Oxygenation Factors Associated with Retinopathy of Prematurity in Infants of Extremely Low Birth Weight

To study characteristics of oxygenation during the first 2 postnatal months and correlation with the occurrence and severity of retinopathy of prematurity (ROP) among infants of extremely low birth weight. This retrospective study analyzed the incidence and severity of hyperoxemia and hypoxemia whil...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of pediatrics 2022-08, Vol.247, p.46-52.e4
Hauptverfasser: Srivatsa, Bharath, Hagan, Joseph L., Clark, Reese H., Kupke, Kenneth G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 52.e4
container_issue
container_start_page 46
container_title The Journal of pediatrics
container_volume 247
creator Srivatsa, Bharath
Hagan, Joseph L.
Clark, Reese H.
Kupke, Kenneth G.
description To study characteristics of oxygenation during the first 2 postnatal months and correlation with the occurrence and severity of retinopathy of prematurity (ROP) among infants of extremely low birth weight. This retrospective study analyzed the incidence and severity of hyperoxemia and hypoxemia while on respiratory support with or without supplemental oxygen among infants of extremely low birth weight (birth weight
doi_str_mv 10.1016/j.jpeds.2022.03.057
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2651686798</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022347622003183</els_id><sourcerecordid>2651686798</sourcerecordid><originalsourceid>FETCH-LOGICAL-c289t-bcfff805efd62f8d28cbf58b9e9fd61bd287c8db23d7dcea58d5bf96aca8be303</originalsourceid><addsrcrecordid>eNp9kEtLKzEUx4Nc0fr4BMIly7uZMZN0MpnFXaj4goIiisuQSU7alHZSk1Sdb29q1aWrA__HOZwfQicVKStS8dN5OV-BiSUllJaElaRudtCoIm1TcMHYHzQi2SnYuOH76CDGOSGkHROyh_ZZPaYNF-0ITe_ehyn0Kjnf4yulkw8Rn8XotVMJDH5zaYYfILner1SaDdhbfB9gqdI6uDRg1-Pb3qo-xY1z-Z6yB4sBT_wbPnchl5_BTWfpCO1atYhw_DUP0dPV5ePFTTG5u769OJsUmoo2FZ221gpSgzWcWmGo0J2tRddCm5Wqy0KjhekoM43RoGph6s62XGklOmCEHaJ_272r4F_WEJNcuqhhsVA9-HWUlNcVF7xpRY6ybVQHH2MAK1fBLVUYZEXkhrCcy0_CckNYEiYz4dz6-3Vg3S3B_HS-kebA_20A8puvDoKM2kGvwbgAOknj3a8HPgA-1pEM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2651686798</pqid></control><display><type>article</type><title>Oxygenation Factors Associated with Retinopathy of Prematurity in Infants of Extremely Low Birth Weight</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Srivatsa, Bharath ; Hagan, Joseph L. ; Clark, Reese H. ; Kupke, Kenneth G.</creator><creatorcontrib>Srivatsa, Bharath ; Hagan, Joseph L. ; Clark, Reese H. ; Kupke, Kenneth G.</creatorcontrib><description>To study characteristics of oxygenation during the first 2 postnatal months and correlation with the occurrence and severity of retinopathy of prematurity (ROP) among infants of extremely low birth weight. This retrospective study analyzed the incidence and severity of hyperoxemia and hypoxemia while on respiratory support with or without supplemental oxygen among infants of extremely low birth weight (birth weight &lt;1000 g) admitted to the neonatal intensive care unit during 2016-2020. The findings were correlated with the occurrence and severity of ROP after adjusting for baseline covariates. After adjusting for differences in baseline demographic and clinical features, the group with severe ROP was exposed to greater fraction of inspired oxygen (FiO2) (P = .001) and experienced more frequent FiO2 titration adjustments (P = .001) compared with the group without ROP. Ambient air hyperoxemia occurred more frequently in the group without ROP (P = .003), and iatrogenic hyperoxemia occurred more frequently in the group with severe ROP (P = .046). There were no differences in the severity of ambient and iatrogenic hyperoxemia in the study population. The group with severe ROP demonstrated more hypoxemic episodes (P = .01) and longer time spent in the severe hypoxemic range (P = .005) compared with the group without ROP. Severe ROP is associated with greater FiO2 exposure, increased iatrogenic hyperoxemia, decreased ambient air hyperoxemia, and increased hypoxemia in infants of extremely low birth weight despite a greater frequency of FiO2 titration. This study illustrates the need for automated closed loop FiO2 delivery systems to further optimize oxygen saturation targeting in this high-risk population.