Calibration of a polarization image sensor and investigation of influencing factors

Polarization measurements conducted with a polarization camera using the Sony IMX 250 MZR polarization image sensor are assessed with the super-pixel calibration technique and a simple test setup. We define an error that quantifies the quality of the polarization measurements. Multiple factors influ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied optics (2004) 2022-02, Vol.61 (6), p.C37-C45
Hauptverfasser: Lane, Connor, Rode, David, Rösgen, Thomas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page C45
container_issue 6
container_start_page C37
container_title Applied optics (2004)
container_volume 61
creator Lane, Connor
Rode, David
Rösgen, Thomas
description Polarization measurements conducted with a polarization camera using the Sony IMX 250 MZR polarization image sensor are assessed with the super-pixel calibration technique and a simple test setup. We define an error that quantifies the quality of the polarization measurements. Multiple factors influencing the measurement quality of the polarization camera are investigated and discussed. We demonstrate that polarization measurements are generally consistent throughout the sensor if not corrupted by large chief ray angles or large angles of incidence. The central 600×400 were analyzed, and it is shown that sufficiently large -numbers no longer influence measurement quality. We also argue that lens design and focal length have little influence on these central pixels. The findings of this study provide useful guidance for researchers using such a polarization image sensor.
doi_str_mv 10.1364/ao.437391
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2632803445</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2632803445</sourcerecordid><originalsourceid>FETCH-LOGICAL-c379t-86466b96fd78e60e2444bf14c4475ba6676319888f38d0aaac9e0a58e99699be3</originalsourceid><addsrcrecordid>eNpdkE1LAzEQhoMotlYP_gFZ8KKHrcnmY5OjFL-g0IMK3pbZ3aSkbJOadAX99aZs7cHTDMMzLy8PQpcETwkV7A78lNGSKnKExgXhPKdE8GM0TqvKSSE_RugsxhXGlDNVnqIR5QXGSokxep1BZ-sAW-td5k0G2cZ3EOzPcLFrWOosahd9yMC1mXVfOm7t8vBgnel67RrrlpmBZutDPEcnBrqoL_Zzgt4fH95mz_l88fQyu5_nDS3VNpeCCVErYdpSaoF1wRirDWENYyWvQYhSUKKklIbKFgNAozQGLnUqrlSt6QTdDLmb4D_7VKta29jorgOnfR-rQtBCYsoYT-j1P3Tl--BSux1VCkEYV4m6Hagm-BiDNtUmJAPhuyK42pmu7hfVYDqxV_vEvl7r9kD-qaW_3Bx4CQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2637661459</pqid></control><display><type>article</type><title>Calibration of a polarization image sensor and investigation of influencing factors</title><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>Lane, Connor ; Rode, David ; Rösgen, Thomas</creator><creatorcontrib>Lane, Connor ; Rode, David ; Rösgen, Thomas</creatorcontrib><description>Polarization measurements conducted with a polarization camera using the Sony IMX 250 MZR polarization image sensor are assessed with the super-pixel calibration technique and a simple test setup. We define an error that quantifies the quality of the polarization measurements. Multiple factors influencing the measurement quality of the polarization camera are investigated and discussed. We demonstrate that polarization measurements are generally consistent throughout the sensor if not corrupted by large chief ray angles or large angles of incidence. The central 600×400 were analyzed, and it is shown that sufficiently large -numbers no longer influence measurement quality. We also argue that lens design and focal length have little influence on these central pixels. The findings of this study provide useful guidance for researchers using such a polarization image sensor.</description><identifier>ISSN: 1559-128X</identifier><identifier>EISSN: 2155-3165</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/ao.437391</identifier><identifier>PMID: 35200996</identifier><language>eng</language><publisher>United States: Optical Society of America</publisher><subject>Calibration ; Cameras ; Incidence angle ; Lens design ; Pixels ; Polarization ; Sensors</subject><ispartof>Applied optics (2004), 2022-02, Vol.61 (6), p.C37-C45</ispartof><rights>Copyright Optical Society of America Feb 20, 2022</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c379t-86466b96fd78e60e2444bf14c4475ba6676319888f38d0aaac9e0a58e99699be3</citedby><cites>FETCH-LOGICAL-c379t-86466b96fd78e60e2444bf14c4475ba6676319888f38d0aaac9e0a58e99699be3</cites><orcidid>0000-0001-9619-8821 ; 0000-0002-5527-4768</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,3262,27933,27934</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35200996$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lane, Connor</creatorcontrib><creatorcontrib>Rode, David</creatorcontrib><creatorcontrib>Rösgen, Thomas</creatorcontrib><title>Calibration of a polarization image sensor and investigation of influencing factors</title><title>Applied optics (2004)</title><addtitle>Appl Opt</addtitle><description>Polarization measurements conducted with a polarization camera using the Sony IMX 250 MZR polarization image sensor are assessed with the super-pixel calibration technique and a simple test setup. We define an error that quantifies the quality of the polarization measurements. Multiple factors influencing the measurement quality of the polarization camera are investigated and discussed. We demonstrate that polarization measurements are generally consistent throughout the sensor if not corrupted by large chief ray angles or large angles of incidence. The central 600×400 were analyzed, and it is shown that sufficiently large -numbers no longer influence measurement quality. We also argue that lens design and focal length have little influence on these central pixels. The findings of this study provide useful guidance for researchers using such a polarization image sensor.