Deeper may not be better: relationship between catheter dysfunction and location of the catheter tip in right-sided tunnelled haemodialysis catheters

To examine the relationship between catheter tip location and catheter dysfunction in the context of tunnelled central venous catheters (CVCs) for haemodialysis. This was a retrospective study of 993 haemodialysis patients who underwent insertion of tunnelled CVCs of step-tip design via the right in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical radiology 2022-09, Vol.77 (9), p.678-683
Hauptverfasser: Soh, N.Y.T., Tan, B.S., Chan, S.J.M., Patel, A., Gogna, A., Zhuang, K.D., Tashi, S., Venkatanarasimha, N., Tay, K.H., Chandramohan, S.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 683
container_issue 9
container_start_page 678
container_title Clinical radiology
container_volume 77
creator Soh, N.Y.T.
Tan, B.S.
Chan, S.J.M.
Patel, A.
Gogna, A.
Zhuang, K.D.
Tashi, S.
Venkatanarasimha, N.
Tay, K.H.
Chandramohan, S.
description To examine the relationship between catheter tip location and catheter dysfunction in the context of tunnelled central venous catheters (CVCs) for haemodialysis. This was a retrospective study of 993 haemodialysis patients who underwent insertion of tunnelled CVCs of step-tip design via the right internal jugular vein (IJV). Based on intra-procedural radiographs, the catheter tip was characterised as being in the superior vena cava (SVC), cavo-atrial junction (CAJ), or deep right atrium (DRA). Patients were tracked for 90 days post-procedure for complications resulting in catheter replacement, and these were compared between cohorts. Statistical analysis was performed with Pearson's chi-square and Fisher's exact tests for categorical variables and two-sample t-test and one-way analysis of variance (ANOVA) for continuous variables. Ninety-five patients (9.6%) experienced catheter dysfunction necessitating replacement within 90 days of insertion. Tip location in SVC was associated with lower occurrence of catheter dysfunction (1.9%) as compared with the CAJ (8%) and DRA (11%; p=0.049). Catheter replacement due to other complications (catheter-associated bacteraemia, cuff dislodgement, exit-site infection, external catheter damage) showed no statistically significant relation to location of the CVC tip. When utilising tunnelled CVCs with a step-tip design inserted via the right IJV, location of the catheter tip in the SVC is associated with reduced occurrence of catheter dysfunction as compared to either the CAJ or DRA. •CVC tip in the SVC is associated with lower incidence of catheter dysfunction.•In the context of tunneled CVCs for haemodialysis•When utilising a step-tip catheter design inserted via the right IJV•Largest study to date examining this relationship
doi_str_mv 10.1016/j.crad.2022.04.020
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2678426570</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S000992602200229X</els_id><sourcerecordid>2678426570</sourcerecordid><originalsourceid>FETCH-LOGICAL-c333t-3aaf06596a1894077a9676602e05f2458c742dfe1bb14861430e1b74a16af4a33</originalsourceid><addsrcrecordid>eNp9kc-KFDEQh4MoOK77AnvK0Uu3lXQ6PS1ell3_wYIXBW-hJql2MvQks0lmZR7E9zXtLOtNCKSSfF-o4sfYlYBWgNBvd61N6FoJUragWpDwjK1Ep_tGyvHHc7YCgLEZpYaX7FXOu-WopFqx37dEB0p8jyceYuEbqqsUSu94ohmLjyFv_WG5_EUUuMWypfrM3SlPx2AXgGNwfI72L83jxCvyDyzV9oEn_3NbmuwdOV6OIdA812qLtI_O43zKPj85-TV7MeGc6fJxv2DfP374dvO5ufv66cvN9V1ju64rTYc4ge5HjWI9KhgGHPWgNUiCfpKqX9tBSTeR2GyEWmuhOqj1oFBonBR23QV7c_73kOL9kXIxe59tbQ0DxWM2Ug9rJXU_QEXlGbUp5pxoMofk95hORoBZMjA7s2RglgwMKFMzqNL7s0R1iAdPyWTrKVhyPpEtxkX_P_0PF-ySjg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2678426570</pqid></control><display><type>article</type><title>Deeper may not be better: relationship between catheter dysfunction and location of the catheter tip in right-sided tunnelled haemodialysis catheters</title><source>Access via ScienceDirect (Elsevier)</source><creator>Soh, N.Y.T. ; Tan, B.S. ; Chan, S.J.M. ; Patel, A. ; Gogna, A. ; Zhuang, K.D. ; Tashi, S. ; Venkatanarasimha, N. ; Tay, K.H. ; Chandramohan, S.