) deposited glassy carbon electrode (GCE) for the sensing copper ions in water with high sensitivity. The porous nanostructured MOF was characterized through Transmission electron microscope, scanning electron microscope and X-ray diffraction analysis. The Bi-MOF nanostructure deposited GCE (Bi-MOF/GCE) was fabricated by drop-casting a suspension of Bi-MOF in water on GCE surface. The performance of modified electrode in the presence and absence of heavy metal ions such as Cd2+, Hg2+ As3+, Pb2+ and Cu2+ was determined by the cyclic voltammetry in deionised water within the scan rate range of 25 and 300 mVs−1. The Bi-MOF/GCE displayed highest anodic and cathodic peak current for Cu2+ ions than other metal ions, which was enhanced linearly within the scan rate range of 10–100 mV s−1. Under the employed experimental conditions, the fabricated Bi-MOF/GCE based electrochemical sensor showed an outstanding routine in the determination of copper with a lowest sensing limit of 1 × 10−5 M, wide linear range variation, strong interaction between metal ions and Bi-MOF. It has long-term stability and good reproducibility. The Bi-MOF/GCE electrode was successfully tested to detect Cu2+ in tap water with acceptable results.
doi_str_mv 10.1016/j.fct.2022.113313
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2694415138</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0278691522005117</els_id><sourcerecordid>2694415138</sourcerecordid><originalsourceid>FETCH-LOGICAL-c260t-7473960185b93958c432fe0bcf46276eb6b9c6eb18c63d231512e8593d4842253</originalsourceid><addsrcrecordid>eNp9kD1PwzAQhi0EEqXwA9g8liHBH4mTiAlVBSpVYoHZcuxLcUniYKeU_nsMYWZ6pdP73OkehK4pSSmh4naXNnpMGWEspZRzyk_QjJYFTwTP6SmaEVaUiahofo4uQtgRQgpaiBkKqxb06J1-g85q1eIAfbD9FrsGazcM4PFivb7B1vXY9vigxjjZ_zZqm3QwRsR9WQO48aqDg_PvuHPGNhYM3rYqhCPWytcRh-mSgUt01qg2wNVfztHrw-pl-ZRsnh_Xy_tNopkgY1JkBa8EoWVeV7zKS51x1gCpdZMJVgioRV3pGLTUghvGaU4ZlHnFTVZmjOV8jhbT3sG7jz2EUXY2aGhb1YPbB8lElWWR4mWs0qmqvQvBQyMHbzvlj5IS-SNY7mQULH8Ey0lwZO4mBuIPnxa8DNpCr8FYHz-Vxtl_6G88L4Lp</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2694415138</pqid></control><display><type>article</type><title>Electrochemical sensing of copper (II) ion in water using bi-metal oxide framework modified glassy carbon electrode</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Theerthagiri, Senthil ; Rajkannu, Parkavi ; Senthil Kumar, P. ; Peethambaram, Prabukanthan ; Ayyavu, Chandramohan ; Rasu, Ramachandran ; Kannaiyan, Dinakaran</creator><creatorcontrib>Theerthagiri, Senthil ; Rajkannu, Parkavi ; Senthil Kumar, P. ; Peethambaram, Prabukanthan ; Ayyavu, Chandramohan ; Rasu, Ramachandran ; Kannaiyan, Dinakaran</creatorcontrib><description>In this research, an electrochemical sensor was fabricated employing the metal-organic framework (MOF) deposited glassy carbon electrode (GCE) for the sensing copper ions in water with high sensitivity. The porous nanostructured MOF was characterized through Transmission electron microscope, scanning electron microscope and X-ray diffraction analysis. The Bi-MOF nanostructure deposited GCE (Bi-MOF/GCE) was fabricated by drop-casting a suspension of Bi-MOF in water on GCE surface. The performance of modified electrode in the presence and absence of heavy metal ions such as Cd2+, Hg2+ As3+, Pb2+ and Cu2+ was determined by the cyclic voltammetry in deionised water within the scan rate range of 25 and 300 mVs−1. The Bi-MOF/GCE displayed highest anodic and cathodic peak current for Cu2+ ions than other metal ions, which was enhanced linearly within the scan rate range of 10–100 mV s−1. Under the employed experimental conditions, the fabricated Bi-MOF/GCE based electrochemical sensor showed an outstanding routine in the determination of copper with a lowest sensing limit of 1 × 10−5 M, wide linear range variation, strong interaction between metal ions and Bi-MOF. It has long-term stability and good reproducibility. The Bi-MOF/GCE electrode was successfully tested to detect Cu2+ in tap water with acceptable results.