3D ultrasonic imaging of surface-breaking cracks using a linear array

Ultrasonic linear arrays have great potential to generate high-quality three-dimensional (3D) images by scanning the array. However, the generated images suffer from low resolution in the elevation plane, limiting the image quality for a reliable 3D Non-Destructive Testing (NDT) inspection. Although...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ultrasonics 2022-09, Vol.125, p.106790-106790, Article 106790
Hauptverfasser: Saini, Abhishek, Lane, Christopher J.L., Tu, Juan, Xue, Honghui, Fan, Zheng
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 106790
container_issue
container_start_page 106790
container_title Ultrasonics
container_volume 125
creator Saini, Abhishek
Lane, Christopher J.L.
Tu, Juan
Xue, Honghui
Fan, Zheng
description Ultrasonic linear arrays have great potential to generate high-quality three-dimensional (3D) images by scanning the array. However, the generated images suffer from low resolution in the elevation plane, limiting the image quality for a reliable 3D Non-Destructive Testing (NDT) inspection. Although several ultrasonic imaging methods have been implemented to inspect different types of defects, there has been limited research to characterise surface-breaking cracks (SBCs) in 3D quantitatively. To improve the characterisation of surface-breaking cracks (SBCs), a 3D hybrid imaging method is proposed by combining the Half Skip Total Focusing Method (HSTFM) and the Synthetic Aperture Focusing Technique (SAFT) using a linear array. This paper proposed the implementation of an array with a reduced element length for full matrix capture (FMC) data acquisition. In conjunction with the hybrid imaging method, a reduced element array enables the utilisation of the information from a broad ultrasonic beam in the elevation direction to achieve improved image resolution. The imaging capability is assessed via a point spread function (PSF) as well as numerical simulations. From the PSF measurements, the image resolution is shown to improve with the smaller element length of the array, which is attributable to the combination of wide beamwidth and hybrid imaging method. Thereafter, experimental validation was performed with arrays of different elevation lengths, where an excellent match with the numerical results was observed. Furthermore, the crack sizing was performed using a 6-dB-drop rule, which assisted in accurately predicting the shape and size of the SBCs and is shown to measure the depth of SBCs with greater confidence. It is shown that a reduced array elevation with the hybrid imaging method and sizing method yields improved image resolution contrary to conventional linear arrays. This approach can offer a significant improvement in manifesting complete comprehension of the spatial defect relationship, enabling NDT engineers to analyse the inspection results quantitatively in 3D for progressive reliability. •3D ultrasonic imaging of surface-breaking cracks.•Improved image capability with a hybrid technique combining Half Skip Total Focusing Method (HSTFM) and Synthetic Aperture Focusing Technique (SAFT).•Image resolution improved with reduced array elevation.
doi_str_mv 10.1016/j.ultras.2022.106790
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2691054271</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0041624X22000968</els_id><sourcerecordid>2691054271</sourcerecordid><originalsourceid>FETCH-LOGICAL-c385t-837f0ec397dc4152ddc29c45301a152f6d0ecedc754bba4824c71a7f1b5da643</originalsourceid><addsrcrecordid>eNp9UMtOwzAQtBBIlMIfcMiRS4JfiZMLEirlIVXi0gM3a7OxK7dpUuwEqX-Po3DmtJrdmdHOEHLPaMYoKx732dgOHkLGKedxVaiKXpAFK5VMq6ooL8mCUsnSgsuva3ITwp5SJksmFmQtXpJZ3HcOE3eEnet2SW-TMHoLaNLaGzhMO_SAh5CMYQKQtK4z4BPwHs635MpCG8zd31yS7et6u3pPN59vH6vnTYqizIe0FMpSg6JSDUqW86ZBXqHMBWUQoS2aeDUNqlzWNciSS1QMlGV13kAhxZI8zLYn33-PJgz66AKatoXO9GPQvKgYzSVXLFLlTEXfh-CN1Scfw_mzZlRPpem9nnPrqTQ9lxZlT7PMxBQ_zngd0JkuPuW8wUE3vfvf4BdrlHd_</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2691054271</pqid></control><display><type>article</type><title>3D