Early evaluation of a powered transfemoral prosthesis with force-modulated impedance control and energy regeneration

•Initial feasibility study for novel powered prosthetic knee.•Impedance controller and device both designed for energy regeneration.•Simplified control tuning (5 gains) relative to current literature (45 gains).•Controller demonstrates capacity for continuous speed adaptation.•Self-powered operation...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical engineering & physics 2022-02, Vol.100, p.103744-103744, Article 103744
Hauptverfasser: Warner, Holly, Khalaf, Poya, Richter, Hanz, Simon, Dan, Hardin, Elizabeth, van den Bogert, Antonie J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 103744
container_issue
container_start_page 103744
container_title Medical engineering & physics
container_volume 100
creator Warner, Holly
Khalaf, Poya
Richter, Hanz
Simon, Dan
Hardin, Elizabeth
van den Bogert, Antonie J.
description •Initial feasibility study for novel powered prosthetic knee.•Impedance controller and device both designed for energy regeneration.•Simplified control tuning (5 gains) relative to current literature (45 gains).•Controller demonstrates capacity for continuous speed adaptation.•Self-powered operation achieved under walking gait during pilot study. Individuals with an above-knee (AK) amputation typically use passive prostheses, whether reactive (microprocessor) or purely mechanical. Though sufficient for walking, these solutions lack the positive power generation observed in able-bodied individuals. Active (powered) prostheses can provide positive power but suffer complex control and limited energy storage capacities. These shortcomings motivate the development of an active prosthesis implementing a novel impedance controller design with energy regeneration. The controller requires only five tuning parameters that are intuitive to adjust in contrast to the current standard—finite state machine impedance scheduling of up to 45 gains. This simplification is uniquely achieved by modulating knee joint impedance by axial shank force. Furthermore, the proposed control approach introduces analytical guidance for impedance tuning to purposely integrate energy regeneration; specifically, a precise amount of negative damping is injected into the joint. A pilot study conducted with a volunteer with an AK amputation walking at three distinct speeds and at continually self-selected varying speeds demonstrated the adaptability of the controller to changes in speed. Self-powered operation was attained for all trials despite low mechanical component efficiencies. These early results suggest the efficacy of simplifying impedance control tuning and fusing control and energy regeneration in transfemoral prostheses.
doi_str_mv 10.1016/j.medengphy.2021.103744
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2628296446</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1350453321001442</els_id><sourcerecordid>2628296446</sourcerecordid><originalsourceid>FETCH-LOGICAL-c420t-f09eac245eb6cb1d010629adffc1ef122758c362a1bbbb444dea7c04e45f70b53</originalsourceid><addsrcrecordid>eNqFkE1PAyEQhonRWK3-BeXoZStfu9sejfErMfGiZ8LC0NLsLiuwmv57qa29yoUJeYZ35kHompIZJbS6Xc86MNAvh9Vmxgij-ZXXQhyhMzqveSEIJ8e55iUpRMn5BJ3HuCaECFHxUzThJRWi5vQMpQcV2g2GL9WOKjnfY2-xwoP_hgAGp6D6aKHzQbV4CD6mFUQX8bdLK2x90FB03oytShl23QBG9Rqw9n0KvsWqNxh6CMsNDrDcVr8ZF-jEqjbC5f6eoo_Hh_f75-L17enl_u610IKRVFiyAKWZKKGpdEMNoaRiC2Ws1RQsZawu55pXTNEmHyGEAVVrIkCUtiZNyafoZvdvnvxzhJhk56KGtlU9-DFKVrE5W1RbKVNU71Cdl4wBrByC61TYSErkVrlcy4NyuVUud8pz59U-ZGwycej7c5yBux0AedUvB0FG7SBrMi6ATtJ492_ID9M3mhI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2628296446</pqid></control><display><type>article</type><title>Early evaluation of a powered transfemoral prosthesis with force-modulated impedance control and energy regeneration</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Warner, Holly ; Khalaf, Poya ; Richter, Hanz ; Simon, Dan ; Hardin, Elizabeth ; van den Bogert, Antonie J.