Acoustic emission detection of damage in reinforced concrete conduit

Acoustic emission has been used to determine condition in reinforced concrete conduit. Acoustic data generated by PLB (pencil-lead break) were collected from both good PCCP (Prestressed Concrete Cylinder Pipe) and damaged PCCP as digital waveform files. These files were analyzed using the normalized...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of acoustic emission 2001-11, Vol.18-19, p.189-195
Hauptverfasser: Shen, H W, Iyer, S, Friesel, M A, Mostert, F, Finlayson, R D, Miller, R K, Carlos, M F, Vahaviolos, S J
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 195
container_issue
container_start_page 189
container_title Journal of acoustic emission
container_volume 18-19
creator Shen, H W
Iyer, S
Friesel, M A
Mostert, F
Finlayson, R D
Miller, R K
Carlos, M F
Vahaviolos, S J
description Acoustic emission has been used to determine condition in reinforced concrete conduit. Acoustic data generated by PLB (pencil-lead break) were collected from both good PCCP (Prestressed Concrete Cylinder Pipe) and damaged PCCP as digital waveform files. These files were analyzed using the normalized frequency energy method. The results indicate that the energy in specific frequency segments can indicate the condition of the conduit, and with an appropriate tuning process, may show the type of damage; e.g., broken wire or delamination. A partial power function and a graphic alarm have been implemented in a standard AE instrument. A portable handheld sensor-head support structure has been designed and built to maintain a constant source-sensor distance spanning the width of the desired inspection region for a standard 1.2-m diameter PCCP.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_26692382</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>26689833</sourcerecordid><originalsourceid>FETCH-LOGICAL-p622-2b8426d0ca3e64887cb57edc37d15f62db6df4c660d3ba9e9671a0314268eafd3</originalsourceid><addsrcrecordid>eNqNj71uwzAQgzW0QNK076Cpm4GzZJ_lMUh_gQBZsgfy3SlQ4VipZb9_HbQP0InfQBLknVpDY6EAqGGlHnL-AsC6MrBWL1tKc54iabnEnGMaNMskNN0oBc3-4s-i46BHiUNIIwlrSgONi-sGPMfpUd0H32d5-tONOr69Hncfxf7w_rnb7osrGlOYzlUGGchbwcq5hrq6ESbbcFkHNNwhh4oQgW3nW2mxKT3Ycgk58YHtRj3_1l7H9D1Lnk7LZJK-94MsJ04GsTXWmf8YXeustT_W81UN</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>26689833</pqid></control><display><type>article</type><title>Acoustic emission detection of damage in reinforced concrete conduit</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Shen, H W ; Iyer, S ; Friesel, M A ; Mostert, F ; Finlayson, R D ; Miller, R K ; Carlos, M F ; Vahaviolos, S J</creator><creatorcontrib>Shen, H W ; Iyer, S ; Friesel, M A ; Mostert, F ; Finlayson, R D ; Miller, R K ; Carlos, M F ; Vahaviolos, S J</creatorcontrib><description>Acoustic emission has been used to determine condition in reinforced concrete conduit. Acoustic data generated by PLB (pencil-lead break) were collected from both good PCCP (Prestressed Concrete Cylinder Pipe) and damaged PCCP as digital waveform files. These files were analyzed using the normalized frequency energy method. The results indicate that the energy in specific frequency segments can indicate the condition of the conduit, and with an appropriate tuning process, may show the type of damage; e.g., broken wire or delamination. A partial power function and a graphic alarm have been implemented in a standard AE instrument. A portable handheld sensor-head support structure has been designed and built to maintain a constant source-sensor distance spanning the width of the desired inspection region for a standard 1.2-m diameter PCCP.</description><identifier>ISSN: 0730-0050</identifier><language>eng</language><ispartof>Journal of acoustic emission, 2001-11, Vol.18-19, p.189-195</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781</link.rule.ids></links><search><creatorcontrib>Shen, H W</creatorcontrib><creatorcontrib>Iyer, S</creatorcontrib><creatorcontrib>Friesel, M A</creatorcontrib><creatorcontrib>Mostert, F</creatorcontrib><creatorcontrib>Finlayson, R D</creatorcontrib><creatorcontrib>Miller, R K</creatorcontrib><creatorcontrib>Carlos, M F</creatorcontrib><creatorcontrib>Vahaviolos, S J</creatorcontrib><title>Acoustic emission detection of damage in reinforced concrete conduit</title><title>Journal of acoustic emission</title><description>Acoustic emission has been used to determine condition in reinforced concrete conduit. Acoustic data generated by PLB (pencil-lead break) were collected from both good PCCP (Prestressed Concrete Cylinder Pipe) and damaged PCCP as digital waveform files. These files were analyzed using the normalized frequency energy method. The results indicate that the energy in specific frequency segments can indicate the condition of the conduit, and with an appropriate tuning process, may show the type of damage; e.g., broken wire or delamination. A partial power function and a graphic alarm have been implemented in a standard AE instrument. A portable handheld sensor-head support structure has been designed and built to maintain a constant source-sensor distance spanning the width of the desired inspection region for a standard 1.2-m diameter PCCP.