Rotor-stator interaction in a centrifugal pump equipped with a vaned diffuser

Abstract This paper provides the results of a detailed flow investigation within a centrifugal pump equipped with a vaned diffuser. The measurements made with a laser Doppler velocimeter were carried out at two operating points. Unsteady velocity measurements obtained in phase with the impeller angu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Proceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy Journal of power and energy, 2001-01, Vol.215 (6), p.809-817
Hauptverfasser: El Hajem, M, Akhras, A, Champagne, J. Y., Morel, R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 817
container_issue 6
container_start_page 809
container_title Proceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy
container_volume 215
creator El Hajem, M
Akhras, A
Champagne, J. Y.
Morel, R
description Abstract This paper provides the results of a detailed flow investigation within a centrifugal pump equipped with a vaned diffuser. The measurements made with a laser Doppler velocimeter were carried out at two operating points. Unsteady velocity measurements obtained in phase with the impeller angular position gave access to the relative flow within the impeller channels. Measurements were obtained in the impeller and the diffuser at different measuring planes relative to the diffuser vanes. Results are presented as animations reconstituting a temporal evolution of the flow permitting a better comprehension of the complex flow structure existing between the two interacting blade rows. The analysis of the relative flow field indicates the presence of a jet wake structure. The wake is characterized by low relative velocities localized in the suction side-shroud corner. At the design flowrate, the presence of the vanes seems to have a limited effect on the impeller flow structure, except when the suction side of the blades is facing the diffuser vanes. At the impeller discharge, the time-resolved sequences show that the mixing process of the unsteady and periodic flow leaving the impeller is affected by the presence of the diffuser.
doi_str_mv 10.1243/0957650011538947
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_26938400</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1243_0957650011538947</sage_id><sourcerecordid>26938400</sourcerecordid><originalsourceid>FETCH-LOGICAL-c367t-2717777bcfa8e71cb1e304cb770cd4327a91643f311a21a14c67d0e707d512fa3</originalsourceid><addsrcrecordid>eNp1kE1LAzEQhoMoWKt3j4ugt9VMkt00Ryl-QUUQPS_TbFJTtrvbJKv4701poVBwLjPDPPPO8BJyCfQWmOB3VBWyLCgFKPhECXlERowKyJkq5TEZbcZ5mqtTchbCkqYoJBuR1_cudj4PEVPKXBuNRx1d16Y6w0ybNnpnhwU2WT-s-sysB9f3ps5-XPxKwDe2qamdtUMw_pycWGyCudjlMfl8fPiYPuezt6eX6f0s17yUMWcSZIq5tjgxEvQcDKdCz6WkuhacSVRQCm45ADJAELqUNTWSyroAZpGPyc1Wt_fdejAhVisXtGma9E03hIqVik8EpQm8OgCX3eDb9FvFQIGSBUCC6BbSvgvBG1v13q3Q_1ZAq4251aG5aeV6p4tBY2M9ttqF_R4XnPJJkbh8ywVcmP3tf3X_AO89hPM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>219197511</pqid></control><display><type>article</type><title>Rotor-stator interaction in a centrifugal pump equipped with a vaned diffuser</title><source>Access via SAGE</source><creator>El Hajem, M ; Akhras, A ; Champagne, J. Y. ; Morel, R</creator><creatorcontrib>El Hajem, M ; Akhras, A ; Champagne, J. Y. ; Morel, R</creatorcontrib><description>Abstract This paper provides the results of a detailed flow investigation within a centrifugal pump equipped with a vaned diffuser. The measurements made with a laser Doppler velocimeter were carried out at two operating points. Unsteady velocity measurements obtained in phase with the impeller angular position gave access to the relative flow within the impeller channels. Measurements were obtained in the impeller and the diffuser at different measuring planes relative to the diffuser vanes. Results are presented as animations reconstituting a temporal evolution of the flow permitting a better comprehension of the complex flow structure existing between the two interacting blade rows. The analysis of the relative flow field indicates the presence of a jet wake structure. The wake is characterized by low relative velocities localized in the suction side-shroud corner. At the design flowrate, the presence of the vanes seems to have a limited effect on the impeller flow structure, except when the suction side of the blades is facing the diffuser vanes. At the impeller discharge, the time-resolved sequences show that the mixing process of the unsteady and periodic flow leaving the impeller is affected by the presence of the diffuser.