</description><identifier>ISSN: 0278-6915</identifier><identifier>EISSN: 1873-6351</identifier><identifier>DOI: 10.1016/j.fct.2022.113313</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Bi-MOF ; Copper sensor ; Electrochemical metal sensor ; Heavy metal sensor ; Metal oxide frameworks ; Modified GCE</subject><ispartof>Food and chemical toxicology, 2022-09, Vol.167, p.113313-113313, Article 113313</ispartof><rights>2022 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c260t-7473960185b93958c432fe0bcf46276eb6b9c6eb18c63d231512e8593d4842253</citedby><cites>FETCH-LOGICAL-c260t-7473960185b93958c432fe0bcf46276eb6b9c6eb18c63d231512e8593d4842253</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.fct.2022.113313$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids></links><search><creatorcontrib>Theerthagiri, Senthil</creatorcontrib><creatorcontrib>Rajkannu, Parkavi</creatorcontrib><creatorcontrib>Senthil Kumar, P.</creatorcontrib><creatorcontrib>Peethambaram, Prabukanthan</creatorcontrib><creatorcontrib>Ayyavu, Chandramohan</creatorcontrib><creatorcontrib>Rasu, Ramachandran</creatorcontrib><creatorcontrib>Kannaiyan, Dinakaran</creatorcontrib><title>Electrochemical sensing of copper (II) ion in water using bi-metal oxide framework modified glassy carbon electrode</title><title>Food and chemical toxicology</title><description>In this research, an electrochemical sensor was fabricated employing the metal-organic framework (MOF) deposited glassy carbon electrode (GCE) for the sensing copper ions in water with high sensitivity. The porous nanostructured MOF was characterized through Transmission electron microscope, scanning electron microscope and X-ray diffraction analysis. The Bi-MOF nanostructure deposited GCE (Bi-MOF/GCE) was fabricated by drop-casting a suspension of Bi-MOF in water on GCE surface. The performance of modified electrode in the presence and absence of heavy metal ions such as Cd2+, Hg2+ As3+, Pb2+ and Cu2+ was determined by the cyclic voltammetry in deionised water within the scan rate range of 25 and 300 mVs−1. The Bi-MOF/GCE displayed highest anodic and cathodic peak current for Cu2+ ions than other metal ions, which was enhanced linearly within the scan rate range of 10–100 mV s−1. Under the employed experimental conditions, the fabricated Bi-MOF/GCE based electrochemical sensor showed an outstanding routine in the determination of copper with a lowest sensing limit of 1 × 10−5 M, wide linear range variation, strong interaction between metal ions and Bi-MOF. It has long-term stability and good reproducibility. The Bi-MOF/GCE electrode was successfully tested to detect Cu2+ in tap water with acceptable results.</description><subject>Bi-MOF</subject><subject>Copper sensor</subject><subject>Electrochemical metal sensor</subject><subject>Heavy metal sensor</subject><subject>Metal oxide frameworks</subject><subject>Modified GCE</subject><issn>0278-6915</issn><issn>1873-6351</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kD1PwzAQhi0EEqXwA9g8liHBH4mTiAlVBSpVYoHZcuxLcUniYKeU_nsMYWZ6pdP73OkehK4pSSmh4naXNnpMGWEspZRzyk_QjJYFTwTP6SmaEVaUiahofo4uQtgRQgpaiBkKqxb06J1-g85q1eIAfbD9FrsGazcM4PFivb7B1vXY9vigxjjZ_zZqm3QwRsR9WQO48aqDg_PvuHPGNhYM3rYqhCPWytcRh-mSgUt01qg2wNVfztHrw-pl-ZRsnh_Xy_tNopkgY1JkBa8EoWVeV7zKS51x1gCpdZMJVgioRV3pGLTUghvGaU4ZlHnFTVZmjOV8jhbT3sG7jz2EUXY2aGhb1YPbB8lElWWR4mWs0qmqvQvBQyMHbzvlj5IS-SNY7mQULH8Ey0lwZO4mBuIPnxa8DNpCr8FYHz-Vxtl_6G88L4Lp</recordid><startdate>202209</startdate><enddate>202209</enddate><creator>Theerthagiri, Senthil</creator><creator>Rajkannu, Parkavi</creator><creator>Senthil Kumar, P.</creator><creator>Peethambaram, Prabukanthan</creator><creator>Ayyavu, Chandramohan</creator><creator>Rasu, Ramachandran</creator><creator>Kannaiyan, Dinakaran</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202209</creationdate><title>Electrochemical sensing of copper (II) ion in water using bi-metal oxide framework modified glassy carbon electrode</title><author>Theerthagiri, Senthil ; Rajkannu, Parkavi ; Senthil Kumar, P. ; Peethambaram, Prabukanthan ; Ayyavu, Chandramohan ; Rasu, Ramachandran ; Kannaiyan, Dinakaran</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c260t-7473960185b93958c432fe0bcf46276eb6b9c6eb18c63d231512e8593d4842253</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Bi-MOF</topic><topic>Copper sensor</topic><topic>Electrochemical metal sensor</topic><topic>Heavy metal sensor</topic><topic>Metal oxide frameworks</topic><topic>Modified GCE</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Theerthagiri, Senthil</creatorcontrib><creatorcontrib>Rajkannu, Parkavi</creatorcontrib><creatorcontrib>Senthil Kumar, P.