</description><issn>0730-0050</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><recordid>eNqNj71uwzAQgzW0QNK076Cpm4GzZJ_lMUh_gQBZsgfy3SlQ4VipZb9_HbQP0InfQBLknVpDY6EAqGGlHnL-AsC6MrBWL1tKc54iabnEnGMaNMskNN0oBc3-4s-i46BHiUNIIwlrSgONi-sGPMfpUd0H32d5-tONOr69Hncfxf7w_rnb7osrGlOYzlUGGchbwcq5hrq6ESbbcFkHNNwhh4oQgW3nW2mxKT3Ycgk58YHtRj3_1l7H9D1Lnk7LZJK-94MsJ04GsTXWmf8YXeustT_W81UN</recordid><startdate>20011130</startdate><enddate>20011130</enddate><creator>Shen, H W</creator><creator>Iyer, S</creator><creator>Friesel, M A</creator><creator>Mostert, F</creator><creator>Finlayson, R D</creator><creator>Miller, R K</creator><creator>Carlos, M F</creator><creator>Vahaviolos, S J</creator><scope>7SR</scope><scope>8FD</scope><scope>JG9</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20011130</creationdate><title>Acoustic emission detection of damage in reinforced concrete conduit</title><author>Shen, H W ; Iyer, S ; Friesel, M A ; Mostert, F ; Finlayson, R D ; Miller, R K ; Carlos, M F ; Vahaviolos, S J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p622-2b8426d0ca3e64887cb57edc37d15f62db6df4c660d3ba9e9671a0314268eafd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shen, H W</creatorcontrib><creatorcontrib>Iyer, S</creatorcontrib><creatorcontrib>Friesel, M A</creatorcontrib><creatorcontrib>Mostert, F</creatorcontrib><creatorcontrib>Finlayson, R D</creatorcontrib><creatorcontrib>Miller, R K</creatorcontrib><creatorcontrib>Carlos, M F</creatorcontrib><creatorcontrib>Vahaviolos, S J</creatorcontrib><collection>Engineered Materials Abstracts</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Journal of acoustic emission</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shen, H W</au><au>Iyer, S</au><au>Friesel, M A</au><au>Mostert, F</au><au>Finlayson, R D</au><au>Miller, R K</au><au>Carlos, M F</au><au>Vahaviolos, S J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Acoustic emission detection of damage in reinforced concrete conduit</atitle><jtitle>Journal of acoustic emission</jtitle><date>2001-11-30</date><risdate>2001</risdate><volume>18-19</volume><spage>189</spage><epage>195</epage><pages>189-195</pages><issn>0730-0050</issn><abstract>Acoustic emission has been used to determine condition in reinforced concrete conduit. Acoustic data generated by PLB (pencil-lead break) were collected from both good PCCP (Prestressed Concrete Cylinder Pipe) and damaged PCCP as digital waveform files. These files were analyzed using the normalized frequency energy method. The results indicate that the energy in specific frequency segments can indicate the condition of the conduit, and with an appropriate tuning process, may show the type of damage; e.g., broken wire or delamination. A partial power function and a graphic alarm have been implemented in a standard AE instrument. A portable handheld sensor-head support structure has been designed and built to maintain a constant source-sensor distance spanning the width of the desired inspection region for a standard 1.2-m diameter PCCP.</abstract><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0730-0050
ispartof Journal of acoustic emission, 2001-11, Vol.18-19, p.189-195
issn 0730-0050
language eng
recordid cdi_proquest_miscellaneous_26692382
source EZB-FREE-00999 freely available EZB journals
title Acoustic emission detection of damage in reinforced concrete conduit
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T07%3A34%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Acoustic%20emission%20detection%20of%20damage%20in%20reinforced%20concrete%20conduit&rft.jtitle=Journal%20of%20acoustic%20emission&rft.au=Shen,%20H%20W&rft.date=2001-11-30&rft.volume=18-19&rft.spage=189&rft.epage=195&rft.pages=189-195&rft.issn=0730-0050&rft_id=info:doi/&rft_dat=%3Cproquest%3E26689833%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=26689833&rft_id=info:pmid/&rfr_iscdi=true