</creator><creatorcontrib>Soh, N.Y.T. ; Tan, B.S. ; Chan, S.J.M. ; Patel, A. ; Gogna, A. ; Zhuang, K.D. ; Tashi, S. ; Venkatanarasimha, N. ; Tay, K.H. ; Chandramohan, S.</creatorcontrib><description>To examine the relationship between catheter tip location and catheter dysfunction in the context of tunnelled central venous catheters (CVCs) for haemodialysis. This was a retrospective study of 993 haemodialysis patients who underwent insertion of tunnelled CVCs of step-tip design via the right internal jugular vein (IJV). Based on intra-procedural radiographs, the catheter tip was characterised as being in the superior vena cava (SVC), cavo-atrial junction (CAJ), or deep right atrium (DRA). Patients were tracked for 90 days post-procedure for complications resulting in catheter replacement, and these were compared between cohorts. Statistical analysis was performed with Pearson's chi-square and Fisher's exact tests for categorical variables and two-sample t-test and one-way analysis of variance (ANOVA) for continuous variables. Ninety-five patients (9.6%) experienced catheter dysfunction necessitating replacement within 90 days of insertion. Tip location in SVC was associated with lower occurrence of catheter dysfunction (1.9%) as compared with the CAJ (8%) and DRA (11%; p=0.049). Catheter replacement due to other complications (catheter-associated bacteraemia, cuff dislodgement, exit-site infection, external catheter damage) showed no statistically significant relation to location of the CVC tip. When utilising tunnelled CVCs with a step-tip design inserted via the right IJV, location of the catheter tip in the SVC is associated with reduced occurrence of catheter dysfunction as compared to either the CAJ or DRA. •CVC tip in the SVC is associated with lower incidence of catheter dysfunction.•In the context of tunneled CVCs for haemodialysis•When utilising a step-tip catheter design inserted via the right IJV•Largest study to date examining this relationship</description><identifier>ISSN: 0009-9260</identifier><identifier>EISSN: 1365-229X</identifier><identifier>DOI: 10.1016/j.crad.2022.04.020</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><ispartof>Clinical radiology, 2022-09, Vol.77 (9), p.678-683</ispartof><rights>2022 The Royal College of Radiologists</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c333t-3aaf06596a1894077a9676602e05f2458c742dfe1bb14861430e1b74a16af4a33</citedby><cites>FETCH-LOGICAL-c333t-3aaf06596a1894077a9676602e05f2458c742dfe1bb14861430e1b74a16af4a33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.crad.2022.04.020$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Soh, N.Y.T.</creatorcontrib><creatorcontrib>Tan, B.S.</creatorcontrib><creatorcontrib>Chan, S.J.M.</creatorcontrib><creatorcontrib>Patel, A.</creatorcontrib><creatorcontrib>Gogna, A.</creatorcontrib><creatorcontrib>Zhuang, K.D.</creatorcontrib><creatorcontrib>Tashi, S.</creatorcontrib><creatorcontrib>Venkatanarasimha, N.</creatorcontrib><creatorcontrib>Tay, K.H.</creatorcontrib><creatorcontrib>Chandramohan, S.