</creator><creatorcontrib>Warner, Holly ; Khalaf, Poya ; Richter, Hanz ; Simon, Dan ; Hardin, Elizabeth ; van den Bogert, Antonie J.</creatorcontrib><description>•Initial feasibility study for novel powered prosthetic knee.•Impedance controller and device both designed for energy regeneration.•Simplified control tuning (5 gains) relative to current literature (45 gains).•Controller demonstrates capacity for continuous speed adaptation.•Self-powered operation achieved under walking gait during pilot study. Individuals with an above-knee (AK) amputation typically use passive prostheses, whether reactive (microprocessor) or purely mechanical. Though sufficient for walking, these solutions lack the positive power generation observed in able-bodied individuals. Active (powered) prostheses can provide positive power but suffer complex control and limited energy storage capacities. These shortcomings motivate the development of an active prosthesis implementing a novel impedance controller design with energy regeneration. The controller requires only five tuning parameters that are intuitive to adjust in contrast to the current standard—finite state machine impedance scheduling of up to 45 gains. This simplification is uniquely achieved by modulating knee joint impedance by axial shank force. Furthermore, the proposed control approach introduces analytical guidance for impedance tuning to purposely integrate energy regeneration; specifically, a precise amount of negative damping is injected into the joint. A pilot study conducted with a volunteer with an AK amputation walking at three distinct speeds and at continually self-selected varying speeds demonstrated the adaptability of the controller to changes in speed. Self-powered operation was attained for all trials despite low mechanical component efficiencies. These early results suggest the efficacy of simplifying impedance control tuning and fusing control and energy regeneration in transfemoral prostheses.</description><identifier>ISSN: 1350-4533</identifier><identifier>EISSN: 1873-4030</identifier><identifier>DOI: 10.1016/j.medengphy.2021.103744</identifier><identifier>PMID: 35144731</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Amputees ; Artificial Limbs ; Biomechanical Phenomena ; Electric Impedance ; Energy regeneration ; Gait ; Humans ; Impedance control ; Knee Prosthesis ; Lower-limb prosthesis ; Pilot Projects ; Powered prosthesis ; Prosthesis Design ; Transfemoral prosthesis ; Walking</subject><ispartof>Medical engineering &amp; physics, 2022-02, Vol.100, p.103744-103744, Article 103744</ispartof><rights>2021 IPEM</rights><rights>Copyright © 2021 IPEM. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c420t-f09eac245eb6cb1d010629adffc1ef122758c362a1bbbb444dea7c04e45f70b53</citedby><cites>FETCH-LOGICAL-c420t-f09eac245eb6cb1d010629adffc1ef122758c362a1bbbb444dea7c04e45f70b53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.medengphy.2021.103744$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35144731$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Warner, Holly</creatorcontrib><creatorcontrib>Khalaf, Poya</creatorcontrib><creatorcontrib>Richter, Hanz</creatorcontrib><creatorcontrib>Simon, Dan</creatorcontrib><creatorcontrib>Hardin, Elizabeth</creatorcontrib><creatorcontrib>van den Bogert, Antonie J.</creatorcontrib><title>Early evaluation of a powered transfemoral prosthesis with force-modulated impedance control and energy regeneration</title><title>Medical engineering &amp; physics</title><addtitle>Med Eng Phys</addtitle><description>•Initial feasibility study for novel powered prosthetic knee.•Impedance controller and device both designed for energy regeneration.•Simplified control tuning (5 gains) relative to current literature (45 gains).•Controller demonstrates capacity for continuous speed adaptation.