ultrasonic imaging of surface-breaking cracks using a linear array</title><source>Access via ScienceDirect (Elsevier)</source><creator>Saini, Abhishek ; Lane, Christopher J.L. ; Tu, Juan ; Xue, Honghui ; Fan, Zheng</creator><creatorcontrib>Saini, Abhishek ; Lane, Christopher J.L. ; Tu, Juan ; Xue, Honghui ; Fan, Zheng</creatorcontrib><description>Ultrasonic linear arrays have great potential to generate high-quality three-dimensional (3D) images by scanning the array. However, the generated images suffer from low resolution in the elevation plane, limiting the image quality for a reliable 3D Non-Destructive Testing (NDT) inspection. Although several ultrasonic imaging methods have been implemented to inspect different types of defects, there has been limited research to characterise surface-breaking cracks (SBCs) in 3D quantitatively. To improve the characterisation of surface-breaking cracks (SBCs), a 3D hybrid imaging method is proposed by combining the Half Skip Total Focusing Method (HSTFM) and the Synthetic Aperture Focusing Technique (SAFT) using a linear array. This paper proposed the implementation of an array with a reduced element length for full matrix capture (FMC) data acquisition. In conjunction with the hybrid imaging method, a reduced element array enables the utilisation of the information from a broad ultrasonic beam in the elevation direction to achieve improved image resolution. The imaging capability is assessed via a point spread function (PSF) as well as numerical simulations. From the PSF measurements, the image resolution is shown to improve with the smaller element length of the array, which is attributable to the combination of wide beamwidth and hybrid imaging method. Thereafter, experimental validation was performed with arrays of different elevation lengths, where an excellent match with the numerical results was observed. Furthermore, the crack sizing was performed using a 6-dB-drop rule, which assisted in accurately predicting the shape and size of the SBCs and is shown to measure the depth of SBCs with greater confidence. It is shown that a reduced array elevation with the hybrid imaging method and sizing method yields improved image resolution contrary to conventional linear arrays. This approach can offer a significant improvement in manifesting complete comprehension of the spatial defect relationship, enabling NDT engineers to analyse the inspection results quantitatively in 3D for progressive reliability. •3D ultrasonic imaging of surface-breaking cracks.•Improved image capability with a hybrid technique combining Half Skip Total Focusing Method (HSTFM) and Synthetic Aperture Focusing Technique (SAFT).•Image resolution improved with reduced array elevation.</description><identifier>ISSN: 0041-624X</identifier><identifier>EISSN: 1874-9968</identifier><identifier>DOI: 10.1016/j.ultras.2022.106790</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>3D imaging ; HSTFM ; Industrial NDT ; Linear array ; Phased array resolution ; SAFT</subject><ispartof>Ultrasonics, 2022-09, Vol.125, p.106790-106790, Article 106790</ispartof><rights>2022 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c385t-837f0ec397dc4152ddc29c45301a152f6d0ecedc754bba4824c71a7f1b5da643</citedby><cites>FETCH-LOGICAL-c385t-837f0ec397dc4152ddc29c45301a152f6d0ecedc754bba4824c71a7f1b5da643</cites><orcidid>0000-0002-7818-153X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.ultras.2022.106790$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Saini, Abhishek</creatorcontrib><creatorcontrib>Lane, Christopher J.L.