</creatorcontrib><title>Deeper may not be better: relationship between catheter dysfunction and location of the catheter tip in right-sided tunnelled haemodialysis catheters</title><title>Clinical radiology</title><description>To examine the relationship between catheter tip location and catheter dysfunction in the context of tunnelled central venous catheters (CVCs) for haemodialysis. This was a retrospective study of 993 haemodialysis patients who underwent insertion of tunnelled CVCs of step-tip design via the right internal jugular vein (IJV). Based on intra-procedural radiographs, the catheter tip was characterised as being in the superior vena cava (SVC), cavo-atrial junction (CAJ), or deep right atrium (DRA). Patients were tracked for 90 days post-procedure for complications resulting in catheter replacement, and these were compared between cohorts. Statistical analysis was performed with Pearson's chi-square and Fisher's exact tests for categorical variables and two-sample t-test and one-way analysis of variance (ANOVA) for continuous variables. Ninety-five patients (9.6%) experienced catheter dysfunction necessitating replacement within 90 days of insertion. Tip location in SVC was associated with lower occurrence of catheter dysfunction (1.9%) as compared with the CAJ (8%) and DRA (11%; p=0.049). Catheter replacement due to other complications (catheter-associated bacteraemia, cuff dislodgement, exit-site infection, external catheter damage) showed no statistically significant relation to location of the CVC tip. When utilising tunnelled CVCs with a step-tip design inserted via the right IJV, location of the catheter tip in the SVC is associated with reduced occurrence of catheter dysfunction as compared to either the CAJ or DRA. •CVC tip in the SVC is associated with lower incidence of catheter dysfunction.•In the context of tunneled CVCs for haemodialysis•When utilising a step-tip catheter design inserted via the right IJV•Largest study to date examining this relationship</description><issn>0009-9260</issn><issn>1365-229X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kc-KFDEQh4MoOK77AnvK0Uu3lXQ6PS1ell3_wYIXBW-hJql2MvQks0lmZR7E9zXtLOtNCKSSfF-o4sfYlYBWgNBvd61N6FoJUragWpDwjK1Ep_tGyvHHc7YCgLEZpYaX7FXOu-WopFqx37dEB0p8jyceYuEbqqsUSu94ohmLjyFv_WG5_EUUuMWypfrM3SlPx2AXgGNwfI72L83jxCvyDyzV9oEn_3NbmuwdOV6OIdA812qLtI_O43zKPj85-TV7MeGc6fJxv2DfP374dvO5ufv66cvN9V1ju64rTYc4ge5HjWI9KhgGHPWgNUiCfpKqX9tBSTeR2GyEWmuhOqj1oFBonBR23QV7c_73kOL9kXIxe59tbQ0DxWM2Ug9rJXU_QEXlGbUp5pxoMofk95hORoBZMjA7s2RglgwMKFMzqNL7s0R1iAdPyWTrKVhyPpEtxkX_P_0PF-ySjg</recordid><startdate>20220901</startdate><enddate>20220901</enddate><creator>Soh, N.Y.T.</creator><creator>Tan, B.S.</creator><creator>Chan, S.J.M.</creator><creator>Patel, A.</creator><creator>Gogna, A.</creator><creator>Zhuang, K.D.</creator><creator>Tashi, S.</creator><creator>Venkatanarasimha, N.</creator><creator>Tay, K.H.</creator><creator>Chandramohan, S.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20220901</creationdate><title>Deeper may not be better: relationship between catheter dysfunction and location of the catheter tip in right-sided tunnelled haemodialysis catheters</title><author>Soh, N.Y.T. ; Tan, B.S. ; Chan, S.J.M. ; Patel, A. ; Gogna, A. ; Zhuang, K.D. ; Tashi, S. ; Venkatanarasimha, N. ; Tay, K.H. ; Chandramohan, S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c333t-3aaf06596a1894077a9676602e05f2458c742dfe1bb14861430e1b74a16af4a33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Soh, N.Y.T.</creatorcontrib><creatorcontrib>Tan, B.S.</creatorcontrib><creatorcontrib>Chan, S.J.M.</creatorcontrib><creatorcontrib>Patel, A.</creatorcontrib><creatorcontrib>Gogna, A.</creatorcontrib><creatorcontrib>Zhuang, K.D.</creatorcontrib><creatorcontrib>Tashi, S.</creatorcontrib><creatorcontrib>Venkatanarasimha, N.</creatorcontrib><creatorcontrib>Tay, K.H.