Multisensor perfusion assessment cohort study: Preliminary evidence toward a standardized assessment of indocyanine green fluorescence in colorectal surgery

Traditional methods of assessing colonic perfusion are based on the surgeon’s visual inspection of tissue. Fluorescence angiography provides qualitative information, but there remains disagreement on how the observed signal should be interpreted. It is unclear whether fluorescence correlates with ph...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgery 2022-07, Vol.172 (1), p.69-73
Hauptverfasser: Soares, Antonio S., Bano, Sophia, Clancy, Neil T., Stoyanov, Danail, Lovat, Laurence B., Chand, Manish
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 73
container_issue 1
container_start_page 69
container_title Surgery
container_volume 172
creator Soares, Antonio S.
Bano, Sophia
Clancy, Neil T.
Stoyanov, Danail
Lovat, Laurence B.
Chand, Manish
description Traditional methods of assessing colonic perfusion are based on the surgeon’s visual inspection of tissue. Fluorescence angiography provides qualitative information, but there remains disagreement on how the observed signal should be interpreted. It is unclear whether fluorescence correlates with physiological properties of the tissue, such as tissue oxygen saturation. The aim of this study was to correlate fluorescence intensity and colonic tissue oxygen saturation. Prospective cohort study performed in a single academic tertiary referral center. Patients undergoing colorectal surgery who required an anastomosis underwent dual-modality perfusion assessment of a segment of bowel before transection and creation of the anastomosis, using near-infrared and multispectral imaging. Perfusion was assessed using maximal fluorescence intensity measurement during fluorescence angiography, and its correlation with tissue oxygen saturation was calculated. In total, 18 patients were included. Maximal fluorescence intensity occurred at a mean of 101 seconds after indocyanine green injection. The correlation coefficient was 0.73 (95% confidence interval of 0.65–0.79) with P < .0001, showing a statistically significant strong positive correlation between normalized fluorescence intensity and tissue oxygen saturation. The use of time averaging improved the correlation coefficient to 0.78. Fluorescence intensity is a potential surrogate for tissue oxygenation. This is expected to lead to improved decision making when transecting the bowel and, consequently, a reduction in anastomotic leak rates. A larger, phase II study is needed to confirm this result and form the basis of computational algorithms to infer biological or physiological information from the fluorescence imaging data.
doi_str_mv 10.1016/j.surg.2021.12.021
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2629379447</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039606021012447</els_id><sourcerecordid>2629379447</sourcerecordid><originalsourceid>FETCH-LOGICAL-c400t-784febbaea2e40fa89a77c0453bfd8f0d3d95abb4271ed348cdfa7b2fa26da083</originalsourceid><addsrcrecordid>eNp9UctuFDEQtBCIbAI_wAH5yGUGv3YeiAuKgCAlIodwtjx2O3g1Yy_umUTLt-Rj8bABceJU3VJ1dXcVIa84qznjzdtdjUu-rQUTvOaiLvCEbPhWiqqVDX9KNozJvmpYw07IKeKOMdYr3j0nJ3LLm67jakMerpZxDggRU6Z7yH7BkCI1iIA4QZypTd9TninOizu8o9cZxjCFaPKBwl1wEC3QOd2b7KgpJBNdKcNPcP9qJE9DdMkeTAwR6G0GiNSPS8qA9rdEiGXRWHo7m5Guf0E-vCDPvBkRXj7iGfn26ePN-UV1-fXzl_MPl5VVjM1V2ykPw2DACFDMm643bWuZ2srBu84zJ12_NcOgRMvBSdVZ5007CG9E4wzr5Bl5c9Td5_RjAZz1FMpd42gipAW1aEQv216ptlDFkWpzQszg9T6HqbihOdNrKnqn1-v1mormQhcoQ68f9ZdhAvd35E8MhfD-SIDy5V2ArNGG1RcXVke0S-F_-r8A7qKlEw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2629379447</pqid></control><display><type>article</type><title>Multisensor perfusion assessment cohort study: Preliminary evidence toward a standardized assessment of indocyanine green fluorescence in colorectal surgery</title><source>Access via ScienceDirect (Elsevier)</source><creator>Soares, Antonio S. ; Bano, Sophia ; Clancy, Neil T. ; Stoyanov, Danail ; Lovat, Laurence B. ; Chand, Manish</creator><creatorcontrib>Soares, Antonio S. ; Bano, Sophia ; Clancy, Neil T. ; Stoyanov, Danail ; Lovat, Laurence B. ; Chand, Manish</creatorcontrib><description>Traditional methods of assessing colonic perfusion are based on the surgeon’s visual inspection of tissue. Fluorescence angiography provides qualitative information, but there remains disagreement on how the observed signal should be interpreted. It is unclear whether fluorescence correlates with physiological properties of the tissue, such as tissue oxygen saturation. The aim of this study was to correlate fluorescence intensity and colonic tissue oxygen saturation. Prospective cohort study performed in a single academic tertiary referral center. Patients undergoing colorectal surgery who required an anastomosis underwent dual-modality perfusion assessment of a segment of bowel before transection