Colorectal Sessile Serrated Lesion Detection Using Linked Color Imaging: A Multicenter, Parallel Randomized Controlled Trial
Linked color imaging (LCI) is a novel technology that improves the color differences between colorectal lesions and the surrounding mucosa. The present study aims to compare the detection of colorectal sessile serrated lesions (SSL) using LCI with white light imaging (WLI). A large-scale, multicente...
Gespeichert in:
Veröffentlicht in: | Clinical gastroenterology and hepatology 2023-02, Vol.21 (2), p.328-336.e2 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Linked color imaging (LCI) is a novel technology that improves the color differences between colorectal lesions and the surrounding mucosa. The present study aims to compare the detection of colorectal sessile serrated lesions (SSL) using LCI with white light imaging (WLI).
A large-scale, multicenter, parallel prospective randomized controlled trial was conducted in 4 hospitals in China. The participants were randomly assigned to the LCI group and WLI group. The primary endpoint was the SSL detection rate (SDR).
A total of 884 patients were involved in the intention-to-treat analysis, with 441 patients in the LCI group and 443 patients in the WLI group. The total polyp detection rate, adenoma detection rate, and SDR were 51.8%, 35.7%, and 8.6%, respectively. The SDR was significantly higher in the LCI group than in the WLI group (11.3% vs 5.9%, P = .004). Furthermore, LCI significantly increased the number of polyps and adenomas detected per patient, when compared with WLI (P < .05). In addition, there was higher detection rate of diminutive and flat lesions in the LCI group (P < .05). Multivariate analysis revealed that LCI is an independent factor associated with SDR (hazard ratio, 1.990; 95% confidence interval, 1.203–3.293; P = .007), along with withdrawal time (hazard ratio, 1.157; 95% confidence interval, 1.060–1.263; P = .001) and operator experience (hazard ratio, 1.850; 95% confidence interval, 1.045–3.273; P = .035).
LCI is significantly superior to WLI for SSL detection, and may improve polyp and adenoma detection. LCI can be recommended as an appropriate method for routine inspection during colonoscopy (http://www.chictr.org.cn number, ChiCTR2000035705).
[Display omitted] |
---|---|
ISSN: | 1542-3565 1542-7714 |
DOI: | 10.1016/j.cgh.2022.03.033 |