Argyrophilic nucleolar organizer regions as a promising biomarker for the detection of brain hypoxia levels caused by different doses of carbon monoxide poisoning

The purpose of the study is to investigate whether there is any relationship between mean argyrophilic nucleolar organizing regions (AgNOR) number and total AgNOR area/total nuclear area (TAA/TNA) ratio and the levels of brain hypoxia after exposure to different acute doses of carbon monoxide (CO) g...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gaceta médica de México 2021, Vol.157 (6), p.610-617
Hauptverfasser: Yesildag, Kerim, Kokulu, Kamil, Mutlu, Huseyin, Eroz, Recep, Taha-Sert, Ekrem, Saritas, Ayhan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 617
container_issue 6
container_start_page 610
container_title Gaceta médica de México
container_volume 157
creator Yesildag, Kerim
Kokulu, Kamil
Mutlu, Huseyin
Eroz, Recep
Taha-Sert, Ekrem
Saritas, Ayhan
description The purpose of the study is to investigate whether there is any relationship between mean argyrophilic nucleolar organizing regions (AgNOR) number and total AgNOR area/total nuclear area (TAA/TNA) ratio and the levels of brain hypoxia after exposure to different acute doses of carbon monoxide (CO) gas. Each experimental group was exposed to CO gas (concentrations of 1,000, 3,000 and 5,000 ppm). Then, the rats were anesthetized, and blood samples were taken from the right jugular vein for carboxyhemoglobin levels detection. The rats were sacrificed on seventh day. AgNOR staining was applied to brain tissues. TAA/TNA and mean AgNOR number were detected for each nucleus. Significant differences were detected among all groups for TAA/TNA ratio, mean AgNOR number and carboxyhemoglobin level. According to a double comparison of groups, the differences between control and 1,000 ppm, control and 3,000 ppm, control and 5,000 ppm, and between 1,000 and 5,000 ppm were significant for TAA/TNA ratio. When mean AgNOR number was considered, significant differences were detected between control and 1,000 ppm, control and 3,000 ppm, control and 5,000 ppm, and between 1,000 and 3,000 ppm. AgNOR proteins may be used for early detection of the duration, intensity, and damage of brain injury caused by CO poisoning. Thus, effective treatment strategies can be developed for the prevention of hypoxic conditions.
doi_str_mv 10.24875/GMM.M21000625
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2625265037</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2625265037</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1805-d98da389808d8bdd441a6fb1bf96c7a8af672ef758267191f95e899ba7942ee33</originalsourceid><addsrcrecordid>eNo9kU9PGzEQxX2gIhS4ckRz7CWp7Y137SNCNCAR9dKeV_4zTlw29tbeRU0_Dp-0bqFII83l995o3iPkitEVX8tOfN5st6stZ5TSlosTckYpa5eNZM2CfCzlB6VctFSdkkUjGJVcsDPycpN3x5zGfRiChTjbAdOgM6S80zH8xgwZdyHFAroOjDkdQglxByakg85PFfApw7RHcDihnSoLyYPJOkTYH8f0K2gY8BmHAlbPBR2YI7jgPWaME7hUsPxVWJ1N1R5SrBKHMKZQUqynLsgHr4eCl2_7nHz_cvft9n75-HXzcHvzuLRMUrF0SjrdSCWpdNI4t14z3XrDjFet7bTUvu04-k5I3nZMMa8ESqWM7tSaIzbNOfn06luf_Dljmfr6qsVh0BHTXHpeQ-WtoE1X0dUranMqJaPvxxxqHMee0f5fF33ton_vogqu37xnc0D3jv8vovkDgfuKsw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2625265037</pqid></control><display><type>article</type><title>Argyrophilic nucleolar organizer regions as a promising biomarker for the detection of brain hypoxia levels caused by different doses of carbon monoxide poisoning</title><source>MEDLINE</source><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Yesildag, Kerim ; Kokulu, Kamil ; Mutlu, Huseyin ; Eroz, Recep ; Taha-Sert, Ekrem ; Saritas, Ayhan</creator><creatorcontrib>Yesildag, Kerim ; Kokulu, Kamil ; Mutlu, Huseyin ; Eroz, Recep ; Taha-Sert, Ekrem ; Saritas, Ayhan</creatorcontrib><description>The purpose of the study is to investigate whether there is any relationship between mean argyrophilic nucleolar organizing regions (AgNOR) number and total AgNOR area/total nuclear area (TAA/TNA) ratio and the levels of brain hypoxia after exposure to different acute doses of carbon monoxide (CO) gas. Each experimental group was exposed to CO gas (concentrations of 1,000, 3,000 and 5,000 ppm). Then, the rats were anesthetized, and blood samples were taken from the right jugular vein for carboxyhemoglobin levels detection. The rats were sacrificed on seventh day. AgNOR staining was applied to brain tissues. TAA/TNA and mean AgNOR number were detected for each nucleus. Significant differences were