and creation of the anastomosis, using near-infrared and multispectral imaging. Perfusion was assessed using maximal fluorescence intensity measurement during fluorescence angiography, and its correlation with tissue oxygen saturation was calculated. In total, 18 patients were included. Maximal fluorescence intensity occurred at a mean of 101 seconds after indocyanine green injection. The correlation coefficient was 0.73 (95% confidence interval of 0.65–0.79) with P &lt; .0001, showing a statistically significant strong positive correlation between normalized fluorescence intensity and tissue oxygen saturation. The use of time averaging improved the correlation coefficient to 0.78. Fluorescence intensity is a potential surrogate for tissue oxygenation. This is expected to lead to improved decision making when transecting the bowel and, consequently, a reduction in anastomotic leak rates. A larger, phase II study is needed to confirm this result and form the basis of computational algorithms to infer biological or physiological information from the fluorescence imaging data.</description><identifier>ISSN: 0039-6060</identifier><identifier>EISSN: 1532-7361</identifier><identifier>DOI: 10.1016/j.surg.2021.12.021</identifier><identifier>PMID: 35168814</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><ispartof>Surgery, 2022-07, Vol.172 (1), p.69-73</ispartof><rights>2022</rights><rights>Copyright © 2022. Published by Elsevier Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c400t-784febbaea2e40fa89a77c0453bfd8f0d3d95abb4271ed348cdfa7b2fa26da083</citedby><cites>FETCH-LOGICAL-c400t-784febbaea2e40fa89a77c0453bfd8f0d3d95abb4271ed348cdfa7b2fa26da083</cites><orcidid>0000-0001-7773-2427 ; 0000-0002-0980-3227</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.surg.2021.12.021$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35168814$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Soares, Antonio S.</creatorcontrib><creatorcontrib>Bano, Sophia</creatorcontrib><creatorcontrib>Clancy, Neil T.</creatorcontrib><creatorcontrib>Stoyanov, Danail</creatorcontrib><creatorcontrib>Lovat, Laurence B.</creatorcontrib><creatorcontrib>Chand, Manish</creatorcontrib><title>Multisensor perfusion assessment cohort study: Preliminary evidence toward a standardized assessment of indocyanine green fluorescence in colorectal surgery</title><title>Surgery</title><addtitle>Surgery</addtitle><description>Traditional methods of assessing colonic perfusion are based on the surgeon’s visual inspection of tissue. Fluorescence angiography provides qualitative information, but there remains disagreement on how the observed signal should be interpreted. It is unclear whether fluorescence correlates with physiological properties of the tissue, such as tissue oxygen saturation. The aim of this study was to correlate fluorescence intensity and colonic tissue oxygen saturation. Prospective cohort study performed in a single academic tertiary referral center. Patients undergoing colorectal surgery who required an anastomosis underwent dual-modality perfusion assessment of a segment of bowel before transection and creation of the anastomosis, using near-infrared and multispectral imaging. Perfusion was assessed using maximal fluorescence intensity measurement during fluorescence angiography, and its correlation with tissue oxygen saturation was calculated. In total, 18 patients were included. Maximal fluorescence intensity occurred at a mean of 101 seconds after indocyanine green injection. The correlation coefficient was 0.73 (95% confidence interval of 0.65–0.79) with P &lt; .0001, showing a statistically significant strong positive correlation between normalized fluorescence intensity and tissue oxygen saturation. The use of time averaging improved the correlation coefficient to 0.78. Fluorescence intensity is a potential surrogate for tissue oxygenation. This is expected to lead to improved decision making when transecting the bowel and, consequently, a reduction in anastomotic leak rates. A larger, phase II study is needed to confirm this result and form the basis of computational algorithms to infer biological or physiological information from the fluorescence imaging data.</description><issn>0039-6060</issn><issn>1532-7361</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9UctuFDEQtBCIbAI_wAH5yGUGv3YeiAuKgCAlIodwtjx2O3g1Yy_umUTLt-Rj8bABceJU3VJ1dXcVIa84qznjzdtdjUu-rQUTvOaiLvCEbPhWiqqVDX9KNozJvmpYw07IKeKOMdYr3j0nJ3LLm67jakMerpZxDggRU6Z7yH7BkCI1iIA4QZypTd9TninOizu8o9cZxjCFaPKBwl1wEC3QOd2b7KgpJBNdKcNPcP9qJE9DdMkeTAwR6G0GiNSPS8qA9rdEiGXRWHo7m5Guf0E-vCDPvBkRXj7iGfn26ePN-UV1-fXzl_MPl5VVjM1V2ykPw2DACFDMm643bWuZ2srBu84zJ12_NcOgRMvBSdVZ5007CG9E4wzr5Bl5c9Td5_RjAZz1FMpd42gipAW1aEQv216ptlDFkWpzQszg9T6HqbihOdNrKnqn1-v1mormQhcoQ68f9ZdhAvd35E8MhfD-SIDy5V2ArNGG1RcXVke0S-F_-r8A7qKlEw</recordid><startdate>20220701</startdate><enddate>20220701</enddate><creator>Soares, Antonio S.