</description><identifier>ISSN: 0022-3476</identifier><identifier>EISSN: 1097-6833</identifier><identifier>DOI: 10.1016/j.jpeds.2022.03.057</identifier><identifier>PMID: 35427689</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>ambient air hyperoxemia ; continuous FiO2 monitoring ; iatrogenic hyperoxemia ; oxygen lability ; oxygen saturation targeting ; oxygen titration ; retinopathy of prematurity</subject><ispartof>The Journal of pediatrics, 2022-08, Vol.247, p.46-52.e4</ispartof><rights>2022 Elsevier Inc.</rights><rights>Copyright © 2022 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c289t-bcfff805efd62f8d28cbf58b9e9fd61bd287c8db23d7dcea58d5bf96aca8be303</citedby><cites>FETCH-LOGICAL-c289t-bcfff805efd62f8d28cbf58b9e9fd61bd287c8db23d7dcea58d5bf96aca8be303</cites><orcidid>0000-0002-5822-2963</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0022347622003183$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65534</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35427689$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Srivatsa, Bharath</creatorcontrib><creatorcontrib>Hagan, Joseph L.</creatorcontrib><creatorcontrib>Clark, Reese H.</creatorcontrib><creatorcontrib>Kupke, Kenneth G.</creatorcontrib><title>Oxygenation Factors Associated with Retinopathy of Prematurity in Infants of Extremely Low Birth Weight</title><title>The Journal of pediatrics</title><addtitle>J Pediatr</addtitle><description>To study characteristics of oxygenation during the first 2 postnatal months and correlation with the occurrence and severity of retinopathy of prematurity (ROP) among infants of extremely low birth weight. This retrospective study analyzed the incidence and severity of hyperoxemia and hypoxemia while on respiratory support with or without supplemental oxygen among infants of extremely low birth weight (birth weight &lt;1000 g) admitted to the neonatal intensive care unit during 2016-2020. The findings were correlated with the occurrence and severity of ROP after adjusting for baseline covariates. After adjusting for differences in baseline demographic and clinical features, the group with severe ROP was exposed to greater fraction of inspired oxygen (FiO2) (P = .001) and experienced more frequent FiO2 titration adjustments (P = .001) compared with the group without ROP. Ambient air hyperoxemia occurred more frequently in the group without ROP (P = .003), and iatrogenic hyperoxemia occurred more frequently in the group with severe ROP (P = .046). There were no differences in the severity of ambient and iatrogenic hyperoxemia in the study population. The group with severe ROP demonstrated more hypoxemic episodes (P = .01) and longer time spent in the severe hypoxemic range (P = .005) compared with the group without ROP. Severe ROP is associated with greater FiO2 exposure, increased iatrogenic hyperoxemia, decreased ambient air hyperoxemia, and increased hypoxemia in infants of extremely low birth weight despite a greater frequency of FiO2 titration. This study illustrates the need for automated closed loop FiO2 delivery systems to further optimize oxygen saturation targeting in this high-risk population.</description><subject>ambient air hyperoxemia</subject><subject>continuous FiO2 monitoring</subject><subject>iatrogenic hyperoxemia</subject><subject>oxygen lability</subject><subject>oxygen saturation targeting</subject><subject>oxygen titration</subject><subject>retinopathy of prematurity</subject><issn>0022-3476</issn><issn>1097-6833</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kEtLKzEUx4Nc0fr4BMIly7uZMZN0MpnFXaj4goIiisuQSU7alHZSk1Sdb29q1aWrA__HOZwfQicVKStS8dN5OV-BiSUllJaElaRudtCoIm1TcMHYHzQi2SnYuOH76CDGOSGkHROyh_ZZPaYNF-0ITe_ehyn0Kjnf4yulkw8Rn8XotVMJDH5zaYYfILner1SaDdhbfB9gqdI6uDRg1-Pb3qo-xY1z-Z6yB4sBT_wbPnchl5_BTWfpCO1atYhw_DUP0dPV5ePFTTG5u769OJsUmoo2FZ221gpSgzWcWmGo0J2tRddCm5Wqy0KjhekoM43RoGph6s62XGklOmCEHaJ_272r4F_WEJNcuqhhsVA9-HWUlNcVF7xpRY6ybVQHH2MAK1fBLVUYZEXkhrCcy0_CckNYEiYz4dz6-3Vg3S3B_HS-kebA_20A8puvDoKM2kGvwbgAOknj3a8HPgA-1pEM</recordid><startdate>20220801</startdate><enddate>20220801</enddate><creator>Srivatsa, Bharath</creator><creator>Hagan, Joseph L.</creator><creator>Clark, Reese H.</creator><creator>Kupke, Kenneth G.