</creatorcontrib><creatorcontrib>Tu, Juan</creatorcontrib><creatorcontrib>Xue, Honghui</creatorcontrib><creatorcontrib>Fan, Zheng</creatorcontrib><title>3D ultrasonic imaging of surface-breaking cracks using a linear array</title><title>Ultrasonics</title><description>Ultrasonic linear arrays have great potential to generate high-quality three-dimensional (3D) images by scanning the array. However, the generated images suffer from low resolution in the elevation plane, limiting the image quality for a reliable 3D Non-Destructive Testing (NDT) inspection. Although several ultrasonic imaging methods have been implemented to inspect different types of defects, there has been limited research to characterise surface-breaking cracks (SBCs) in 3D quantitatively. To improve the characterisation of surface-breaking cracks (SBCs), a 3D hybrid imaging method is proposed by combining the Half Skip Total Focusing Method (HSTFM) and the Synthetic Aperture Focusing Technique (SAFT) using a linear array. This paper proposed the implementation of an array with a reduced element length for full matrix capture (FMC) data acquisition. In conjunction with the hybrid imaging method, a reduced element array enables the utilisation of the information from a broad ultrasonic beam in the elevation direction to achieve improved image resolution. The imaging capability is assessed via a point spread function (PSF) as well as numerical simulations. From the PSF measurements, the image resolution is shown to improve with the smaller element length of the array, which is attributable to the combination of wide beamwidth and hybrid imaging method. Thereafter, experimental validation was performed with arrays of different elevation lengths, where an excellent match with the numerical results was observed. Furthermore, the crack sizing was performed using a 6-dB-drop rule, which assisted in accurately predicting the shape and size of the SBCs and is shown to measure the depth of SBCs with greater confidence. It is shown that a reduced array elevation with the hybrid imaging method and sizing method yields improved image resolution contrary to conventional linear arrays. This approach can offer a significant improvement in manifesting complete comprehension of the spatial defect relationship, enabling NDT engineers to analyse the inspection results quantitatively in 3D for progressive reliability. •3D ultrasonic imaging of surface-breaking cracks.•Improved image capability with a hybrid technique combining Half Skip Total Focusing Method (HSTFM) and Synthetic Aperture Focusing Technique (SAFT).•Image resolution improved with reduced array elevation.</description><subject>3D imaging</subject><subject>HSTFM</subject><subject>Industrial NDT</subject><subject>Linear array</subject><subject>Phased array resolution</subject><subject>SAFT</subject><issn>0041-624X</issn><issn>1874-9968</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9UMtOwzAQtBBIlMIfcMiRS4JfiZMLEirlIVXi0gM3a7OxK7dpUuwEqX-Po3DmtJrdmdHOEHLPaMYoKx732dgOHkLGKedxVaiKXpAFK5VMq6ooL8mCUsnSgsuva3ITwp5SJksmFmQtXpJZ3HcOE3eEnet2SW-TMHoLaNLaGzhMO_SAh5CMYQKQtK4z4BPwHs635MpCG8zd31yS7et6u3pPN59vH6vnTYqizIe0FMpSg6JSDUqW86ZBXqHMBWUQoS2aeDUNqlzWNciSS1QMlGV13kAhxZI8zLYn33-PJgz66AKatoXO9GPQvKgYzSVXLFLlTEXfh-CN1Scfw_mzZlRPpem9nnPrqTQ9lxZlT7PMxBQ_zngd0JkuPuW8wUE3vfvf4BdrlHd_</recordid><startdate>202209</startdate><enddate>202209</enddate><creator>Saini, Abhishek</creator><creator>Lane, Christopher J.L.</creator><creator>Tu, Juan</creator><creator>Xue, Honghui</creator><creator>Fan, Zheng</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-7818-153X</orcidid></search><sort><creationdate>202209</creationdate><title>3D ultrasonic imaging of surface-breaking cracks using a linear array</title><author>Saini, Abhishek ; Lane, Christopher J.L. ; Tu, Juan ; Xue, Honghui ; Fan, Zheng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c385t-837f0ec397dc4152ddc29c45301a152f6d0ecedc754bba4824c71a7f1b5da643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>3D imaging</topic><topic>HSTFM</topic><topic>Industrial NDT</topic><topic>Linear array</topic><topic>Phased array resolution</topic><topic>SAFT</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Saini, Abhishek</creatorcontrib><creatorcontrib>Lane, Christopher J.L.</creatorcontrib><creatorcontrib>Tu, Juan</creatorcontrib><creatorcontrib>Xue, Honghui</creatorcontrib><creatorcontrib>Fan, Zheng</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Ultrasonics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Saini, Abhishek</au><au>Lane, Christopher J.L.