</description><identifier>ISSN: 0957-6509</identifier><identifier>EISSN: 2041-2967</identifier><identifier>DOI: 10.1243/0957650011538947</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Applied sciences ; Energy ; Energy. Thermal use of fuels ; Engines and turbines ; Equipments for energy generation and conversion: thermal, electrical, mechanical energy, etc ; Exact sciences and technology</subject><ispartof>Proceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy, 2001-01, Vol.215 (6), p.809-817</ispartof><rights>2001 Institution of Mechanical Engineers</rights><rights>2002 INIST-CNRS</rights><rights>Copyright Mechanical Engineering Publications, Ltd. 2001</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c367t-2717777bcfa8e71cb1e304cb770cd4327a91643f311a21a14c67d0e707d512fa3</citedby><cites>FETCH-LOGICAL-c367t-2717777bcfa8e71cb1e304cb770cd4327a91643f311a21a14c67d0e707d512fa3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1243/0957650011538947$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1243/0957650011538947$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=13430385$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>El Hajem, M</creatorcontrib><creatorcontrib>Akhras, A</creatorcontrib><creatorcontrib>Champagne, J. Y.</creatorcontrib><creatorcontrib>Morel, R</creatorcontrib><title>Rotor-stator interaction in a centrifugal pump equipped with a vaned diffuser</title><title>Proceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy</title><description>Abstract This paper provides the results of a detailed flow investigation within a centrifugal pump equipped with a vaned diffuser. The measurements made with a laser Doppler velocimeter were carried out at two operating points. Unsteady velocity measurements obtained in phase with the impeller angular position gave access to the relative flow within the impeller channels. Measurements were obtained in the impeller and the diffuser at different measuring planes relative to the diffuser vanes. Results are presented as animations reconstituting a temporal evolution of the flow permitting a better comprehension of the complex flow structure existing between the two interacting blade rows. The analysis of the relative flow field indicates the presence of a jet wake structure. The wake is characterized by low relative velocities localized in the suction side-shroud corner. At the design flowrate, the presence of the vanes seems to have a limited effect on the impeller flow structure, except when the suction side of the blades is facing the diffuser vanes. At the impeller discharge, the time-resolved sequences show that the mixing process of the unsteady and periodic flow leaving the impeller is affected by the presence of the diffuser.</description><subject>Applied sciences</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Engines and turbines</subject><subject>Equipments for energy generation and conversion: thermal, electrical, mechanical energy, etc</subject><subject>Exact sciences and technology</subject><issn>0957-6509</issn><issn>2041-2967</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNp1kE1LAzEQhoMoWKt3j4ugt9VMkt00Ryl-QUUQPS_TbFJTtrvbJKv4701poVBwLjPDPPPO8BJyCfQWmOB3VBWyLCgFKPhECXlERowKyJkq5TEZbcZ5mqtTchbCkqYoJBuR1_cudj4PEVPKXBuNRx1d16Y6w0ybNnpnhwU2WT-s-sysB9f3ps5-XPxKwDe2qamdtUMw_pycWGyCudjlMfl8fPiYPuezt6eX6f0s17yUMWcSZIq5tjgxEvQcDKdCz6WkuhacSVRQCm45ADJAELqUNTWSyroAZpGPyc1Wt_fdejAhVisXtGma9E03hIqVik8EpQm8OgCX3eDb9FvFQIGSBUCC6BbSvgvBG1v13q3Q_1ZAq4251aG5aeV6p4tBY2M9ttqF_R4XnPJJkbh8ywVcmP3tf3X_AO89hPM</recordid><startdate>20010101</startdate><enddate>20010101</enddate><creator>El Hajem, M</creator><creator>Akhras, A</creator><creator>Champagne, J. Y.