</creatorcontrib><creatorcontrib>Peethambaram, Prabukanthan</creatorcontrib><creatorcontrib>Ayyavu, Chandramohan</creatorcontrib><creatorcontrib>Rasu, Ramachandran</creatorcontrib><creatorcontrib>Kannaiyan, Dinakaran</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Food and chemical toxicology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Theerthagiri, Senthil</au><au>Rajkannu, Parkavi</au><au>Senthil Kumar, P.</au><au>Peethambaram, Prabukanthan</au><au>Ayyavu, Chandramohan</au><au>Rasu, Ramachandran</au><au>Kannaiyan, Dinakaran</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrochemical sensing of copper (II) ion in water using bi-metal oxide framework modified glassy carbon electrode</atitle><jtitle>Food and chemical toxicology</jtitle><date>2022-09</date><risdate>2022</risdate><volume>167</volume><spage>113313</spage><epage>113313</epage><pages>113313-113313</pages><artnum>113313</artnum><issn>0278-6915</issn><eissn>1873-6351</eissn><abstract>In this research, an electrochemical sensor was fabricated employing the metal-organic framework (MOF) deposited glassy carbon electrode (GCE) for the sensing copper ions in water with high sensitivity. The porous nanostructured MOF was characterized through Transmission electron microscope, scanning electron microscope and X-ray diffraction analysis. The Bi-MOF nanostructure deposited GCE (Bi-MOF/GCE) was fabricated by drop-casting a suspension of Bi-MOF in water on GCE surface. The performance of modified electrode in the presence and absence of heavy metal ions such as Cd2+, Hg2+ As3+, Pb2+ and Cu2+ was determined by the cyclic voltammetry in deionised water within the scan rate range of 25 and 300 mVs−1. The Bi-MOF/GCE displayed highest anodic and cathodic peak current for Cu2+ ions than other metal ions, which was enhanced linearly within the scan rate range of 10–100 mV s−1. Under the employed experimental conditions, the fabricated Bi-MOF/GCE based electrochemical sensor showed an outstanding routine in the determination of copper with a lowest sensing limit of 1 × 10−5 M, wide linear range variation, strong interaction between metal ions and Bi-MOF. It has long-term stability and good reproducibility. The Bi-MOF/GCE electrode was successfully tested to detect Cu2+ in tap water with acceptable results.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.fct.2022.113313</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0278-6915
ispartof Food and chemical toxicology, 2022-09, Vol.167, p.113313-113313, Article 113313
issn 0278-6915
1873-6351
language eng
recordid cdi_proquest_miscellaneous_2694415138
source Elsevier ScienceDirect Journals Complete
subjects Bi-MOF
Copper sensor
Electrochemical metal sensor
Heavy metal sensor
Metal oxide frameworks
Modified GCE
title Electrochemical sensing of copper (II) ion in water using bi-metal oxide framework modified glassy carbon electrode
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T16%3A39%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrochemical%20sensing%20of%20copper%20(II)%20ion%20in%20water%20using%20bi-metal%20oxide%20framework%20modified%20glassy%20carbon%20electrode&rft.jtitle=Food%20and%20chemical%20toxicology&rft.au=Theerthagiri,%20Senthil&rft.date=2022-09&rft.volume=167&rft.spage=113313&rft.epage=113313&rft.pages=113313-113313&rft.artnum=113313&rft.issn=0278-6915&rft.eissn=1873-6351&rft_id=info:doi/10.1016/j.fct.2022.113313&rft_dat=%3Cproquest_cross%3E2694415138%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2694415138&rft_id=info:pmid/&rft_els_id=S0278691522005117&rfr_iscdi=true