</creator><creator>Bano, Sophia</creator><creator>Clancy, Neil T.</creator><creator>Stoyanov, Danail</creator><creator>Lovat, Laurence B.</creator><creator>Chand, Manish</creator><general>Elsevier Inc</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-7773-2427</orcidid><orcidid>https://orcid.org/0000-0002-0980-3227</orcidid></search><sort><creationdate>20220701</creationdate><title>Multisensor perfusion assessment cohort study: Preliminary evidence toward a standardized assessment of indocyanine green fluorescence in colorectal surgery</title><author>Soares, Antonio S. ; Bano, Sophia ; Clancy, Neil T. ; Stoyanov, Danail ; Lovat, Laurence B. ; Chand, Manish</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c400t-784febbaea2e40fa89a77c0453bfd8f0d3d95abb4271ed348cdfa7b2fa26da083</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Soares, Antonio S.</creatorcontrib><creatorcontrib>Bano, Sophia</creatorcontrib><creatorcontrib>Clancy, Neil T.</creatorcontrib><creatorcontrib>Stoyanov, Danail</creatorcontrib><creatorcontrib>Lovat, Laurence B.</creatorcontrib><creatorcontrib>Chand, Manish</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Soares, Antonio S.</au><au>Bano, Sophia</au><au>Clancy, Neil T.</au><au>Stoyanov, Danail</au><au>Lovat, Laurence B.</au><au>Chand, Manish</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Multisensor perfusion assessment cohort study: Preliminary evidence toward a standardized assessment of indocyanine green fluorescence in colorectal surgery</atitle><jtitle>Surgery</jtitle><addtitle>Surgery</addtitle><date>2022-07-01</date><risdate>2022</risdate><volume>172</volume><issue>1</issue><spage>69</spage><epage>73</epage><pages>69-73</pages><issn>0039-6060</issn><eissn>1532-7361</eissn><abstract>Traditional methods of assessing colonic perfusion are based on the surgeon’s visual inspection of tissue. Fluorescence angiography provides qualitative information, but there remains disagreement on how the observed signal should be interpreted. It is unclear whether fluorescence correlates with physiological properties of the tissue, such as tissue oxygen saturation. The aim of this study was to correlate fluorescence intensity and colonic tissue oxygen saturation. Prospective cohort study performed in a single academic tertiary referral center. Patients undergoing colorectal surgery who required an anastomosis underwent dual-modality perfusion assessment of a segment of bowel before transection and creation of the anastomosis, using near-infrared and multispectral imaging. Perfusion was assessed using maximal fluorescence intensity measurement during fluorescence angiography, and its correlation with tissue oxygen saturation was calculated. In total, 18 patients were included. Maximal fluorescence intensity occurred at a mean of 101 seconds after indocyanine green injection. The correlation coefficient was 0.73 (95% confidence interval of 0.65–0.79) with P &lt; .0001, showing a statistically significant strong positive correlation between normalized fluorescence intensity and tissue oxygen saturation. The use of time averaging improved the correlation coefficient to 0.78. Fluorescence intensity is a potential surrogate for tissue oxygenation. This is expected to lead to improved decision making when transecting the bowel and, consequently, a reduction in anastomotic leak rates. A larger, phase II study is needed to confirm this result and form the basis of computational algorithms to infer biological or physiological information from the fluorescence imaging data.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>35168814</pmid><doi>10.1016/j.surg.2021.12.021</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0001-7773-2427</orcidid><orcidid>https://orcid.org/0000-0002-0980-3227</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0039-6060
ispartof Surgery, 2022-07, Vol.172 (1), p.69-73
issn 0039-6060
1532-7361
language eng
recordid cdi_proquest_miscellaneous_2629379447
source Access via ScienceDirect (Elsevier)
title Multisensor perfusion assessment cohort study: Preliminary evidence toward a standardized assessment of indocyanine green fluorescence in colorectal surgery
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T17%3A39%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Multisensor%20perfusion%20assessment%20cohort%20study:%20Preliminary%20evidence%20toward%20a%20standardized%20assessment%20of%20indocyanine%20green%20fluorescence%20in%20colorectal%20surgery&rft.jtitle=Surgery&rft.au=Soares,%20Antonio%20S.&rft.date=2022-07-01&rft.volume=172&rft.issue=1&rft.spage=69&rft.epage=73&rft.pages=69-73&rft.issn=0039-6060&rft.eissn=1532-7361&rft_id=info:doi/10.1016/j.surg.2021.12.021&rft_dat=%3Cproquest_cross%3E2629379447%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2629379447&rft_id=info:pmid/35168814&rft_els_id=S0039606021012447&rfr_iscdi=true