</creator><creator>Morel, R</creator><general>SAGE Publications</general><general>Professionnal Engineering Publishing</general><general>SAGE PUBLICATIONS, INC</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7SP</scope><scope>7TB</scope><scope>7XB</scope><scope>88I</scope><scope>8AF</scope><scope>8AO</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>F28</scope><scope>FR3</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>KR7</scope><scope>L6V</scope><scope>L7M</scope><scope>M2P</scope><scope>M7S</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PTHSS</scope><scope>Q9U</scope></search><sort><creationdate>20010101</creationdate><title>Rotor-stator interaction in a centrifugal pump equipped with a vaned diffuser</title><author>El Hajem, M ; Akhras, A ; Champagne, J. Y. ; Morel, R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c367t-2717777bcfa8e71cb1e304cb770cd4327a91643f311a21a14c67d0e707d512fa3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Applied sciences</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Engines and turbines</topic><topic>Equipments for energy generation and conversion: thermal, electrical, mechanical energy, etc</topic><topic>Exact sciences and technology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>El Hajem, M</creatorcontrib><creatorcontrib>Akhras, A</creatorcontrib><creatorcontrib>Champagne, J. Y.</creatorcontrib><creatorcontrib>Morel, R</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Science Database (Alumni Edition)</collection><collection>STEM Database</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Science Database</collection><collection>Engineering Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>Engineering Collection</collection><collection>ProQuest Central Basic</collection><jtitle>Proceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>El Hajem, M</au><au>Akhras, A</au><au>Champagne, J. Y.</au><au>Morel, R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rotor-stator interaction in a centrifugal pump equipped with a vaned diffuser</atitle><jtitle>Proceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy</jtitle><date>2001-01-01</date><risdate>2001</risdate><volume>215</volume><issue>6</issue><spage>809</spage><epage>817</epage><pages>809-817</pages><issn>0957-6509</issn><eissn>2041-2967</eissn><abstract>Abstract This paper provides the results of a detailed flow investigation within a centrifugal pump equipped with a vaned diffuser. The measurements made with a laser Doppler velocimeter were carried out at two operating points. Unsteady velocity measurements obtained in phase with the impeller angular position gave access to the relative flow within the impeller channels. Measurements were obtained in the impeller and the diffuser at different measuring planes relative to the diffuser vanes. Results are presented as animations reconstituting a temporal evolution of the flow permitting a better comprehension of the complex flow structure existing between the two interacting blade rows. The analysis of the relative flow field indicates the presence of a jet wake structure. The wake is characterized by low relative velocities localized in the suction side-shroud corner. At the design flowrate, the presence of the vanes seems to have a limited effect on the impeller flow structure, except when the suction side of the blades is facing the diffuser vanes. At the impeller discharge, the time-resolved sequences show that the mixing process of the unsteady and periodic flow leaving the impeller is affected by the presence of the diffuser.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1243/0957650011538947</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0957-6509
ispartof Proceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy, 2001-01, Vol.215 (6), p.809-817
issn 0957-6509
2041-2967
language eng
recordid cdi_proquest_miscellaneous_26938400
source Access via SAGE
subjects Applied sciences
Energy
Energy. Thermal use of fuels
Engines and turbines
Equipments for energy generation and conversion: thermal, electrical, mechanical energy, etc
Exact sciences and technology
title Rotor-stator interaction in a centrifugal pump equipped with a vaned diffuser
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T04%3A11%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rotor-stator%20interaction%20in%20a%20centrifugal%20pump%20equipped%20with%20a%20vaned%20diffuser&rft.jtitle=Proceedings%20of%20the%20Institution%20of%20Mechanical%20Engineers.%20Part%20A,%20Journal%20of%20power%20and%20energy&rft.au=El%20Hajem,%20M&rft.date=2001-01-01&rft.volume=215&rft.issue=6&rft.spage=809&rft.epage=817&rft.pages=809-817&rft.issn=0957-6509&rft.eissn=2041-2967&rft_id=info:doi/10.1243/0957650011538947&rft_dat=%3Cproquest_cross%3E26938400%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=219197511&rft_id=info:pmid/&rft_sage_id=10.1243_0957650011538947&rfr_iscdi=true