•Self-powered operation achieved under walking gait during pilot study. Individuals with an above-knee (AK) amputation typically use passive prostheses, whether reactive (microprocessor) or purely mechanical. Though sufficient for walking, these solutions lack the positive power generation observed in able-bodied individuals. Active (powered) prostheses can provide positive power but suffer complex control and limited energy storage capacities. These shortcomings motivate the development of an active prosthesis implementing a novel impedance controller design with energy regeneration. The controller requires only five tuning parameters that are intuitive to adjust in contrast to the current standard—finite state machine impedance scheduling of up to 45 gains. This simplification is uniquely achieved by modulating knee joint impedance by axial shank force. Furthermore, the proposed control approach introduces analytical guidance for impedance tuning to purposely integrate energy regeneration; specifically, a precise amount of negative damping is injected into the joint. A pilot study conducted with a volunteer with an AK amputation walking at three distinct speeds and at continually self-selected varying speeds demonstrated the adaptability of the controller to changes in speed. Self-powered operation was attained for all trials despite low mechanical component efficiencies. These early results suggest the efficacy of simplifying impedance control tuning and fusing control and energy regeneration in transfemoral prostheses.</description><subject>Amputees</subject><subject>Artificial Limbs</subject><subject>Biomechanical Phenomena</subject><subject>Electric Impedance</subject><subject>Energy regeneration</subject><subject>Gait</subject><subject>Humans</subject><subject>Impedance control</subject><subject>Knee Prosthesis</subject><subject>Lower-limb prosthesis</subject><subject>Pilot Projects</subject><subject>Powered prosthesis</subject><subject>Prosthesis Design</subject><subject>Transfemoral prosthesis</subject><subject>Walking</subject><issn>1350-4533</issn><issn>1873-4030</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE1PAyEQhonRWK3-BeXoZStfu9sejfErMfGiZ8LC0NLsLiuwmv57qa29yoUJeYZ35kHompIZJbS6Xc86MNAvh9Vmxgij-ZXXQhyhMzqveSEIJ8e55iUpRMn5BJ3HuCaECFHxUzThJRWi5vQMpQcV2g2GL9WOKjnfY2-xwoP_hgAGp6D6aKHzQbV4CD6mFUQX8bdLK2x90FB03oytShl23QBG9Rqw9n0KvsWqNxh6CMsNDrDcVr8ZF-jEqjbC5f6eoo_Hh_f75-L17enl_u610IKRVFiyAKWZKKGpdEMNoaRiC2Ws1RQsZawu55pXTNEmHyGEAVVrIkCUtiZNyafoZvdvnvxzhJhk56KGtlU9-DFKVrE5W1RbKVNU71Cdl4wBrByC61TYSErkVrlcy4NyuVUud8pz59U-ZGwycej7c5yBux0AedUvB0FG7SBrMi6ATtJ492_ID9M3mhI</recordid><startdate>202202</startdate><enddate>202202</enddate><creator>Warner, Holly</creator><creator>Khalaf, Poya</creator><creator>Richter, Hanz</creator><creator>Simon, Dan</creator><creator>Hardin, Elizabeth</creator><creator>van den Bogert, Antonie J.</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202202</creationdate><title>Early evaluation of a powered transfemoral prosthesis with force-modulated impedance control and energy regeneration</title><author>Warner, Holly ; Khalaf, Poya ; Richter, Hanz ; Simon, Dan ; Hardin, Elizabeth ; van den Bogert, Antonie J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c420t-f09eac245eb6cb1d010629adffc1ef122758c362a1bbbb444dea7c04e45f70b53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Amputees</topic><topic>Artificial Limbs</topic><topic>Biomechanical Phenomena</topic><topic>Electric Impedance</topic><topic>Energy regeneration</topic><topic>Gait</topic><topic>Humans</topic><topic>Impedance control</topic><topic>Knee Prosthesis</topic><topic>Lower-limb prosthesis</topic><topic>Pilot Projects</topic><topic>Powered prosthesis</topic><topic>Prosthesis Design</topic><topic>Transfemoral prosthesis</topic><topic>Walking</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Warner, Holly</creatorcontrib><creatorcontrib>Khalaf, Poya</creatorcontrib><creatorcontrib>Richter, Hanz</creatorcontrib><creatorcontrib>Simon, Dan</creatorcontrib><creatorcontrib>Hardin, Elizabeth</creatorcontrib><creatorcontrib>van den Bogert, Antonie J.