</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-5822-2963</orcidid></search><sort><creationdate>20220801</creationdate><title>Oxygenation Factors Associated with Retinopathy of Prematurity in Infants of Extremely Low Birth Weight</title><author>Srivatsa, Bharath ; Hagan, Joseph L. ; Clark, Reese H. ; Kupke, Kenneth G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c289t-bcfff805efd62f8d28cbf58b9e9fd61bd287c8db23d7dcea58d5bf96aca8be303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>ambient air hyperoxemia</topic><topic>continuous FiO2 monitoring</topic><topic>iatrogenic hyperoxemia</topic><topic>oxygen lability</topic><topic>oxygen saturation targeting</topic><topic>oxygen titration</topic><topic>retinopathy of prematurity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Srivatsa, Bharath</creatorcontrib><creatorcontrib>Hagan, Joseph L.</creatorcontrib><creatorcontrib>Clark, Reese H.</creatorcontrib><creatorcontrib>Kupke, Kenneth G.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of pediatrics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Srivatsa, Bharath</au><au>Hagan, Joseph L.</au><au>Clark, Reese H.</au><au>Kupke, Kenneth G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Oxygenation Factors Associated with Retinopathy of Prematurity in Infants of Extremely Low Birth Weight</atitle><jtitle>The Journal of pediatrics</jtitle><addtitle>J Pediatr</addtitle><date>2022-08-01</date><risdate>2022</risdate><volume>247</volume><spage>46</spage><epage>52.e4</epage><pages>46-52.e4</pages><issn>0022-3476</issn><eissn>1097-6833</eissn><abstract>To study characteristics of oxygenation during the first 2 postnatal months and correlation with the occurrence and severity of retinopathy of prematurity (ROP) among infants of extremely low birth weight. This retrospective study analyzed the incidence and severity of hyperoxemia and hypoxemia while on respiratory support with or without supplemental oxygen among infants of extremely low birth weight (birth weight &lt;1000 g) admitted to the neonatal intensive care unit during 2016-2020. The findings were correlated with the occurrence and severity of ROP after adjusting for baseline covariates. After adjusting for differences in baseline demographic and clinical features, the group with severe ROP was exposed to greater fraction of inspired oxygen (FiO2) (P = .001) and experienced more frequent FiO2 titration adjustments (P = .001) compared with the group without ROP. Ambient air hyperoxemia occurred more frequently in the group without ROP (P = .003), and iatrogenic hyperoxemia occurred more frequently in the group with severe ROP (P = .046). There were no differences in the severity of ambient and iatrogenic hyperoxemia in the study population. The group with severe ROP demonstrated more hypoxemic episodes (P = .01) and longer time spent in the severe hypoxemic range (P = .005) compared with the group without ROP. Severe ROP is associated with greater FiO2 exposure, increased iatrogenic hyperoxemia, decreased ambient air hyperoxemia, and increased hypoxemia in infants of extremely low birth weight despite a greater frequency of FiO2 titration. This study illustrates the need for automated closed loop FiO2 delivery systems to further optimize oxygen saturation targeting in this high-risk population.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>35427689</pmid><doi>10.1016/j.jpeds.2022.03.057</doi><orcidid>https://orcid.org/0000-0002-5822-2963</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0022-3476
ispartof The Journal of pediatrics, 2022-08, Vol.247, p.46-52.e4
issn 0022-3476
1097-6833
language eng
recordid cdi_proquest_miscellaneous_2651686798
source Elsevier ScienceDirect Journals Complete
subjects ambient air hyperoxemia
continuous FiO2 monitoring
iatrogenic hyperoxemia
oxygen lability
oxygen saturation targeting
oxygen titration
retinopathy of prematurity
title Oxygenation Factors Associated with Retinopathy of Prematurity in Infants of Extremely Low Birth Weight
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-14T08%3A07%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Oxygenation%20Factors%20Associated%20with%20Retinopathy%20of%20Prematurity%20in%20Infants%20of%20Extremely%20Low%20Birth%20Weight&rft.jtitle=The%20Journal%20of%20pediatrics&rft.au=Srivatsa,%20Bharath&rft.date=2022-08-01&rft.volume=247&rft.spage=46&rft.epage=52.e4&rft.pages=46-52.e4&rft.issn=0022-3476&rft.eissn=1097-6833&rft_id=info:doi/10.1016/j.jpeds.2022.03.057&rft_dat=%3Cproquest_cross%3E2651686798%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2651686798&rft_id=info:pmid/35427689&rft_els_id=S0022347622003183&rfr_iscdi=true