</description><subject>Calibration</subject><subject>Cameras</subject><subject>Incidence angle</subject><subject>Lens design</subject><subject>Pixels</subject><subject>Polarization</subject><subject>Sensors</subject><issn>1559-128X</issn><issn>2155-3165</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNpdkE1LAzEQhoMotlYP_gFZ8KKHrcnmY5OjFL-g0IMK3pbZ3aSkbJOadAX99aZs7cHTDMMzLy8PQpcETwkV7A78lNGSKnKExgXhPKdE8GM0TqvKSSE_RugsxhXGlDNVnqIR5QXGSokxep1BZ-sAW-td5k0G2cZ3EOzPcLFrWOosahd9yMC1mXVfOm7t8vBgnel67RrrlpmBZutDPEcnBrqoL_Zzgt4fH95mz_l88fQyu5_nDS3VNpeCCVErYdpSaoF1wRirDWENYyWvQYhSUKKklIbKFgNAozQGLnUqrlSt6QTdDLmb4D_7VKta29jorgOnfR-rQtBCYsoYT-j1P3Tl--BSux1VCkEYV4m6Hagm-BiDNtUmJAPhuyK42pmu7hfVYDqxV_vEvl7r9kD-qaW_3Bx4CQ</recordid><startdate>20220220</startdate><enddate>20220220</enddate><creator>Lane, Connor</creator><creator>Rode, David</creator><creator>Rösgen, Thomas</creator><general>Optical Society of America</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-9619-8821</orcidid><orcidid>https://orcid.org/0000-0002-5527-4768</orcidid></search><sort><creationdate>20220220</creationdate><title>Calibration of a polarization image sensor and investigation of influencing factors</title><author>Lane, Connor ; Rode, David ; Rösgen, Thomas</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c379t-86466b96fd78e60e2444bf14c4475ba6676319888f38d0aaac9e0a58e99699be3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Calibration</topic><topic>Cameras</topic><topic>Incidence angle</topic><topic>Lens design</topic><topic>Pixels</topic><topic>Polarization</topic><topic>Sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lane, Connor</creatorcontrib><creatorcontrib>Rode, David</creatorcontrib><creatorcontrib>Rösgen, Thomas</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Applied optics (2004)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lane, Connor</au><au>Rode, David</au><au>Rösgen, Thomas</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calibration of a polarization image sensor and investigation of influencing factors</atitle><jtitle>Applied optics (2004)</jtitle><addtitle>Appl Opt</addtitle><date>2022-02-20</date><risdate>2022</risdate><volume>61</volume><issue>6</issue><spage>C37</spage><epage>C45</epage><pages>C37-C45</pages><issn>1559-128X</issn><eissn>2155-3165</eissn><eissn>1539-4522</eissn><abstract>Polarization measurements conducted with a polarization camera using the Sony IMX 250 MZR polarization image sensor are assessed with the super-pixel calibration technique and a simple test setup. We define an error that quantifies the quality of the polarization measurements. Multiple factors influencing the measurement quality of the polarization camera are investigated and discussed. We demonstrate that polarization measurements are generally consistent throughout the sensor if not corrupted by large chief ray angles or large angles of incidence. The central 600×400 were analyzed, and it is shown that sufficiently large -numbers no longer influence measurement quality. We also argue that lens design and focal length have little influence on these central pixels. The findings of this study provide useful guidance for researchers using such a polarization image sensor.</abstract><cop>United States</cop><pub>Optical Society of America</pub><pmid>35200996</pmid><doi>10.1364/ao.437391</doi><orcidid>https://orcid.org/0000-0001-9619-8821</orcidid><orcidid>https://orcid.org/0000-0002-5527-4768</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1559-128X
ispartof Applied optics (2004), 2022-02, Vol.61 (6), p.C37-C45
issn 1559-128X
2155-3165
1539-4522
language eng
recordid cdi_proquest_miscellaneous_2632803445
source Alma/SFX Local Collection; Optica Publishing Group Journals
subjects Calibration
Cameras
Incidence angle
Lens design
Pixels
Polarization
Sensors
title Calibration of a polarization image sensor and investigation of influencing factors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-03T11%3A54%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calibration%20of%20a%20polarization%20image%20sensor%20and%20investigation%20of%20influencing%20factors&rft.jtitle=Applied%20optics%20(2004)&rft.au=Lane,%20Connor&rft.date=2022-02-20&rft.volume=61&rft.issue=6&rft.spage=C37&rft.epage=C45&rft.pages=C37-C45&rft.issn=1559-128X&rft.eissn=2155-3165&rft_id=info:doi/10.1364/ao.437391&rft_dat=%3Cproquest_cross%3E2632803445%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2637661459&rft_id=info:pmid/35200996&rfr_iscdi=true