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical engineering &amp; physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Warner, Holly</au><au>Khalaf, Poya</au><au>Richter, Hanz</au><au>Simon, Dan</au><au>Hardin, Elizabeth</au><au>van den Bogert, Antonie J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Early evaluation of a powered transfemoral prosthesis with force-modulated impedance control and energy regeneration</atitle><jtitle>Medical engineering &amp; physics</jtitle><addtitle>Med Eng Phys</addtitle><date>2022-02</date><risdate>2022</risdate><volume>100</volume><spage>103744</spage><epage>103744</epage><pages>103744-103744</pages><artnum>103744</artnum><issn>1350-4533</issn><eissn>1873-4030</eissn><abstract>•Initial feasibility study for novel powered prosthetic knee.•Impedance controller and device both designed for energy regeneration.•Simplified control tuning (5 gains) relative to current literature (45 gains).•Controller demonstrates capacity for continuous speed adaptation.•Self-powered operation achieved under walking gait during pilot study. Individuals with an above-knee (AK) amputation typically use passive prostheses, whether reactive (microprocessor) or purely mechanical. Though sufficient for walking, these solutions lack the positive power generation observed in able-bodied individuals. Active (powered) prostheses can provide positive power but suffer complex control and limited energy storage capacities. These shortcomings motivate the development of an active prosthesis implementing a novel impedance controller design with energy regeneration. The controller requires only five tuning parameters that are intuitive to adjust in contrast to the current standard—finite state machine impedance scheduling of up to 45 gains. This simplification is uniquely achieved by modulating knee joint impedance by axial shank force. Furthermore, the proposed control approach introduces analytical guidance for impedance tuning to purposely integrate energy regeneration; specifically, a precise amount of negative damping is injected into the joint. A pilot study conducted with a volunteer with an AK amputation walking at three distinct speeds and at continually self-selected varying speeds demonstrated the adaptability of the controller to changes in speed. Self-powered operation was attained for all trials despite low mechanical component efficiencies. These early results suggest the efficacy of simplifying impedance control tuning and fusing control and energy regeneration in transfemoral prostheses.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>35144731</pmid><doi>10.1016/j.medengphy.2021.103744</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1350-4533
ispartof Medical engineering & physics, 2022-02, Vol.100, p.103744-103744, Article 103744
issn 1350-4533
1873-4030
language eng
recordid cdi_proquest_miscellaneous_2628296446
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects Amputees
Artificial Limbs
Biomechanical Phenomena
Electric Impedance
Energy regeneration
Gait
Humans
Impedance control
Knee Prosthesis
Lower-limb prosthesis
Pilot Projects
Powered prosthesis
Prosthesis Design
Transfemoral prosthesis
Walking
title Early evaluation of a powered transfemoral prosthesis with force-modulated impedance control and energy regeneration
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T11%3A23%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Early%20evaluation%20of%20a%20powered%20transfemoral%20prosthesis%20with%20force-modulated%20impedance%20control%20and%20energy%20regeneration&rft.jtitle=Medical%20engineering%20&%20physics&rft.au=Warner,%20Holly&rft.date=2022-02&rft.volume=100&rft.spage=103744&rft.epage=103744&rft.pages=103744-103744&rft.artnum=103744&rft.issn=1350-4533&rft.eissn=1873-4030&rft_id=info:doi/10.1016/j.medengphy.2021.103744&rft_dat=%3Cproquest_cross%3E2628296446%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2628296446&rft_id=info:pmid/35144731&rft_els_id=S1350453321001442&rfr_iscdi=true