</creatorcontrib><creatorcontrib>Chandramohan, S.</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Soh, N.Y.T.</au><au>Tan, B.S.</au><au>Chan, S.J.M.</au><au>Patel, A.</au><au>Gogna, A.</au><au>Zhuang, K.D.</au><au>Tashi, S.</au><au>Venkatanarasimha, N.</au><au>Tay, K.H.</au><au>Chandramohan, S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Deeper may not be better: relationship between catheter dysfunction and location of the catheter tip in right-sided tunnelled haemodialysis catheters</atitle><jtitle>Clinical radiology</jtitle><date>2022-09-01</date><risdate>2022</risdate><volume>77</volume><issue>9</issue><spage>678</spage><epage>683</epage><pages>678-683</pages><issn>0009-9260</issn><eissn>1365-229X</eissn><abstract>To examine the relationship between catheter tip location and catheter dysfunction in the context of tunnelled central venous catheters (CVCs) for haemodialysis. This was a retrospective study of 993 haemodialysis patients who underwent insertion of tunnelled CVCs of step-tip design via the right internal jugular vein (IJV). Based on intra-procedural radiographs, the catheter tip was characterised as being in the superior vena cava (SVC), cavo-atrial junction (CAJ), or deep right atrium (DRA). Patients were tracked for 90 days post-procedure for complications resulting in catheter replacement, and these were compared between cohorts. Statistical analysis was performed with Pearson's chi-square and Fisher's exact tests for categorical variables and two-sample t-test and one-way analysis of variance (ANOVA) for continuous variables. Ninety-five patients (9.6%) experienced catheter dysfunction necessitating replacement within 90 days of insertion. Tip location in SVC was associated with lower occurrence of catheter dysfunction (1.9%) as compared with the CAJ (8%) and DRA (11%; p=0.049). Catheter replacement due to other complications (catheter-associated bacteraemia, cuff dislodgement, exit-site infection, external catheter damage) showed no statistically significant relation to location of the CVC tip. When utilising tunnelled CVCs with a step-tip design inserted via the right IJV, location of the catheter tip in the SVC is associated with reduced occurrence of catheter dysfunction as compared to either the CAJ or DRA. •CVC tip in the SVC is associated with lower incidence of catheter dysfunction.•In the context of tunneled CVCs for haemodialysis•When utilising a step-tip catheter design inserted via the right IJV•Largest study to date examining this relationship</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.crad.2022.04.020</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0009-9260
ispartof Clinical radiology, 2022-09, Vol.77 (9), p.678-683
issn 0009-9260
1365-229X
language eng
recordid cdi_proquest_miscellaneous_2678426570
source Access via ScienceDirect (Elsevier)
title Deeper may not be better: relationship between catheter dysfunction and location of the catheter tip in right-sided tunnelled haemodialysis catheters
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T23%3A44%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Deeper%20may%20not%20be%20better:%20relationship%20between%20catheter%20dysfunction%20and%20location%20of%20the%20catheter%20tip%20in%20right-sided%20tunnelled%20haemodialysis%20catheters&rft.jtitle=Clinical%20radiology&rft.au=Soh,%20N.Y.T.&rft.date=2022-09-01&rft.volume=77&rft.issue=9&rft.spage=678&rft.epage=683&rft.pages=678-683&rft.issn=0009-9260&rft.eissn=1365-229X&rft_id=info:doi/10.1016/j.crad.2022.04.020&rft_dat=%3Cproquest_cross%3E2678426570%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2678426570&rft_id=info:pmid/&rft_els_id=S000992602200229X&rfr_iscdi=true