detected among all groups for TAA/TNA ratio, mean AgNOR number and carboxyhemoglobin level. According to a double comparison of groups, the differences between control and 1,000 ppm, control and 3,000 ppm, control and 5,000 ppm, and between 1,000 and 5,000 ppm were significant for TAA/TNA ratio. When mean AgNOR number was considered, significant differences were detected between control and 1,000 ppm, control and 3,000 ppm, control and 5,000 ppm, and between 1,000 and 3,000 ppm. AgNOR proteins may be used for early detection of the duration, intensity, and damage of brain injury caused by CO poisoning. Thus, effective treatment strategies can be developed for the prevention of hypoxic conditions.</description><identifier>ISSN: 0016-3813</identifier><identifier>DOI: 10.24875/GMM.M21000625</identifier><identifier>PMID: 35108251</identifier><language>eng</language><publisher>Mexico</publisher><subject>Animals ; Antigens, Nuclear ; Biomarkers ; Carbon Monoxide Poisoning - diagnosis ; Hypoxia, Brain - diagnosis ; Nucleolus Organizer Region ; Rats</subject><ispartof>Gaceta médica de México, 2021, Vol.157 (6), p.610-617</ispartof><rights>Copyright: © 2021 Permanyer.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1805-d98da389808d8bdd441a6fb1bf96c7a8af672ef758267191f95e899ba7942ee33</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35108251$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yesildag, Kerim</creatorcontrib><creatorcontrib>Kokulu, Kamil</creatorcontrib><creatorcontrib>Mutlu, Huseyin</creatorcontrib><creatorcontrib>Eroz, Recep</creatorcontrib><creatorcontrib>Taha-Sert, Ekrem</creatorcontrib><creatorcontrib>Saritas, Ayhan</creatorcontrib><title>Argyrophilic nucleolar organizer regions as a promising biomarker for the detection of brain hypoxia levels caused by different doses of carbon monoxide poisoning</title><title>Gaceta médica de México</title><addtitle>Gac Med Mex</addtitle><description>The purpose of the study is to investigate whether there is any relationship between mean argyrophilic nucleolar organizing regions (AgNOR) number and total AgNOR area/total nuclear area (TAA/TNA) ratio and the levels of brain hypoxia after exposure to different acute doses of carbon monoxide (CO) gas. Each experimental group was exposed to CO gas (concentrations of 1,000, 3,000 and 5,000 ppm). Then, the rats were anesthetized, and blood samples were taken from the right jugular vein for carboxyhemoglobin levels detection. The rats were sacrificed on seventh day. AgNOR staining was applied to brain tissues. TAA/TNA and mean AgNOR number were detected for each nucleus. Significant differences were detected among all groups for TAA/TNA ratio, mean AgNOR number and carboxyhemoglobin level. According to a double comparison of groups, the differences between control and 1,000 ppm, control and 3,000 ppm, control and 5,000 ppm, and between 1,000 and 5,000 ppm were significant for TAA/TNA ratio. When mean AgNOR number was considered, significant differences were detected between control and 1,000 ppm, control and 3,000 ppm, control and 5,000 ppm, and between 1,000 and 3,000 ppm. AgNOR proteins may be used for early detection of the duration, intensity, and damage of brain injury caused by CO poisoning. Thus, effective treatment strategies can be developed for the prevention of hypoxic conditions.</description><subject>Animals</subject><subject>Antigens, Nuclear</subject><subject>Biomarkers</subject><subject>Carbon Monoxide Poisoning - diagnosis</subject><subject>Hypoxia, Brain - diagnosis</subject><subject>Nucleolus Organizer Region</subject><subject>Rats</subject><issn>0016-3813</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kU9PGzEQxX2gIhS4ckRz7CWp7Y137SNCNCAR9dKeV_4zTlw29tbeRU0_Dp-0bqFII83l995o3iPkitEVX8tOfN5st6stZ5TSlosTckYpa5eNZM2CfCzlB6VctFSdkkUjGJVcsDPycpN3x5zGfRiChTjbAdOgM6S80zH8xgwZdyHFAroOjDkdQglxByakg85PFfApw7RHcDihnSoLyYPJOkTYH8f0K2gY8BmHAlbPBR2YI7jgPWaME7hUsPxVWJ1N1R5SrBKHMKZQUqynLsgHr4eCl2_7nHz_cvft9n75-HXzcHvzuLRMUrF0SjrdSCWpdNI4t14z3XrDjFet7bTUvu04-k5I3nZMMa8ESqWM7tSaIzbNOfn06luf_Dljmfr6qsVh0BHTXHpeQ-WtoE1X0dUranMqJaPvxxxqHMee0f5fF33ton_vogqu37xnc0D3jv8vovkDgfuKsw</recordid><startdate>2021</startdate><enddate>2021</enddate><creator>Yesildag, Kerim</creator><creator>Kokulu, Kamil</creator><creator>Mutlu, Huseyin</creator><creator>Eroz, Recep</creator><creator>Taha-Sert, Ekrem</creator><creator>Saritas, Ayhan</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>2021</creationdate><title>Argyrophilic