Treatment of Resistant Hypertension With Endovascular Baroreflex Amplification: 3-Year Results From the CALM-FIM Study
The aim of this study was to evaluate the long-term (3-year) safety and effectiveness of endovascular baroreflex amplification (EVBA) from both the European and American CALM-FIM cohorts. The CALM-FIM study demonstrated that EVBA in patients with resistant hypertension significantly lowered blood pr...
Gespeichert in:
Veröffentlicht in: | JACC. Cardiovascular interventions 2022-02, Vol.15 (3), p.321-332 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this study was to evaluate the long-term (3-year) safety and effectiveness of endovascular baroreflex amplification (EVBA) from both the European and American CALM-FIM cohorts.
The CALM-FIM study demonstrated that EVBA in patients with resistant hypertension significantly lowered blood pressure (BP) with an acceptable safety profile during 6-month follow-up.
The CALM-FIM studies were prospective, nonrandomized, first-in-human studies that enrolled patients with resistant hypertension (office systolic BP ≥160 mm Hg and mean 24-hour ambulatory BP ≥130/80 mm Hg despite a stable regimen of ≥3 antihypertensive medications, including a diuretic agent). The incidence of (serious) adverse events and changes in BP, heart rate, and prescribed antihypertensive medication up to 3 years after implantation were determined.
The Mobius device was implanted in 47 patients (30 in Europe, 17 in the United States; mean age 54 years, 23 women). Five serious adverse events (hypotension, n = 2; hypertension, n = 1; vascular access complications, n = 2) and 2 transient ischemic attacks occurred within 30 days postprocedure. Two strokes and 1 transient ischemic attack occurred more than 2 years postimplantation. Mean office BP at baseline was 181 ± 17/107 ± 16 mm Hg and decreased by 25/12 mm Hg (95% CI: 17-33/8-17 mm Hg) at 6 months and 30/12 mm Hg (95% CI: 21-38/8-17 mm Hg) at 3 years. Mean 24-hour ambulatory BP at baseline was 166 ± 16/98 ± 15 mm Hg and decreased by 20/11 mm Hg (95% CI: 14-25/8-15 mm Hg) at 6 months.
EVBA with the MobiusHD was effective in reducing BP at 3-year follow-up and appears to have an acceptable safety profile in patients with uncomplicated implantation, although data from randomized sham-controlled trials are needed to further evaluate the risk-benefit profile. (Controlling and Lowering Blood Pressure With the MobiusHD™ [CALM-FIM_EUR], NCT01911897; Controlling and Lowering Blood Pressure With the MobiusHD™ [CALM-FIM_US], NCT01831895). |
---|---|
ISSN: | 1876-7605 |
DOI: | 10.1016/j.jcin.2021.12.015 |