</au><au>Tu, Juan</au><au>Xue, Honghui</au><au>Fan, Zheng</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>3D ultrasonic imaging of surface-breaking cracks using a linear array</atitle><jtitle>Ultrasonics</jtitle><date>2022-09</date><risdate>2022</risdate><volume>125</volume><spage>106790</spage><epage>106790</epage><pages>106790-106790</pages><artnum>106790</artnum><issn>0041-624X</issn><eissn>1874-9968</eissn><abstract>Ultrasonic linear arrays have great potential to generate high-quality three-dimensional (3D) images by scanning the array. However, the generated images suffer from low resolution in the elevation plane, limiting the image quality for a reliable 3D Non-Destructive Testing (NDT) inspection. Although several ultrasonic imaging methods have been implemented to inspect different types of defects, there has been limited research to characterise surface-breaking cracks (SBCs) in 3D quantitatively. To improve the characterisation of surface-breaking cracks (SBCs), a 3D hybrid imaging method is proposed by combining the Half Skip Total Focusing Method (HSTFM) and the Synthetic Aperture Focusing Technique (SAFT) using a linear array. This paper proposed the implementation of an array with a reduced element length for full matrix capture (FMC) data acquisition. In conjunction with the hybrid imaging method, a reduced element array enables the utilisation of the information from a broad ultrasonic beam in the elevation direction to achieve improved image resolution. The imaging capability is assessed via a point spread function (PSF) as well as numerical simulations. From the PSF measurements, the image resolution is shown to improve with the smaller element length of the array, which is attributable to the combination of wide beamwidth and hybrid imaging method. Thereafter, experimental validation was performed with arrays of different elevation lengths, where an excellent match with the numerical results was observed. Furthermore, the crack sizing was performed using a 6-dB-drop rule, which assisted in accurately predicting the shape and size of the SBCs and is shown to measure the depth of SBCs with greater confidence. It is shown that a reduced array elevation with the hybrid imaging method and sizing method yields improved image resolution contrary to conventional linear arrays. This approach can offer a significant improvement in manifesting complete comprehension of the spatial defect relationship, enabling NDT engineers to analyse the inspection results quantitatively in 3D for progressive reliability. •3D ultrasonic imaging of surface-breaking cracks.•Improved image capability with a hybrid technique combining Half Skip Total Focusing Method (HSTFM) and Synthetic Aperture Focusing Technique (SAFT).•Image resolution improved with reduced array elevation.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.ultras.2022.106790</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0002-7818-153X</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0041-624X
ispartof Ultrasonics, 2022-09, Vol.125, p.106790-106790, Article 106790
issn 0041-624X
1874-9968
language eng
recordid cdi_proquest_miscellaneous_2691054271
source Access via ScienceDirect (Elsevier)
subjects 3D imaging
HSTFM
Industrial NDT
Linear array
Phased array resolution
SAFT
title 3D ultrasonic imaging of surface-breaking cracks using a linear array
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T19%3A00%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=3D%20ultrasonic%20imaging%20of%20surface-breaking%20cracks%20using%20a%20linear%20array&rft.jtitle=Ultrasonics&rft.au=Saini,%20Abhishek&rft.date=2022-09&rft.volume=125&rft.spage=106790&rft.epage=106790&rft.pages=106790-106790&rft.artnum=106790&rft.issn=0041-624X&rft.eissn=1874-9968&rft_id=info:doi/10.1016/j.ultras.2022.106790&rft_dat=%3Cproquest_cross%3E2691054271%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2691054271&rft_id=info:pmid/&rft_els_id=S0041624X22000968&rfr_iscdi=true