nucleolar organizer regions as a promising biomarker for the detection of brain hypoxia levels caused by different doses of carbon monoxide poisoning</title><author>Yesildag, Kerim ; Kokulu, Kamil ; Mutlu, Huseyin ; Eroz, Recep ; Taha-Sert, Ekrem ; Saritas, Ayhan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1805-d98da389808d8bdd441a6fb1bf96c7a8af672ef758267191f95e899ba7942ee33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Animals</topic><topic>Antigens, Nuclear</topic><topic>Biomarkers</topic><topic>Carbon Monoxide Poisoning - diagnosis</topic><topic>Hypoxia, Brain - diagnosis</topic><topic>Nucleolus Organizer Region</topic><topic>Rats</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yesildag, Kerim</creatorcontrib><creatorcontrib>Kokulu, Kamil</creatorcontrib><creatorcontrib>Mutlu, Huseyin</creatorcontrib><creatorcontrib>Eroz, Recep</creatorcontrib><creatorcontrib>Taha-Sert, Ekrem</creatorcontrib><creatorcontrib>Saritas, Ayhan</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Gaceta médica de México</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yesildag, Kerim</au><au>Kokulu, Kamil</au><au>Mutlu, Huseyin</au><au>Eroz, Recep</au><au>Taha-Sert, Ekrem</au><au>Saritas, Ayhan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Argyrophilic nucleolar organizer regions as a promising biomarker for the detection of brain hypoxia levels caused by different doses of carbon monoxide poisoning</atitle><jtitle>Gaceta médica de México</jtitle><addtitle>Gac Med Mex</addtitle><date>2021</date><risdate>2021</risdate><volume>157</volume><issue>6</issue><spage>610</spage><epage>617</epage><pages>610-617</pages><issn>0016-3813</issn><abstract>The purpose of the study is to investigate whether there is any relationship between mean argyrophilic nucleolar organizing regions (AgNOR) number and total AgNOR area/total nuclear area (TAA/TNA) ratio and the levels of brain hypoxia after exposure to different acute doses of carbon monoxide (CO) gas. Each experimental group was exposed to CO gas (concentrations of 1,000, 3,000 and 5,000 ppm). Then, the rats were anesthetized, and blood samples were taken from the right jugular vein for carboxyhemoglobin levels detection. The rats were sacrificed on seventh day. AgNOR staining was applied to brain tissues. TAA/TNA and mean AgNOR number were detected for each nucleus. Significant differences were detected among all groups for TAA/TNA ratio, mean AgNOR number and carboxyhemoglobin level. According to a double comparison of groups, the differences between control and 1,000 ppm, control and 3,000 ppm, control and 5,000 ppm, and between 1,000 and 5,000 ppm were significant for TAA/TNA ratio. When mean AgNOR number was considered, significant differences were detected between control and 1,000 ppm, control and 3,000 ppm, control and 5,000 ppm, and between 1,000 and 3,000 ppm. AgNOR proteins may be used for early detection of the duration, intensity, and damage of brain injury caused by CO poisoning. Thus, effective treatment strategies can be developed for the prevention of hypoxic conditions.</abstract><cop>Mexico</cop><pmid>35108251</pmid><doi>10.24875/GMM.M21000625</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0016-3813
ispartof Gaceta médica de México, 2021, Vol.157 (6), p.610-617
issn 0016-3813
language eng
recordid cdi_proquest_miscellaneous_2625265037
source MEDLINE; DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals
subjects Animals
Antigens, Nuclear
Biomarkers
Carbon Monoxide Poisoning - diagnosis
Hypoxia, Brain - diagnosis
Nucleolus Organizer Region
Rats
title Argyrophilic nucleolar organizer regions as a promising biomarker for the detection of brain hypoxia levels caused by different doses of carbon monoxide poisoning
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T02%3A48%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Argyrophilic%20nucleolar%20organizer%20regions%20as%20a%20promising%20biomarker%20for%20the%20detection%20of%20brain%20hypoxia%20levels%20caused%20by%20different%20doses%20of%20carbon%20monoxide%20poisoning&rft.jtitle=Gaceta%20m%C3%A9dica%20de%20M%C3%A9xico&rft.au=Yesildag,%20Kerim&rft.date=2021&rft.volume=157&rft.issue=6&rft.spage=610&rft.epage=617&rft.pages=610-617&rft.issn=0016-3813&rft_id=info:doi/10.24875/GMM.M21000625&rft_dat=%3Cproquest_cross%3E2625265037%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2625265037&rft_id=info:pmid/35108251&rfr_iscdi=true